Measuring the exact cable tension force is important to cable supported bridge under construction and on service. This study was planned to propose EM(electro-magnetic) sensor-based method for measuring the tension force of MS(multi-strand) cable in cable-stayed and extradosed bridge. The tension force in each strand is the same due to MS cable construction using Iso-tensioning system. Therefore, In this prosed method, EM sensor was installed directly at a strand and the measurement model was established for estimating the tension force of strand via EM sensor by experiments. The measurement model was derived from the relation of tension force and magnetic permeability. Also, the magnetic permeability is shown to be different according to the magnetization characteristic of 1860MPa and 2200MPa high-strength strand. The difference is increased as tension force increases. Additional experiment was conducted to verify the measurement model. As a result, the distribution of strand tension calculated upon the EM sensor is similar to those of tension measured by load cell. This proposed approach can be an effective tool for monitoring and measuring the cable force of MS cable.
본 논문은 예이츠의 희곡 발야스 스트랜드에서가 어떻게 잘 알려진 아일랜드의 전설 “이퍼여왕의 외동아들”의 수백 년 간의 변형과 관련이 있는지를 연 구한다. 이 변화의 역사를 추적하면 자연적인 것과 비자연적인 것의 상충에 대한 주제 의 의미를 파악할 수 있게 된다. 예이츠는 심오한 자연의 충동에 뿌리를 둔 초자연의 모티프를 추가를 시도함으로써 본 주제를 탐색한다. 발야스 스트랜드에서는 인간성 의 거부는 초자연성의 포기와 함께 간다는 것을 보여주는 동시에 초자연성의 무시는 우리의 의미 깊은 자연적 충동의 힘을 배제할 위험이 있는 것이다.
본 논문에서는 프리텐션된 고강도 콘크리트 부재에서의 전달길이를 측정하기 위해 FBG 센서가 기입된 스마트 강연선을 활용하여 실험을 수행하였다. 전달길이 측정을 위해 길이 3m, 단면 150×150mm의 고강도 콘크리트 시험체를 총 5개 제작하였으며, 프리텐션 도입 시 콘크리트 압축강도는 58MPa로 측정되었다. 실험 결과 콘크리트 표면에 부착하는 기존의 전기 저항식 게이지보다 FBG 센서로부터 보다 정밀하고 신뢰성있는 강연선의 전달길이를 계측할 수 있는 것으로 나타났다. 계측결과로부터 산정된 강연선 전달길이를 기존의 여러 모델들과 비교하였으며, 이를 통해 고강도 콘크리트 부재에서의 전달길이 산정에 대한 기존 모델들의 적용성을 분석하였다. 본 연구 내용은 향후 강연선의 부착 특성 분석 등의 관련 분야 연구 등에 유용할 것으로 기대된다.
Recent increases in the use of Deep Deck, and the study was carried out much of the Deep Deck in the country. Research is the most studies on the behavior of the composite slab after the concrete is cured. However, the large stress is generated in the work load(150kgf/m2) at the time of pouring concrete. The Deep Deck does not satisfy the provisions of deflection during construction when applied to more than 6.0m span. In this study, installed a strand or reinforcing bar at the bottom of the Deep Deck. The pressing force of tension on the strand and rebar was carried out an experiment to produce an upward deflection of the Deep Deck. The loading experiment was carried out and the pressing force the UTM load.
예이츠의 「바일리의 바다 」는 셰익스피어의 주요 비극들을 연상시킨다. 「리어 왕」의 바보와 「맥베스」의 3마녀는 예이츠의 「바일리의 바다」의 바보와 장님과 유사한 기능을 가지고 있다. 파도와 생사가 걸린 결투를 하는 쿠후린은 고통으로 폭풍 속에서 울부짖는 리어왕을 상기시킨다. 이 논문은 첫 눈에는 잘 드러나지 않지만 예이 츠가 셰익스피어를 어떻게 차용하는지를 이해하기 위해 예이츠의 「바일리의 바다」와 셰익스피어의 「리어 왕」과「맥베스 」탐색한다.
이 연구에서는 프리스트레싱용 고강도 강연선의 정착장치 중 강연선을 직접 정착하는 앵커헤드(anchor head)에 대해 거 동특성을 분석하고, 앵커헤드의 제원을 결정하는 단계에 있어서 해석적 검토에 요구되는 프로세스에 대해 정립하였다. 앵 커헤드는 쐐기와의 접촉(contact)을 통해 강연선으로부터의 힘이 전달되고 거동변화에 따라 접촉상태 또한 변하게 된다. 이 를 고려한 상세 거동분석을 위해 쐐기와 헤드 사이의 접촉(contact)조건을 설정하였으며, 앵커헤드의 비선형 재료모델을 적 용하여 기하 및 재료 비선형성을 고려한 구조해석을 수행하였다. 해석결과로부터 다음의 결과를 얻을 수 있었다. 앵커헤드 의 거동은 앵커헤드와 쐐기 간의 상호거동에 크게 영향을 받기 때문에 초기 설계단계부터 상대 영향을 고려해야 한다. 쐐 기홀(wedge hole)의 배치는 층배열(layered) 보다는 원형배열(circular)이 보다 응력분배에 효과적이고, 쐐기홀의 간격을 증 가시키고 헤드 하면 구멍의 크기를 줄여 구멍사이 강재의 두께를 다소 늘이는 것이 구조거동에 효과적이다.
Viruses of the honeybee, Apis mellifera L. are known to reside at low levels in colonies, typically showing no apparent signs of infection. Chronic paralysis virus(CBPV) is known to induce significant losses in honey bee colonies. The pathology is characterized by clusters of trembling, flightless, crawling bees and by individual bees, sometimes hairless, standing at the hive entrance. A minusstrand-specific RT-PCR was used to assess viral replication. This is the first report on the infection of CBPV in Korea. Using (-)RT-PCR, 27 apiaries in korea were screened for the honeybee viruses, with positive colonies being analysed for viral genetic diversity. We got 550-nt PCR product from CBPV genomic RNA. Nucleotide sequences were aligned to the complete CBPV genomic RNA sequence deposited in the GenBank database and was revealed 96%(AM-CBPV) identity, respectively. Sequence comparison with other CBPV and honeybee virus.
프리스트레스트 콘크리트(PSC) 교량은 강연선 통해 도입되는 압축력을 이용하는 구조로서 강연선의 긴장력을 당초 의도대로 확보하는 것이 PSC 교량의 안전에 중요한 요소이다. PSC 교량의 긴장력은 시공 당시부터 사용 중에 이르기까지 여러 가지 요인들로 인해 감소하므로 현재 상태에서 긴장력의 크기를 정확히 파악하는 것은 대단히 중요한 일이다. 한국건설기술연구원은 강연선의 강 심선을 FBG 광섬유 센서가 내장된 카본섬유 심선으로 대체시킨 스마트 강연선을 개발하고 검증했으며, 이를 실제의 외부 텐던 교량에 적용하여 약 500일 동안 안정적으로 계측을 실시하고 있다.
The evaluation for the status and levels of tension acting on a cable supported structure has been a issue due to the structural stability. Each of strands comprising that structures is adopted prestress, the tension level of the strand during the operation is a significant factor for structural integrity of the system. However, a suitable alternative for measurement of tension acting on a strand is not proposed, as well as conservative assessment of cable system is bing adopted in industrial application. Thus, in this paper, a new method is proposed for measurement of tensile forces in a strand using guided waves. This method use a dispersion characteristic of guided waves with variation of stiffness between each of wires. Proposed method is experimentally verified by some experiments using a seven-wire strand.
The motivation of this paper is to identify the variation of stress filed in multi-strand tendon anchorage system using electromechanical impedance measurement. To achieve the objective, the following approaches are implemented. Firstly, stress variation in multi-strand anchorage system due to strand breakage is analyzed to determine the location of impedance acquisition. Secondly, a piezoelectric-based interface technique is designed to localize the damage strand. Lastly, the conceptual design of the PZT-interface is preliminarily verified by an experimental test. Impedance signatures obtained from PZT-interface are quantified by using RMSD index (root-mean-square-deviation). The result shows that the PZT-interface technique is promisingly to identify damage strands.
This study presents the investigation for relationship between local damage and structural performance of the 7-wire strand. This strand is often used additional reinforcement of bridges such as PSC (Prestressed Concrete) bridge and cable-stayed bridge. Stay cables are continuously damaged after completion and corrosion is the main cause of damage. Due to its structural characteristics, it is difficult to quantitatively evaluate the degradation cable damage. Therefore the relationship between local damages on strand and structural performance is experimentally and analytically evaluated in this study. The results can be used for the safety management of the cable supported bridges in the future.
This paper presents the assessment of 7-wire strand monitoring using acoustic emission technique for bridges. 7-wire strand is widely used construction materials to provide additional tensile force to bridges. PSC (PreStressed Concrete) bridge and cable-stayed bridge are representatives for such cases. However, as the bridge aging progresses recently, corrosion problems of strand are emerging. For this reason, various NDT (Non-Destructive Test) methods for cable inspection are being studied and applied to the field. One of the NDT methods, acoustic emission technique, is known as an effective technique to detect cable damage and breakage. In this study, to evaluate the applicability of acoustic emission technique to bridges, acoustic emission signals according to presence or absence of the strand were acquired and analyzed by tensile test. As a result, it is considered that the acoustic emission technique will be able to detect corrosion breakage and signs of rupture.
The loss of prestress in cable supported structure is a direct cause of structural deterioration of the structure. Thus, measurement and evaluation of the tensile force acted on a strand consist of the cable system have been a significant technological factor. However, a measurement method of tension for each of strands is not proposed, as well as conservative assessment of cable system is bing adopted in industrial application. This paper proposes a new and effective method for measurement of tensile force in a strand based on ultrasound. Electromagnetic acoustic transducer(EMAT) is used for generation of ultrasound. Tensile force acting on a strand can be measured by characterization of guided waves that propagate along the boundary of geometry. Consequently, proposed method is experimentally verified by some experiments using seven-wire strand.
이 연구에서는 고연성 PET 시트 및 HF(PET+aramid) 스트랜드로 보강한 RC 원형 기둥의 내진 보강 성능에 대하여 실험적으로 비 교·고찰하였다. 고연성 PET 및 HF 스트랜드로 횡 구속된 RC 원형 기둥의 내진 성능 실험결과, 모든 보강 기둥에서 최대 휨 강도 및 연성 능력 모두 무보강 기둥보다 향상되었으며 극한단계에서 섬유의 파단은 발생하지 않았다. 또한 PET 시트 25겹 보강 기둥과 HF 스트랜드 1겹 보강 기 둥의 저항 내력 및 변위가 거의 유사하여 HF 스트랜드 1겹은 PET 시트 약 25겹(동일 폭 기준)과 동일한 횡 구속 효과를 나타내었다. 결과적으로 휨 강도 증진 및 연성 능력 측면에서 PET는 RC 구조물의 내진 보강재로서 적합한 것으로 사료되나 현장적용의 가능성을 높이기 위해서는 이 연구에서 사용된 HF 스트랜드와 같이 많은 양의 섬유를 함유한 제작품과 같이 1겹으로 다수 PET 시트의 성능 효과를 내는 재료가 필요할 것으 로 사료된다. 한편 PET의 내구성에 대해서는 별도의 연구가 필요하며 현재 연구가 진행중이다.
The smart strand built-in with core wire were fabricated and submitted to test. The results showed that the application of smart strand at pier structures.
This paper presents the optimized design of Coal Silo structure using 2,400MPa PS strand and their economic benefits. Original structural design on the Coal Silo structure using 1,860MPa PS strand was reviewed in order to compare the values from the design with the optimization results.
This paper presents a protection method with FBG sensor in a 7-wire steel strand for improving measurement range of the sensor. For this purpose, both polyimide tube and teflon tube are employed to protect the FBG sensor. Uniaxial tests are carried out to compare their performances with those without the protection. The comparison showed that (1) maximum measurable deformation strain of the FBG-encapsulated strand with the polyimide tube enhancement is superior to the strand without the protection, (2) and it can measure effective strain larger than 1.00% without slip around the FBG sensor while there may occur the slip in the strand with teflon tube.
In this study, long term monitoring of tensile force of pre-tensioned prestressing strand embedded in UHPC ribbed deck by means of FBG sensor encapsulated into 7-wire prestressing strand. Based on the monitoring result for two years, it was confirmed that the technique proposed in this study offers efficient and robust way of monitoring the internal prestress of pre-tensioned PSC structures.