검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 266

        41.
        2018.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we develop and propose damping correction factors for the Korean standard design spectra. The newly proposed Korean standard design spectra has been given only for 5% damping ratio. But in practice, engineers need design spectra for damping values other than 5%. To obtain design spectra for various damping values from the standard spectra, damping correction factors are derived. These factors modify the shape of design spectra in accordance with the damping ratio. Response spectra for various damping values are calculated from the earthquake records that had been used to calculate standard design spectra. They consist of 55 records from 18 earthquakes occurred in overseas intraplate regions and Korea. The regressed spectra for the damping values ranging from 0.5% to 50% are compared with standard spectra at three regions acceleration, velocity and displacement sensitive regions. The regression analysis of these data rendered formula for damping correction factors. Finally, a single formula for damping correction factors is recommended that is valid for both horizontal and vertical design spectra and that is applicable to the entire range of periods. One thing to note that recommended damping correction factors is valid for the design spectrum of the rock grounds because the design spectra was developed based on the earthquake records of the rock ground.
        4,600원
        42.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        구조물의 감쇠비는 내풍성능을 평가하는 가장 중요한 요소 중의 하나이다. 구조물의 실제 감쇠비는 대부분 계측된 응답을 기반으로 시스템 식별기술에 의하여 이루어진다. 그러나 예측된 감쇠비는 계측조건, 계측시간 및 시스템 식별기술에 따라 오차를 보이는 등 불확실성을 가지고 있다. 본 연구에서는 기 개발된 가상 동적진동기(Virtual Dynamic shaker)에 주요 개념으로 사용되었던 외부하중 스펙트럼의 전체 평탄성을 국부 평탄성으로 개념을 확대하여 감쇠비 추정을 보다 정교하게 하는 기법을 개발하였다. 국부 평탄성을 개념을 사용하여 감쇠비를 구하고자 하는 대상 모드의 고유진동수 부근에 적용함으로서 보다 정확하게 감쇠비 추정하는 기법을 다루었다. 본 개발된 기법을 검증하기 위하여 고층건물의 상시진동에 대하여 적용하였으며, 기존 시스템 식별법, 자유진동실험에 의한 결과와 비교 평가하였다. 그 결과 전체 평탄성을 가지는 개념에 비하여 국부평탄성을 가지는 VDS가 보다 정확하게 감쇠비를 추정하는 것을 보였다.
        4,000원
        43.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        대부분의 기존 송전철탑은 산악지형에 위치하여 강풍에 노출되어 있으며 이러한 강풍은 송전철탑에 동적하중의 증폭을 유도한다. 그러나 송전철탑은 일반적으로 이러한 동적하중을 직접 고려하지 않고, 단순히 등가정적하중을 사용하여 설계된다. 따 라서 기존의 송전철탑 보강방법으로는 정적응답을 줄이는 관점에서 단면 증대나 좌굴길이 감소 등의 방법이 사용되었다. 실제 동 적하중조건의 경우, 감쇠성능을 증가시킬 수 있는 보강기구가 보강방안의 대안으로 고려될 수 있다. 본 연구에서는 송전철탑의 동적모델을 구축하였고, 비선형 시간이력해석을 수행하였다. 풍하중은 풍동실험을 통해 구하였으며, 마찰감쇠기가 강성과 감쇠 를 동시에 증가시키기 위해 적용되었다. 수치해석 결과는 마찰감쇠기의 최적 항복강도가 최하단 주주재가 부담했던 축하중의 5- 10% 임을 보여준다. 토글형 마찰감쇠기와 강성보강을 동시에 수행함으로써 주주재의 부재력과 기초에 전달되는 하중을 크게 저 감시킬 수 있었다.
        4,300원
        44.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study develops a new hybrid passive energy dissipation device for seismic rehabilitation of an existing structure. The device is composed of a friction damper combined with a steel plate with vertical slits as a hysteretic damper. Analytical model is developed for the device, and the capacity of the hybrid device to satisfy a given target performance is determined based on the ASCE/SEI 7-10 process. The effect of the device is verified by nonlinear dynamic analyses using seven earthquake records. The analysis results show that the dissipated inelastic energy is concentrated on the hybrid damper and the maximum interstory drift of the SMRF with damping system satisfies the requirement of the current code.
        4,000원
        45.
        2017.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The damping effects on stabilities of a simply supported pipe conveying fluid is investigated using the complexification-averaging method. The flow is assumed to vary harmonically about a mean speed. Unstable conditions of a piping system included with the viscous and material damping are analytically obtained for primary, secondary and combination parametric resonances. The primary and secondary resonances occur when the frequency of flow fluctuation is close to one and two times the natural frequency. And when this frequency is close to the sum of any two natural frequencies, combination resonances occur. The effects of damping parameters on the regions of three parametric resonances are discussed.
        4,000원
        46.
        2017.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        구조물의 성능을 개선하기 위하여 다양한 진동제어장치가 사용되고 있다. 대부분의 제진장치는 구조물의 감쇠비를 증가시킴으로써 성능개선효과를 유도하기 때문에 증가된 감쇠비는 제진장치에 의한 구조물의 성능을 평가하는 중요한 지표가 될 수 있다. 본 연구에서는 강풍 등으로 제진장치가 운영 중인 상태에서 구조물의 응답만을 이용하여 각 모드에 증가된 등가감쇠비를 추정하는 프로세스를 개발하고 이를 성능개선효과를 평가하는데 활용하고자한다. 제진장치가 설치된 구조물은 비고전 감쇠시스템이므로 상태공간 모드분해법을 이용하여 계측응답으로부터 모드 응답을 구하고, 분해된 모드응답에 가상 동적 진동기를 적용하여 각 모드에 증가된 감 쇠비를 구하였다. 제안된 제진장치 설치 구조물 감쇠비 추정법을 검증하기 위하여 수동형 제진장치로 카고메 점탄성 댐퍼를, 능동형 제진장치로 능동질량감쇠기를 구조물에 적용하여 각 제진장치에 의한 감쇠비를 추정한 결과 매우 정교하게 예측 가능함을 알 수 있었다.
        4,000원
        47.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper presents a vibration mitigation method for a railroad station using dual layer TMD (Tuned Mass Damper) technology. The proposed technology can be applied to a platform by installing a spring-damper system between the platform and the railroad station structure. Especially, considering passenger comfort, the technology is developed for not just reducing the vibration of the railroad station structure but minimizing the vibration of the platform. The technology consists of two serially connected masses, and the vibration of the top mass is designed to be minimized, while the bottom mass serves as the platform TMD. The design parameters such as the spring constant and damping coefficient of the dual layer TMD system are optimized using the acceleration response of the structure, at which the platform is installed. The feasibility and performance of the vibration mitigation method is verified via a numerical example of a simple beam structure subjected to a moving load, which can be analogized as a railroad station with a moving train on top. The result of the numerical study shows that the proposed method can effectively reduces the vibration of the top mass as well as the beam structure at the design speed of the moving load.
        4,000원
        48.
        2017.04 구독 인증기관 무료, 개인회원 유료
        Wind tower structure has relatively simple shape compared to other structures, but due to its characteristics, various and irregular environmental loads are applied. These loads cause vibrations at tower, and can cause failure of the structure if over vibration occurs. Vibration occurred at structures is gradually exhausted by damping of the structures, and if high damping is ensured, the failure of the structure due to over vibration can be prevented. In this study, the vibration reduction effects are to be analyzed through FEM analysis by examining the top displacement, bottom moment, and bottom fatigue damage of the structure depending on damping ratio of the wind tower structure.
        3,000원
        49.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper presents a dynamic crack propagation algorithm with Rayleigh damping effect based on the MLS(Moving Least Squares) Difference Method. Dynamic equilibrium equation and constitutive equation are derived by considering Rayliegh damping and governing equations are discretized by the MLS derivative approximation; the proportional damping, which has not been properly treated in the conventional strong formulations, was implemented in both the equilibrium equation and constitutive equation. Dynamic equilibrium equation including time relevant terms is integrated by the Central Difference Method and the discrete equations are simplified by lagging the velocity one step behind. A geometrical feature of crack is modeled by imposing the traction-free condition onto the nodes placed at crack surfaces and the effect of movement and addition of the nodes at every time step due to crack growth is appropriately reflected on the construction of total system. The robustness of the proposed numerical algorithm was proved by simulating single and multiple crack growth problems and the effect of proportional damping on the dynamic crack propagation analysis was effectively demonstrated.
        4,000원
        50.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, effectiveness of seismic retrofitting methods using passive damping devices was investigated through numerical analyses of short-period structures under earthquakes which have short-duration and high-frequency impulse characteristics similar to Geyongju earthquakes. Displacement spectra of elastic systems and ductility demand of inelastic systems were evaluated by increasing viscous or friction damping. The damping devices could reduce responses of the structures with shorter structural period than 0.2s. The earthquakes similar to impulse load did not induce the responses of the structures with longer period than 0.4s, and the effects of the damping devices which generates damping forces proportional to structural responses became insignificant.
        4,000원
        52.
        2016.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        This study was carried out to investigate the effect of deformation induced martensite on the damping capacity of Fe-26Mn-4Co-2Al damping alloy. α‘ and ε-martensite were formed by cold working, and; deformation induced martensite was formed with according to the specific direction and the surface relief. With an increasing degree of cold rolling, the volume fraction of α‘-martensite increased rapidly, while the volume fraction of ε-martensite decreased after rising to a maximum value at a specific level of cold rolling. Damping capacity was increased, and then decreased with an increasing of the degree of cold rolling. Damping capacity was influenced greatly by the volume fraction of ε-martensite formed by cold working, but the effect of the volume fraction of α‘-martensite have a actually on effect on the damping capacity.
        4,000원
        53.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 풍하중을 받는 건물에 설치된 다중거동 복합 감쇠장치(MHD)의 성능을 평가하고, MHD 예비설계 절차를 제안하였다. MHD에 의해 증가된 등가감쇠비와 그에 따른 건축구조기준에 근거한 응답저감계수를 예상한 후, 풍하중 스펙트럼에 의해 생성된 풍하중을 사용하여 20층 철골구조물에 대한 시간이력 해석을 수행하였다. 해석결과를 통해 얻어진 층변위 및 층간변위 평균 응답 감소율은 각각 0.585 및 0.525로, 이는 제안한 예비설계과정에서 추정된 응답감소계수 0.6과 거의 동일한 수치임을 확인하였다. 이로부터 제안된 방법을 사용하여 MHD의 제어효과를 효과적으로 평가할 수 있음을 확인하였다.
        4,000원
        54.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In recent years, an outrigger damper system has been proposed to reduce dynamic responses of tall buildings. However, a study on outrigger damper system is still in its early stages. In this study, time history analysis was performed to investigate the dynamic response control performance of outrigger damper. To do this, a actual scale 3-dimensional tall building model with outrigger damper system has been developed. El Centro earthquake was applied as an earthquake excitation. The control performance of the outrigger damper system was evaluated by varying stiffness and damping values. Analysis results, on the top floor displacement response to the earthquake load, was greatly effected by damping value. And acceleration response greatly was effected by stiffness value of damper system. Therefore, it is necessary to select that proper stiffness and damping values of the outrigger damper system.
        4,000원
        55.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The proposed hybrid damper installs at a coupling beam and consists of a high-damping rubber (HDR) and steel pin. The proposed hybrid damper adopted a pin-lock system acts as a viscoelastic damper under wind load (small displacement) while it behaves as a hysteretic damper under earthquake load (large displacement). In this paper, the pin-lock mechanism and structural performance of the proposed hybrid damper is evaluated through experiment. Experiments were carried out with the variables which displacement, loading frequency and steel pin quantities were used. Test results showed that the pin-lock mechanism and the performance of the hybrid damper under a large displacement were verified. Also equivalent damping ratios of HDR were increasing at a small displacement as displacement amplitudes were increasing. However HDR did not depend on frequency,
        4,000원
        56.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        동조액체감쇠기(TLD)는 에너지 소산장치로써 구조물의 동적응답을 제어하기 위해 개발되었다. TLD는 풍하중에 의한 구조물의 응답을 제어에 매우 효과적임을 보여줬다. 그러나 TLD가 설치된 구조물의 지진응답의 제어에 대해서는 충분한 연구가 이뤄지지 않았다. 이 연구의 목적은 TLD가 설치된 구조물에 여러 동조비와 질량비를 대입하여 지진에 대한 TLD의 성능을 도출하는 것이다. 이러한 목적을 위해, 수치해석 연구가 실시되며, 다른 토양 조건 또한 고려되었다. 그 결과 지진하중에 대한 TLD의 성능은 구조물의 고유주기, 감쇠비에 따라 다르게 나타났다. 또한 TLD의 동조비 다르게 나타남을 알 수 있었다.
        4,000원
        58.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 가상 질량 동조기(VMT)를 이용하여 구조물의 응답으로부터 구조물의 감쇠비를 구하는 기법을 다룬다. 백색잡음 뿐만아니라, 특정 진동수 가진, 충격하중 가진 등 다양한 하중종류 및 특성에 의하여 발생한 구조물의 계측응답에 대하여 VMT를 적 용하였을 때 구조물의 감쇠비를 추정하는 기법에 대해서 다루고, VMT의 동적특성이 구조물 감쇠비 추정에 미치는 영향을 수치적으로 분석하였다. 수치해석결과에 의하면, VMT에 의하여 구조물 감쇠비 추정이 충분한 신뢰성을 가지고 예측되는 것을 확인 할 수 있었다. 충격하중을 받는 응답을 이용하는 경우 VMT에 의하여 가장 안정적으로 구조물 감쇠비 추정이 가능한 것을 알 수 있었으며, 백색잡음, 협소대역 하중에 대해서도 VMT의 지정 감쇠비를 너무 작게 산정하지 않으면 감쇠비 추정이 가능한 것으로 나타났다. 정현파의 경우에는 가진 진동수의 VMT 비율을 이용하여 감쇠비 추정이 가능한데 고유진동수와 인접할수록 정밀도가 높아지는 것을 알 수 있었다.
        4,000원
        59.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        It has been many efforts for reinforcement of existing structure since the number of earthquake has been increased world widely. Especially the occurrence of earthquake surrounding area of Korean peninsular is dramatically increased. Since the buildings in Korea have not been designed to carry the lateral and shear force caused by earthquake, the building will experience massive damages even under moderate earthquake. For this reason, the viscoelastic damper is proposed in this paper to enhance the earthquake resistance of a steel frame buildings. The viscoelastic dampers have been able to increase the overall damping of the structure significantly, hence improving the overall performance of dynamically sensitive structures. In this paper, Viscoelastic dampers designed are consists of FRP panel and viscoelastic material. In this paper, evaluate the performance of the viscoelastic damper through the experiment.
        4,000원
        60.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 변위응답 및 가속도 응답의 저감 효과에 있어서, 유리한 형상인 180° 나선형(Helical 180°) 초고층건물을 대상으로 풍진동실험을 수행하여 나선형 초고층건물의 공력불안정 진동 특성 및 공력감쇠 특성을 조사하였고, 정방형 초고층 건물의 결과와 비교분석 하였다. 본 연구에서의 공력감쇠율은 RD법(random decrement technique)을 이용하여 평가하였다. RD법에 의해 평가된 공력감쇠율은 기존문헌 및 준정상가정이론 결과와 비교·검증하였다. 실험결과, 공력진동 실험결과 180° 나선형모형의 풍직각방향에 대한 공력불안정 진동은 발생하지 않는 것이 확인되었다. 정방형과 180° 나선형 형상에 대한 공력감쇠율을 살펴보면, X방향에 대한 공력감쇠율은 무차원 풍속이 증가와 비례하여 점진적으로 증가하는 경향이 나타났다. 반면, Y방향에 대한 공력감쇠율은 정방형모형과 매우 다른 양상이 나타나는 것을 알 수 있었다.
        4,000원
        1 2 3 4 5