Machine learning is widely applied to various engineering fields. In structural engineering area, machine learning is generally used to predict structural responses of building structures. The aging deterioration of reinforced concrete structure affects its structural behavior. Therefore, the aging deterioration of R.C. structure should be consider to exactly predict seismic responses of the structure. In this study, the machine learning based seismic response prediction model was developed. To this end, four machine learning algorithms were employed and prediction performance of each algorithm was compared. A 3-story coupled shear wall structure was selected as an example structure for numerical simulation. Artificial ground motions were generated based on domestic site characteristics. Elastic modulus, damping ratio and density were changed to considering concrete degradation due to chloride penetration and carbonation, etc. Various intensity measures were used input parameters of the training database. Performance evaluation was performed using metrics like root mean square error, mean square error, mean absolute error, and coefficient of determination. The optimization of hyperparameters was achieved through k-fold cross-validation and grid search techniques. The analysis results show that neural networks and extreme gradient boosting algorithms present good prediction performance.
목구조에 있어서 횡력에 저항하는 전단벽의 역할은 대단히 중요하다. 특히 이 목조 전단벽은 다양한 수종의 스터드 와 다양한 판재, 접합철물로 제작되어 재료의 성능을 특정하기가 쉽지 않다는 어려움이 있다. 따라서, 구조설계에서 초기단계에 서부터 적용해야하는 경골목조 전단벽의 환산 전단성능값을 미국, 캐나다, 일본 그리고 국내기준의 설정방법을 통하여 파악해 보고자 하였다. 분석결과 국내 경골목구조기준과 소규모 건축기준에서 기본사양으로 제시하고 있는 2×4의 스터드에 두께 11㎜ 의 OSB를 적용한 기본 전단벽의 허용전단력은 3.5~4.5 kN/m의 범위, 또한 환산 전단강성값으로는 1100~1150 kN/m정도로 설계 하는 것이 가능할 것으로 나타났다. 특히, 국내기준은 국외기준에 비하여 상대적으로 큰 전단내력을 허용하고 있는 것으로 나타났고, 현재 기준에서와 같이 북미기 준과 동일한 전단강성을 활용할 경우, 재료의 비선형거동 때문에 실제 변형량을 과소평가할 가능성이 있어, 허용응력의 설정범 위와 전단강성값의 산정기준을 조정하여야 할 필요가 있는 것으로 파악되었다.
From measured thermal conductivity and modeling by simulation, this study suggests that U-factors are highly related to materials used between steel and polymer. The objective and prospective point of this study are to relate the relationship between the U-factor and the thermal conductivity of the materials used. For the characterization, EDX, SEM, a thermal conductive meter, and computer simulation utility are used to analyze the elemental, surface structural properties, and U-factor with a simulation of the used material between steel and polymer. This study set out to divide the curtain wall system that makes up the envelope into an aluminum frame section and entrance frame section and interpret their thermal performance with U-factors. Based on the U-factor thermal analysis results, the target curtain wall system is divided into fix and vent types. The glass is 24 mm double glazing (6 mm common glass +12 mm Argon +6 mm Low E). The same U-factor of 1.45 W/m2·K is applied. The interpretation results show that the U-factor and total U-value of the aluminum frame section are 1.449 and 2.343 W/m2·K, respectively. Meanwhile, those of the entrance frame section are 1.449 and 2.
After the manual shutdown of the Wolseong nuclear power plant due to an earthquake in Gyeongju in 2016, anxiety about the earthquake safety of nuclear power plants has become a major social issue. The shear wall structure used as a major structural element in nuclear power plants is widely used as a major structural member because of its high resistance to horizontal loads such as earthquakes. However, due to the complexity of the structure, it is challenging to predict the dynamic characteristics of the structure. In this study, a three-story shear wall structure is fabricated, and the in-structure response characteristics of the shear wall structure are evaluated through shaking table tests. The test is performed using the Gyeongju earthquake that occurred in 2016, and the response characteristics due to the domestic earthquake are evaluated.
A shear wall is a structural member designed to effectively resist in-plane lateral forces, such as strong winds and earthquakes. Due to its efficiency and stability, shear walls are often installed in residential buildings and essential facilities such as nuclear power plants. In this research, to predict the results of the shaking table test of the three-story shear wall RC structure hosted by the Korea Atomic Energy Research Institute, three types of numerical modeling techniques are proposed: Preliminary, Calibrated 1, and Calibrated 2 models, in order of improvement. For the proposed models, an earthquake of the 2016 Gyeongju, South Korea (peak ground acceleration of 0.28 g) and its amplified earthquake (peak ground acceleration of 0.50 g) are input. The response spectra of the measuring points are obtained by numerical analysis. Good agreement is observed in the comparisons between the experiment results and the simulation conducted on the finally adopted numerical model, Calibrated 2. In the process of improving the model, this paper investigates the influences of the mode shape, material properties, and boundary conditions on the structure's seismic behavior.
In Korea, the structure is mostly located on the upper part of the high embankment considering the geographical conditions at the time of expressway construction. Embankment was managed stepwise compaction according to height, but creep settlement of embankment itself may negatively affect superstructure. Reinforced earth retaining walls, which were recognized as flexible structures, were no exception to such geographical conditions. Especially, in the case of reinforced earth retaining wall located on abutment wing wall, damage due to differential settlement supported by pile, damage due to differential settlement and uneven settlement of reinforced earth retaining wall itself was frequently occurred. Therefore, in this study, the damage of reinforced earth retaining wall structure located on the high toe part was analyzed based on case. These data will be used as basic data for future maintenance.
In this study, natural period formular is presented for a RC shear wall structure with H-, T-, and L-shaped wall sections. The natural period formular proposed by Goel and Chopra and adopted in ASCE 7-10 was modified by using the ratio of the flange and web wall area. The natural periods of structures with H-shaped wall were numerically obtained, the results indicated that the ASCE 7-10 could not consider the natural period variation according to the length of the flange wall, but the proposed formula could do. Especially, ASCE 7-10 estimated much longer periods than eigenvalue analysis, and this implies that conservative seismic design is difficult. The periods by eigenvalue analysis exist between the upper and lower bounds given by the proposed formula, and conservative design is possible by using the proposed lower bound value. In order to verity the effectiveness of the proposed method, actual residential buildings with various types of flange walls are considered. Ambient vibration tests, eigenvalue analyses, and nonlinear dynamic analyses were conducted and the periods were compared with the values by ASCE 7-10 and the proposed formula. The results showed that the proposed formula could estimate more accurately the periods than ASCE 7-10.
When reinforcing an existing reinforced concrete beam-column building with a precast concrete panel, special connection between the PC member and the RC member is required to solve the time dependent deformation of the RC member and to receive the large shear forces. The aim of this study is to obtain the shear strength of upper connection between the existing RC beam-column and infilled PC wall panels in experimentally and theoretically.
Thus, the static shear loading tests were conducted on the 6 specimens with the plate connection. Shear failure was resulted from the weakest portion of interior PC panel, exterior RC, and the connection, when the PC portion which located at the center of specimen was pulled upward from the bottom. T
he experimental result was compared with analytical result from ACI 318M-14 Chapter 17 for the shear strength of post-installed anchor and PCI Handbook 7th edition 6.8 Structural Steel Corbel (PCI Design Handbook 7th edition, 2010) for the strength of cast-in H-beam. The analytical and experimental results show final failure at the same location. The failure loading of experiment showed larger than average 6% to that of the analysis.
최근에 지어진 건축물의 경우 지진에 대한 안전성을 확보하고 있지만, 내진설계 도입 이전의 건축물은 지진에 대해 매우 취약하다. 본 연구에서는 내진성능이 부족한 기존 저층 RC구조물의 지진 발생 시 안전성 확보를 위한 내진보강 방안으로 격자강판 전단벽을 제안하고 내진성능평가를 수행하였다. 횡력저항요소로 사용된 격자강판 전단벽의 탄소성 이력특성값은 실험결과를 토대로 횡력저항 기여도등을 평가하여 작성된 이선형곡선을 적용하였다. 비탄성 정적해석을 통해 대상구조물의 성능점을 찾아내어 적용 지진하중에 대한 응답과 성능수준을 평가하였다. 격자강판 전단벽을 적용한 경우, 보강 전에 비하여 응답변위가 약 42% 저감되는 것을 확인할 수 있었으며, 성능점에서 거의 탄성거동을 보여주고 있어 목표성능인 인명안전수준을 만족시켰다. 또한 반응수정계수를 산정하여 내진보강 효과를 검증하였으며, 보강 전과 후에 각각 2.17에서 3.25로 증가하여 설계기준을 초과하였다. 따라서 격자강판 전단벽에 의해 대상 구조물의 강도 및 강성보강이 적절히 수행된 것으로 판단된다.
우리나라의 석조문화재을 모델링할 때 불연속면을 갖는 구조재의 강성을 어떻게 규명하느냐가 매우 중요하지만 원형보존을 해야 하는 문화재의 특성상 이를 파악하기란 매우 곤란하다. 이를 위해 본 연구에서는 비파괴조사를 이용하여 고유진동수를 측정한 후, 시행착오법을 이용하여 측정된 고유진동수와 컴퓨터 모델링 해석을 통해 고유진동수를 비교함으로써 불연속면의 강성, 구조재의 탄성계수 등 숭례문 육축 구조를 이루는 재료의 구조적 물성을 추정하였다. 이를 통해 육축 문화재에 대한 컴퓨터 모델링 기법을 제시하고 육축구조물의 안전성에 영향을 미치는 요인을 분석하였다. 연구결과 적심석의 강성이 육축구조물의 안전성에 가장 큰 영향을 미지는 젓으로 분석되었다.
기존의 하중-기반 방법을 대체할 방법중에 성능-기반 방법이 내진설계 및 내진성능평가의 기법으로서 널리 인식되고 있는 실정이다. 탄성응답스펙트럼을 사용하는 역량스펙트럼방법은 비선형 시스템을 등가의 선형시스템으로 치환하여 주어진 지진 하중에 대한 구조물의 최대 비선형 거동을 예측한다. 본 연구의 목적은 철근콘크리트 벽체구조물에 대하여 4개의 등가단자유도방법과 5개의 등가감쇠방법을 사용하여 역량스펙트럼방법의 정확성을 평가하는 것이다. 역량스펙트럼방법의 정확성을 평가하기 위하여 벽체구조물에 대한 진동대 실험결과와 비교하였다. 또한 이선형 곡선변환방법(등가에너지 근사화방법, 유효강성 사화 방법)에 의한 이선형 역량곡선들의 역량스펙트럼 해석에 대한 영향도 비교하였다.
본 연구에서는 민감도 해석을 이용하여 전단벽-골조 구조시스템의 횡변위를 정량적으로 제어할 수 있는 강성최적설계방안을 제시하고자 한다. 이를 위해 먼저 골조와 전단벽요소 사이의 변위자유도 적합성 문제를 해결하기 위한 요소강성행렬을 구성하며, 또한 수학적계획법의 일반성을 유지하면서도 큰 규모의 문제도 효율적으로 다를 수 있는 근사화 재념을 도입하여 횡변위 구속조건식을 설정한다. 아울러 전단벽 및 골조부재의 단면특성 관계식을 설정함으로써 설계변수의 수를 줄여주고, 이를 이용하여 강성행렬도함수의 산정을 용이하게 한다. 특히 골조의 경우 초기에 주어진 단면형상이 최적설계 과정동안 계속 유지된다는 가정을 이용하여 최적설계결과에서 구해진 단면특성에 따라 부재단면크기를 산출하고, 전단벽은 사용자의 의도에 따라 두께 또는 부재길이를 재산정하는 방안을 강구한다. 이와 같이 제시된 강성최적설계기법의 효용성을 검토하기 위해 두 가지 형태의 20층 전단벽-골조 구조물의 예제가 고려된다.
The reinforced concrete wall type apartments built before 1988 in Korea, which are rarely seen in other countries, were constructed using tunnel form method for convenience of construction. Tunnel form method, however, do not arrange bearing walls in the direction of long side of the apartment, and this results in little resistance capability against lateral loads in that direction. Consequently, there exists significant collapse possibility due to the formation of plastic hinge at the joints of wall and slab during earthquake. This study experimentally investigates the reinforcement methods using carbon sheet and L-shaped steel which were not seismically designed. The reinforcement method using carbon sheet and L-shaped angle, has following advantages; construction workability, usage of light-weight material, and little requirement for the installation room. The specimen with steel bar fill up using modified epoxy mortar in the mid-span of the slab shows the same stiffness as the standard specimen without reinforcement and the stiffness of the specimen reinforced by carbon sheets without L-shaped steel was increased by only about 13%, implying that those existing methods cannot provide significant reinforcement effects. For the specimens of which wall-slab joints were reinforced using both carbon sheet and L-shaped steel, the increase of stiffness ranges from 43% to 496% and the increase of energy dissipation amount ranges from 120% to 233%. Also it was identified that the linkage method using penetration bolts was more efficient than the one using expansion anchors in increasing stiffness, strength and energy dissipation capacity.
현재 국내에서는 벽과 바닥판만으로 이루어진 벽식 구조형식의 아파트 건물이 많이 건설되고 있다. 아파트와 같은 주거구조물에서는 다양한 진동원에 의하여 진동이 발생하고 이러한 진동은 벽과 바닥판을 통하여 이웃한 세대 및 위, 아래층 세대로 전달되게 된다. 벽식구조물의 진동해석을 정확하게 수행하기 위해서는 벽과 바닥판을 많은 수의 유한요소로 세분한 모델을 사용하는 것이 필요하다. 그러나 아파트와 같은 벽식구조물 전체를 수많은 유한요소로 세분하여 모형화하면 막대한 해석시간과 컴퓨터 메모리가 필요하게 된다. 따라서 본 연구에서는 상당히 줄어든 해석시간과 컴퓨터 메모리를 사용하여 정확한 해석결과를 얻기 위하여 행렬응축기법으로 벽과 바닥판에 수직인 자유도만 가지는 효율적인 진동해석 모델을 제안한다. 벽식구조물에서 벽과 바닥에 수직인 자유도만을 남기고 나머지 자유도를 행렬응축기법을 통하여 한꺼번에 소거를 한다면 행렬응축과정에서 상당히 많은 양의 시간이 소요된다. 따라서 본 연구에서는 벽이나 바닥판에 수직인 자유도만을 가진 수퍼요소를 생성한 후 이를 조합하여 한 층을 나타내는 부분구조를 만들고 최종적으로 부분구조를 조합하여 전체 구조물을 구성하는 모형화 기법을 제안하였다. 제안된 해석기법의 정확성과 효율성을 검증하기 위하여 3층 및 5층의 벽식구조물을 예제구조물로 사용하여 동적해석을 수행하였다. 예제해석 결과 제안된 해석방법의 결과는 절점당 6개의 자유도를 모두 사용한 해석모델의 결과와 비슷한 정확성을 보이면서도 소요되는 해석시간과 컴퓨터 메모리를 대폭 줄일 수 있었다
최근 우리나라의 대도시에서는 주거와 상업기능을 동시에 갖는 복합용도의 건축물이 많이 건설되고 있는데, 이러한 건물은 대부분 하부골조에서 연층, 약층 또는 비틀림 비정형을 띠게 된다. 본 논문의 목적은 이러한 건물의 지진응답을 실험을 통해 관찰하는 것으로서 1:12 축소모델의 진동대 실험을 통해 다음과 같은 결론에 이르렀다. 1) 구조물의 불확실성으로 인한 우발비틀림을 예측하는 것은 정적해석에 의한 방법보다 동적해석에 의한 방법이 더 타당하였다. 2) 횡운동과 비틀림운동이 연관되어 있을 때, 전도모멘트는 지진방향 뿐만 아니라 지진방향에 수직인 방향으로도 상당부분 작용하였으며, 일반적인 해석프로그램에서 수행하는 모드해석법으로는 이와 같은 거동을 예측하기에 부적절하였다. 3) 모드형상과 BST 다이아그램을 통해 대상구조물과 같은 건물의 주요 진동모드와 파괴양상을 쉽게 예측할 수 있었다.
이 논문에서는 최근 사회적인 이슈로 대두된 바닥충격음 중 특히 중량충격음을 저감시키기 위한 방법의 일환으로, 바닥슬래브의 두께를 증가시키는 기존의 방식과는 달리 평판형 슬래브에 장선을 설치하여 바닥슬래브의 강성을 증가시킴으로써 고유진동수의 이동을 통한 중량충격음의 저감 효과를 기대할 수 있는 장선바닥슬래브를 제안하고, 장선의 춤과 간격에 따른 중량충격음 특성을 해석적으로 분석하였다. 해석결과, 장선슬래브의 슬래브 두께가 증가할수록 음압레벨이 감소하는 경향을 나타내었으나 일정 두께 이상에서는 큰 차이를 보이지 않아 바닥두께 증가로 인한 중량충격음 차단 기대효과에는 임계치가 있을 것으로 판단된다. 또한 장선 춤의 증가와 간격 감소에 따른 바닥강성의 증가는 일관된 중량충격음 차단성능의 증가로 이어지지 않아 최적의 중량충격음 차단성능을 기대하기 위해서는 주택의 유형별로 각기 다른 장선 춤과 간격이 적용되어야 할 것으로 판단되며, 100mm 정도 장선 춤의 증가나 간격 감소로 약 1dB~2dB정도의 중량충격음 감소효과를 얻을 수 있을 것으로 기대된다.
횡력을 받는 전단벽-골조 시스템은 휨거동을 하는 전단벽과 전단거동을 하는 골조가 슬래브의 강체평면운동(Diaphragm Action)을 통하여 상호작용하여 수평력에 효율적으로 저항하는 시스템이다. 횡력을 받는 골조의 거동은 보와 기둥의 휨 변형에 의한 골조의 수평 전단변형과 기둥의 축 변형에 의한 골조의 휨 변형으로 구분 할 수 있다. 일반적으로 전단벽-골조 시스템의 근사해석 시 골조의 휨변형은 무시하여 왔으나, 건물의 높이가 증가 할수록 골조의 휨 거동은 큰 영향을 미칠 것으로 사료된다.
따라서 본 연구에서는 횡력을 받는 전단벽-골조 시스템의 근사해석 시 기둥의 축 변형을 고려하기위하여 병렬전단벽 시스템(Coupled Shear Wall System)의 해석 시 사용하는 연속매체모델(Continuous Medium Model)을 이용하여 횡 변위 및 부재력을 산정할 수 있는 근사식을 수정 제시 하였다. 새롭게 제시된 근사식을 검토하기 위하여 기존 식과 컴퓨터에 의한 Matrix해석 결과와 비교하였으며, 비교결과 건물 높이가 높을수록 본 연구에서 제시한 근사해석 식이 기존 식보다 Matrix 해석 결과에 가깝게 나타났다.