        2024.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Code-compliant seismic design should be essentially applied to realize the so-called emulative performance of precast concrete (PC) lateral force-resisting systems, and this study developed simple procedures to design precast industrial buildings with intermediate precast bearing wall systems considering both the effect of seismic and blast loads. Seismic design provisions specified in ACI 318 and ASCE 7 can be directly adopted, for which the so-called 1.5S y condition is addressed in PC wall-to-wall and wall-to-base connections. Various coupling options were considered and addressed in the seismic design of wall-to-wall connections for the longitudinal and transverse design directions to secure optimized performance and better economic feasibility. On the other hand, two possible methods were adopted in blast analysis: 1) Equivalent static analysis (ESA) based on the simplified graphic method and 2) Incremental dynamic time-history analysis (IDTHA). The ESA is physically austere to use in practice for a typical industrial PC-bearing wall system. Still, it showed an overestimating trend in terms of the lateral deformation. The coupling action between precast wall segments appears to be inevitably required due to substantially large blast loads compared to seismic loads with increasing blast risk levels. Even with the coupled-precast shear walls, the design outcome obtained from the ESA method might not be entirely satisfactory to the drift criteria presented by the ASCE Blast Design Manual. This drawback can be overcome by addressing the IDTHA method, where all the design criteria were fully satisfied with precast shear walls’ non-coupling and group-coupling strength, where each individual or grouped shear fence was designed to possess 1.5S y for the seismic design.
        4,000원
        2.
        2023.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Structural vibration induced by earthquake hazards is one of the most significant concerns in structure performance-based design. Structural hazards evoked from seismic events must be properly identified to make buildings resilient enough to withstand extreme earthquake loadings. To investigate the effects of combined earthquake-resistant systems, shear walls and five types of dampers are incorporated in nineteen structural models by altering their arrangements. All the building models were developed as per ACI 318-14 and ASCE 7-16. Seismic fragility curves were developed from the incremental dynamic analyses (IDA) performed by using seven sets of ground motions, and eventually, by following FEMA P695 provisions, the collapse margin ratio (CMR) was computed from the collapse curves. It is evident from the results that the seismic performance of the proposed combined shear wall-damper system is significantly better than the models equipped with shear walls only. The scrutinized dual seismic resisting system is expected to be applied practically to ensure a multi-level shield for tall structures in high seismic risk zones.
        4,000원
        3.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목구조에 있어서 횡력에 저항하는 전단벽의 역할은 대단히 중요하다. 특히 이 목조 전단벽은 다양한 수종의 스터드 와 다양한 판재, 접합철물로 제작되어 재료의 성능을 특정하기가 쉽지 않다는 어려움이 있다. 따라서, 구조설계에서 초기단계에 서부터 적용해야하는 경골목조 전단벽의 환산 전단성능값을 미국, 캐나다, 일본 그리고 국내기준의 설정방법을 통하여 파악해 보고자 하였다. 분석결과 국내 경골목구조기준과 소규모 건축기준에서 기본사양으로 제시하고 있는 2×4의 스터드에 두께 11㎜ 의 OSB를 적용한 기본 전단벽의 허용전단력은 3.5~4.5 kN/m의 범위, 또한 환산 전단강성값으로는 1100~1150 kN/m정도로 설계 하는 것이 가능할 것으로 나타났다. 특히, 국내기준은 국외기준에 비하여 상대적으로 큰 전단내력을 허용하고 있는 것으로 나타났고, 현재 기준에서와 같이 북미기 준과 동일한 전단강성을 활용할 경우, 재료의 비선형거동 때문에 실제 변형량을 과소평가할 가능성이 있어, 허용응력의 설정범 위와 전단강성값의 산정기준을 조정하여야 할 필요가 있는 것으로 파악되었다.
        4,000원
        4.
        2021.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        KAERI has planned to carry out a series of dynamic tests using a shaking table and time-history analyses for a channel-type concrete shear wall to investigate its seismic performance because of the recently frequent occurrence of earthquakes in the south-eastern parts of Korea. The overall size of a test specimen is ×× 2500 mm×3500 mm×4500 mm, and it consists of three stories having slabs and walls with thicknesses of 140 mm and 150 mm, respectively. The system identification, FE model updating, and time-history analysis results for a test shear wall are presented herein. By applying the advanced system identification, so-called pLSCF, the improved modal parameters are extracted in the lower modes. Using three FE in-house packages, such as FEMtools, Ruaumoko, and VecTor4, the eigenanalyses are made for an initial FE model, resulting in consistency in eigenvalues. However, they exhibit relatively stiffer behavior, as much as 30 to 50% compared with those extracted from the test in the 1st and 2nd modes. The FE model updating is carried out to consider the 6-dofs spring stiffnesses at the wall base as major parameters by adopting a Bayesian type automatic updating algorithm to minimize the residuals in modal parameters. The updating results indicate that the highest sensitivity is apparent in the vertical translational springs at few locations ranging from 300 to 500% in variation. However, their changes seem to have no physical meaning because of the numerical values. Finally, using the updated FE model, the time-history responses are predicted by Ruaumoko at each floor where accelerometers are located. The accelerograms between test and analysis show an acceptable match in terms of maximum and minimum values. However, the magnitudes and patterns of floor response spectra seem somewhat different because of the slightly different input accelerograms and damping ratios involved.
        4,000원
        5.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 실험 연구의 목적은 횡방향 정적가력을 통하여 2층 R.C 전단벽식 구조의 내진성능을 평가하는 것이다. 본 연구의 실험체는 대상 건물의 개구부를 가지는 T자형 벽체 1층과 2층의 일부분을 대상으로 실물크기의 3/5 크기정도로 축소하였고, 인방보의 유 무를 실험변수로한 2개의 실험체를 제작하여 횡방향의 정적가력 실험을 수행하였다. 인방보 유무에 따른 벽체의 구조적 성능 및 거동의 차이를 비교한 결과, 인방보가 있는 실험체가 인방보가 없는 실험체보다 최대내력과 연성능력 등의 내진성능이 우수한 것으로 판단되었다.
        4,200원
        6.
        2010.03 구독 인증기관 무료, 개인회원 유료
        In this study, a shear wall-slab damper system for seismic retrofitting of existing low-rise school buildings was proposed. The proposed system is to control the earthquake-induced vibration of the existing building structures using the energy dissipation effect of hysteretic damper inserted between the extended shear wall and existing moment frame. The numerical analyses were performed to investigate the vibration control efficiency of the shear wall-slab damper system and to identify the range of optimal yielding strength of the slab damper. In addition, variation of shear force of the extended shear wall with regard to the yield strength of the dampers in a range from 10 to 100 percent of the maximum base shear force of the retrofitted structure was investigated. The numerical analyses results showed that the maximum displacement of the structures with the slab damper whose yield strength is equal to 20 percent of the maximum base shear. On top of that, the slab damper system reduced the shear force of the shear wall by about 50 percent in comparison with the existing frame-shear wall system with rigid diaphragm slabs.
        4,000원
        7.
        2008.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 전단벽-모멘트골조 시스템으로서 전단벽이 주로 횡력을 부담하는 철근콘크리트 건물을 대상으로 다양한 설치형식과 마찰력의 총량 및 분포를 갖는 마찰형 감쇠기의 제진보강 효과를 수치해석을 통해 비교 분석하였다. 감쇠기의 설치형식으로서 전단벽에 인접한 대각가새형, 벽체가 없는 골조를 보강하는 대각가새형 및 벽체 단부를 보강하는 수직경계요소형을 고려하였다. 하중기준 강화로 설계용보다 크게 증가한 지진하중에 대해 건물의 재료비선형성을 고려한 비선형시간이력해석을 수행하여 에너지소산, 횡하중 및 부재손상도 측면에서 마찰형 감쇠기의 제진성능을 비교 분석하였다. 기준마찰력의 30% 수준의 총마찰력을 갖는 벽체보강 대각가새형 설치형식이 전반적으로 가장 우수한 제진성능을 보이며,이 경우에 마찰력 배분방식은 중요하지 않았다. 또한 일부층에 집중설치함으로써 전층설치에 약간 못미치는 제진성능을 얻을 수 있었다.
        4,800원
        8.
        2006.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 민감도 해석을 이용하여 전단벽-골조 구조시스템의 횡변위를 정량적으로 제어할 수 있는 강성최적설계방안을 제시하고자 한다. 이를 위해 먼저 골조와 전단벽요소 사이의 변위자유도 적합성 문제를 해결하기 위한 요소강성행렬을 구성하며, 또한 수학적계획법의 일반성을 유지하면서도 큰 규모의 문제도 효율적으로 다를 수 있는 근사화 재념을 도입하여 횡변위 구속조건식을 설정한다. 아울러 전단벽 및 골조부재의 단면특성 관계식을 설정함으로써 설계변수의 수를 줄여주고, 이를 이용하여 강성행렬도함수의 산정을 용이하게 한다. 특히 골조의 경우 초기에 주어진 단면형상이 최적설계 과정동안 계속 유지된다는 가정을 이용하여 최적설계결과에서 구해진 단면특성에 따라 부재단면크기를 산출하고, 전단벽은 사용자의 의도에 따라 두께 또는 부재길이를 재산정하는 방안을 강구한다. 이와 같이 제시된 강성최적설계기법의 효용성을 검토하기 위해 두 가지 형태의 20층 전단벽-골조 구조물의 예제가 고려된다.
        4,000원
        9.
        2004.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 도심지에 건설되고 있는 대부분의 주상복합건물과 아파트들은 다양한 공간을 구성하기 위해 주로 복합구조형식을 채택하고 있다. 특히, 이러한 구조형식들 중의 하나인 상부벽식-하부골조시스템은 전이층에서 서로 연결되는 전단벽형식과 골조형식을 모두 포함하고 있다. 그러나 이 시스템은 구조적인 안전성 측면에서 볼 때 매우 불합리하며, 전이층에서의 응력분포를 파악하기 매우 어렵다. 따라서 본 연구에서는 연직 및 정적 횡하중이 작용하는 전이보 시스템의 전단벽 배치에 따른 구조적인 거동과 응력분포를 분석하고자 함에 있으며, 또한 해석결과를 바탕으로 전이층부근에서의 하중의 전달경로 및 응력집중현상을 파악하고, 전단벽과 전이보의 효율적인 설계를 위한 방안을 제시하고자 한다.
        4,000원
        10.
        1997.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문의 목적은 보-전단벽식 고층아파트의 단소성 지진응답해석을 수행하여 내진성능을 검토하는 것이다. 이를 위해 우선 구조물을 3차원 입체모델화하여 정적 탄소성해석을 수행하고 층 강성을 평가한 후, 그 결과를 이용하여 집중질량계모델을 사용한 시간이력 응답해석을 수행한다. 이때 탄소성 이력모델로는 modified Clough 모델을, 입력하중으로는 3종류의 기록 지진동 El-Centro 1940 NS, Taft 1952 EW, Hachinohe 1968 NS를 사용하되, 최대 지반가속도를 0.12g, 0.24g로 조절하여 사용한다. 해석모델로 장변 방향을 배치된 전단벽의 단면적이 단변의 0.5배이고, 동일한 평면을 가진 2세대가 일자형으로 배치된 25층의 아파트를 선정한다. 층간 변형각, 소성율등을 구하고 우리나라 및 미국, 일본의 내진규준에서 정하고 있는 제한사항과 비교검토한다.
        4,200원
        11.
        2018.10 서비스 종료(열람 제한)
        An experimental study was conducted to examine for the structural behavior of coupled steel plate shear wall (Coupled SPSW) system what is formed by connection the two steel plate shear walls (SPSW) with a coupling beam. The variable of this study was the length of coupling beam. The testing results were showed that the strength and stiffness of specimen with shorter coupling beam were improved than those of other specimen. However there is no difference of the yielding mechanism.
        12.
        2015.10 서비스 종료(열람 제한)
        The purpose of this study is to analyze the trend of domestic and foreign steel plate shear wall (SPSW) systems. The investigated countries were three, such as Korea, Canada, and U.S. The full scale or scale down specimens were preponderantly investigated. The details and performances of all specimens were compared for each other.
        13.
        2015.04 서비스 종료(열람 제한)
        It is possible for stress to concentrate due to interaction between shear wall and outer frame. In this study, proposed dual system installed the damper between shear wall and outer frame, and evaluated the seismic performance of the dual system through shaking table tests.
        14.
        2015.01 KCI 등재 서비스 종료(열람 제한)
        This study takes shear wall of reinforced concrete structure as study object, and the purpose of this study is to suggest structure BIM based on automatic reinforcing bar placement system applying set-based design through the most optimum reinforcing bar placement group that was selected by applying AHP (analytical hierarchy process) method from design step. For this, the most optimum reinforcing bar placement group was selected by pairwise comparison analysis on complex standard of multiple alternatives. And shear wall automatic reinforcing bar placement system has been developed, which can automatically generate members and arrange reinforcing bar by structure design algorithm and using open API (application programming interface) provided by a BIM software vendor. As a result, the most optimum reinforcing bar placement group of the highest weight, ALT1, was selected and was generated using Tekla Structure program.
        15.
        2012.05 KCI 등재 서비스 종료(열람 제한)
        복합 병렬 전단벽(Coupled shear walls)은 커플링 보와 철근콘크리트 벽체로 구성되어 바람이나 지진 등의 횡하중으로부터 유발된 전도모멘트의 상당 부분을 철골 연결보의 커플링 작용에 의하여 골조 작용(Frame action)을 의하여 횡력에 효율적으로 저항하게 된다. 본 연구에서는 접합부 상세에 따른 복합병렬 전단벽의 접합부 강도에 대한 규준식을 정립하기 위한 선행연구로서 병렬 전단벽 접합부에서 커플링 보의 매립길이 및 벽체 두께를 주변수로 실험적 연구를 수행하여 접합부 상세에 따른 복합 병렬 전단벽 시스템의 거동특성을 규명하고자 하였다. 본 실험결과, 실험체의 거동 및 내력은 매립길이 및 접합부 상세에 많은 영향을 받는 것으로 나타났으며 향후 설계시 이에 대한 영향을 반영해야 할 것으로 판단된다.