검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 32

        1.
        2024.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Since atypical high-rise buildings are vulnerable to gravity loads and seismic loads, various structural systems must be applied to ensure the stability of the structure. In this study, the authors selected a 60-story twisted-shaped structure among atypical high-rise structures as an analytical model to investigate its structural behavior concerning the outrigger system. The structural analyses were performed varying the number of installed layers and the arrangement of the outrigger system, as well as the placement of the mega column, as design variables. The analysis revealed that the most effective position for the outrigger was 0.455H from the top layer, consistent with previous studies. Additionally, connecting outriggers and mega columns significantly reduced the displacement response of the model. From an economic standpoint, it is deemed efficient to connect and install outriggers and mega columns at the structure's ends.
        4,000원
        2.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 해석결과를 보정하여 고층 건축물의 기둥축소 예측값과 실제값 간의 오차를 최소화하기 위한 해석보정법이 제안되었다. 이를 위하여 41층 규모의 철근 콘크리트 건물에 대한 시공단계해석이 수행되었으며, 해석결과는 기둥과 코어로 나뉘어 네 가지의 가정된 계측결과들과 비교되었다. 해석보정은 기둥에서는 오차 한계를 넘어서는 시공단계에서 코어에서는 모든 시공단계에 적용되었으며, 해석이 보정된 이후에도 지속적으로 오차가 발생하므로 해석보정이 자주 수행될수록 오차는 감소하였다. 이러한 과정을 통하여 제안된 해석보정 방법을 적용함으로써 장기적인 축소값이 실제값과 유사하게 예측될 수 있음을 확인하였다.
        4,000원
        3.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Seismic isolation systems have typically been used in the form of base seams in mid-rise and low-rise buildings. In the case of high-rise buildings, it is difficult to apply the base isolation. In this study, the seismic response was analyzed by changing the installation position of the seismic isolation device in 3D high - rise model. To do this, we used 30-story and 40-story 3D buildings as example structures. Historic earthquakes such as Mexico (1985), Northridge (1994) and Rome Frieta (1989) were applied as earthquake loads. The installation position of the isolation device was changed from floor to floor to floor. The maximum deformation of the seismic isolation system was analyzed and the maximum interlaminar strain and maximum absolute acceleration were analyzed by comparing the LB model with seismic isolation device and the Fixed model, which is the base model without seismic isolation device. If an isolation device is installed on the lower layer, it is most effective in response reduction, but since the structure may become unstable, it is effective to apply it to an effective high-level part. Therefore, engineers must consider both structural efficiency and safety when designing a mid-level isolation system for high-rise buildings.
        4,000원
        4.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The demand for skyscrapers is increasing worldwide. Until now, various lateral resistance structures have been used for lateral displacement control of high-rise buildings. An outrigger damper system has been introduced recently to improve lateral dynamic response control performance further. However, a study of outrigger damper system is yet to be sufficiently investigated. In this study, time history analysis was performed to investigate the control performance of an outrigger damper system of high-rise building under eccentric loading. To do this, an actual scale 3-dimensional tall building model with an outrigger damper system was prepared. The control performance of the outrigger damper system was evaluated by varying stiffness and damping values. On the top floor torsional angle response to the earthquake load, was greatly affected by damping value. And the displacement response was affected greatly by the stiffness value and damping value of damper system. In conclusion, it is necessary to select the proper damping and stiffness values of the outrigger damper system.
        4,000원
        5.
        2016.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Observations of the damages to high-rise reinforced concrete (RC) wall building structures caused by by recent earthquakes in Chile (Mw 8.8, February 2010) and New Zealand (February 2011, ML 6.3) have generally exceeded expectations. Firstly, this study estimated the seismic damage levels of 15-story RC box-type wall building structures using the analytical models calibrated by the results of a shaking table test on a 1:5 scale 10-story RC box-type wall building model. Then, the seismic fragility analysis of the prototype model was conducted by using the SAC/FEMA method and the incremental dynamic analysis (IDA). To compensate for the uncertainties and variability of ground motion and its impacts on the prototype model, in the SAC/FEMA method, a total of 61 ground motion records were selected from 20 earthquakes, with a magnitude ranging from 5.9 to 8.8 and an epicentral distance ranging from 5 to 105km. In the IDA, a total of 11 ground motion records were used based on the uniform hazard response spectrum representing a return period of 2,475 years. As a result, the probabilities that the limits of the serviceability, damage control, and collapse prevention would be exceeded were as follows: from the SAC/FEMA method: 79%, 0.3%, and 0%, respectively; and from the IDA: 57%, 1.7%, and 0%, respectively.
        4,000원
        6.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        High rising of the buildings offers a number of risk factors than ever before with regard to fire prevention. Especially in the construction site of high-rise buildings, people waste golden-time during the evacuation because temporary fire fighting facilities are not installed and transferred to a large fire because of fire suppression failure. In this study, the researcher derives the problems of fire protection in high-rise buildings construction sites and proposed the measures in such the legal aspects as fireᆞ building construction code and etc. There are the legal improvements such as orders of construction suspension in the problems of fire safety, appointing fire safety manager, temporary fire protection installation standards, enhancing penalty provisions regarding the use of fire, operating self fire brigade, confirming on-site after completing fire-protection facalities, establishment or strengthening special fire-protection investigations
        4,300원
        7.
        2015.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        근래 국내 초고층 주상복합 건물에는 철근콘크리트구조가 보편적으로 적용되는데, 이러한 철근콘크리트 초고층 주상복합 건물은 시공 시점에 따라 구조적인 문제가 발생할 수 있다. 따라서, 시공 중인 철근콘크리트 초고층 주상복합 건물에 대하여, 시공 시점별 구조 안전성 및 횡력저항성능을 검토하고자 한다. 이를 위해, 예제 모델로 탑상형의 초고층 주상복합 60층 건물을 선정했고, 기존의 범용구조해석 프로그램을 사용하여 구조해석을 수행하였다. 각 시공 시점별 10층, 20층, 30층, 40층, 50층, 60층 완료모델과 60층 완공단계 모델의 구조성능을 비교하였다. 구조성능 비교를 위해 이 모델들의 고유치해석을 수행하였으며, 횡력저항성능과 부재별 단면성능을 검토하였다. 횡력저항성능 검토를 위해 횡변위비와 층간변위비를 검토했고, 부재별 단면성능 검토는 완공단계에 대한 설계강도비와 시공단계의 설계강도비를 비교하여 부재안전성을 검토하였다. 이 연구를 통해, 시공 중인 철근콘크리트 초고층 건물의 구조 안전성을 검토하고 시공단계에 적합한 구조해석 및 설계하중의 가이드라인을 제시하고자 한다.
        4,000원
        8.
        2012.11 구독 인증기관 무료, 개인회원 유료
        Recently buildings are constructed in larger and higher scales and becoming more complex. Every country in the world is competing to build high-rise buildings. Korea also has and is constructing high-rise buildings, like the 123story Jamsil Lotte Super Tower. However from small to large scale buildings and on construction sites there still are fire safety accidents that occur continuously. Therefore to improve fire safety plan, examining the actual fire safety management and understanding fire risk analysis Using Fire Modeling through Computer Simulation. Fire safety management plan related fire safety cases were collected an dan analyzed for the study. Also hazard analysis of High rise Buildings under fire compared with existing fire law sand regulations.
        4,000원
        9.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 테러의 발생빈도가 증가하는 가운데 테러는 불특정 다수의 사람이 모이는 건물에서 집중적으로 발생하고 있다. 이중 고층, 초고층 빌딩에서 발생하는 테러는 막대한 피해를 발생시킨다. 이에 따른 건물의 테러피해 경감을 위한 다양한 연구가 필요하다. 본 논문에서는 비교적 수행절차가 간단하며 단기간에 실행이 가능한 Fema 455 - Rapid Visual Screening을 통해 현재 사용 중인 국내 고층 초고층 건물의 테러에 대한 위험도를 평가하여 국내 건물이 가지는 공통적인 테러 위험요소를 확인하였다. 평가결과 대상 건물은 모두 중위험도의 범위에 있다. 이는 국내 고층, 초고층 건물의 외부 환경적인 특징이 비슷한 데에 그 원인이 있었다.
        4,000원
        10.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 초고층 건축물 외부공간의 식물 피복 상태가 온도변화에 미치는 영향을 파악하고자 서울시에 위치한 초고층 건축물 12개소를 대상으로 연구를 수행하였다. 초고층 건축물 외부공간의 토지 피복 유형별 온도 차이 분석을 위해 6개 유형(외곽도로, 포장지, 관목/초지, 단층교목식재지, 다층식재지, 수경시설)으로 건축물외부공간의 피복유형을 구분하였으며 토지이용유형별 대표지점에서 온도를 실측하였다. 건축물 12개소의 주변 환경차이를 고려하기 위해 외곽도로의 중앙부에 대조구를 선정하여 온도를 측정한 후 일원배치 분산분석을 토대로 유사한 온도경향을 보이는 대상지를 4개 그룹으로 분류하였다. 분류된 그룹의 토지 피복 유형과 외부 공간 온도와의 일원배치 분산분석결과, 주로 단층교목식재지, 수경시설, 다층식재지는 저온역에 속하였으며, 관목/초지, 포장지, 외곽도로는 고온역에 속하였다. 저온역과 고온역의 온도차이는 약 1.06~6.17℃의 차이를 보였다. 그러나 조성된 식재지와 수경시설 면적의 협소, 건축물로 인한 일사도달량의 저감과 반사량의 증가 등으로 초고층 건축물 외부공간 온도에 미치는 영향이 다양하게 나타났다. 이에 각 공간에 필요한 녹지량과 수공간의 면적을 조성 전 미리 산출하여, 효과를 발휘할 수 있는 최소한의 면적과 녹지량을 확보할 필요성이 있었다.
        4,300원
        11.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 풍하중을 받는 고층 구조물의 진동저감을 위하여 사용되어온 전단형 점탄성 감쇠기의 2D, 3D FEM 모델을 이용하여 정밀하게 해석하여 점탄성재료와 이들을 결합하는데 사용하는 재료의 특성이 에너지 소산에 미치는 영향을 평가하였다. 특히 점탄성재료와 강재의 접합방식 및 크기, 형상등이 에너지 소산능력에 미치는 영향을 분석하였다. 이러한 정밀해석과정을 통하여 점탄성 감쇠기의 이력거동을 고찰 분석하고 이를 댐퍼설계에 활용하기위한 설계식을 제안하는 기초자료로 사용할 수 있게 하였다.
        4,000원
        12.
        2008.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        건물 주변의 빌딩바람을 예측하고자 강한 3차원 난류장에서 PIV시스템을 사용하여 건물을 모양별, 높이별로 분류하여 약 20가지의 풍동실험을 실시하였다. 형상별 실험에서는 정사각형, 직사각형, 원형 건물과 정사각형에서 4모서리를 따낸 모서리 절삭 사각형 건물을 풍향 0o와 45o로 하여 각각 풍속을 측정하였고, 높이별 실험에서는 정사각형, 직사각형, 원형 건물을 Full Scale 높이 150m, 90m, 60m, 30m로 달리하여 각각 풍향 0o, 45o로 측정하였다. 이 PIV 실험결과를 CFD시뮬레이션 결과와 비교하여 초고층 건물 주변의 강한 3차원 난류장 기류해석에 PIV시스템에 의 한 풍속 측정이 가능한지에 대해 그 유효성을 검토하였다.
        4,000원
        13.
        2008.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Taft N21E 지진파를 사용하여 1:12 축소된 모델로 여러번의 진동대 실험을 저층부 2개층에 비틀림과 연층을 가지는 17층 고층 철근콘크리트 건물에 대해 지진 거동을 조사하기 위해 수행했었다. 이 거동의 주요 특징은 (1) 연약 골조가 거대한 비탄성 변형을 받은 후 변형이나 비틀림에서 비틀림 모드까지 현저한 진동의 갑작스런 변화, (2) 이러한 모드 변화에 따른 비틀림 강성의 갑작스런 증가, (3) 비틀림 모드에서 월의 요곡(warping) 거동, 그리고 (4) 진동대 거동의 반대 방향에만 생기는 전도모멘트 양상을 보여주었다. 본 연구에서는 이러한 성과를 Perform3D라는 비선형 해석 프로그램을 사용하여 위 특성을 모사하기 위해 노력하였다. 이 소프트웨어에서 가용한 비선형 모델과 함께 그의 장점과 단점을 해석 및 실험 결과의 비교를 통해 제시하였다.
        4,000원
        14.
        2008.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 최상층면진시스템을 적용한 고층건물의 진동제어 가능성을 검토하여 보았다. 이를 위하여 20층 및 50층 건물을 예제구조물로 선택하였고 El Centro 남북방향 성분을 지진하중으로 사용하여 수치해석을 수행하였다. 그리고 인공풍하중을 사용하여 풍하중에 대한 예제구조물의 사용성을 검토하였다. 면진되는 상부층의 수를 변화시켜가면서 구조물의 응답을 평가함으로써 최적의 면진질량에 대해서 검토하였다. 또한 상부층면진시스템의 고유진동주기 변화에 따른 진동제어성능의 변화를 고정기초구조물과 비교하여 검토하였다. 해석결과 최상층면진시스템은 동조질량감쇠기로서 활용될 수 있으며 풍하중 및 지진하중에 대한 고층건물의 동적응답을 효과적으로 저감시킬 수 있었다.
        4,000원
        15.
        2007.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        철골조 고층건물을 대상으로 풍응답계측을 실시하여, 감쇠율과 고유진동수의 진폭의존성을 검토하였다. 진폭의존성의 검토를 위하여 RD법을 사용하였다. RD법에 의한 진동특성을 하프파워법에 의한 진동특성과 비교하여 두 방법 사이의 상관관계를 분석하였다. 또한 일본, 캐나다기준에 의한 강풍시의 사용성평가를 통하여 두 가지 방법의 적용성을 검토하였다. RD법에 의하여 감쇠율의 진폭의존성을 확인하였으며, 고유진동수의 진폭의존성은 공학적인 의미에서 상대적으로 매우 작은 것을 확인하였다. 또한 계측건물은 사용성을 만족하였으며, 일본기준이 캐나다기준보다 더욱 엄격함을 확인하였다.
        4,000원
        16.
        2007.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 초고층 주상복합건물의 품질관리를 통한 시공 분야의 효율성의 특성을 파악하는데 있다. 기존연구에서 시공관련 품질개선요소들이 정리되었으며 규격화된 설문서를 통하여 시공 분야에 있어서 개선요소를 대학원생을 포함한 건축 관련 대학교, 건설회사, 설계사무소등의 실무자들의 의견을 조합하였다. 설문조사 결과와 기존현장 기술자들의 품질관리 인식도를 비교하여 현장별 품질관리의 정량적, 정성적 성과척도를 파악하고 분석하였다.
        4,000원
        17.
        2007.03 구독 인증기관 무료, 개인회원 유료
        The control performance of LCVA designed for mitigation of wind-induced motion of Songdo high rise building is evaluated using 1/20 scaled test model. The effectiveness of the LCVA is then examined tuning LCVA to 90%, 100%, and 110% of the natural frequency, 0.74Hz. The test structure is excited using a sinusoidal signal ranging 0.2 ~ 1.2 Hz with 5.5mm displacement, and acceleration and displacement of structure, water height, and shear force are measured. Experimental results indicate that the LCVA tuned to 100% of the natural frequency with orifice opening ratio of zero reduce the peak and RMS displacement up to 67% and 72%.
        4,000원
        19.
        2005.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Frank Lloyd Wright and Mies van der Rohe are two of the most influential architects in modern architecture. In spite of the different values in their architectural lives, the design of high-rise building had been a continuous matter of primary concern for them. The purpose of this study is to compare the architectural characteristics of the two master architects in terms of building form, structure, function, and envelop skin. glass. Both of them shared with the principle of organic architecture even in the design of high-rise buildings. However, the specific approaches to realize it in high-rise buildings are significantly different. Although they emphasized the integration of building form and structure, Wright regarded the reinforced concrete structure as an organic form-giver, while Mies introduced the steel skeleton structure only as an efficient and flexible building frame. As primary finishing materials for high-rise buildings, glass was used for functional purpose by Wright, but for visual purpose by Mies.
        4,600원
        1 2