검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 117

        1.
        2024.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Code-compliant seismic design should be essentially applied to realize the so-called emulative performance of precast concrete (PC) lateral force-resisting systems, and this study developed simple procedures to design precast industrial buildings with intermediate precast bearing wall systems considering both the effect of seismic and blast loads. Seismic design provisions specified in ACI 318 and ASCE 7 can be directly adopted, for which the so-called 1.5S y condition is addressed in PC wall-to-wall and wall-to-base connections. Various coupling options were considered and addressed in the seismic design of wall-to-wall connections for the longitudinal and transverse design directions to secure optimized performance and better economic feasibility. On the other hand, two possible methods were adopted in blast analysis: 1) Equivalent static analysis (ESA) based on the simplified graphic method and 2) Incremental dynamic time-history analysis (IDTHA). The ESA is physically austere to use in practice for a typical industrial PC-bearing wall system. Still, it showed an overestimating trend in terms of the lateral deformation. The coupling action between precast wall segments appears to be inevitably required due to substantially large blast loads compared to seismic loads with increasing blast risk levels. Even with the coupled-precast shear walls, the design outcome obtained from the ESA method might not be entirely satisfactory to the drift criteria presented by the ASCE Blast Design Manual. This drawback can be overcome by addressing the IDTHA method, where all the design criteria were fully satisfied with precast shear walls’ non-coupling and group-coupling strength, where each individual or grouped shear fence was designed to possess 1.5S y for the seismic design.
        4,000원
        2.
        2024.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The design shear strength equations of RC shear walls have been developed based on their performance under in-plane (IP) loads, thereby failing to account for the potential performance degradation of shear strength when subjected to simultaneous out-of-plane (OOP) loading. Most of the previous experimental studies on RC walls have been conducted in one direction under quasi-static conditions, and due to the difficulty in experimental planning, there is a lack of research on cyclic loading and results under multi-axial loading conditions. During an earthquake, shear walls may yield earlier than their design strength or fail unexpectedly when subjected to multi-directional forces, deviating from their intended failure mode. In this paper, nonlinear analysis in finite element models was performed based on the results of cyclic loading experiments on reinforced concrete shear walls of auxiliary buildings. To investigate the reduction trend in IP shear capacity concerning the OOP load ratio, parametric analysis was conducted using the shear wall FEM. The analysis results showed that as the magnitude of the OOP load increased, the IP strength decreased, with a more significant effect observed as the size of the opening increased. Thus, the necessity to incorporate this strength reduction as a factor for the OOP load effect in the wall design strength equation should be discussed by performing various parametric studies.
        4,000원
        3.
        2023.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Structural vibration induced by earthquake hazards is one of the most significant concerns in structure performance-based design. Structural hazards evoked from seismic events must be properly identified to make buildings resilient enough to withstand extreme earthquake loadings. To investigate the effects of combined earthquake-resistant systems, shear walls and five types of dampers are incorporated in nineteen structural models by altering their arrangements. All the building models were developed as per ACI 318-14 and ASCE 7-16. Seismic fragility curves were developed from the incremental dynamic analyses (IDA) performed by using seven sets of ground motions, and eventually, by following FEMA P695 provisions, the collapse margin ratio (CMR) was computed from the collapse curves. It is evident from the results that the seismic performance of the proposed combined shear wall-damper system is significantly better than the models equipped with shear walls only. The scrutinized dual seismic resisting system is expected to be applied practically to ensure a multi-level shield for tall structures in high seismic risk zones.
        4,000원
        4.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목구조에 있어서 횡력에 저항하는 전단벽의 역할은 대단히 중요하다. 특히 이 목조 전단벽은 다양한 수종의 스터드 와 다양한 판재, 접합철물로 제작되어 재료의 성능을 특정하기가 쉽지 않다는 어려움이 있다. 따라서, 구조설계에서 초기단계에 서부터 적용해야하는 경골목조 전단벽의 환산 전단성능값을 미국, 캐나다, 일본 그리고 국내기준의 설정방법을 통하여 파악해 보고자 하였다. 분석결과 국내 경골목구조기준과 소규모 건축기준에서 기본사양으로 제시하고 있는 2×4의 스터드에 두께 11㎜ 의 OSB를 적용한 기본 전단벽의 허용전단력은 3.5~4.5 kN/m의 범위, 또한 환산 전단강성값으로는 1100~1150 kN/m정도로 설계 하는 것이 가능할 것으로 나타났다. 특히, 국내기준은 국외기준에 비하여 상대적으로 큰 전단내력을 허용하고 있는 것으로 나타났고, 현재 기준에서와 같이 북미기 준과 동일한 전단강성을 활용할 경우, 재료의 비선형거동 때문에 실제 변형량을 과소평가할 가능성이 있어, 허용응력의 설정범 위와 전단강성값의 산정기준을 조정하여야 할 필요가 있는 것으로 파악되었다.
        4,000원
        6.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        강진 시 원자력발전시설의 비선형 응답이 중요하기 때문에 이 시설의 내진성능에 대한 관심이 증가하였다. 이 연구에서는 원자력 발전소 철근콘크리트 전단벽의 유한요소해석을 위한 재료모델의 적절한 변수를 제시하였다: 최대인장강도, 팽창각, 손상계수. 이를 위해 상용 유한요소 해석프로그램인 ABAQUS를 사용하여 낮은 형상비를 가진 철근콘크리트 전단벽의 비선형 거동과 전단 파괴모드 에 대한 이 주요 변수의 효과에 대한 연구를 수행하였다. 연구결과에 기반하여 비선형 시간이력해석을 통해 강진 하의 원자로건물의 비선형 응답을 평가하였다.
        4,000원
        7.
        2021.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        KAERI has planned to carry out a series of dynamic tests using a shaking table and time-history analyses for a channel-type concrete shear wall to investigate its seismic performance because of the recently frequent occurrence of earthquakes in the south-eastern parts of Korea. The overall size of a test specimen is ×× 2500 mm×3500 mm×4500 mm, and it consists of three stories having slabs and walls with thicknesses of 140 mm and 150 mm, respectively. The system identification, FE model updating, and time-history analysis results for a test shear wall are presented herein. By applying the advanced system identification, so-called pLSCF, the improved modal parameters are extracted in the lower modes. Using three FE in-house packages, such as FEMtools, Ruaumoko, and VecTor4, the eigenanalyses are made for an initial FE model, resulting in consistency in eigenvalues. However, they exhibit relatively stiffer behavior, as much as 30 to 50% compared with those extracted from the test in the 1st and 2nd modes. The FE model updating is carried out to consider the 6-dofs spring stiffnesses at the wall base as major parameters by adopting a Bayesian type automatic updating algorithm to minimize the residuals in modal parameters. The updating results indicate that the highest sensitivity is apparent in the vertical translational springs at few locations ranging from 300 to 500% in variation. However, their changes seem to have no physical meaning because of the numerical values. Finally, using the updated FE model, the time-history responses are predicted by Ruaumoko at each floor where accelerometers are located. The accelerograms between test and analysis show an acceptable match in terms of maximum and minimum values. However, the magnitudes and patterns of floor response spectra seem somewhat different because of the slightly different input accelerograms and damping ratios involved.
        4,000원
        8.
        2021.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the seismic safety of nuclear power plant structures is evaluated and verified by performing a vibration test on a relatively simple shear wall structure. The shear walls are the prominent members of nuclear power plants and resist the seismic load. The shear wall structure is designed and manufactured to perform shaking table tests and is used to increase the accuracy of the analytical method by comparing them with the numerical analysis results. Different results will be checked and more efficient application methods will be studied depending on the method of designing reinforced concrete structures.
        4,000원
        9.
        2021.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        After the manual shutdown of the Wolseong nuclear power plant due to an earthquake in Gyeongju in 2016, anxiety about the earthquake safety of nuclear power plants has become a major social issue. The shear wall structure used as a major structural element in nuclear power plants is widely used as a major structural member because of its high resistance to horizontal loads such as earthquakes. However, due to the complexity of the structure, it is challenging to predict the dynamic characteristics of the structure. In this study, a three-story shear wall structure is fabricated, and the in-structure response characteristics of the shear wall structure are evaluated through shaking table tests. The test is performed using the Gyeongju earthquake that occurred in 2016, and the response characteristics due to the domestic earthquake are evaluated.
        4,000원
        10.
        2021.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Structures of domestic nuclear power plants are designed to perform elastic behavior against beyond design earthquakes, but studies on the nonlinear behavior of structures have been insufficient since the beyond design earthquake. Accordingly, it is judged that it will be necessary to develop an evaluation method that considers the nonlinear behavioral characteristics to check the safety margin for a standard nuclear power plant structure. It is confirmed that the restoring force characteristics for each member level can be identified through the calculation formula, and the lateral stiffness for each story can also be easily calculated by JEAC 4601. In addition, as a result of applying the evaluation method of JEAC 4601 as a nonlinear restoring force model of the nuclear power plant, a certain degree of safety margin can be identified.
        4,000원
        11.
        2021.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A shear wall is a structural member designed to effectively resist in-plane lateral forces, such as strong winds and earthquakes. Due to its efficiency and stability, shear walls are often installed in residential buildings and essential facilities such as nuclear power plants. In this research, to predict the results of the shaking table test of the three-story shear wall RC structure hosted by the Korea Atomic Energy Research Institute, three types of numerical modeling techniques are proposed: Preliminary, Calibrated 1, and Calibrated 2 models, in order of improvement. For the proposed models, an earthquake of the 2016 Gyeongju, South Korea (peak ground acceleration of 0.28 g) and its amplified earthquake (peak ground acceleration of 0.50 g) are input. The response spectra of the measuring points are obtained by numerical analysis. Good agreement is observed in the comparisons between the experiment results and the simulation conducted on the finally adopted numerical model, Calibrated 2. In the process of improving the model, this paper investigates the influences of the mode shape, material properties, and boundary conditions on the structure's seismic behavior.
        4,000원
        12.
        2021.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The dynamic characterization of a three-story auxiliary building in a nuclear power plant (NPP) constructed with a monolithic reinforced concrete shear wall is investigated in this study. The shear wall is subjected to a joint-research, round-robin analysis organized by the Korea Atomic Energy Research Institute, South Korea, to predict seismic responses of that auxiliary building in NPP through a shake table test. Five different intensity measures of the base excitation are applied to the shaking table test to get the acceleration responses from the different building locations for one horizontal direction (front-back). Simultaneously to understand the global damage scenario of the structure, a frequency search test is conducted after each excitation. The primary motivation of this study is to develop a nonlinear numerical model considering the multi-layered shell element and compare it with the test result to validate through the modal parameter identification and floor responses. In addition, the acceleration amplification factor is evaluated to judge the dynamic behavior of the shear wall with the existing standard, thus providing theoretical support for engineering practice.
        4,000원
        13.
        2021.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Most commercial buildings among existing RC buildings in Korea have a multi-story wall-frame structure where RC shear wall is commonly used as its core at stairways or elevators. The members of the existing middle and low-rise wall-frame buildings are likely arranged in ordinary details considering building occupancy, and the importance and difficulty of member design. This is because there are few limitations, considerations, and financial burdens on the code for designing members with ordinary details. Compared with the intermediate or unique details, the ductility and overstrength are insufficient. Furthermore, the behavior of the member can be shear-dominated. Since shear failure in vertical members can cause a collapse of the entire structure, nonlinear characteristics such as shear strength and stiffness deterioration should be adequately reflected in the analysis model. With this background, an 8-story RC wall-frame building was designed as a building frame system with ordinary shear walls, and the effect of reflecting the shear failure mode of columns and walls on the collapse mechanism was investigated. As a result, the shear failure mode effect on the collapse mechanism was evident in walls, not columns. Consequently, it is recommended that the shear behavior characteristics of walls are explicitly considered in the analysis of wall-frame buildings with ordinary details.
        4,000원
        14.
        2020.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Seismic fragility was assessed for non-seismic reinforced concrete shear walls in Korean high-rise apartment buildings in order to implement an earthquake damage prediction system. Seismic hazard was defined with an earthquake scenario, in which ground motion intensity was varied with respect to prescribed seismic center distances given an earthquake magnitude. Ground motion response spectra were computed using Korean ground motion attenuation equations to match accelerograms. Seismic fragility functions were developed using nonlinear static and dynamic analysis for comparison. Differences in seismic fragility between damage state criteria including inter-story drifts and the performance of individual structural members were investigated. The analyzed building had an exceptionally long period for the fundamental mode in the longitudinal direction and corresponding contribution of higher modes because of a prominently insufficient wall quantity in such direction. The results showed that nonlinear static analyses based on a single mode tend to underestimate structural damage. Moreover, detailed assessments of structural members are recommended for seismic fragility assessment of a relatively low performance level such as collapse prevention. On the other hand, inter-story drift is a more appropriate criterion for a relatively high performance level such as immediate occupancy.
        4,200원
        15.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        초고층 건물의 횡변위 제어를 위하여 사용되는 아웃리거를 기존의 철골 트러스 대신에 철근콘크리트 벽체로 대체할 수 있다. 철근콘크리트 아웃리거 벽체를 외부 기둥에 연결할 경우에는 축력뿐만 아니라 전단력과 모멘트가 외부 기둥에 유발될 수 있다. 본 연구에서는 아웃리거 벽체 외단부의 회전으로 인한 외부 기둥의 전단력을 수식으로 유도하고 그 값을 유한요소해석 결과와 비교하였다. 유한요소해석에서는 층별 연결보의 효과와 전단벽과 아웃리거를 보와 평면응력요소로 모델링한 효과를 분석하였다. 층별 연결보의 효과는 거의 없었으며 평면응력요소는 보요소보다 더 큰 강성을 가진 것으로 해석되었다. 아웃리거 벽체의 외단부 회전으로 인한 외부기둥의 층간 회전각과 전단력은 허용값에 비하여 상당히 작은 값이 발생하였다. 따라서 초고층 건물에 철근콘크리트로 된 아웃리거 벽체를 적용할 경우에도 외부 기둥에 유발되는 전단력과 모멘트에 대하여 별도의 검토를 할 필요는 없을 것으로 판단된다.
        4,000원
        16.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 지진에 저항하는 부재인 비보강 조적벽체로 구성된 건물의 내진성능평가에 활용되는 비선형 정적해석을 위한 비보강 조적벽체의 해석모델을 수립하고자 하였다. 본 연구의 해석모델은 비보강 조적벽체의 휨거동을 모사하기 위한 파이버 요소와 비보강 조적벽체의 전단에 대한 응답을 예측하기 위한 전단스프링 요소로 구성된다. 본 논문은 먼저 제안하고 있는 모델의 형상에 대해서 설명하고, 기존에 행해진 조적조 프리즘의 실험결과로부터 얻은 응력-변형률 곡선을 근거로 파이버와 전단스프링 요소의 물성치에 대한 결정 방법을 설명한다. 제시하고 있는 모델은 비선형 정적 해석결과와 다른 연구자들에 의해 수행된 실험결과를 비교하여 타당성을 검증한다. 해당 모델은 최대강도, 초기강성, 그리고 이들로부터 얻어지는 비보강 조적벽체의 하중-변위 곡선을 적절하게 모사하고 있다. 또한, 해석모델이 비보강 조적벽체의 파괴모드를 예측할 수 있는 것으로 나타난다.
        4,000원
        17.
        2018.04 구독 인증기관·개인회원 무료
        Structural insulated panels, structurally performed panels consisting of a plastic insulation bonded between two structural panel facings, are one of emerging products with a viewpoint of its energy and construction efficiencies. Of the SIPs, Cyclic test was conducted by two kinds of specimens: single panel and double panels. Cyclic test results, which were equivalent to static test results, showed that maximum load was 45.42kN, allowable shear load was 6.3kN/m. Furthermore the accumulated energy dissipation capability for double panels was as 2.3 times as that for single panel. From performance of structural tests, the allowable shear load for panels was suggested to be at least 6.1kN/m.
        18.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, natural period formular is presented for a RC shear wall structure with H-, T-, and L-shaped wall sections. The natural period formular proposed by Goel and Chopra and adopted in ASCE 7-10 was modified by using the ratio of the flange and web wall area. The natural periods of structures with H-shaped wall were numerically obtained, the results indicated that the ASCE 7-10 could not consider the natural period variation according to the length of the flange wall, but the proposed formula could do. Especially, ASCE 7-10 estimated much longer periods than eigenvalue analysis, and this implies that conservative seismic design is difficult. The periods by eigenvalue analysis exist between the upper and lower bounds given by the proposed formula, and conservative design is possible by using the proposed lower bound value. In order to verity the effectiveness of the proposed method, actual residential buildings with various types of flange walls are considered. Ambient vibration tests, eigenvalue analyses, and nonlinear dynamic analyses were conducted and the periods were compared with the values by ASCE 7-10 and the proposed formula. The results showed that the proposed formula could estimate more accurately the periods than ASCE 7-10.
        4,000원
        19.
        2017.04 구독 인증기관·개인회원 무료
        The concrete wall panels are composed of various members such as studs, brackets, bolts and nuts, etc. Embedded studs in the concrete wall resist transferred lateral and horizontal load in the structure. The thickness of the concrete wall influences shear behavior of embedded studs. The finite element analysis was carried out with respect to the thickness of the concrete wall to investigate shear behavior of embedded studs. The numerical analysis results were compared with the experimental results and confirmed that The deformation of the stud anchor is reduced with an increase of the thickness of the concrete wall.
        20.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        When reinforcing an existing reinforced concrete beam-column building with a precast concrete panel, special connection between the PC member and the RC member is required to solve the time dependent deformation of the RC member and to receive the large shear forces. The aim of this study is to obtain the shear strength of upper connection between the existing RC beam-column and infilled PC wall panels in experimentally and theoretically. Thus, the static shear loading tests were conducted on the 6 specimens with the plate connection. Shear failure was resulted from the weakest portion of interior PC panel, exterior RC, and the connection, when the PC portion which located at the center of specimen was pulled upward from the bottom. T he experimental result was compared with analytical result from ACI 318M-14 Chapter 17 for the shear strength of post-installed anchor and PCI Handbook 7th edition 6.8 Structural Steel Corbel (PCI Design Handbook 7th edition, 2010) for the strength of cast-in H-beam. The analytical and experimental results show final failure at the same location. The failure loading of experiment showed larger than average 6% to that of the analysis.
        4,500원