검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 18

        1.
        2024.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        There are two primary sludge drying methods such as the direct heating microwave method and the indirect heating steam one. In this study, the drying treatment facility at sewage treatment plant A applied both of these drying methods. The research aimed to investigate the optimal operation approach for the drying facility, considering the input sludge and the moisture content data after the drying process. Moisture content and removal rate data were executed at the research facility from January 2016 to December 2018. First, the microwave, a direct heating drying method, performed intensive drying only on the outer surface of the sludge by directly applying heat to the sludge using far infrared rays, so effective sludge drying was not achieved. On the other hand, the steam method of the indirect heating method used steam from a gas boiler to maximize the utilization of the heat transfer area and reduce energy of the dryer, resulting in an effective sludge drying efficiency. The sludge moisture content brought into the sludge drying facility was about 80%, but the moisture content of the sludge that went through the drying facility was less than 10% of the design standard. Therefore, the steam method of the indirect heating method is more effective than the microwave method of the previous direct heating method and is more effective for maintenance It has proven that it is an efficient method of operating construction facilities.
        4,000원
        2.
        2022.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        자기공명영상(MRI) 장비의 조영제로 흔히 사용되는 가돌리늄(Gd)은 매우 안정된 상태로 하수처리과정에서 거의 제거되지 않고 수환경으로 유입된다고 알려져 있다. 따라서 본 연구에서는 세 가지의 공법으로 하수처리를 하는 부산 수영 하수처리장에서 채취한 하수 시료의 공정별 용존 희토류 원소의 제거율 및 수환경으로 배출되는 인위적 기원 Gd (Gdanth)의 배출량을 평가하고자 하였다. 용존 희토류 원소는 공정별 처리 단계에 따라 무거운 희토류 원소(Tb-Lu)에 비 해 가벼운 희토류 원소(La-Eu)에서 농도가 감소하는 경향을 보였다. 또한 일부 시료에서 나타난 음의(negative) Sm anomaly (<1)는 생물학적 제거 과정에서 Sm이 입자나 인산염과 흡착되어 함께 제거되었을 가능성을 시사한다. 모든 시 료에서 양의(positive) Gd anomaly (149±50, n=9)를 보였으며, 공정별로 측정된 Gd의 총 농도 중 Gdanth은 약 97% 이 상을 차지하는 것으로 나타났다. 이는 하수처리과정에서 Gdanth 이 거의 제거되지 않고 수영강 하류로 배출된다는 것을 의미한다. 일별 처리용량을 고려하여 각 공정에서 배출되는 Gdanth의 배출량은 259 mmol/day로 추정할 수 있다. 본 연 구의 결과는 하수처리장을 통해 수영만 연안으로 Gdanth이 지속적으로 배출될 것으로 예상되며, 향후 Gd의 중장기적인 관측이 필요함을 시사한다.
        4,000원
        3.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 점오염원인 하수종말처리장으로부터 배출되는 물의 수질을 분석하고 배출수의 영향을 받는 어류 중 지점들에서 공통적으로 출현하는 어종인 피라미 (Z. platypus) 를 선택하여 조직학적 변화를 참조하천 지점의 수질과 어류 조직을 비교·분석하였다. 2019년 6월 27~28일 하수종 말처리장 4곳 (대전, 전주, 청주, 익산)의 채집 결과, 참조하 천에서 22종 450개체로 가장 많은 종수 및 개체수가 확인 되었다. 지점별로 5개체씩 2~3년생 피라미의 조직표본을 제작하여 아가미와 근육조직 (피부조직)을 관찰한 결과, 참조하천을 제외한 나머지 지점의 조직은 병리적인 양상을 나타내었다. 수질분석 결과, 각 WTP에서는 배출수질 기준을 준수 혹은 더 좋은 수질로 방류하고 있었다. 그러나 하수종말처리수 배출수 및 방류수계 수질에서 오염도지표를 나타내는 항목인 BOD, COD, TP, TN, SS 값이 참조하천에 비해 높은 것으로 나타났다. 빈약한 어류상과 바이오마커로 이용된 종의 조직병리학적 상태는 참조하천에 비해 낮은 수질에서 기인한 것으로 추측되며, 따라서 원인이 되는 하수종말처리장 배출수 수질개선이 이루어져야 할 것으로 사료된다.
        4,500원
        4.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was performed to improve the foaming generated in the effluent of wastewater treatment plant from March 2015 to July 2016. The main cause of foaming was air entrainment by an impinging jet and the internal accumulation by the diffusion barrier. Particularly, the foam growth was most active when there is low tide and larger discharge. To solve this problem, we experimented after installing fine mesh screen and the artificial channel device with underwater discharging outlet in the treated wastewater discharge channel and the outlet, respectively. As a result, the effects of foam reduction by devices ranged 85.0~92.0% and 70.7~85.6%, respectively. In addition, the foam and the noise were easily solved, first of all look to contribute to the prevention of complaints. Our device studies were applied to a single wastewater treatment plant. However, it is considered to be able to apply in other similar cases of domestic sewage treatment plants.
        4,000원
        5.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to suggest the cause analysis and mitigation measures of foaming generated in the effluent of wastewater treatment plant. The foam generated in the outlet connected with the tidal river system was identified as structural problems. And the main cause of foaming was air entrainment by an impinging jet and the internal accumulation by the diffusion barrier. In consideration of these conditions, it present the effective ways such as micro-screen and submerged outlet, to mitigate the foaming generated in the water channel and outlet end.
        4,000원
        7.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study developed an up-flow wetland providing either an eco-friendly follow-up process of medium-sized public treatment facility for livestock manure or a non-point source pollution controller near livestock farms. The four bench-scale up-flow wetlands were operated with four different bed media sets. The removal efficiencies of the wetland effluent for CODCr, TN, TP, SS were 35.2 %, 29.5 %, 31.2 % and 52.2 % for set 1(Blank, without reed, with bio-ceramic), 40.6 %, 43.4 %, 42.2 % and 55.4 % for set 2(with bio-reed&without bio-ceramic), 45.2 %, 48.7 %, 46.6 % and 66.3 % for set 3(with bio-reed&bio-ceramic), 32.9 %, 27.3 %, 29.3 % and 54.1 % for Set 4(with reed&bio ceramic), respectively. The set 3 condition having a mixture of bio-reed and bio-ceramic showed the highest efficiency in the bench-scale evaluation. This study suggests a mixture of bio-reed and bio-ceramic as suitable bed media in the construction of artificial wetlands near livestock farms. Soils including the bed media were monitored during the evaluation for trace elements. Soil analysis results were satisfied with the Korean Soil Contamination Standard. This study showed that the up-flow constructed wetland was feasible to treat the effluent livestock wastewater treatment facility.
        4,300원
        9.
        2014.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Study on effluent organic matter (EfOM) characteristic and removal efficiency is required, because EfOM is important in regard to the stability of effluents reuse, quality issues of artificial recharge and water conservation of aqueous system. UV technology is widely used in wastewater treatment. Many reports have been conducted on microbial disinfection and micro pollutant reduction with UV treatment. However, the study on EfOM with UV has limited because low/medium pressure UV lamp is not sufficient to affect refractory organics. The high intensity of pulsed UV would mineralize EfOM itself as well as change the characteristics of EfOM. Chlorine demand and DBPs formation is affected on the changed amounts and properties of EfOM. The objective of this study is to investigate the effect on EfOM, chlorine residual, and chlorinated DBPs formation with low pressure and pulsed UV treatment. The removal of organic matter through low pressure UV treatment is insignificant effect. Pulsed UV treatment effectively removes/transforms EfOM. As a result, the chlorine consumption is changed and chlorine DBPs formation is decreased. However, excessive UV treatment caused problems of increasing chlorine consumption and generating unknown by-products.
        4,300원
        10.
        1993.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Anaerobic Digestion of thickened septage was investigated in this study. Thickening could reduce the volume of septage to be treated to about 40% with 12hr HRT. The VS and BOD removal efficiencies were respectively 28 to 45%, and 75% when digested the thickened septage with 30 day HRT Or $1.4kgVS/m^3/d$. The BOD removal efficiency could be increased to about 90% with subsequent settling tank with about 6 hours HRT. The gas production rate was 0.22 to $0.35m^3gas/kgVSadd$($0.75m^3gas/kgVSrm$), or $1.32m^3gas/kgBOD_{rm}$. In addition, the supernatant of thickener could be returned to the aeration tank treating domestic sewage. In this case, a BOD loading rate of 0.5 to $0.7kgBOD/m^3/d$ or 0.5kgBOD/kgMLVSS/d was proposed for 80% BOD reduction.
        4,000원
        11.
        2022.07 KCI 등재 서비스 종료(열람 제한)
        With the introduction of the tele-monitoring system (TMS) in South Korea, monitoring of the concentration of pollutants discharged from nationwide water quality TMS attachments is possible. In addition, the Ministry of Environment is implementing a smart sewage system program that combines ICT technology with wastewater treatment plants. Thus, many institutions are adopting the automatic operation technique which uses process operation factors and TMS data of sewage treatment plants. As a part of the preliminary study, a multilayer perceptron (MLP) analysis method was applied to TMS data to identify predictability degree. TMS data were designated as independent variables, and each pollutant was considered as an independent variables. To verify the validity of the prediction, root mean square error analysis was conducted. TMS data from two public sewage treatment plants in Chungnam were used. The values of RMSE in SS, T-N, and COD predictions (excluding T-P) in treatment plant A showed an error range of 10%, and in the case of treatment plant B, all items showed an error exceeding 20%. If the total amount of data used MLP analysis increases, the predictability of MLP analysis is expected to increase further.
        12.
        2018.11 KCI 등재 서비스 종료(열람 제한)
        In this study, an operational data set was analysed by establishing a path model to figure out the actual cause-effect relationship of a wastewater treatment plant (WWTP); in particular, for the effluent concentrations of T-N and T-P. To develop the path models, data sets of operational records including effluent concentrations and operational factors were obtained from a field scale WWTP of 680,000 m3 of treatment capacity. The models showed that the relationship networks with the correlation coefficients between variables for objective expressions indicated the strength of each relationship. The suggested path models were verified according to whether the analyzation results matched known theories well, but sophisticated minute theoric relationships could not be cropped out distinctly. This indicates that only a few paths with strong theoric casual relationships were represented as measured data due to the high non-linearity of the mechanism of the removal process in a biological wastewater treatment.
        14.
        2011.08 KCI 등재 서비스 종료(열람 제한)
        The covered stream of cities are considered an odor source. Also, the public do not want a wastewater treatment plant(WWTP) near their properties due to the emission of odor emanating from such sources, although they play an important role in urban development. The purpose of this study is to analyze the pattern distribution of the odorous compounds from the Nambu WWTP and Youngho stream in Busan. odor sampled four times were analyzed by instrumental analysis method and indirect olfactory method. The kinds of offensive odorous compounds examined are acetaldehyde, propion aldehyde, hydrogen sulfide, methyl mercaptan, dimethyl sulfide and ammonia. Also, Concentration of air pollutants has been calculated by ISCST3 models. At the result of this study, The Nambu WWTP releases sulfur compounds. And the major odorous were hydrogen sulfide (1,475 ppb) and acetaldehyde (95 ppb) at Youngho stream. The stink which residents feel will point out the Nambu WWTP mainly if the odor is removed with the improvement of a Youngho stream. Accordingly, we should pay more attention to appropriate components to processes in odor reducing plan at Nambu WWTP.
        15.
        2005.02 KCI 등재 서비스 종료(열람 제한)
        Statistical analysis between operating parameters and effluent quality on advanced wastewater treatment plant was performed. Through factor analysis four factors derived varimax rotation were selected each plant. Four components explained 80%, 82% of the total variance of the process, respectively. The components on MLE plant were identified in the following order:1) HRT increase and BOD load decrease by influent decrease, 2) Biomass, 3) SVI increase by internal return increase, 4) Microbial diversity by SRT increase. On A2O plant, we defined them as follows: factor 1, high MLSS by return rate increase, HRT increase by influent decrease; factor 2, biomass; factor 3, BOD of influent; factor 4 was relate to DO.
        16.
        1999.10 KCI 등재 서비스 종료(열람 제한)
        The diagnostic software for the wastewater treatment plant using activated-sluge process is developed in order to increase the efficiency of management of the wastewater treatment plant. This software is based on the expert system and the visualized user interface including the diagnosis of quantitative and qualitative data. For the generalization of this software, the initialization of each unit process and updating the files can be possible.
        17.
        1997.06 KCI 등재 서비스 종료(열람 제한)
        This study was conducted to investigate the treatment of wastewater from acetaldehyde manufacturing plant by activated sludge process with Micrococcus roseus AW-6, Micrococcus luteus AW-22, Microbacterium lacticum AW-38 and Microbacterium laevaniformans AW-41. The COD_Mn and BOD_5 of the wastewater were 5,260㎎/L and 6,452㎎/L, respectively. pH was 1.85. The main organic component in the wastewater was acetic acid which was contained 67,600㎎/L. Optimum dilution time for activated sludge process was shown 10 times. The specific substrate removal rate(K_e) was 1.95day^-1 and the nonbiodegradable matters(S_n) were 23.2㎎/L. Saturation constant (K_e) and maximum specific growth rate(q_max) were 1,640㎎/L and 2.33day^-1, respectively. Sludge yield coefficient(Y) and endogenous respiration coefficient(K_d) were 0.28㎎ MLVSS/㎎COD and 0.02day^-1, respectively. COD_cr removal efficiency was 91% for 1.95day of hydraulic retention time.
        18.
        1995.12 KCI 등재 서비스 종료(열람 제한)
        Reuse of industrial effluents through the cooling systems in a petrochemical complex was described. The partial oxidation of the effluents from the biological treatment plant was examined, using Fenton`s reagent as a pretreatment step prior to a next treatment of the effluents. Next tertiary treatment using fixed-film reactor resulted in marked reductions in COD and suspended solids. The continuous fixed-film process with Fenton oxidation pretreatment showed a 23% increase in the COD removal efficiency when compared to that without pretreatment of Fenton oxidation under the volumetric organic loading rate of 0.1 ㎏ COD/㎥/day. The Fenton oxidation treatment seemed to be a possible method for tertiary biological treatment to reduce the residual toxicity with the enhanced biodegradation of the effluents.