        61.
        2014.10 서비스 종료(열람 제한)
        An inter-layer noise problem in the apartment has been issued. An fundamental investigation has been carried in this study. An vibration-acoustic interactive analysis, has been selected to see the relationship between concrete slab thickness and its sound level in the apartment. Results showed that the sound pressure level had been decreased when the concrete slab thickness was increased. These results would be helpful to provide an useful information for developing of a high performance floor slab minimizing inter-layer noise.
        62.
        2014.10 서비스 종료(열람 제한)
        Depending on the speed up of railway noise problem has become increasingly serious. In general, under the same conditions when the vehicle speed is 300km/h in a 400km/h increases, it is known that an increase in the noise level of 6 to 7dB. Railway Noise can be reduced by improving the vehicle and the track system. Also, the noise barrier and sound absorbing block may be a valid alternative to reduce railway noise. Here we propose a construction method of absorbing blocks are removable to allow maintenance.
        63.
        2014.07 KCI 등재 서비스 종료(열람 제한)
        합리적인 온도 설계하중을 연구하기 위하여, 실제 크기의 콘크리트 슬래브가 없는 강상형 거더 교량 시험체를 제작하였다. 높이에 따라 부착된 18개의 온도 게이지에서 5개월 동안 온도 데이터를 측정하였다. 강상형 거더 교량 시험체의 상단과 하단 사이의 온도 차가 계산되고, 온도 구배 모형이 확률 방법으로 제안되었다. 본 연구에서 제시된 모형은 유로 코드에 의해 제안 된 모델과 비교했을 때 약 97%의 상관관계를 보인다. 따라서, 본 연구의 결과로 제안 된 온도 구배 모델은 온도 설계 하중 계산시 기초 자료로 활용 될 수 있다.
        65.
        2014.02 서비스 종료(열람 제한)
        본 연구에서는 기존의 교면포장 공법인 아스팔트와 라텍스 개질 콘크리트 포장의 단점을 극복한 교면포장용 고성능 콘크리트의 개발을 위하여 교면포장용 콘크리트 슬래브의 내구성을 평가하였다.교면포장용 고성능 콘크리트의 배합으로는 A-Type (실리카퓸 6%), B-Type (실리카퓸 6%+플라이애쉬 20%), C-Type (실리카퓸 6%+고로슬래그 40%)의 3가지 종류를 고려하였고 현재 교면 포장에 사용되고 있는 라텍스 개질 콘크리트 포장(LMC)과 일반 콘크리트 포장(OPC)에 대하여 비교 평가하였다. 내구성 평가를 위한 실험으로는 정적재하실험과 피로실험을 실시하였으며 처짐 및 균열폭과 콘크리트 및 철근 변형률을 측정하여 비교하였다. 또한 범용 프로그램인 ABAQUS를 이용한 유한요소 해석을 통하여 실험결과를 검증하였다. 실험결과, 정적재하시험의 경우 고성능 콘크리트 배합이 LMC 및 OPC에 비하여 역학적 특성 및 내구성에 있어서 우수한 성능을 보여주었다. 고성능 콘크리트 배합 중에선 A-Type이 처짐 및 균열저항성에 있어서 가장 우수한 것으로 나타났다. 피로시험의 경우에는 고성능 콘크리트 배합이 LMC 및 OPC에 비하여 균열저항성이 우수한 것으로 나타났으나 전체적인 거동은 모든 시험체가 일정하게 유지되어 반복하중에 대하여 충분한 내하력 및 강성을 확보하고 있는 것으로 판단된다. 유한요소 해석 결과, 처짐의 경우 1~4mm, 변형률의 경우 최대 12%의 상대오차를 보여 실험결과와 유사한 변형을 보였다
        66.
        2013.10 서비스 종료(열람 제한)
        In this study, an experimental study to investigate the shear friction behavior of the SC Wall to RC slab connection was carried out. The maximum shear friction capacity and failure mode were examined, and the results were also compared with theoretical value. Finally, the results are to be used for the basic reference of the design guideline(draft) for the RC-SC connection.
        67.
        2013.10 서비스 종료(열람 제한)
        The results from air-coupled impact-echo(IE) tests into concrete slab should be interpreted and represented so that field engineers can effectively check the condition of the structure. To improve these issues, IE data in the form of “4-D spectrum plot” can be utilized to identify the information of concrete defects effectively. The concept of the 4-D plot is introduced, and the effects of image parameters (e.g. frequency range, transparency index) are experimentally investigated in this study.
        68.
        2013.07 KCI 등재 서비스 종료(열람 제한)
        Prestressed concrete (PSC) members are readly available in civil engineering applications due to the convenience of construction and easy of quality control in the manufacturing process of the member. Especially, half-depth precast concrete composite slab, which is one of the PSC flexural members is developed recently using the long-line method. The half-depth precast concrete composite slabs are composed of the precast concrete and the in-situ concrete placed at the site. In this paper, we present the results of experimental investigations pertaining to the pretensioning efficiency and the flexural behavior of half-depth precast concrete composite slab which is made of precast PSC manufactured by the long-line method. In the long-line method, the pretensioned precast member is manufactured simultaneously, by tensioning tendons at once. In addition, we suggest the equation that can estimate the flexural strength of half-depth precast concrete composite slab reasonably by considering the effects of rebar embedded in the precast PSC flexural member.
        69.
        2013.04 서비스 종료(열람 제한)
        Numerical scheme of predicting large deflection of RC column structures is discussed by developing the algorithm of equivalent lateral loading system based on theorem of virtual work.
        70.
        2013.04 서비스 종료(열람 제한)
        In this study, we aimed to consider the inspection without destroying the specimen using the Impact Echo Method of nondestructive test using stress wave in an objective manner for detecting defects in concrete members. As a result of estimating the thickness of the concrete slab member using Impact Echo Method under the influence of the result of the stress wave, the average error in the 7.49% confirmed the applicability. In addition, we can check the possibility of data acquisition and construction of concrete structures for the construction of the diagnosis system
        71.
        2013.04 서비스 종료(열람 제한)
        In this study, I tried to derive the expression intensity estimation through analyzing the correlation between wave velocity and compressive strength of high-strength concrete and normal-strength one, using ultrasonic pulse velocity which is one of the non-destructive tests which do not damage the structure. By producing a material age strength and body separate experiment which is applied to the ultrasonic pulse velocity, we have derived the estimating compressive strength such as a formula strength of normal-strength concrete : Fc=0.0841vp3.6018, R2=0.82 high strength concrete : Fc=0.0008vp6.9287, R2=0.88. As a result of this verification experiment, the estimated error rate of the compressive strength of normal strength concrete is 16.32%, in the case of high-strength concrete is now 7.58 percent.
        72.
        2012.11 서비스 종료(열람 제한)
        In this study, experimental research was carried out to study the structural performance of slab-column joints designed by the application of reducing of joint regions damage using steel fiber reinforced concrete. Test results showed that specimens(RCFPS series) were increased the maximum load-carrying capacity by 1.12~1.23 times and showed stable hysteresis behavior in comparison with the standard specimen(SRCFP).
        73.
        2012.05 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 철근콘크리트 슬래브의 내부식성과 경량화를 도모하기 위하여 GFRP bar를 휨보강근으로 사용하는 경량골재콘크리트 슬래브를 고려하고 이 구조물에 대하여 기초적인 거동을 조사하였다. 경량콘크리트의 압축강도 및 인장강도 그리고 콘크리트 파괴에너지 측정, 일련의 슬래브 휨실험, 비선형유한요소해석을 통한 수치해석, 휨실험과 수치해석의 결과비교 등이 행하여졌다. 그 결과, GFRP bar를 휨보강근으로 사용한 경량콘크리트 슬래브는 기준시험체로 사용된 동일 규격의 철근콘크리트 슬래브에 비하여 무게를 28%정도 감소시킬 수 있었지만 파괴하중은 36%정도 감소되었다. 이는 GFRP bar의 낮은 축강성과 경량콘크리트의 낮은 부착강도 때문인 것으로 판단된다. 그리고 경량콘크리트의 부착력 감소 특성을 고려하기 위하여 GFRP bar와 콘크리트 경계면 사이에 계면요소를 사용한 수치해석 결과는 계면요소의 사용이 실험결과에 더 근접해갈 수 있는 방법임을 보여주었다.
        74.
        2011.11 KCI 등재 서비스 종료(열람 제한)
        본 연구는 PC와 RC부분이 만나는 접합면에 대한 구조적 거동과 수평 전단강도 평가를 위한 실험적 연구이다. 접합면에서의 수평전단 내력은 접합면의 거칠기나 전단보강근 유무에 따라 결정되어진다. 본 연구에서는 전단 보강근의 형상이 루프형과 래티스형로 구분하고, 보강근 간격 등에 따라 총 4개의 수평전단강도 실험체를 제작하여 실험을 수행하였다. 실험결과, 접합면에서 수평전단 강도는 수직방향 변형에 의해 지배됨을 알 수 있었다. 보강근 형상에 따른 비교 결과, 루프형의 실험체가 평균 초기균열하중, 평균 최대하중 및 접합면의 평균 초기강성 측면에서 각각 33.7%, 45.9%와 55.2%정도 큰 것으로 나타났다. 현행의 국내 전단강도 평가식과 비교한 결과, 루프형 전단보강 실험체는 2.32∼4.23배, 래티스형 전단보강 실험체는 1.65∼3.06배 상회하는 것으로 나타났다. 따라서 접합면의 거동이나 구조설계기준에 의한 내력이 안전측으로 평가되어 현장에 적용하는 데에는 별다른 문제는 없는 것으로 판단된다.
        75.
        2010.01 KCI 등재 서비스 종료(열람 제한)
        본 연구는 지하주차장 건물의 바닥구조를 구성하기 위한 방안으로서 프리스트레스를 도입한 일방향 장선구조인 MRS공법을 제안하고, MRS공법의 연속단 접합부에 대한 구조실험을 수행함으로써 휨거동 특성과 접합상세의 적정성을 평가하였다. 연속단 접합부는 4개의 실험체를 제작하였으며, 연속단 접합부에 부모멘트가 작용하도록 실험을 수행하였다. 실물크기로 제작한 MRS 연속단 접합부는 접합부의 구조상세와 상관없이 충분한 휨강성의 발현과 함께 연성적인 휨파괴 거동을 보여주었다. 특히 지붕층에 위치한 MRS 연속단 접합부는 큰 값의 부모멘트를 저항하기 위한 인장철근의 양을 최대철근비 이하로 설계할 수 있으며, 최종파괴 모드는 휨에 의해 지배되는 거동특성을 보여주었다. 따라서 제안된 MRS공법은 우수한 지압성능과 연속단 구축이 용이한 접합부 상세를 갖는 것으로 평가되었다.
        76.
        2009.03 KCI 등재 서비스 종료(열람 제한)
        하프PC 슬래브는 시공중에 슬래브 판에 균열이 발생하기 쉽고 이러한 균열들을 보수보강 하지 않은 상태에서 덧침콘크리트를 타설할 경우 합성슬래브의 내력에 영향을 미칠 것으로 사료된다. 하지만 하프PC 슬래브에 발생한 균열이 합성슬래브의 구조성능에 미치는 영향에 관한 연구는 아직까지 없는 실정이다. 따라서 본 연구에서는 하프PC 슬래브에 발생한 균열이 합성 슬래브의 내력에 미치는 영향을 조사하기 위하여 덧침콘크리트를 타설하기 전에 하프PC 슬래브에 균열을 발생시킨 시험체와 균열이 없는 합성슬래브 시험체를 제작하여 슬래브의 휨 성능을 검토하였다.
        77.
        2008.11 KCI 등재 서비스 종료(열람 제한)
        본 연구에서 검토된 슬래브는 트러스 철근이 설치된 하프 프리캐스트 콘크리트(PC) 슬래브로서, 이러한 슬래브의 내력평가에 대한 몇몇 연구결과가 소개되었다. 하지만 합성슬래브의 내력평가에 대한 연구가 대부분이고 하프PC슬래브의 내력평가에 대한 연구는 적으며 특히, 트러스 높이에 따른 슬래브의 구조성능에 관한 연구는 매우 부족한 실정이다. 따라서 본 연구에서는, 트러스 철근이 설치된 하프PC슬래브의 구조성능을 검토하기 위하여 트러스 철근의 높이가 다른 세 종류의 슬래브를 제작하여 휨 실험을 실시하였다.
        78.
        2008.05 KCI 등재 서비스 종료(열람 제한)
        최근 구조물이 노후화되면서 기존 구조물과 시공품질을 관리하는 비파괴검사 평가의 요구가 증가되고 있다. 콘크리트 구조물의 압축강도 추정의 중요성이 건설업계에서 또한 점차적으로 증대되고 있는 실정이고, 시공관리와 품질관리에 있어서 중요한 요소이다. 본 연구는 콘크리트의 압축강도를 비교하기 위한 비파괴 검사법 중 슈미트해머 시험과 충격반향기법을 이용하여 수행되었다. 콘크리트 압축강도와 슈미트해머에 의한 반발경도 값과 충격반향기법 실험결과와의 관계를 알아내는데 초점을 두었으며, 콘크리트의 압축강도와 반발경도 값은 밀접한 관계가 있음을 알 수 있었다.
        79.
        2008.03 KCI 등재 서비스 종료(열람 제한)
        본 논문은 콘크리트 슬래브교량의 반복적인 설계과정을 신속히 처리함과 동시에 모든 성과물을 작성함에 있어 웹을 기반으로 한 설계자동화 시스템 개발을 위한 것이다. 웹 기반 구조도면 처리기법은 웹기반 설계자 동화시스템 핵심 기술 중 하나이다. Active Server pages(ASP)는 설계 요소를 유용하게 활용하며 이를 데이터베이스에 저장하게 된다. eXtensible Markup Language(XML)과 XML기반 벡터그래픽은 구조 도면을 웹 화면으로 효과적으로 신속히 구현할 수 있다. 본 논문에서는 XML과 Scalable Vector Graphics(SVG)를 활용하여 웹 화면에 구조도면 및 설계 성과품을 작성하였다. 구조도면 작성 시 핵심 도면작성 요소기술로서 개발된 XML Data Island는 웹 기반 구조도면 작성 시 매우 효과적임을 증명하였다.
        80.
        2008.03 KCI 등재 서비스 종료(열람 제한)
        기 시행된 관련 보고서에 의하면 외관 상태에 대한 육안 점검은 구조적 안전성 평가를 위해 대단히 중요한 부분이다. 본 연구는 개별 손상유형의 분리 평가에 의한 콘크리트 바닥판에 대하여 개선된 상태평가 방법을 제안한다. 먼저, 한데 묶여서 다루어졌던 여러 유형의 손상들을 분리하고, 다음으로 현행 지침을 토대로 가중점수를 부여하였다. 그 밖의 전반적인 과정은 혼란을 피하기 위하여 가능한 한 그대로 유지하였다. 제안된 방법을 4개의 교량에 대해 기 수행된 진단프로젝트에 적용, 시험 결과는 본 방법이 실무에서 드러난 현행 지침의 논점을 보완할 수 있다는 점에서 합리성과 적용성을 보여준다. 상세 분할 및 가중평가에 근거한 합리적인 시스템 평가와 함께 과도 손상 부재의 특별 관리로 이원화함으로써 보수·보강에 대한 적정성과 경제성을 부여하고 안전성을 확보할 수 있다. 본 연구의 이원화된 평가방법은 가치공학의 적용 영역을 유지관리 단계로 확장한다.