        2024.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Due to seismically deficient details, existing reinforced concrete structures have low lateral resistance capacities. Since these building structures suffer an increase in axial loads to the main structural element due to the green retrofit (e.g., energy equipment/device, roof garden) for CO2 reduction and vertical extension, building capacities are reduced. This paper proposes a machine-learning-based methodology for allowable ranges of axial loading ratio to reinforced concrete columns using simple structural details. The methodology consists of a two-step procedure: (1) a machine-learning-based failure detection model and (2) column damage limits proposed by previous researchers. To demonstrate this proposed method, the existing building structure built in the 1990s was selected, and the allowable range for the target structure was computed for exterior and interior columns.
        4,000원
        3.
        2014.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, shaking table test was carried out to evaluate the seismic behavior and performance of low-rise reinforced concrete (RC) piloti structures with and without retrofit. The specimens were designed considering the characteristics of existing building with pilotis such as natural period, distribution factor of strength and stiffness between columns and core wall on the first soft story. The test for the non-retrofit specimen showed that damage was concentrated on the stiffer member on the same floor as the core wall failed by shear fracture whereas columns experienced slight flexural cracks. Considering the failure mode of the non-retrofit specimen, the retrofit method using steel rod damper was presented for improving the seismic performance of piloti structures. The results of the test for retrofit specimen revealed that the retrofit method was effective for controlling the damage as the main RC structural members were not destroyed and most of input energy was dissipated by hysteretic behavior of the damper.
        4,200원
        4.
        2009.09 구독 인증기관 무료, 개인회원 유료
        For new construction, recently, it has expended from physical performance standard to completed apartment' blemish warranty and countermeasure strategy contents. And considering element technology is increasing remodeling’ easiness for deciding operation right or wrong the aged apartment’ re-construction or remodeling. In addition, international standardization of building performance makes rapid progress the point of ISO. In Japan, study of housing commission will be done on a national level for the long commission metropolitan gathering house construction and reproduction technical development, and, already, involving study of approval system of building element made progress. It set the goal performance log index of remodeling’ easiness, it set up component element between a part and public standard type in remodeling. In plan and design phase, it is a precondition that make the performance on the basis of user demand in the whole of Use, maintenance, repair, waste and reuse. Therefore, in the building technology case that development of element technology and practical use are fast in progress, a user is required to evaluate/choice according to performance. And a developer is required to the technical development that aim performance is cleared. The study selected a detailed item about performance item of re-modeling element technique through the requirement which the nations (such as America, England, Japan, etc) and the agencies of foreign countries present and item selection standard, from the point of view where the interest not only the individual but also govemmental politic viewpoint is coming to be higher re-modelling than new construction.
        4,000원
        5.
        2000.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        중약진 지역으로 분류되고 있는 대만에서 1999년에 발생된 예상치 못한 막대한 경제적 피해와 사상자를 기록하였다. 대만과 마찬가가지로 중약진지역으로 분류되는 우리나라에서도 지진발생시 많은 문제발생이 예상됨에 따라 기존건물의 내진성능평가의 필요성의 인식하게 되었다. 본 연구에서는 미국과 일본에서 이미 적용되고 있는 기존 건축물의 내진성능 평가 기법을 분석하고 이를 3층 규모의 모멘트 골조 건물에 적용하여 평가해 보았다. 평가는 일본건축방재협회에는 철근콘크리트 구조물의 내진성능평가 규준을 적용하였다.
        4,000원
        6.
        2019.04 서비스 종료(열람 제한)
        This research presents effectiveness of fiber-reinforced polymer column jacketing system for a non-ductile reinforced concrete building frame constructed before the 1970s. To investigate the retrofit effects, a series of full-scale dynamic tests for the retrofitted test frame was conducted, and the dynamic responses were compared to those of the non-retrofitted test frame. The effectiveness of the retrofit system was investigated in terms of response reductions, damage mechanisms and drift concentration factors.
        8.
        2013.10 서비스 종료(열람 제한)
        This study is about earthquake-proof reinforcement through structural function evaluation of an existing structure. The purpose of this study is to comparatively analyze structure reinforcement measures in consideration of safety and usability through structural function evaluation of existing structures, to offer rational measures for earthquake-proof function and to provide help in maintaining safe structures against earthquake. For this purpose, was selected for this study as an existing school building, earthquake-proof function evaluation was conducted, and measures to reinforce earthquake-proof function was offered. As for the research method, the first and the second earthquake-proof function evaluations were conducted which is an existing reinforced concrete school building. Through the abovementioned methods, earthquake-proof function evaluations were conducted, the results were analyzed and the measure to reinforce earthquake-proof function were offered(reinforcement brace, RC shear wall reinforcement). The offered measure to reinforce earthquake-proof function was applied to the subject structure, and comprehensive results were derived from earthquake-proof function evaluation regarding before and after earthquake-proof function reinforcement.
        9.
        2012.11 서비스 종료(열람 제한)
        The aim of this study is to evaluate performance of snow-resistant for the existing building. For this purpose, it was to propose a way to evaluate whether facilities reach goal performance as performance level separated by immediate occupancy level and collapse prevention level. Preliminary evaluation was developed to conduct by using assessment index of five items of vulnerability and two items of impact for selecting the reinforcement priority of target facilities.
        10.
        2012.02 서비스 종료(열람 제한)
        재해나 재난으로 인하여 건축물에 발생하는 경제적인 피해규모는 건축물에 내재된 현존가치의 손실분과 재사용이 가능할 만큼의 성능회복을 위한 복구비를 포함하는 것이 일반적이다. 건축물의 현존가치는 경과연수와 성능의 관계로부터 정의될 수 있다. 그런데 만일 지진피해를 입은 상태에서 건축물의 성능상태는 현지조사를 통해 쉽게 파악되겠지만, 지진으로 인하여 건축성능이 얼마큼 손상되었는지를 명확히 파악하는 것은 건축물의 성능상태를 사전에 알고 있지 않고서는 현실적으로 쉽지 않은 일이다. 그런데 통계에 따르면, 국내 건축물 동수 현황은 718만여 동이고, 이 중에서 각종의 법 규정에 따라 건축물의 상태나 안전성에 대하여 관리되는 건축물은 145천여 동으로 전체의 약 2%에 불과하고, 나머지 약 98%에 달하는 건축물에 대한 성능상태는 전혀 알 수 없다. 그래서 지진으로 인한 건축물의 경제적 피해를 정상적으로 예측하는 데는 한계가 있다. 이번 연구에서는 대다수의 건축물에 대해서는 현행법 규정에 따라 시행되는 “시설물 안전점검 및 정밀안전진단 지침과 같은 세부지침”에서 정한 정성적인 평가방법인 안전등급 판정을 준용해 성능을 정량적으로 평가하고, 모든 건축물에 대해 현장조사를 통하여 성능을 평가할 수 없음으로 경과연수에 따라 그 성능이 자연적인 감소되는 경향에 대하여 건축물의 성능곡선 모델을 통해 일반화하여 이들의 결과로부터 건축물의 현존가치 곡선 모델을 도출하고자 한다. 따라서 이번 연구에서는 경과연수에 따른 건축물의 성능지표와 현존가치 곡선 모델을 제안함으로써 ‘지진으로 인한 건축물의 피해예측 모델 개발’에 기여하는데 그 목적이 있다.
        11.
        2011.02 서비스 종료(열람 제한)
        최근 세계 곳곳에서 대규모 지진이 발생하여 건축물 붕괴에 따른 피해가 속출함에 따라 지진에 대비하기 위해 기존 건축물의 내진 성능을 보강방안에 대한 관심이 높아지고 있다. 그러나 현재 우리나라의 경우, 교육생활의 터전임과 동시에 가구 재난 발생 시 지역주민들의 응급피난장소인 학교 건축물조차 내진설계가 제대로 이루어져 있지 않고 있어, 지진 발생 시 막대한 피해가 예상된다. 현 상황을 극복하기 위해 기존 노후화 학교 건축물의 내진성능을 향상시키기 위한 적절한 보강방안이 제시되어야한다. 본 논문에서는 범용해석프로그램을 통해 기존 노후화 학교 건축물에 대한 비선형정적해석에 결과에 따른 내진보강 후 비선형 시간이력해석을 실시하여 지진하중에 의한 구조물의 비선형 거동을 규명하고 내진 보강 효과를 검증하고자 한다.
        12.
        2009.11 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 국내에서 수행되었던 조적조의 재료특성과 부재특성에 대한 실험연구 결과를 이용하여 유한요소 해석을 수행하여 본 연구에서 이용한 유한요소 해석 방법에 대한 신뢰성을 확보한 다음, Prototype 조적조 건축물에 적용하여 얻은 내진성능을 분석하여 국내 비보강 조적조 건축물의 지진에 대한 안전성을 평가하고자 하였으며, Prototype 건축물의 해석결과, 수평전단력과 평균 전단응력은 기존의 실험연구와 비슷한 값을 나타냈다.