검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 26

        1.
        2023.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a smart bench was developed and researched smart benches that can contribute to user convenience and satisfaction by installing them in parks, bus stops, and tourist attractions in line with the rapidly changing construction of smart cities. The smart bench is automatically operated by the control system according to the external temperature and provides additional functions such as charging, lighting, and advertising to improve general bench functions as well as heating in winter and cooling in summer, making it suitable for smart urbanization. The developed smart bench is designed to be strong enough to withstand loads of about 2,500 N. It minimizes the visible parts such as assembled bolts and 220V power supply wires, It can also give aesthetic effects. The development was carried out with the aim of waterproofing and dustproofing of IP44 grade in accordance with the climate of Republic of Korea, which has four seasons, and it is advantageous for long-term use because the paint was selected for the weather ability (discoloration) grade 3 or higher. If smart bench is commercialized, it is believed that various options can be provided to the smart bench market, where buyers had few product options, as the parts were developed in an assembled type so that all functions can be responded in an optional form according to the installation environment and the buyer's budget.
        4,000원
        3.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        모바일 기반 온실에너지 계산프로그램을 제작하기 위해 먼저 주요 단일 피복재 10종 및 보온재 16종에 대한 열관류율 측정하였다. 또한 피복 및 보온재를 이중 및 삼중으로 다층 설치할 때 열관류율 추정을 위하여 이중 설치시 24조합, 삼중설치 시 59조합에 대한 열관류율을 핫박스를 이용하여 측정하였다. 단일 피복재에서는 PE필름(0.08mm) 대비 PO필름(0.15mm) 이 가장 열관류율이 가장 작고 열절감율이 가장 큰 것으로 나타났다. 단일 보온재에서는 열관류율에서는 외피가 있는 5겹 의 다겹보온커튼이 가장 보온력이 좋은 것으로 나타났다. 또한 단일자재에 대한 열관류율 값과 열저항값을 이용한 피복 및 보온재의 다층설치시의 총 열관류율 값을 산정하였고 실측 값과의 오차를 보정하는 선형회귀식을 도출하였다. 단일재료의 열관류율값에 의한 피복 및 보온재의 다층설치시 열관류율 추정 모형을 개발한 결과 모형평가지수가 0.90(0.5 이상일 때 양호)으로 나타나 추정치가 실측치를 매우 잘 재현 하고 있는 것으로 나타났다. 또한 시험온실을 통한 실증시험결과 예측된 열절감율이 실측치보다 상대오차 2%로 작게 나타나는 것으로 평가되었다. 이러한 연구결과를 기반으로 모바일 기반의 온실 에너지계산 프로그램을 개발하였다. 이 프로그램은 HTML5 표준 웹 기반 모바일 웹 애플리케이션으로 구현하였으며 N-Screen 지원을 통해 다양한 모바일 장치 및 PC 브라우 저에서 동작이 가능하게 제작되었다. 또한 온실 피복(12종) 및 보온재(16종)의 조합별 열관류율 및 난방부하계수를 제공 하여 농민이 모바일로 온실 위치, 형태 및 피복·보온재 등을 반영한 최대 주야간 냉난방부하 및 기간 난방부하를 산정할 수 있다. 대상 온실의 에너지 소비량에 대한 평가가 가능하며 온실의 지역 및 형태에 따라 피복 및 보온재의 최적 선택으로 에너지 절감형 온실 설계가 가능할 것으로 판단되었다.
        4,000원
        4.
        2019.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the cooling and heating amount, temperature, flow rate of turbine type heat meter for water source heat-pump system were experimentally investigated at the standard operating conditions. The obtained cooling and heating capacity from the heat meter were deviated within 5.0%, 3.8% comparing with the precise values calculated from an accredited test facility. Even though the accumulated cooling and heating amount values of the heat meter had a small difference comparing with the precise values, the temperatures of heat meter showed greatly different values comparing with the precise temperature. Therefore, it is highly recommended to develop the heat meter which is appropriate for the water source heat pump systems.
        4,000원
        5.
        2019.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Experiments of local cooling and heating on crown and root zone of forcing cultivation of strawberry ‘Seolhyang’ using heat pump and root pruning before planting were conducted. During the daytime, the crown surface temperature of the crown local cooling treatment was maintained at 18 ~ 22oC. This is suitable for flower differentiation, while those of control and root zone local cooling treatment were above 30oC. Budding rate of first flower clusters and initial yields were in the order of crown local cooling, root zone local cooling and control in root pruning plantlet and non pruning plantlet, except for purchase plantlet. Those of root pruning plantlet were higher than those of non pruning plantlet. These trends were evident in the yield of the first flower cluster until February 14, 2018, and the effect of local cooling and root pruning decreased from March 9, 2018. The budding rates of the second flower cluster according to the local cooling and root pruning treatments were not noticeable compared to first flower cluster but showed the same tendency as that of first flower cluster. In the heating experiment, root zone local heating(root zone 20oC+inside greenhouse 5oC) and crown local heating(crown 20oC+inside greenhouse 5oC) saved 59% and 65% of heating fuel, respectively, compared to control(inside greenhouse 9oC). Considering the electric power consumption according to the heat pump operation, the heating costs were reduced by 55% and 61%, respectively.
        4,000원
        7.
        2018.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we have investigated the optimal control method and the energy saving possibility when the dimming control for lighting and the suspended particles display(SPD) glass for window were applied to reduce the lighting load and the cooling load in office buildings. Simulations were carried out during from 8:00 am to 7:00 pm of typical one day on summer, winter and intermediate season. Simulation results showed that the cooling and lighting energy usage was reduced to 21.2% compared to the baseline model. Therefore, it was possible to predict the optimum control method of the suspended particles display(SPD) window to control the transmittance for energy saving and the dimming control for lighting during summer season.
        4,000원
        8.
        2018.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        온실의 냉난방부하 산정을 위해 설계자가 선택해야할 주요 변수들에 대하여, 이들 설계 변수가 냉난방부하에 미치는 영향을 평가하기 위해서 각각의 설계 변수값을 변화시키면서 시뮬레이션을 실시하였으며, 이를 바탕으로 특별히 선택에 주의를 기울여야 할 설계 변수를 제안하였다. 난방부하에 가장 큰 영향을 미치는 설계 변수는 피복재의 열관류율이고, 다음으로 설계외기온인 것으로 나타났다. 연동수에 따른 설계 변수의 영향은 차이가 거의 없는 것으로 나타났다. 단동 온실의 경우에는 지중전열 관련 설계 변수의 영향을 무시할 수 없을 것으로 생각되지만, 연동 온실의 경우에는 지중전열 관련 변수 및 틈새환기율의 영향이 미미한 것으로 판단되었다. 냉방부하에 가장 큰 영향을 미치는 설계 변수는 온실내로 유입되는 일사량과 증발산계수이고, 다음으로 실내외 기온차, 환기율인 것으로 나타났다. 설계 변수의 영향은 단동 온실과 연동 온실에서 큰 차이를 보였으나, 연동수에 따른 차이는 거의 없는 것으로 나타났다. 피복재의 열관류율은 단동 온실이나 연동 온실 모두 영향이 미미한 것으로 나타났지만, 실내외 기온차 및 환기율의 경우에는 냉방부하에 미치는 영향을 무시할 수 없을 것으로 생각되며, 특히 연동 온실에서 그 영향이 더 큰 것으로 판단되었다. 냉방부하를 산정할 때 실내 목표온도를 낮게 설정할수록 설계 변수의 선택에 신중해야 한다. 특히, 실내 목표온도를 외기온 보다 낮게 설정하면 환기율 및 열관류율 값이 냉방부하를 증가시키는 방향으로 바뀌므로 더욱 주의해야 한다. 환기율이 낮을 때는 설계 변수 중 설계일사량과 증발산계수의 선택에 주의해야 하고, 환기율이 높을 때는 실내 설정온도와 설계외기온의 선택에 신중을 기해야 한다.
        4,000원
        9.
        2018.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        온실 냉난방시스템 설계용 외부기상조건의 분석 기준을 설정하기 위하여 연간 백분위 방식에 의한 냉난방 설계기온을 분석하고, 기존의 계절 백분위 방식에 의한 설계기온과 비교 검토하였다. 우리나라 전 지역을 대상으로 현재 기상청에서 제공하는 기후평년값 기준 30년간의 매 시각 기상자료를 분석에 사용하였다. 표준기상 데이터의 이용이 제한적이기 때문에 전체 기상자료를 이용하여 매년 설계용 기상조건을 구하고, 전체 자료기간의 평균값을 분석에 사용하였다. 연간 백분위 방식으로 1년 기준 총 8,760시간의 백분위수 0.4%, 1%, 2%를 냉방 설계 외기온으로, 99.6%, 99%를 난방 설계 외기온으로 제시하였다. 연간 백분위 방식을 채택할 경우 계절 백분위 방식에 비하여 전체적으로 난방설계 외기온은 6.7~9.6% 상승하는 것으로 나타났으며, 냉방설계 외기온은 0.6~1.1% 하강하는 것으로 나타났다. 동일한 온실 조건에서 최대난방부하는 연간 백분위 방식을 채택할 경우 기존의 계절 백분위 방식에 비하여 약 3.0~3.6% 정도 감소하는 것으로 나타났고, 최대냉방부하에 미치는 영향은 미미한 것으로 분석되었다. 따라서 난방설계 외기온은 연간 백분위 방식으로의 변경에 대하여 고려할 필요가 있지만, 냉방설계 외기온은 두 방법 간의 차이가 거의 없으므로 아직까지 변경할 필요는 없는 것으로 판단된다. 전체적으로 현재의 계절 백분위 방식으로 분석한 설계 외기온을 사용하여도 큰 문제는 없을 것으로 생각되지만, 기후변화의 영향을 고려하여 주기적인 설계용 기상자료의 분석 및 설계기준의 개정이 필요하고, 현재의 기후평년값 기준연도가 바뀌는 2021년 이후에는 이 기간의 기상자료를 분석하여 새로운 설계기준으로 제공해야 할 것이므로, 그 때 연간 백분위 방식에 대한 전문가 그룹의 검토를 통하여 반영할 필요가 있을 것으로 판단된다.
        4,000원
        10.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 4연동 벤로형 유리온실의 냉·난방 부하를 고려한 PV 시스템의 적정 패널 설치 면적을 도출하기 위하여 BES 기법을 이용하여 온실 및 PV 시스템의 에너지 모델을 설계하였으며 동적 에너지 시뮬레이션을 수행하였다. 대상 작물은 파프리카로 선정하였으며 작물의 적정생육온도를 고려하여 냉·난방장치 및 환기장치의 가동조건을 설정하였다. 2012년부터 2016년까지 총 5년 동안의 기간별 냉·난방부하 및 최대 냉·난방 부하를 환 기팬의 환기량 조건 별로 분석을 실시하였다. 온실의 냉 ·난방 부하 산정과 함께 PV 시스템의 설치 각도에 따른 전력 생산량을 분석하였으며 신재생에너지 공급의무비율을 적용하여 최적 PV 시스템 설계 방안을 도출하였다. 환기팬의 환기량 60AE·hr-1 조건에서 대상 온실의 기간 평균 냉방 부하로 인한 전력 소모량은 174,310kWh, 기간 평균 난방 부하로 인한 전력 소모량은 458,903kWh 로 총 633,213kWh의 전력 소모량이 산정되었다. PV 시스템은 설치 각도를 30o로 설정하는 조건에서 가장 높은 전력 생산량이 나타났으며 월별 최적 각도를 적용하는 조건에서는 고정형 PV 시스템보다 약 5.7% 많은 전력 을 생산하는 것으론 산정 되었다. 최종적으로 대상 온실에 적합한 PV 시스템 패널 면적을 도출한 결과, 고정형 PV 시스템은 521m2의 패널이 필요한 것으로 산정되었고, 가변형 PV 시스템의 경우 494m2의 패널이 필요한 것으로 산정되었다. 본 연구를 통하여 4연동 벤로형 유리온실의 냉·난방 부하를 고려한 PV 시스템의 필요 패널 설치 면적을 도출할 수 있었으며 PV 시스템의 온실 적용 가능성 및 경 제성 평가의 기초 자료로 활용 가능할 것으로 판단된다. 한편, 본 연구에서는 작물 특성 데이터를 확보하지 못하여 작물의 에너지 교환을 고려하지 않았다. 보다 정확한 결과를 도출하기 위해서는 현장 실험 데이터에 기반을 둔 추가 연구가 필요할 것으로 판단된다.
        4,000원
        11.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The Air-shiter is a new product possible ventilation at the same time cooling or heating with combined refrigerator and heat recovery ventilator. And a key device of this system is the air shifter. The air shifter device is to convert the outdoor air, room air, supply air and exhaust air flow. Therefore, an experimental study has been carried out to investigate the operating performance for this system. The results, it is possible to ventilate at the same time of heating by outside air above 30℃ in summer. and of heating by outside air within 3℃ in winter. The indoor discharge temperature is over 40℃, and the coefficient of performance is 3.4 in winter.
        4,000원
        12.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Warpage of injection molded product is caused by non-uniform shrinkage and residual stress. A method of removing uneven molding shrinkage and residual stress is to remove the defective factor to Uniform cooling of products. Warpages for part designs have been investigated in this study according to the injection molding conditions for amorphous ABS and crystalline PP by the rapid cooling and heating system. Experimental results showed that the crystalline resin was more warped than amorphous resin, Warpages have been observed in the regions of the part, near gate region and flow direction region.
        4,000원
        13.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        온실의 냉난방시스템 설계 기준에 적용하기 위한 외부 기상조건을 설정하기 위하여 난방 설계용 외기온, 난방 degree-hour, 냉방 설계용 건구온도, 습구온도, 일사량을 분석하여 제시하였다. 우리나라 전 지역을 대상으로 현재 기상청에서 제공하는 기후평년값 기준인 1981~2010 년까지 30년간의 매 시각 기상자료를 분석에 사용하였다. 표준기상데이터의 이용이 제한적이기 때문에 30년간의 전체 기상자료를 이용하여 설계용 기상조건을 구하고, 전체 자료기간의 평균값을 설계기준으로 제시하였다. TAC 방식으로 위험률 1, 2.5, 5%에 대한 설계용 기상자료를 분석하고, 설계기준에서 추천하고 있는 난방용은 위험률 1%, 냉방용은 위험률 2.5%의 기상조건 분포도를 제시하였다. 지역별, 위험률별 및 설정온도별로 최대난방부하, 기간난방부하 및 최대냉방부하의 변화를 고찰하였다. 제시된 각종 설계용 기상조건은 온실의 냉난방시스템 설계에 직접 이용할 수 있을 뿐만 아니라 냉난방 설비 보강이나 에너지 절감대책의 수립에 활용이 가능할 것으로 판단된다. 한편 기후변화로 인하여 최근 여름철 폭염이나 겨울철 이상고온 현상이 자주 발생하고 있으므로 주기적인 설계용 기상자료의 분석이 필요하고, 최소한 10 년 주기로 설계기준을 개정할 필요가 있는 것으로 생각 된다. 본 연구에서는 현재 기후평년값 기준인 1981 ~2010년까지의 기상자료를 분석하였으나 이 기준이 1991~2020년으로 바뀌는 2021년에는 즉시 이 기간의 기상자료를 분석하여 새로운 설계기준으로 제공해야 할 것으로 판단된다.
        4,300원
        14.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A new design concept for integrated thermal energy storage system is suggested to increase energy saving rate for heating and cooling system of the closed glass greenhouse. Heat pump of air source is installed in the mechanical room and air flows then controlled by damper system located between the greenhouse and outdoor environments. A damper control algorithm is designed to enhance the usage of excessive energy in the glass greenhouse. Since the proposed system is installed at the actual glass greenhouse site for experimental verification of energy savings, the proposed system with damper control is compared with conventional greenhouse heating and cooling system. From results, it is found that more than 10% increase of energy saving rate is achieved.
        4,000원
        15.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 BES 기법을 활용하여 온실을 대상으로 실시간 에너지교환 시뮬레이션 모델 개발 및 검증을 수행하고 냉·난방부하 산정 및 경향성을 분석하였다. 우선 BES 기법과 현장실험을 기반으로 온실의 실시간 에너지 교환 모델을 개발하였다. 광흡수율, 엽면적지수, 잎 특성 길이 등 대상작물인 애플망고의 특성 값들과 온실 내부 이산화탄소 농도, 광량, 온도 등 실시간 입력 자료를 고려하여 작물 및 토양의 에너지교환을 구현하였다. 모델의 검증은 온실 내부 기온으로 수행하였으며 실측 내부 기온과 연산된 내부 기온 간의 결정계수, 일치도로 평가 하였다. 내부 기온 비교는 결정계수 0.89, 일치도 0.93으로 높은 유사성을 확인하였으며 모델의 유의성을 판단하였다. 개발한 모델과 2005년부터 2014년까지의 기상자료, 대상작물의 생육단계별 적정생육온도를 이용하여 대상온실의 냉·난방부하 산정하였다. 연도별 냉·난방부하산정 및 경향성을 파악하였으며 최대 냉·난방부하 산정을 통하여 대상온실의 냉·난방장치 용량설계의 기초자료를 확보하였다. 최근 10년 치 기상자료를 통하여 평균 최대 난방부하 525,473 kJ·hr-1, 평균 최대냉방부하 630,870 kJ·hr-1가 산정되었으며 대상 온실에 지열, 온배수, 태양열 등 신재생에너지를 활용할 경우 유용하게 활용될 것으로 판단된다. 본 연구를 통하여 온실 내 각 구성요소 간의 실시간 에너지교환을 모의할 수 있었으며 추후 온배수 활용을 위한 저류조, 히트펌프, 축열조 등의 설비를 구현함에 따라 전반적인 냉·난방 시스템의 구현 가능성을 확인하였다. 또한 동적 해석방법을 통하여 재배작물, 생육단계 및 토양을 고려하였으며 온실 에너지교환 모델에 다양한 형태로 적용 가능할 것으로 판단된다.
        4,000원
        16.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was developed the rapid heating and cooling device using peltier module for uniform cooling. make the rapid heating and cooling device(RCHD), for traditional water cooling device(TWCD) method and the rapid heating and cooling method warpage were compared and were analyzed and the materials used crystalline PP polymer. various warpage were compared for the process parameters such as packing pressure, packing time, mold temperature. in the crystalline PP polymer, TWCD method has higher warpage than RCHD method and show the result to be a bit more uniform cooling. RCHD method has higher warpage than TWCD method as cooling time and packing time increases and TWCD method has higher warpage than RCHD method as mold temperature increases.
        4,000원
        17.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The Air-shiter is a new products possible ventilation at the same time cooling or heating with integrated refrigeration and ventilation units. and is a key component of the air shifter devices and bypass damper. The air shifter devices are to convert the outdoor air, room air, supply air and exhaust air flow. And the bypass damper is device to determine a ventilation. After research and development of these systems were as follows. It is confirmed that the Air-shiter is possible ventilation at the same time cooling or heating, and outdoor air cooling in the spring or fall.
        4,000원
        18.
        2014.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        기상청에서 제공하는 전체 기상자료와 평년값 자료 및 태양에너지학회에서 제공하는 표준기상데이터를 이용하여 위험률별 난방설계용 외기온과 상대습도, 냉방설계용 건구온도, 습구온도 및 일사량 자료를 분석하였다. 표준 기상데이터는 평균에 가장 가까운 대표성을 갖는 1개년의 데이터로 가공 처리한 매시간별 기상자료이고, 평년 값 자료는 30년(1981~2010년) 평균 일별 기상자료이며, 전체 기상자료는 평년값과 동일기간의 매시간별 기상자료이다. 일부 분석방법은 평년값 자료를 이용하는 경우도 있지만 대부분 매시간별 기상자료가 필요하고 대표성을 갖기 위해서는 표준기상데이터를 이용하는 것이 가장 적합하다. 그러나 현재 표준기상데이터는 서울과 6대 광역시 등 7개 지역만 제공되고 있기 때문에 전국을 커버 할 수 있는 지역별 온실 환경설계용 기상자료의 구축에는 전체 기상자료를 이용할 수밖에 없다. 따라서 본 연구에서는 표준기상데이터가 제공되고 있는 7개 지역을 대상으로 전체 기상자료 및 평년값 자료를 이용한 방법으로 분석하여 표준기상데이터로 구한 값과 비교 검토하였다. 위험률별 설계 기상자료는 전체 기상자료를 이용하여 구한 평균값이 표준기상데이터로 구한 결과와 잘 일치하였다. 따라서 표준기상데이터가 없는 지역의 위험률별 설계용 기상자료는 전체 기상자료를 이용하여 구하고, 전체자료 기간의 평균값을 온실의 환경설계 기준으로 사용하며, 최대값과 최소값을 제공함으로써 참고자료로 활용할 수 있도록 하는 것이 합리적인 방법으로 판단된다. 최근의 기후변화 문제로 냉난방 설계기온의 지 속적인 변화가 예상되므로 이에 대응하기 위해서는 전문 가들로 구성된 온실설계위원회와 같은 기구의 설치가 절실히 요청된다. 위원회에서는 자료기간 및 분석방법에 대한 기준을 설정하고, 최소한 10년 간격의 정기적인 검토를 통하여 기상자료를 분석하고 온실설계기준 및 가이드라인을 제공할 필요가 있다.
        4,000원
        19.
        2014.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The Laplace Transform solution is used as a mathematical model to analyse the thermal performance of the building constructed using different wall materials. The solution obtained from Laplace Transform is an analytical solution of an one dimensional, linear, partial differential equation for wall temperature profiles and room air temperatures. The main purpose of the study is showing the detail of obtaining solution process of the Laplace Transform. This study is conducted using weather data from two different locations in Korea: Seoul, Busan for both winter and summer conditions. A comparison is made for the cases of an onoff controller and a proportional controller. The weather data are processed to yield hourly average monthly values. Energy consumption load is well calculated from the solution. The result shows that there is an effect of mass on the thermal performance of heavily constructed house in mild weather conditions such as Busan. Building using proportional control experience a higher comfort level in a comparison of building using on-off control.
        4,000원
        20.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        외부공기 유입방식에 따른 느타리버섯의 생육특성을 조사하기 위하여 3가지 처리구를 두어 실험한 결과 모든 처리구에서 재배기간 중 온도편차가 발생하였고, 처리구 모두 1, 2, 8월에 가장 높았으며, T2(열교환기)와 T3(기밀실)에서 T1(외부공기 직접유입) 보다 온도편차가 작은 경향이었다. 재배기간 중 냉방시간은 T1(외부공기 직접유입)은 1,090.3시간, T2(열교환기)는 661.1시간, T3(기밀실)은 865.0시간이었고,평균 냉방절감율은 T1(외부공기 직접유입) 대비 T2(열교환기)는 21%, T3(기밀실)은 11%이었다. 재배기간 동안 난방기의 년중 가동시간은 T1(외부공기 직접유입)은 1,506.9시간, T2(열교환기)는 875.6시간,T3(기밀실)은 1,054.2시간으로 T2의 가동시간이 가장 작았고, 년중 평균 난방절감율은 T1(외부공기 직접유입) 대비 T2(열교환기)는 22%, T3(기밀실)은16%이었다. 외부공기 유입방식에 따른 냉방정도(CD-H)는 T1(외부공기 직접유입)>T3(기밀실)>T2(열교환기)의 순이었고, 난방정도(HD-H)도 냉방정도(CD-H)의 경우와 동일하였다. 수량은 T2(열교환기)와 T3(기밀실)에서 T1(외부공기 직접유입) 보다 4,9, 10월을 제외한 전 기간에서 높았다.이와 같은 결과로 시설재배사에서 느타리버섯 병재배시 열교환기 또는 기밀실을 설치하여 재배할 경우에너지를 절감할 수 있고, 수량 및 고품질의 느타리버섯을 수확할 수 있어 농가소득증대에 기여할 것으로 판단되었다.
        4,000원
        1 2