        검색결과 275

        141.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        Concrete structures built by 3D printing technology is formed as the several concrete layers. Thus, 3D printing technology for concrete structure could have less strength than the design. In this study, fracture energy (fracture toughness) tests for layered concrete in various condition was performed. depending on required time for stacking new layer. Based on the results of performed tests, it was found that fracture energy was decreased due to increased non-bonded time.
        142.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        In the case of marine concrete composite structures, damaged by the various environment effect(sea damage, freeze-thaw, carbonation), and then, there is a possibility of going bad in the safety. The purpose of this study is to perform periodic measurements and tests on the durability test site constructed at sea and to provide basic guidelines for future maintenance based on the analyzed data.
        143.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        reinforced concrete structures, carbonation phenomena associated with deterioration is important. So, this study conducted a visual inspection and a concrete durability test in Precise Safety Diagnosis, analyzed the result, and tried to suggest a reasonable repair method and range of concrete carbonation.
        144.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        When reinforcing an existing reinforced concrete beam-column building with a precast concrete panel, special connection between the PC member and the RC member is required to solve the time dependent deformation of the RC member and to receive the large shear forces. The aim of this study is to obtain the shear strength of upper connection between the existing RC beam-column and infilled PC wall panels in experimentally and theoretically. Thus, the static shear loading tests were conducted on the 6 specimens with the plate connection. Shear failure was resulted from the weakest portion of interior PC panel, exterior RC, and the connection, when the PC portion which located at the center of specimen was pulled upward from the bottom. The experimental result was compared with analytical result from ACI 318M-14 Chapter 17 for the shear strength of post-installed anchor and PCI Handbook 7th edition 6.8 Structural Steel Corbel (PCI Design Handbook 7th edition, 2010) for the strength of cast-in H-beam. The analytical and experimental results show final failure at the same location. The failure loading of experiment showed larger than average 6% to that of the analysis.
        146.
        2016.10 서비스 종료(열람 제한)
        Recently, the concern on the deterioration of concrete due to de-icing salts and its counter measurements has been increased. This paper discusses the durability Assessment procedure of RC Structures against chloride attack under depicing salt environments.
        148.
        2016.10 서비스 종료(열람 제한)
        Recycled aggregate is not used the structures due to the negative perception of the quality. Using only recycled aggregate concrete structures to improve these recognition were constructed to evaluate the mechanical properties and durability. The result is determined to be applicable to 100% recycled aggregate concrete in the structure.
        149.
        2016.04 서비스 종료(열람 제한)
        A new array was suggested for effective leakage detection of concrete water facility. This array was modified to serve the purpose. Plus and minus currents have been installed respectively on the upstream and downstream water in order to detect the flow of water floating through the crack of facility. Potential poles in two lines have been installed closer than current sources to the weir to measure potential difference in upstream and downstream. Interpreting the potential difference data acquired by the new array, we could predict that where is the leakage zone. The possibility that can distinguish the leakage zone has been confirmed by numerical and physical modeling and problem position expected to leak was verified in field exploration.
        150.
        2016.04 서비스 종료(열람 제한)
        In reinforced concrete (RC) structures, concrete carbonation depth is an important criterion for the deterioration of durability of RC structures. Concrete carbonation is influenced by multiple factors such as chloride attack, crack, concrete compressive strength, etc. However, due to its complex mechanism, most previous studies considered only one or two deterioration factors to estimate the concrete carbonation depth. In this study, therefore, inspection data were collected from 8 buildings, and the Adaptive Neuro-Fuzzy Inference System (ANFIS) algorithm that estimates the concrete carbonation depth of RC structures has been proposed. The proposed ANFIS model provided good estimations on the carbonation depths.
        151.
        2016.04 서비스 종료(열람 제한)
        When substation structures are designed, it is important to investigate the design, construction and maintenance plans to enhance the endurance for chloride environment, freezing and electrochemical attack. The research is conducted to investigate intended service life of reinforced concrete substation structures.
        152.
        2016.04 서비스 종료(열람 제한)
        The purpose of this study is to estimate structural integrity evaluation of the concrete pontoon structure when the boundary condition and time changes. The structural integrity evaluation is conducted through the system identification method using dynamic properties. Dynamic properties are extracted with the structures when it is located on the ground and submerged in the sea. The variation of the structural stiffness due to a certain period time is discussed.
        154.
        2016.01 KCI 등재 서비스 종료(열람 제한)
        이 연구의 목적은 개착식 전력구 콘크리트에 발생하는 부등건조수축에 의한 균열특성을 파악하고, 그 제어방법을 제시하는데 있 다. 건조수축균열은 콘크리트 내부의 수분확산계수의 영향을 크게 받으며, 수분확산계수는 콘크리트 내부에서의 수분이동속도를 결정하는 주요인자이다. 수분확산계수와 더불어 콘크리트 표면의 표면계수와 외부의 상대습도는 콘크리트 내부에서 외부로의 수분이동에 영향을 미친 다. 따라서 이 연구에서는 전력구 박스형 콘크리트 구조물의 부등건조수축에 의한 균열특성을 파악하기 위하여 세 가지 주요영향인자를 고려 한 수치해석을 수행하였다. 수치해석 결과, 수분확산계수와 표면계수가 증가할수록 상부슬래브의 부등건조수축에 의한 균열발생시점이 빨라 지며, 세 가지 요인 중에 콘크리트의 부등건조수축에 의한 균열발생 특성에 가장 큰 영향을 미치는 것은 외기습도인 것으로 나타났다. 이 연구 결과를 분석한 결과, 개착식 전력구 시공시에 콘크리트 타설 후 표면보습이나 살수양생과 같이 외기습도를 증가시키는 것이 부등건조수축에 의한 균열제어에 가장 효과적인 것으로 판단되며, 콘크리트 재료적 측면의 균열저감방법으로 수분확산계수와 표면계수를 결정하는 콘크리트 의 배합이나 재료특성을 적절히 선정함으로써 균열의 진전속도나 발생시점을 제어할 수 있을 것으로 판단된다.
        155.
        2015.11 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 유황을 폴리머화하여 콘크리트 표면보호재로 활용가능성을 검토하기 위하여 내구성능 및 생물독성 평가를 실시하 였다. 평가 결과, 콘크리트 표면보호재의 내화학성능은 산, 알칼리 용액에 대하여 화학저항성이 우수한 것으로 나타났다. 배합조건별 촉진내후 성 실험 후 부착강도평가 결과 규사분말 및 플라이애시를 동시에 혼합한 배합에서 가장 우수한 강도특성을 나타내었다. 콘크리트용 표면보호 재 시험체의 온냉반복 후에도 모든 배합조건에서 부착강도 1 MPa을 상회하였고, SFS배합에서 가장 높은 부착강도를 나타내었다. 표면보호재 를 도포한 콘크리트의 촉진탄산화 및 염소이온침투저항성을 검토한 결과, 규사분말을 채움재로 사용한 표면보호재를 도포한 시험체에서 가장 우수한 내구성능을 나타내었다. 유황폴리머를 콘크리트 표면보호재로 사용시 생물독성 검토를 위해 어독성 실험을 수행한 결과, 유황폴리머 는 생물에 미치는 영향은 없는 것으로 나타났다. 표면보호재의 내화학성, 동결융해저항성, 탄산화, 염소이온침투저항성 등을 모두 고려하여 볼 때, 본 연구범위에서는 유황폴리머에 채움재로서 규사분말과 플라이애시를 각각 20%씩 대체하는 것이 적절한 수준인 것으로 판단된다.
        156.
        2015.11 KCI 등재 서비스 종료(열람 제한)
        이 연구의 목표는 학교 건물과 같은 저층 보-기둥 철근콘크리트 구조 건물에서 프리캐스트 벽패널을 사용한 새로운 내진보강 방법 을 개발하는데 있다. 1개의 무 보강 보-기둥 실험체와 U형 PC 패널로 보강한 2개의 보강 보-기둥 실험체에 대한 정적 이력 하중실험을 진행하 였다. 앵커 접합부 실험체는 전단 파괴될 것으로 해석되었고 철판 용접 접합부 실험체는 휨 파괴할 것으로 예측되었다. 실험체의 종국 내력은 상부 접합부의 전단 내력과 PC 패널 절곡 부 휨 위험단면에서 휨 내력 중 약한 것으로 결정되었다. 이 실험체에서, 한쪽 RC기둥이 가 하중(미는 실험 하중)을 받아 PC 패널 부재를 밀게 된다면, 다른 쪽 내부 수직부재는 상부 전단 접합부로부터 부 하중(당기는 실험 하중)을 받게 되어있었 다. 가 하중을 받는 2개의 부재는 합성 휨 거동이 지배적이므로 합성단면의 휨 내력이 실험체의 최종 내력을 결정하게 되지만, 이 경우 최종 내 력에 대하여 상부 전단 접합부 강도의 직접적인 영향은 없다고 볼 수 있다. 그러나 부 하중(당기는 하중)을 받는 RC 기둥과 PC 패널 부재는 비 합성 거동이 지배적이고 실험체의 최종 내력은 상부 전단 접합부 전단내력의 크기에서 직접 영향을 받는 것으로 파악되었다. ACI 318M-11 Appendix-D 앵커 전단설계에 기초한 전단내력 그리고 실험에서 얻은 최대하중을 적용하여 마이다스 젠 탄성설계에 의하여 계산한 전단 외력 에 대한 비교 해석결과는 실험결과와 일치하는 해석결과를 보여주었다.
        157.
        2015.10 서비스 종료(열람 제한)
        In the current concrete structure of the highway is still the major problem most of concrete deterioration caused by the freeze-thaw and de-icing salt, which is of issues that are not completely resolved. In particular, a single freezing event does not cause much harm, durability of concrete under multi-deterioration environment by repeated freeze-thaw and de-icing salt is rapidly degraded and reduce its service life. In this study, to considering environmental characteristics when design and construction of concrete structures, the exposure environmental guidelines were established by investigation the application rates of de-icing salt, temperatures and snowfall characteristics during five years (2004∼2008) by regions. Also, damage condition and chloride content of the structural at regions of moderate and severe environmental exposures were investigated.
        159.
        2015.10 서비스 종료(열람 제한)
        Traditional methods for concrete structure demolition is not adequate specially for urban areas and historical places due to hazard of explosive and noise. Therefore, Soundless Chemical Demolition Agents (SCDA) is useful in urban area and historical places. In this study, a analysis for SCDA is performed depending on boundary conditions.
        160.
        2015.10 서비스 종료(열람 제한)
        A new approach to evaluate the durability of concrete structures was proposed in this study, which additionally considered the time-dependent and environmental effects, especially freezing-thawing and salt attack. This might have a potential for the reasonable durability evaluation with the systematic management of SOC facilities.