검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 4,678

        3888.
        2009.05 KCI 등재 서비스 종료(열람 제한)
        Aircraft Measurements of gaseous pollutants(SO2, NOx and O3) in the Yellow Sea area, were carried out on 1997-2007. Main measurement site in 124°-127°E, 35°-37°N (in the Yellow Sea), have been done along the paths classified vertically and zonally. To understand how the air stream affects Long-range transboundary pollutants in Northease Asia (LTP), the tracks of pollutants in northeast Asia have been analyzed by dividing into 6 different regions(regions I-V and L). Compared with Korea's local sources and western north Pacific influenced by the Yellow Sea, when the air stream from region Ⅱ is dominant, the SO2 concentrations are 3-6times higher. In region Ⅱ and Ⅲ, SO2 concentrations are represented highest at 25.0 and 14.7 ppb, respectively. However, in other regions, SO2 concentration was recorderd the highest at 1.1-3.8 ppb, which is 7-15% higher then the highest one over the region Ⅱ and Ⅲ. During 1997-2007, the mean amount of incoming pollutants is 0.162 ton/km·hr exceeding about 5-times mean amount of outgoing pollutants over the West Sea. During the observed period, the amount of incoming and outgoing SO2 over the Yellow Sea is the highest in winter, at 0.224 ton/(km·hr) and 0.120 ton/(km·hr), respectively.
        3889.
        2009.05 KCI 등재 서비스 종료(열람 제한)
        In this study, the characteristics of granular activated carbon (GAC) supported metal was investigated in an area influenced by flame discharge and temperature variation during irradiating microwave. The modified GAC was formulated by impregnating metal hydroxides of nickel (Ni/GAC), barium (Ba/GAC), copper (Cu/GAC), zinc (Zn/GAC), cobalt (Co/GAC) and lanthanum (La/GAC). Ba/GAC was selected as it showed lack of spark discharge and temperature increasing aspects. Comparison of adsorption and desorption amount of GAC and Ba/GAC showed that adsorption and desorption rate of the GAC were higher than those of Ba/GAC. The results show that the presence of barium can decrease adsorption/desorption rate because of plugging pore of GAC. Toluene regeneration rate of Ba/GAC was better than that of GAC due to barium loading. Finally, GAC with barium can be controled a rapid increasing temperature and spark discharge, increased the regeneration rate of toluene during desorption by irradiating microwave.
        3890.
        2009.05 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 대청댐 하류 금강을 대상으로 댐건설에 따른 유황 변동이 어류서식처 환경에 미치는 영향을 정량적으로 분석하였다. 분석에는 RAP을 이용하였고, 대표어종으로는 쉬리, 참마자, 감돌고기를 선정하였다. 분석 결과에 따르면 유량이 감소하는 갈수기에 대청댐의 건설과 더불어 서식처 조건이 향상 하였으나, 용담댐 건설의 영향은 미미한 것으로 나타났다. 이와 같은 결과는 댐건설에 따른 갈수기의 방류량 증가가 본 연구에서 선정한 대표어종들이 선호하는 서식처
        3892.
        2009.05 KCI 등재 서비스 종료(열람 제한)
        본 연구는 기존의 CFT구조, 아치구조, 프리스트레스구조를 조합을 통해 복합구조를 이루는 CFTA거더를 소개하고, 25m의 CFTA거더의 실험결과와 유한요소해석 프로그램인 Strand7을 이용하여 해석결과를 비교 분석하였다. 실험체의 정적재하실험으로 거더 중심부에서 양쪽으로 1m 이격한 거리에 58kN, 88kN, 148kN, 207kN, 298kN의 하중을 재하 하고, 발생하는 변위와 변형률을 측정하였다. 또한, 실험결과를 바탕으로 구조해석 프로그램인 Strand7로 구조안정성을 검토하고, 긴장재의 긴장력과 콘크리트의 탄성계수를 각각 20%증감하여 해석을 수행 하여 변형률과 변위값을 계산하였다. 초기 변위와 변형률은 긴장재의 긴장력의 증감에 따라 영향이 나타났으며, 추가적인 정적 하중이 재하 되었을 경우에는 콘크리트의 탄성계수만이 변위와 변형률에 영향을 미치는 것으로 확인 되었다.