        21.
        2021.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The dynamic characterization of a three-story auxiliary building in a nuclear power plant (NPP) constructed with a monolithic reinforced concrete shear wall is investigated in this study. The shear wall is subjected to a joint-research, round-robin analysis organized by the Korea Atomic Energy Research Institute, South Korea, to predict seismic responses of that auxiliary building in NPP through a shake table test. Five different intensity measures of the base excitation are applied to the shaking table test to get the acceleration responses from the different building locations for one horizontal direction (front-back). Simultaneously to understand the global damage scenario of the structure, a frequency search test is conducted after each excitation. The primary motivation of this study is to develop a nonlinear numerical model considering the multi-layered shell element and compare it with the test result to validate through the modal parameter identification and floor responses. In addition, the acceleration amplification factor is evaluated to judge the dynamic behavior of the shear wall with the existing standard, thus providing theoretical support for engineering practice.
        4,000원
        22.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        확률론적 지진취약도 평가는 구조물 혹은 기기의 손상확률을 각 취약도 변수별 조합을 통해 이루어진다. 지진취약도로부터 구해지는 2개 이상 기기의 동시손상확률 계산은 기존에는 각 기기의 손상확률을 독립으로 가정해왔다. 하지만 기기별 손상확률에 상관성이 있으며, 이를 평가한 결과 상관성에 따라 동시손상확률이 변화할 수 있는 결과를 보였다. 이 지진상관성을 무시하면 비보수적인 결과가 나오고 따라서 이를 고려해서 계산되어야 한다. 이 연구에서는 지진상관계수를 해석적으로 평가하기 위해 몇 가지 확률 변수를 선정하여 각 변수별로 혹은 통합하여 평가하고 그 차이를 비교했다. 그리고 단순화된 모델과, 복잡한 모델에 대한 상관계수 차이도 비교 하였다. 이들 방법에 따른 상관계수의 결과와 차이를 분석했다. 그 결과 각 변수별로 평가하는 것과 통합하여 평가할 때 변수별 영향의 차이에 따라 상관성이 변화함을 확인하였고, 모델이 단순할수록 상관성이 높아짐을 확인하였다.
        4,000원
        23.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        현재 우리나라에서 운영 중인 교량 중 30년 이상 된 교량이 전체의 약 11%를 차지할 정도로 노후교량의 수가 증가하고 있다. 따라 서 교량의 노후화에 따른 영향을 고려한 내진성능 평가방법의 개발이 필요하다고 볼 수 있다. 예제 교량으로는 포트받침, 탄성고무받 침과 납-고무받침을 가진 3가지의 강합성 상자형 거더교를 선정하고, opensees 프로그램을 사용하여 구조해석모델을 작성하였다. 본 연구에서는 교량의 노후도를 교각의 주철근과 띠철근의 부식에 의한 면적의 감소로 반영하였다. 교각의 노후화 정도로는 5%, 10%, 25%, 50%의 4가지 조건을 사용하였다. 입력지진으로는 근거리 지진과 원거리 지진을 각각 40개씩 사용하였으며, 노후화 정도에 따른 예제교량의 교각에 대한 최대변위와 최대 전단력 응답을 구하여 비교하였다. 노후도가 증가할수록 힘-변위 관계에서 교각의 강도 저하가 발생함을 알 수 있으며, 이로 인하여 교각의 변위응답이 증가함을 알 수 있다. 교각의 노후도에 따른 변위응답과 전단저항능력의 영향을 분석하기 위하여 변위비(Dratio)와 전단력비(Fratio)를 정의하여 평가하였다. 예제교량의 고유주기가 길어질수록 노후도에 따른 변위비(Dratio)의 증가가 크게 나타남을 알 수 있으며, 전단력비(Fratio)의 감소 경향은 작게 나타남을 알 수 있다.
        4,200원
        24.
        2020.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        여러 센서를 이용한 구조물의 구조 응답을 모니터링하는 사례가 증가하고 있다. 그러나 비용과 관리 문제로 인해 제한된 센서만이 구조물에 설치되어 일부의 구조 응답만을 수집하는 경우가 대부분이다. 이는 구조물의 전체 거동을 분석하는데 장애요소로 작용하게 된다. 따라서 제한된 센서를 이용해 센서가 설치되지 않은 위치에서의 응답을 신뢰할 수 있는 수준으로 예측하는 기술이 필요하다. 본 연구에서는 제한된 정보를 이용해 저층 건물 구조물의 지진 응답을 예측하는 해석적 연구를 수행한다. 활용 가능한 응답 정보는 1층과 최상층의 가속도 응답만을 사용할 수 있다고 가정한다. 두 정보를 이용하면 구조물의 1차 고유진동수를 얻을 수 있다. 1층 가속도 정보는 구조물의 가력 정보로 활용한다. 최상층의 가속도이력응답에 대한 오차와 대상 구조물의 1차 고유진동수 오차를 최소화하는 구조물의 질량과 강성 정보를 유전자알고리즘을 이용해 예측하는 기법을 제시한다. 제약조건은 고려하지 않는다. 탐색공간을 의미하는 설계변수의 범위를 결정하기 위해 인공신경망 기반의 파라미터 예측기법을 제시한다. 또한 유전자알고리즘을 통해 얻게 되는 해를 개선시키기 위해 앞서 언급한 인공신경망을 활용한다. 제시한 기법을 검증하기 위해 5층 구조물 예제를 사용한다.
        4,000원
        25.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, deep learning that is the most popular and effective class of machine learning algorithms is widely applied to various industrial areas. A number of research on various topics about structural engineering was performed by using artificial neural networks, such as structural design optimization, vibration control and system identification etc. When nonlinear semi-active structural control devices are applied to building structure, a lot of computational effort is required to predict dynamic structural responses of finite element method (FEM) model for development of control algorithm. To solve this problem, an artificial neural network model was developed in this study. Among various deep learning algorithms, a recurrent neural network (RNN) was used to make the time history response prediction model. An RNN can retain state from one iteration to the next by using its own output as input for the next step. An eleven-story building structure with semi-active tuned mass damper (TMD) was used as an example structure. The semi-active TMD was composed of magnetorheological damper. Five historical earthquakes and five artificial ground motions were used as ground excitations for training of an RNN model. Another artificial ground motion that was not used for training was used for verification of the developed RNN model. Parametric studies on various hyper-parameters including number of hidden layers, sequence length, number of LSTM cells, etc. After appropriate training iteration of the RNN model with proper hyper-parameters, the RNN model for prediction of seismic responses of the building structure with semi-active TMD was developed. The developed RNN model can effectively provide very accurate seismic responses compared to the FEM model.
        4,000원
        26.
        2020.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Analysis of the 2016 Gyeongju earthquake and the 2017 Pohang earthquake showed the characteristics of a typical high-frequency earthquake with many high-frequency components, short time strong motion duration, and large peak ground acceleration relative to the magnitude of the earthquake. Domestic nuclear power plants were designed and evaluated based on NRC's Regulatory Guide 1.60 design response spectrum, which had a great deal of energy in the low-frequency range. Therefore, nuclear power plants should carry out seismic verification and seismic performance evaluation of systems, structures, and components by reflecting the domestic characteristics of earthquakes. In this study, high-frequency amplification factors that can be used for seismic verification and seismic performance evaluation of nuclear power plant systems, structures, and equipment were analyzed. In order to analyze the high-frequency amplification factor, five sets of seismic time history were generated, which were matched with the uniform hazard response spectrum to reflect the characteristics of domestic earthquake motion. The nuclear power plant was subjected to seismic analysis for the construction of the Korean standard nuclear power plant, OPR1000, which is a reactor building, an auxiliary building assembly, a component cooling water heat exchanger building, and an essential service water building. Based on the results of the seismic analysis, a high-frequency amplification factor was derived upon the calculation of the floor response spectrum of the important locations of nuclear power plants. The high-frequency amplification factor can be effectively used for the seismic verification and seismic performance evaluation of electric equipment which are sensitive to high-frequency earthquakes.
        4,000원
        27.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Seismic responses due to the dynamic coupling between a primary structure and secondary system connected to a structure are analyzed in this study. The seismic responses are compared based on dynamic coupling criteria and according to the error level in the natural frequency, with the recent criteria being reliant on the error level in the spectral displacement response. The acceleration responses and relative displacement responses of a primary structure and a secondary system for a coupled model and two different decoupled models of two degrees-of-freedom system are calculated by means of the time integration method. Errors in seismic responses of the uncoupled models are reduced with the recent criteria. As the natural frequency of the secondary system increases, error in the natural frequency decreases, but seismic responses of uncoupled models can be underestimated compared to that of coupled model. Results in this paper can help determine dynamic coupling and predict uncoupled models’ response conservatism.
        4,000원
        28.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to optimize the cochlea-inspired artificial filter bank (CAFB) using El-Centro seismic waveforms and test its performance through a shaking table test on a two-span bridge model. In the process of optimizing the CAFB, El-Centro seismic waveforms were used for the purpose of evaluating how they would affect the optimizing process. Next, the optimized CAFB was embedded in the developed wireless-based intelligent data acquisition (IDAQ) system to enable response measurement in real-time. For its performance evaluation to obtain a seismic response in real-time using the optimized CAFB, a two-span bridge (model structures) was installed in a large shaking table, and a seismic response experiment was carried out on it with El-Centro seismic waveforms. The CAFB optimized in this experiment was able to obtain the seismic response in real-time by compressing it using the embedded wireless-based IDAQ system while the obtained compressed signals were compared with the original signal (un-compressed signal). The results of the experiment showed that the compressed signals were superior to the raw signal in response performance, as well as in data compression effect. They also proved that the CAFB was able to compress response signals effectively in real-time even under seismic conditions. Therefore, this paper established that the CAFB optimized by being embedded in the wireless-based IDAQ system was an economical and efficient data compression sensing technology for measuring and monitoring the seismic response in real-time from structures based on the wireless sensor networks (WSNs).
        4,000원
        29.
        2020.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 원자로 1400(APR 1400) 원자력 발전소(NPP)의 원자로 격납건물(RCB) 내진성능에 대해 상이한 수치모델과 지진 주파수 성분의 영향을 평가하는 것이다. 집중 질량 막대 모델(lumped-mass stick model, LMSM)과 3차원 유한요소모델(threedimensional finite element model, 3D FEM)의 두 가지 수치 모델이 시간이력해석을 수행하기 위해 개발되었다. LMSM은 기존의 집중 질량 보-요소를 사용하여 SAP2000으로 구성하였으며, 3D FEM은 각기둥 입체-요소를 사용하여 ANSYS로 작성되었다. 저주파수 및 고주파수 성분을 고려한 두 그룹의 지진파를 시간이력해석에 적용하였다. 저주파수 지진파의 응답스펙트럼을 NRC 1.60의 설계 스펙트럼과 일치되도록 조정하여 작성하였으며, 고주파수 지진파는 10Hz ~ 100Hz의 고주파수 범위를 갖도록 생성하였다. RCB의 지진응 답은 다양한 높이에서 층응답스펙트럼으로 검토하였다. 수치해석 결과, 저주파수 지진에 의한 구조물의 FRS 결과는 두 수치 모델에 서 매우 유사한 결과를 보였다. 하지만, 고주파수 지진에 의한 LMSM의 FRS 결과는 고차 고유 주파수 영역에서 3D FEM과 큰 차이를 보였으며, RCB의 낮은 높이에서 명확한 차이를 보였다. 3D FEM이 정확한 구조물의 응답을 나타내는 것으로 가정한다면, RCB의 LMSM은 고주파수 지진에 의한 FRS 결과의 고차 고유 주파수 영역에서 일정 수준의 불일치성을 내포하고 있다.
        4,000원
        30.
        2020.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 국내에서 발생한 경주지진 및 포항지진이 도심지 및 원자력발전소 주변에서 발생함에 따라 인근 주요 구조시스 템에 피해를 발생시킨 바 있다. 이에 따라, 본 연구는 원전 배관계통의 지진 거동 특성을 실험 및 해석적으로 규명하고, 이를 바탕으로 내진성능을 평가하는 연구를 수행하는 것을 목적으로 한다. 이를 위하여, 원전 배관계통을 대상으로 한 진동대 시험 결과를 바탕으로 배관 수치해석 모델을 수립하고 이를 시험 결과를 통하여 검증한다. 또한, 이러한 검증된 수치해석모델을 기반으로 배관계통의 내진성능을 평가한다. 수치해석 모델 검증 결과, 수립된 수치모델의 고유진동수, 감쇠비 및 변위 응답이 진동 대시험 결과와 유사한 것으로 나타났다. 이러한 검증된 수치모델을 바탕으로 평가된 내진성능 값은 기존 원전 배관의 내진성능 값의 범위와 비교적 유사한 값으로 평가되었다. 이는 설계기준지진을 크게 상회하는 값이지만, 원전 주요 기기 임을 감안할 때 추가적인 내진성능 상향이 확보되면 원전 지진 안전성 향상에 많은 기여를 할 수 있을 것으로 판단된다. 본 연구의 결과는 추후 원전 배관계통 내진성능평가를 위한 정량적인 자료로 활용이 가능할 것으로 판단된다.
        4,000원
        31.
        2020.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In 2016, an earthquake occurred at Gyeongju, Korea. At the Wolsong site, the observed peak ground acceleration was lower than the operating basis earthquake (OBE) level of Wolsong nuclear power plant. However, the measured spectral acceleration value exceeded the spectral acceleration of the operating-basis earthquake (OBE) level in some sections of the response spectrum, resulting in a manual shutdown of the nuclear power plant. Analysis of the response spectra shape of the Gyeongju earthquake motion showed that the high-frequency components are stronger than the response spectra shape used in nuclear power plant design. Therefore, the seismic performance evaluation of structures and equipment of nuclear power plants should be made to reflect the characteristics of site-specific earthquakes. In general, the floor response spectrum shape at the installation site or the generalized response spectrum shape is used for the seismic performance evaluation of structures and equipment. In this study, a generalized response spectrum shape is proposed for seismic performance evaluation of structures and equipment for nuclear power plants. The proposed response spectrum shape reflects the characteristics of earthquake motion in Korea through earthquake hazard analysis, and it can be applied to structures and equipment at various locations.
        4,000원
        32.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Spatial structure does not have columns and walls installed inside, so they have a large space. There are upper structure and substructure supporting them. The response of seismic loads to the upper structure may be increased or decreased due to the effects of the substructure. Therefore, in this study, the seismic response of the upper structure and the floor response spectrum of the substructure were compared and analyzed according to the height of the substructure in the spatial structure where the LRB was installed. As a result, the possibility of amplification of response was confirmed as seismic waves passed though the substructure, which is likely to increase the response of the upper structures.
        4,000원
        33.
        2019.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The number of aged bridges is increasing so that bridges over 30 years old account for about 11% of all bridges. Consequently, the development of a seismic performance evaluation method that considers the effects of ageing is essential for a seismic retrofitting process for improvement of the seismic safety of existing old bridges. Assessment of the damage situation of bridges after the recent earthquakes in Korea has been limited to the bearings, anchor, and concrete mortar on piers. The purpose of this study is to evaluate the seismic responses of PSC box girder bridges by considering the ageing effect of rubber bearings (RBs) and lead-rubber bearings (LRBs). The modification factor proposed by AASHTO is used to take into account the ageing effect in the bearings. PSC box girder bridges with RBs and LRBs were 3D modeled and analyzed with the OpenSEES program. In order to evaluate the ageing effect of RBs and LRBs, 40 near fault and 40 far field records were used as the input earthquakes. When considering the effect of ageing, the displacement responses and shear forces of bridge bearings (RBs and LRBs) were found to increase mostly under the analytical conditions. It was shown that the effect of ageing is greater in the case of RBs than in the case of LRBs.
        4,000원
        34.
        2019.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the retractable-roof spatial structure was chosen as the analytical model and a tuned mass damper (TMD) was installed in the analytical model in order to control the seismic response. The analysis model is mainly consisted of runway trusses (RT) and transverse trusses (TT), and the displacement response was analyzed by installing TMD on those trusses. The mass of the single TMD which is installed in the analytical model was set to 1% of the total structure mass and the total TMD mass ratio was set to be 8% or 6%. In addition, the mass of a single TMD was varied depending on the number of installations. As a result of analyzing the optimal number of installations of TMD, the displacement response was reduced in all cases compared to the case without TMD. Above all, the case with 8 TMDs was the most effective in reducing he displacement response. However, in this case, as the load on the upper structure of the retractable-roof spatial structure increases, the total mass ratio of TMD was maintained and the number of TMDs was increased to reduce the mass ratio of one TMD.
        4,000원
        35.
        2019.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Several water tanks installed in the building were damaged during the Gyeongju earthquake (2016) and the Pohang earthquake (2017). Since a water tank for fire protection is very important component, seismic safety should be ensured. In this study, an interaction between a water tank and a building was studied by the dynamic analysis of the RC building with the water tank. In case the water tank was installed on the roof of the RC building, it was confirmed that it did not significantly affect the response of the building. Based on the result, dynamic response characteristics of the water tank in the building were studied using two SDOF models represented dynamic behavior of the water tanks under earthquake. An earthquake time-history analysis was carried out with variables of aspect ratio of the tank, story of the building, and installed location in the building using three kinds of earthquakes.
        4,000원
        36.
        2019.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Response modification factors of school facilities for non-seismic RC moment frames with partial masonry infills in ‘Manual for Seismic Performance Evaluation and Retrofit of School Facilities’ published in 2018 were investigated in the preceding study. However, since previous studies are based on 2D frame analysis and limited analysis conditions, additional verification needs to be performed to further apply various conditions including orthogonal effect of seismic load. Therefore, this study is to select appropriate response modification factors of school facilities for non-seismic RC moment frames with partial masonry infills by 3D frame analysis. The results are as follows. An appropriate response modification factor for non-seismic RC moment frames with partial masonry infills is proposed as 2.5 for all cases if the period is longer than 0.6 seconds. Also if the period is less than 0.4 seconds and the ratio of shear-controlled columns is less than 30%, 2.5 is chosen too. However, if the period is less than 0.4 seconds and the ratio of shear-controlled columns is higher than 30%, the response modification factor shall be reduced to 2.0. If the period is between 0.4 and 0.6 seconds, then linearly interpolates the response correction factor.
        4,000원
        37.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the seismic response is investigated by using a relatively low-rise building under torsion-prone conditions and three seismic loads with change of the location of the seismic isolation system. LRB (Lead Rubber Bearing) was used for the seismic isolator applied to the analytical model. Fixed model without seismic isolation system was set as a basic model and LB models using seismic isolation system were compared. The maximum story drift ratio and the maximum torsional angle were evaluated by using the position of the seismic layer as a variable. It was confirmed that the isolation device is effective for torsional control of planar irregular structures. Also, it was shown that the applicability of the midstory seismic isolation system. Numerical analyses results presented that an isolator installed in the lower layer provided good control performance for the maximum story drift ratio and the maximum torsional angle simultaneously.
        4,000원
        38.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the precedent study, the retractable-roof spatial structure was selected as the analytical model and a tuned mass damper (TMD) was installed to control the dynamic response for the earthquake loads. Also, it is analyzed that the installation location of TMD in the analytical model and the optimal number of installations. A single TMD mass installed in the analytical model was set up 1% of the mass of the whole structure, and the optimum installation location was derived according to the number of change. As a result, it was verified that most effective to install eight TMDs regardless of opening or closing. Thus, in this study, eight TMDs were installed in the retractable-roof spatial structure and the optimum mass ratio was inquired while reducing a single TMD. In addition, the optimum mass distribution ratio was identified by redistributing the TMD masses differently depending on the installation position, using the mass ratio of vibration control being the most effective for seismic load. From the analysis results, as it is possible to confirm the optimum mass distribution ratio according to the optimum mass ratio and installation location of the TMD in the the retractable-roof spatial structure, it can be used as a reference in the TMD design for large space structure.
        4,000원
        39.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study is to investigate the earthquake response for the design of 100m spanned single-layer lattice dome. The plastic hinge analysis and eigenvalue buckling analysis are performed to estimate the ultimate load of single-layered lattice domes under vertical loads. In order to ensure the stability of lattice domes, it is investigated for the plastic hinge progressive status by the pushover increment analysis considering the elasto-plastic connection. One of the most effective methods to reduce the earthquake response of large span domes is to install the LRB isolation system of a dome. The authors discuss the reducing effect for the earthquake dynamic response of 100m spanned single-layered lattice domes. The LRB seismic isolation system can greatly reduce the dynamic response of lattice domes for the horizontal and vertical earthquake ground motion.
        4,300원
        40.
        2019.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Most school buildings consist of reinforced concrete (RC) moment frames with masonry infills. The longitudinal direction frames of those school buildings are relatively weak due to the short-column effects caused by the partial masonry infills and need to be evaluated carefully. In ‘Manual for Seismic Performance Evaluation and Retrofit of School Facilities’ published in 2018, response modification factor of 2.5 is applied to non-seismic RC moment frames with partial masonry infills, but sufficient verification of the factor has not been reported yet. Therefore, this study conducted seismic performance evaluation of planar RC moment frames with partial masonry infills in accordance with both linear analysis and nonlinear static analysis procedures presented in the manual. The evaluation results from the different procedures are compared in terms of assessed performance levels and number of members not meeting target performance objectives. Finally, appropriate response modification factors are proposed with respect to a shear-controlled column ratio.
        4,300원