검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 1,090

        181.
        2021.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The railroad facilities are intended for long-term operation as the initial acquisition costs necessary for infrastructure construction are high. Therefore, regular maintenance of railroad facilities is essential, and furthermore, system reliability through systematic performance evaluation is required. In this study, the signal control system of railroad electrical equipment was selected as the subject of research and the performance evaluation target facility selection study was conducted using AHP. The results of the study can contribute to the reliability of the signal control system as well as to the reliability of the railroad system, which is a higher system.
        4,000원
        182.
        2021.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 국내 지진 발생 빈도 및 강도가 증가함에 따라 지진 발생시 건물 주요 구조부에 대해서는 내진설계 및 내진 구조기술이 적용되어 지진에 대비하고 있으나, 비구조 요소인 커튼월과 창호에 대해서는 내진에 대비한 충분한 고려가 이루어지지 못하고 있다. 본 연구에서는 동적 내진성능 기준을 만족할 수 있는 커튼월을 개발하기 위해 동적 지진파 인가 시 커튼월이 파손 없이 대응 가능한 지진 변위 대응 패스너를 적용하여 동적 내진성능실험을 통해 이를 규명하고자 한다. 동적 내진성능실험을 수행한 결과, 본 연구에서 제시한 3축 이동형 패스너를 활용한 커튼월이 실제 지진파에 대응 가능하다는 것을 확인할 수 있었다.
        4,000원
        183.
        2021.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문은 증기이송튜브를 이용한 현장경화 보강튜브 삽입공법(Cured in placed pipe, CIPP)의 성능을 평가하기 위한 실험적 연구이다. 연구를 위해 증기이송튜브를 이용하여 CIPP 라이너 시편 및 CIPP 라이너로 보수된 콘크리트관 실험체를 제작 하였다. CIPP 라이너 시편을 이용하여 단ㆍ장기 휨특성을 평가하였으며, 단기 휨특성 시험변수로 시점으로부터 떨어진 거리를 고려하였다. 단기 휨거동 평가결과 CIPP 라이너의 휨강도 및 휨탄성계수는 ASTM 기준에서 제시하고 있는 휨강도 및 휨탄성계수의 197%, 154% 수준으로 우수한 단기 구조 성능을 보이는 것으로 나타났다. 또한 시점부로부터 떨어진 거리와 CIPP 라이너의 단기 휨특성은 큰 상관관계가 없는 것으로 나타났다. 장기 휨거동 시험내용을 이용하여 1차원 회귀분석을 실시한 결과 50년 경과 후 CIPP 라이너의 휨 탄성계수는 초기 휨탄성계수의 87.8%로 우수한 장기 구조 성능이 나타났다. 이 후 CIPP 라이너로 보수된 콘크리트관 실험체의 외압강도시험을 실시하였다. 외압강도시험 변수로 보수 유ㆍ무 및 시점으로부터 떨어진 거리를 고려 하였다. CIPP 라이너로 보수된 콘크리트관의 외압강도는 보수되지 않은 콘크리트관에 비해 초기균열 하중은 16.8%, 최대하중은 7.7% 증가한 것으로 나타났다. 외압강도 시험결과 시점으로부터 떨어진 거리와 외압강도는 상관관계가 없는 것으로 나타났다. 이는 실험체 제작시 증기이송튜브를 이용하여 CIPP 내부 모든 구간에서 균일한 경화온도를 확보할 수 있었기 때문으로 판단된다.
        4,000원
        184.
        2021.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구는 GFRP관을 상수도관으로 사용하기 위해 테스트베드를 설치하여 지중매설된 관의 구조적 거동에 미치는 영향을 조사하였다. 또한, GFRP관의 역학적 성질을 조사하고 관 강성을 추정하였다. KS규격에서 제시하고 있는 허용드로우와 고압력(사용압력의 1.5∼2.0배), 트럭하중을 적용시켜 관 내부와 외부의 복합하중이 작용할 경우 관 내압의 변화와 관의 거동을 확인하였다. 그 결과, 상수관으로 GFRP관을 장기 사용하여도 충분한 내압을 가지고 있음을 확인하였다.
        4,000원
        185.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The 37 indicators for performance evaluation of public sewage management agencies are divided into four major categories (agency manpower management ability, wastewater treatment plant operation and management, sludge and water reuse, service quality) in the first stage, and the necessity and score acquisition for the detailed indicators by each major category in the second stages. Priority was investigated through the Analytic Hierarchy Process (AHP) analysis technique for ease and relevance of company efforts. Also, based on the results of this analysis, integrated type weighting and relative importance were analyzed. As a result of the analysis, the weight and relative importance of the first stage classification were in the order of wastewater treatment plant operation and maintenance, operation agency manpower management ability, sludge and water reuse, and service quality. As a result of analyzing the weights and priorities of the detailed performance indicators in the second stage, it was found that operator’s career years, the percentage of certification holding rate in operators, compliance with the effluent water quality standards, training times for operators, and efforts to manage hazardous chemicals were important. Some of the indicators of operation agency performance evaluation may include indicators in which the performance of the company's efforts is underestimated or overestimated. In order to improve this, it is necessary to give weights in consideration of the necessity of the indicator, the relevance of the company's efforts, and the ease of obtaining scores.
        4,000원
        186.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 CH4/CO2 혼합가스에서 CO2 분리를 위해 세라믹 중공사 접촉막 모듈(HFMC)을 이용하여 실험을 수행하였다. 고 내구성의 HFMC를 제작하기 위해, 고강도의 중공사막을 제조하여 평가하였다. 제조한 중공사막을 이용하여 HFMC를 제작하였고, 실험은 CH4/CO2 혼합 기체(30% CO2, CH4 balance)와 monoethanolamine (MEA)를 사용하였다. HFMC 운전 중 기체와 흡수제의 압력이 CO2 제거 효율에 어떠한 영향을 주는지 평가하였다. CO2 제거 효율은 기체압력이 증가함에 따라 같이 상승하였으며, CO2 흡수 flux 또한 액체유량과 함께 증가하는 추세를 보였다. 또한 CO2 흡수율이 40% 이하일 때 는 흡수제가 아래쪽에서 들어가는 향류형태인 LTS-1이 흡수제가 위쪽에서 들어가는 향류형태인 LTS-2보다 CO2 제거 성능 이 높았으며, 흡수율이 40% 이상일 때는 LTS-2가 LTS-1보다 성능이 높았다.
        4,000원
        187.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        1. 본 연구의 목적은 한국 공여기관이 수행한 ODA 사업을 대상으로 수원국 주민에 의한 정량적 평가방법이 사후평가에 적용가능한지를 탐구함. 2. PLS-SEM 모형을 통해 OECD/DAC 5대 기준별 점수를 산출하였으며 추가로 ODA 성과가 주민 만족도와 공여국 이미지에 미치는 영향관계를 분석함. 3. 주민은 OECD/DAC 5대 기준 중 영향력에 대해 가장 낮은 점수를 부여하였으며 ODA 성과가 높을수록 주민 만족도와 공여국 이미지는 높아지는 것으로 나타남. 4. 본 연구를 통해 ODA 사업 사후평가에 주민참여형 정량적 평가의 적용가능성을 확인하였으며 본 평가방법은 공여국 전문가 주도의 평가방식을 보완하는 목적으로 그 유용성이 클 것으로 기대함.
        4,000원
        188.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        콘크리트는 안전성과 경제성이 우수한 재료로 인식되어 많은 사회기반시설물의 건설재료로 이용되어 왔으나, 최근에는 노후화 현상 등으로 인한 성능저하가 발생하고 있으며 이는 직·간접적으로 경제적·인명적 피해의 원인이 되기 때문에 여러 가지 보강을 실시하고 있다. 본 연구에서는 복합섬유소재를 활용하는 보강공법을 포함한 다양한 보강공법에 대한 성능비교 실험연구를 수행하고 분석하였다.
        4,000원
        189.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목적 : 노안을 대상으로 멀티포컬 콘택트렌즈의 디자인에 따라 처방법을 다르게 하고 각각의 처방에 따른 시기 능을 비교하였다. 방법 : CNMF(center near multifocal) 콘택트렌즈를 성공적으로 착용하고 있는 초기노안 19명(남 3명, 여 16명, 평균연령 45.47±5.88세)을 대상으로 CDMF(center distance multifocal) 콘택트렌즈와 MMV(modified monovision) 콘택트렌즈를 각각 착용하도록 하고 처방법에 따라 시기능을 비교하였다. 시력검사는 ETDRS 시표 를 사용하여 측정하였고, 근거리 입체시력은 Stereo Fly Test를 이용하였으며, 시력 만족도는 NEI-VFQ-25 설 문지를 변형하여 측정하였다. 결과 : 처방법들에 따른 원거리 교정시력, 근거리 교정시력 및 입체시력은 차이가 없었다. 그러나 원거리 시력 만족도에 대한 설문조사에서는 야외광고를 볼 때와 낮에 운전을 할 때에는 CNMF, CDMF 착용 시 MMV보다 높 았고, 밤 운전 시에는 CDMF 착용 시에 가장 높았다(p<0.050). 중간거리 시력 만족도는 컴퓨터를 사용할 때와 밤에 계단을 오르내릴 때에는 CDMF와 MMV이 CNMF보다 높았다(p<0.050). 근거리 시력만족도는 신문 및 영수증을 볼 때에는 MMV이 CNMF, CDMF보다 높았으며, 전반적인 근거리 시력 만족도는 MMV 착용 시 높았다(p<0.050). 결론 : 세 가지 노안 교정법에 따라 시력은 차이가 없었지만 일상생활에서 시력 만족도는 주시거리와 환경에 따라 차이가 발생한다. 그러므로 착용자의 요구조건에 맞는 처방법을 선택한다면 멀티포컬 콘택트렌즈 착용 만족 도를 높일 수 있을 것으로 생각된다.
        4,200원
        190.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A new lighting support structure composing of two-way wires and pulley, a pulley-type wireway system, was developed to improve the seismic performance of a ceiling type lighting equipment. This study verifies the seismic performance of the pulley-type wireway system using a numerical approach. A theoretical model fitted to the physical features of the newly-developed system was proposed, and it was utilized to compute a frictional coefficient between the wire and pulley sections under tension forces. The frictional coefficient was implemented to a finite element model representing the pulley-type wireway system. Using the numerical model, the seismic responses of the pulley-type wireway system were compared to those of the existing lighting support structure, a one-way wire system. The addition of the pulley component resulted in the increasement of energy absorption capacity as well as friction effect and showed in significant reduction in maximum displacement and oscillation after the peak responses. Thus, the newly-developed wireway system can minimize earthquake-induced vibration and damage on electric equipment.
        4,000원
        191.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The resilience performance evaluation method of a structure can evaluate the ability to recover after an earthquake disaster, and this study deals with the consideration and introduction of the resilience performance evaluation method. The resilience evaluation method can be expressed as a quantified number by constructing a loss estimation model and a recovery evaluation model. The recovery evaluation model should consider downtime in addition to the repair time, and the loss estimation model should consider not only direct loss to structures and non-structures, but also indirect loss due to functional loss of the building. In addition, to build a loss estimation model, the structure should be simplified to perform an efficient analysis. Therefore, in this study, the equivalent terminal induction system proposed cantilever-type and rahmen-type SDOF, and it is evaluated somewhat conservatively compared to the example structure, and it is judged that there is a need to improve the hysteresis characteristics by applying the stiffness reduction factor of the SDOF model.
        4,000원
        194.
        2020.12 구독 인증기관 무료, 개인회원 유료
        This paper compares the preceding study on the development of evaluation indicator for ATOs for mechanics and vocational ability evaluation system implemented by the Ministry of Employment and Labor to support various vocational training. This paper also examines the systems for the protection and possible options of the consumer through disclosed notification and evaluation cases such as the traffic service evaluation system in the aviation sector. By extension, in order to ensure quality management and enhanced capability of flight schools, this paper aims to present a methodology for introducing an evaluation model certified by ATOs for pilots that emerges from comparing the preceding study on various vocational training applied with the CIPP evaluation model of Stufflebeam and the procedures for the designation of ATOs for pilots and follow-up management thereon in Korea, dividing it into four stages, which are the preparation stage, screening stage, designation stage and management stage, and applying the items and performance indicators to be carried out at each stage.
        4,300원
        197.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 단조가력 하중을 받는 실물크기 비닐온실의 기둥-서까래-도리 접합부의 역학적거동을 알아보기 위해 현장에서 시공되고 있는 두 가지 형식의 실험체로 구조실험을 수행하였다. 실험결과를 바탕으로 두 가지 형식의 접합부에 대해서 휨성능을 분석하고 접합부 분류를 시도하였다. Type B 는 Type A에 비해 휨 성능이 77% 수준으로 나타났으며 두 형식 모두 강성 및 휨내력이 강접합 수준에 미치지 못하는 것으로 나타났다. 기둥-서까래-도리 접합부의 거동은 용접부 및 체 결구 변형에 의한 국부좌굴이 지배적이었다. AISC 기준에 의한 접합부 분류 결과, Type A와 B 접합부 모두 설계 시 가정하는 강접합 성능에 미치지 못하는 결과를 보였으며 단순 접합으로 분류되는 것으로 나타났다. 따라서 접합부 성능평가 및 분류 결과, 접합부 성능을 고려한 온실 설계가 이루어져야 하며 신뢰성 높은 온실 구조설계를 위해서 온실 접합부에 대한 명확한 설계기준 정립 연구가 필요할 것으로 판단된다.
        4,000원
        198.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        중공슬래브 시스템은 슬래브 중앙부의 콘크리트를 경량의 중공재로 대체하여 중량은 감소시키면서 동등한 수준의 구조성능을 지니는 경제적인 시스템이나 콘크리트 타설 시 비중의 차이로 중공재가 부상하게 되는 문제점이 발생한다. 이에 본 연구에서는 중공슬래브 공법에 적용 가능한 경량성형재 고정장치를 고안하고 부력저항성능을 평가하고자 하였으며, 고정성능 평가를 위해 정해진 실험방법이 존재하지 않으므로 이를 검증하기 위해 인발실험장치를 제작하였다. 시공 시 본 장치를 설치하는 과정에서 발생 가능한 변수를 기준으로 실험을 수행하고자 하였고 이에 합판의 상태 및 고정 위치에 따라 변화되는 고정성능을 파악하고자 하였다. 인발 실험 결과 일반합판과 비교하여 코팅합판의 경우 구멍의 크기가 중공재 고정장치의 인장성능에 큰 영향을 미치지 않는 것으로 나타나 작업자의 편의 및 내력 확보의 안전성을 위해 코팅합판을 사용하는 것이 유리한 것으로 판단된다. 또한 고정 위치와 무관하게 동일한 수준의 고정성능을 지니는 것으로 보여져 설치 상태에 대한 별도의 확인 과정 없이 슬래브 상부에서 원터치 방식으로 고정 가능하므로 시공성이 향상된 것으로 사료된다.
        4,000원
        199.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper is to investigate the retrofitting effect for a non-seismic reinforced concrete frame strengthened by perimeter steel moment frames with indirect integrity, which ameliorates the problems of the direct integrity method. To achieve this, first, full-scale tests were conducted to address the structural behavior of a two-story non-seismic reinforced concrete frame and a strengthened frame. The non-seismic frame showed a maximum strength of 185 kN because the flexural-shear failure at the bottom end of columns on the first floor was governed, and shear cracks were concentrated at the beam-column joints on the second floor. The strengthened frame possessed a maximum strength of 338 kN, which is more than 1.8 times that of the non-seismic specimen. A considerable decrease in the quantity of cracks for the strengthened frame was observed compared with the non-seismic frame, while there was the obvious appearance of the failure pattern due to the shear crack. The lateral-resisting capacity for the non-seismic bare frame and the strengthened frame may be determined per the specified shear strength of the reinforced columns in accordance with the distance to a critical section. The effective depth of the column may be referred to as the longitudinal length from the border between the column and the foundation. The lateral-resisting capacity for the non-seismic bare frame and the strengthened frame may be reasonably determined per the specified shear strength of the reinforced columns in accordance with the distance to a critical section. The effective depth of the column may be referred to as the longitudinal length from the border between the column and the foundation. The proposed method had an error of about 2.2% for the non-seismic details and about 4.4% for the strengthened frame based on the closed results versus the experimental results.
        4,000원
        200.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the Buckling restrained braces reinforced with engineering plastics that can compensate for the disadvantages in the manufacturing process of the existing buckling restrained brace. The proposed PC-BRB was fabricated to evaluate the reinforcement effect by carrying out a structural performance test and a full-scale two-layer frame test through cyclic loading test. As a result of PC-BRB's incremental and cyclic loading test, stable hysteresis behavior was achieved within the target displacement, and the compressive strength adjustment coefficient satisfied the recommendation. As a result of the real frame experiment, the strength of the reinforced specimen increased compared to the unreinforced specimen, and the ductility and energy dissipation increased.
        4,000원