The Korea Laboratory Accreditation Scheme (KOLAS) is the national accreditation body responsible for providing accreditation services to testing and calibration laboratories. The primary objective of KOLAS is to promote the quality and reliability of laboratory testing by providing nationally and internationally recognized accreditation services. Laboratories accredited by KOLAS are required to meet rigorous international standards set by the International Organization for Standardization (ISO) and are subject to regular assessments to ensure ongoing compliance with the standards. KOLAS accreditation is highly regarded both domestically and internationally, and is recognized for providing high-quality and reliable testing services. The nuclear analysis laboratory at KINAC has been working to establish a quality management system to ensure the external reliability of analytical results and to secure its position as an authorized testing agency. To achieve this, a detailed manual and procedure for nuclear material analysis were developed to conform to the international standards of ISO/IEC 17025. This study presents the preparation process for establishing the management system, focusing on meeting technical and quality requirements for the implementation of the ISO/IEC 17025 standard in the KINAC nuclear analysis laboratory, specifically in the field of chemical testing (dosimetry, radioactive, and neutron measurement subcategories). The preparation process involved two tracks. The first track focused on satisfying technical requirements, with Thermal Ionization Mass Spectrometer (TIMS) and Inductively Coupled Plasma-Mass Spectrometer (ICP-MS) selected as the major equipment for analysis. Analytical methods for determining isotope ratios and concentrations of nuclear materials were determined, and technical qualification was ensured through participation in proficiency test programs, inter-experimenter comparison tests, and uncertainty reports. The second track focused on developing the quality system, including quality manuals, procedures, and guidelines based on the requirements of the ISO/IEC 17025 standard. Various implementation documents were produced during the six-month pilot period, in accordance with the three levels of documents required by the standard. Implementation of ISO/IEC 17025 is expected to have a systematic quality management process for the analysis lab’s operations and to increase confidence in KINAC’s nuclear analysis.
IEC 60079-10-1 edition 2.0, the global standard for hazardous area classification, was newly revised in 2015. There are many differences compared to the previous edition 1.0 version, first released in 2008, so it has caused confusion in the industry. In case of edition 1.0, the hazardous area extent can be derived through the mathematical formula, but in case of edition 2.0, there was the problem that the exact hazardous area extent was not known because of the mathematical formula of the plot for applying the hazardous area extent was not presented. In this study, we converted the plot introduced in edition 2.0 to CAD format and derived the plot as the mathematical equations. Through this, we suggest the hazardous area extent formula of three states (heavy gas, diffusive, jet). As the IEC committee did not provide the mathematical formula of the hazardous area extent according to the release characteristic, it is impossible to apply the exact hazardous area extent. In this study, a mathematical approach was derived for the plot introduced in edition 2.0, which can reduce the confusion of the applying hazardous area extent.
이온교환막은 전기투석, 연료전지 외에도 수처리 공정에 있어 관심도가 매우 높다. 본 연구에서는 이온교환막에 사용되는 이온교환수지를 대신할 물질로써 입자를 제조하였다. 나노단위의 입자가 표면적을 증가시켜 기존의 이온교환수지보다 더 높은 이온교환능이 기대된다. 단분산된 나노크기의 입자를 제조하여 양이온은 -NH3+,-NR3+,-PR3+,-SR2+등의 관능기를 그리고 음이온은 –SO3-,-COO-,-PO3-,-C6H4O- 등의 관능기를 도입함으로써 각각 양전하와 음전하로 높게 하전시킬 수 있다. 입자를 제조하고 이에 따른 제타전위를 측정하고 IEC, FT-SEM, TGA 및 FT-IR을 측정하여 특성을 파악하였다.
For the sustainable development, companies are making a lot of efforts such as activities of sales increase and cost reduction. Among these, efforts to use limited resources efficiently and effectively is still being made steadily. And many methods for management innovation are being introduced and used. However there were partial or temporary effects only. So there are not enough to achieve operations performance to cover the entire system. Therefore, in order to maximize performance or to improve sustainability across the companies, it is necessary to rebuild the existing system with process perspective not with existing functional perspective. This study was performed to achieve the objective that is operation performance improvement of certification body. So literature review was researched and analyed about the process innovation and the process approach. And basic model which is compatible with ISO/IEC 17021 requirement for the certification body was established in this study. Based on this model, one of the certification body was selected and operation system for this organization was established, documented and implemented through the process approach method. In the result, operations performance of certification body on the side of efficiency and effectiveness is analyzed and the effect of reconstruction of system on operations performance was figu
Recently, 18F-FDG PET based CT scan was a critical examination that the after, before plan diagnosis and treatment of tumors. But, due to the distortion of SUV that should be proportional to the metabolic rate of glucose in the tumor, the other measurement methods are being on study. In this study, compared the degree of distortion of SUV that according to the volume of the tumor analysis ROI and VOI using the NEMA IEC Phantom. The results, the SUVmax, mean value are rapidly decreased with threshold value 500 mm2 interval of the ROI analysis, 1500 mm3 interval of the VOI analysis. When compared SUVmax value SUVmean, ROI and VOI analysis VOI measurements was 1.077 times higher SUVmax was 0.981 times highe compared to the value of the ROI measurement. Compare MTV, SUV 2.0 as measured by the volume of the VOI to Volume showed a slightly higher results(Volume / MTV = 93.4 % ±14.8 %). Considering the above results, Tumor evaluation by 18F-FDG PET / CT scan Consider each threshold value should be analyzed due to larger SUV's Distortion depending on the size of the tumor. VOI analysis is recommended. because it showed the VOI analysis is higher than the ROI analysis SUVmax and lower SUVmean due to VOI analysis than once as a measure of the wider area as measured ROI analysis. MTV (R2 = 0.999), a result close to the actual size of the tumor. but, more research is needed in this regard, because SUV according to the standards of value are affected.
First introduced in 1962, LED(light-emitting diodes) emitted low-intensity red light, but modern versions are now available across the ultraviolet, visible, and infrared spectrum, many with very high luminance or brightness. As a result, growing importance of potential safety harzards for human. Now when certificated of CE provide that testing through IEC/EN 62471 for any lamp. Korea standard adopted as it IEC 62471:2006, Photobiological safety of lamps and lamp systems without change, but effectiveness is incomplete. In this paper, we introduce analysis and direction that urgently come into effectiveness of KS C IEC 62471 as a national standard specifications.
국내의 많은 기업들은 품질경영시스템인 ISO 9000 시리즈와 식스시그마 등 기업의 품질 및 제품에 대한 품질을 높이기 위해 품질관리, 품질경영에 많은 시간과 비용을 들여왔다. 하지만 품질인증제도와는 달리 제품의 신뢰성에 관한 경영시스템인증을 받 으려고 하는 기업은 거의 없는 실정이다. 부품·소재나 제품의 신뢰성을 확보하기 위한 방안으로써 신뢰성경영시스템에 대한 인증은 필수적이라 할 수 있다. 신뢰성 관련 기 법들을 표준화하고, 효율적인 경영시스템을 도입하여 운영하고, 여기에 세계적으로 통 용되는 기술체계를 도입하여 기업의 신뢰성경영시스템을 발전시킨다면 우리산업이 당 면한 수출 경쟁력 확보 등의 현안문제 해결에도 도움이 될 수 있다. 본 연구에서는 신 뢰성 경영시스템 인증제도 수립에 있어 국제 표준인 신뢰성경영시스템 IEC 60300에 대해 소개하고, 신뢰성 경영시스템 평가방법을 활용한 MIR기법과 AHP기법을 분석 비 교하고, 개선방향을 제시하고자 한다.
It is hot issue to get the competitiveness of product through reliability-growth as well as availability and safety in almost high-technology industry including military, chemistry, nuclear, telecommunication, transportation service and so on. In advanced countries, they experienced remarkable growth based on reliability technology in materials&parts industry as well as high-tech industry. It has become a symbol of national competitiveness and created a higher value added. This paper is taking on effectively developing ways to deploy IEC 60300 dependability management system and the base technology that are needed to improve competitiveness of industries in Korea.
It is hot issue to get the competitiveness of product through reliability-growth as well as availability and safety in almost high-technology industry including military, chemistry, nuclear, telecommunication, transportation service and so on. In advanced countries, worldwide leading companies have tried to improve and develop high-reliability product as well as reliability management system(IEC60300). We investigate reliability certification systems for product and management system. Additionally, we study the feasibility on the adoption of dependability management system(IEC60300) by empirical survey on companies with product-reliability certification(R-mark) in Korea.
IEC 60300 series, the international standards on reliability management system are newly developed and introduced rapidly worldwide. In order to meet this fast-changing situation, it is necessary to apply them to the Korean industries effectively. It includes the establishment of the infrastructure such as documentation of Korean Standards, introduction of test equipments and test manuals, accreditation of the certification bodies and training of the specialists etc. IEC 60300 is upgraded management system of the ISO 9000 and ISO 14000. In this regard, the Korean companies which were certified with the ISO 9000 or 14000 should endeavor to find new strategies and methods to be certified with IEC 60300. This paper introduces a Quantitative method of estimating the level of the reliability management system by applying the MIR(Maturity Index on Reliability) technique. This enables the estimation of the operation level of the system and can upgrade the maturity level of it.
IEC 60300 series, the international standards on reliability management system are newly developed and introduced rapidly worldwide. In order to meet this fast-changing situation, it is necessary to apply them to the Korean industries effectively. It includes the establishment of the infrastructure such as documentation of Korean Standards, introduction of test equipments and test manuals, accreditation of the certification body and training of the specialists etc. IEC 60300 is upgraded management system of the ISO 9000 and ISO 14000. In this regard, the Korean companies which was certified with the ISO 9000 or 14000 should endeavor to find new strategies and methods to be certified with ISO 60300. This paper introduces a quantitative method of estimating the level of the reliability management system by applying the MIR(Maturity Index on Reliability) technique. This enables the estimation of the operation level of the system and can upgrade the maturity level of it.
The purpose of this study is to carry out comparative analysis of the differences between the trend of biometrics-related system(security) standardization in the world and that of Korea, and to suggest ideal directions and building plans for domestic biometrics industry. Its purpose also includes constructing promptly a standardization of domestic biometrics industry based on the suggested standards.
IEC 60300의 국제 규격은 시간종속성 경영 시스템의 규격으로써 제 1부는 시간종속성 경영 프로그램, 제 2부는 시간종속성 프로그램 구성요소와 업무, 제 3부는 응용지침 표준의 13개의 규격으로 구성되어 있다. 이 규격은 제품의 초기 단계서부터 폐기 단계까지 수명주기 전 단계에 걸쳐 운영의 효율성, 시간, 비용의 제약 하에 위험을 최소화하고 안전성을 최적화하기 위한 지침을 제공한다. 본 연구에서는 현재 2003년 규격 제정을 목표로 개정중인 IEC 60300-1과 IEC 60300-2의 2001년 11월 CDV를 참고로 IEC 규격의 개정방향에 대한 연구를 하려한다.
This paper presents the interrelationship chart between software quality characteristics and engineering attributes. The software quality characteristics and their subcharacteristics are excerpted front IS0/1EC 9126 standards, and the engineering attributes are from Deutsch and Willis[4]. Based on the previous studies and subjective judgement, trisected interrelationship(strong, medium, weak) between these two groups are derived. The results are summarized in a table, and can be used as a quick reference guide to the software quality engineering applications such as quality evaluations for software products, selection of key engineering attributes for high-quality software production, and so forth.
본 연구에서는 IEC 60601-2-54에서 제시한 표준을 근거로 부하조건에서의 제한된 간격으로 걸친 공기커마를 절대측정하여 X선의 직선성을 면밀히 평가하여 다음과 같은 결과를 얻었다.10대를 대상으로 한 모든 진단용 X선 발생장치(DR)는 IEC 60601-2-54 표준에서 제시한 공기커마의 직선성이 부적합으로 나타났고, 일반적인 조사선량의 직선성 평가방법에서는 4대에서 최고 관전압의 50%와 80%의 두 개 측정 계열 모두 부적합으로 나타났으며, 나머지 6대에서는 최고 관전압의 50%와 80%의 두 개 측정 계열 모두에서 적합으로나타났다. IEC 60601-2-54 표준에서 제시한 직선성 시험과 기존의 조사선량 직선성 시험이 많은 차이를 보였다. IEC60601-2-54 표준+에서 제시한 공기커마의 직선성은 국제표준의 권고사항이므로 기존의 조사선량 직선성 보다 상당히 타당성이 있고, 방사선량을 정량화하기 위한 표준으로 IEC 60601-2-54 표준에서 제시한 공기커마의 직선성이 진단용 X선 영상장치 성능관리에 중요한 평가 요소라 사료된다.
IEC and CISPR have continuously endeavored the measurement method of Immunity Test as international unification, but not established yet. The main reason is that the measurement method and the normalization of threshold to obtain the complicated parameters for Immunity Test are difficult. Thus, the Immunity Test Setups are used differently according to the measured electromagnetic environments. This study developed an Immunity Test System and Algorithm for measurement software suitable for IEC801-3 Regulatons using ready-made amplifier, signal generator, and developes interconnecting interface board interacting with other appratus i.e., RF Switch, Power Meter, Field Sensor and Pre-amp. We are to develope an automated software using Top/Down and OOP(Object Oriented Programming) method.
Since the most of the mal-functions in the industrial equipments controlled by processors have been occured by the Electrical Fast Transient(EFT), the International Electrotechnical Commision(IEC) prepare the dummy signal to test the immunity level of the equipments controlled by processors and recommend it for the measuring. In this paper, the defined dummy EFT signal by IEC are analyzed by the spectrum analyzer in the frequency domain and studied the developed countermeasuring parts. The new developed parts are consist of the feedthrough capacitors ( Cy type ) in the input and materials with high permeaility which was wound or inserted in the second layer of the Power Cable in order to increase Common Mode inductance. And it is compared inserted Permalloy to material with high permeability increasing Common Mode inductance. We could gotten a excellent insertion loss on the wide band against EFT signal. Especially, we confirm that countermeasuring Power Cable have been an excellent dynamic characteristics in computer system above the 3.6Kv. This new parts could be effectively used for industrial, MIL, and medical equipments to reduce a mal-functions on the site. Furthermore, these parts also have a good characteristics for EMI countermeasuring over the 60MHz up to several GHz band, they are also expected to be used for all kind of EMS test with IEC801-2, 3, 5 and 6 on the power distributed line.