검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 817

        81.
        2020.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to design a diesel engine system and predict its performance, it is necessary to analyze the gas flow of the intake and exhaust system. A gas flow analysis in three-dimensional (3D) format needs a high-resolution workstation and enormous time for analysis. Therefore, the method of characteristics (MOC) was used for a gas flow analysis with a fast calculation time and a low-resolution workstation. An experiment was conducted on a single cylinder diesel engine to measure pressure in cylinder, intake pipe and exhaust pipe. The one-dimensional (1D) gas flow was analyzed under the same conditions as the experiment. The engine speed, valve timing and compression ratio were the same conditions and the intake pressure was inputted as the experimental results. Bent pipe such as an exhaust port that cannot be realized in 1D was omitted. As results of validation, the cylinder pressure showed accuracy, but the exhaust pipe pressure exhibited inaccuracy. This is considered as an error caused by the failure to implement a bent pipe such as an exhaust port. When analyzed in 3D, calculation time required 61 hours more based on a model of this study. In the future, we intend to implement a bent pipe that cannot be realized in 1D using 3D and prepare a method to supplement reliability by using 1D-3D coupling.
        4,000원
        86.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the flow by impingement at water dust collector with movable nozzle was analyzed by computational fluid technique. The velocity and vorticity of the dust collector were compared by positioning the nozzle to up and down. Also, the mean velocity were compared through three specific locations that were the diffuser inlet, movable nozzle surface and dust collector outlet. It can be checked that the vorticity and velocity magnitude are verified by the fluid solver of Fluent. As the result of this study, the movable nozzle located at 4cm down from initial position of the nozzle shows the great characteristics of vorticity and velocity distribution for dust collection.
        4,000원
        87.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Various electronic control parts and devices installed in electric vehicles have greatly improved the convenience of occupants, but electromagnetic waves emitted from electronic devices have greatly increased concerns about malfunctions, deterioration of performance, safety accidents, etc. There are two models of analysis. Case A is symmetrical about one axis of rotation. Case B has two axes of rotation. In this study, a flow analysis was conducted to find excellent flow conditions in the mixing process to develop a paint with excellent electromagnetic shielding and thermal insulation performance. The results of the flow analysis are reflected in manufacturing specifications and are intended to be used to develop high-quality systems.
        4,000원
        88.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 건물, 교량 및 해양구조물에 많이 적용되는 기본적인 형상인 벽면에 부착되어 있는 사각실린더 주변의 유동에 대해, 3개의 난류모델(v2-f 모델, k-ω 모델, k-ε 모델)을 적용하여 URANS 수치해석을 각각 수행하고, 그 결과를 비교하였다. 이 유동 은 물체의 모서리에서 발생하는 칼만와(karman vortex) 때문에 본질적으로 강한 비정상성을 가지고 있으며, 물체의 후류 영역에서도 매우 복잡한 유동구조를 가지고 있다고 알려져 있다. 3개의 난류모델이 적용된 수치해석으로부터 예측되는 평균 유동장과 지배적인 유동 의 주파수를 Wang et al.(2004; 2006)의 실험결과와 비교하였다. 비교 결과, v2-f 모델이 적용된 URANS 결과가 실험결과와 가장 유사한 결과를 보여주었고, k-ω 모델도 우수한 결과를 보인 반면, k-ε 모델은 본 대상 유동에 적용하기에 부족함을 확인하였다. 따라서 강한 박리가 존재하는 유동의 해석 시에는 v2-f 모델은 좋은 선택이다. 그리고 유동의 박리 제어를 위한 연구에 활용될 것으로 기대된다.
        4,000원
        89.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The level at which analyses of DNA content might contribute more significantly to the genetic mechanisms of evolution lies in the events of speciation. The object of this study was to investigate the DNA content of abalone (Haliotis discus hannai) and determine the optimal tissue samples for measuring the DNA content of abalone by flowcytometry without fixation. The DNA content (pg/nucleus) of gill tissue (2.5±0.08), which was contaminated with protozoa, was significantly lower than that of muscle tissue (3.2±0.02), mantle tissue (3.2±0.02) (p<0.05), and a standard reference standard, while the DNA contents of muscle tissue and mantle tissue were higher than that of the standard reference. Considering the results of this study, DNA content analysis with flowcytometry is an acute and rapid method by which muscle tissue and mantle tissue are the most appropriate sample for measuring the DNA content of abalone without fixation.
        4,000원
        90.
        2020.06 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        국내 중·저준위 방사성폐기물 처분시설로 고려되고 있는 표층처분시설의 불포화대에서 핵종 이동을 야기하는 지하수 유동을 평가하기 위하여 유한요소법 기반의 COMSOL Multiphysics을 이용한 수치모델을 개발하였다. 그리고, 처분장 가장자리 를 대상으로 처분고, 뒤채움재, 처분덮개로 구성되는 표층처분시설과 그 아래에 위치한 불포화대를 포함한 수직 2차원의 모델 영역을 구성하여, 시나리오 별 모델링을 수행하였다. 지속적 강수 유입 조건과 간헐적 강수 유입 조건 비교에서 포화도의 파동 현상을 제외하고는 뚜렷한 차이점을 보이지 않는 것으로 판단되었다. 불포화대의 공극률이나 잔류함수비와 같은 입력 자료는 전반적으로 불포화대 지하수 유동에 큰 영향도가 없는 것으로 판단되었다. 하지만, 불포화대의 수리전도도는 지하수 유동에 큰 영향을 미치는 것으로 판단되었다. 즉, 처분고로의 지하수 유입 속도를 판단하기 위해서는 불포화대의 수리전도도 특성이 신중하게 고려되어야 할 것으로 판단되었다.
        4,500원
        93.
        2020.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, two types of cyclone separators containing a structure of prevention underflow and a cyclone separator without the structure were analyzed by computational fluid technique. The pressure loss was increased by increasing the inlet velocity from 8m/s to 28m/s, and the velocity and pressure were compared through five cross sections in the vortex finder. Also, the velocity and the pressure contour in the central section were compared. It can be seen that the performance reduction of the cyclone separator by the prevention structure is related to the distance to the vortex finder inlet rather than the effect of the diameter of the structure.
        4,000원
        94.
        2020.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study is carried out to analyze the velocity distribution for each location and the uniformity index according to straight distance on exit side by changing the design factors of branch pipe connected to 180° circular mixing-tee using RSM(Reynolds Stress Model) turbulence model. As the results of the flow characteristics according to hydraulic diameter, the velocity profiles in the 90° sectional area are generally similar. In the 180° section, the maximum velocity point shows Y/D=0.7~0.8 after rapid increase of the flow velocity. In the result according to the distance away from inlet, the maximum velocity point in the 90° sectional area is located in outer side of the curved pipe as the distance away from inlet increases. In the 180° sectional area, the maximum velocity point is showed in Y/D=0.7~0.8 after the rapid increase of the flow velocity regardless of the variation of branched distance. In case of inclined angle, the maximum velocity point in the 90° sectional area is located in outer side of the curved pipe as the inclined angle increases. In the 180° sectional area, the maximum velocity point is observed in Y/D=0.8 regardless of the inclined angle. In addition, the uniformity index of flow velocity shows that it is stabilizing after approximately L/D=40 away from the end of the curved pipe regardless of the flow factors in the branch pipe.
        4,000원
        95.
        2020.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, numerical analysis was carried out to develop low-noise axial fans, which are often used for ventilation in houses. A commercial program and the turbulence models are used for the analysis of internal fan. Proudman acoustic power model and the Curle surface acoustic power model were used for analysis. As a result, the distribution of flow velocity and pressure around the blade and guide of the fan was high, and low in the center of the fan. Noise from the inner wall of the fan case and the blade surface was the highest at the body and vane connections of the blade, and low at the center of the vane and the center of the body.
        4,000원
        96.
        2020.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 흑삼과 흑마늘을 이용하여 블랙잼을 제조하면서 물성의 변화를 모니터링 해 보았다. 블랙잼의 배합 조건은 흑삼(X1, 30-54 g), 흑마늘(X2, 75-135 g), 펙틴 4.5 g, 사과페이스트 270 g 및 프 럭토올리고당 360 g이며, 반응 변수로는 탄력성, 응집성, 씹힘성, 깨짐성 및 부착성으로 반응표면분석을 실시하였다. 탄력성, 응집성, 씹힘성, 깨짐성 및 부착성에 대한 회귀식의 R2는 각각 0.8948, 0.9103, 0.9032, 0.9097, 0.8561로 5∼10%의 유의수준에서 유의성이 인정되었다. 블랙잼의 탄력성이 가장 높은 흑삼 및 흑마늘 배합조건과 그 탄력성은 흑삼 함량 54.00 g 및 105.83 g에서 194.39%로 나타났으며, 탄 력성이 가장 낮은 흑삼 및 흑마늘 배합조건과 그 탄력성은 흑삼 함량 31.48 g 및 119.43 g에서 164.11% 로 나타났다. 블랙잼의 응집성이 가장 높은 흑삼 및 흑마늘 배합조건과 그 응집성은 흑삼 함량 48.85 g 및 129.62 g에서 40.96%로 나타났다, 응집성이 가장 낮은 흑삼 및 흑마늘 배합조건과 그 응집성은 흑삼 함량 50.06 g 및 82.77 g에서 32.96%로 나타났다. 블랙잼의 씹힘성이 가장 높은 흑삼 및 흑마늘 배합조건과 그 씹힘성은 흑삼 함량 42.95 g 및 106.83 g에서 43.19 g로 나타났다. 블랙잼의 깨짐성이 가장 높은 흑삼 및 흑마늘 배합조건과 그 깨짐성은 흑삼 함량 32.10 g 및 88.04 g에서 16,874 g로 나타났으며, 깨짐성이 가 장 낮은 흑삼 및 흑마늘 배합조건과 그 깨짐성은 흑삼 함량 50.53 g 및 83.91 g에서 678 g로 나타났다. 블랙잼의 부착성이 가장 높은 흑삼 및 흑마늘 배합조건과 그 부착성은 흑삼 함량 32.91 g 및 124.60 g에 서 14.06 g로 나타났다. 이상의 결과로부터 흑삼과 흑마늘의 배합비와 블랙잼의 물성의 관계를 조사함으 로서 건강기능성 소재를 이용하여 누구나 즐겨 먹을 수 있는 블랙잼을 제조할 수 있을 것으로 여겨진다.
        4,000원
        97.
        2020.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The flow analysis of two dimensional transient flow over the obstacles with rectangular cross sections was performed. And 190 velocity distributions for each aspect ratio were imaged to provide input data for convolutional neural network learning. The classification and regression methods were used in estimating the aspect ratio from given velocity distributions. As a result the classification method was more exact than the regression method. But both the classification and regression methods gave relatively accurate prediction of the defined aspect ratio judging from the imaged velocity distributions. This confirms that the deep learning technique is applicable to the flow analysis.
        4,000원
        98.
        2020.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        겨울철 벤로형 유리온실(W59×L68×H5.9m) 보온스크린 높이의 차이에 따른 실내온도 변화를 파악하기 위하여 00시부터 04시까지 30분 간격으로 열유동해석을 하였다. 초기에는 상대적으로 난방 외부접촉면적이 큰 보온스크린 설치높이 5.9m에서 보온스크린 설치높이 4.1m에 비해 온도감소가 빨라 낮은 온도를 나타냈으나 해석 2시간 이후부터는 상대적으로 온도감소가 느렸고 04시에는 0.6°C 높았다. 그러나 해석시작 1시간 후 실내온도가 약 13°C까지 내려가고, 그 이전에 난방기가 작동해야 된다고 볼 때, 해석 2시간 동안 온도감소가 상대적으로 느렸던 보온스크린 설치높이 4.1m에서 5.1m에 비해 난방에너지 절감에 유리할 것으로 판단되었다. 토마토가 자라는 지면 2m 높이에서의 유동은 보온스크린 설치높이 5.9m에서 4.1m에 비해 상대적으로 넓고 빨랐으며 유동해석 1시간 후인 01시의 평균차이는 0.034m·s-1였다. 여름철 차광스크린 설치높이를 5.7m와 3.9m로 달리하되 70%닫힘 조건에서 12시부터 13시까지는 온실하부덕트 외부 공기유입량 0.67m3·s-1 상태 그 후부터는 외부 유입공기를 3배로 증가하여 냉방효과를 비교하였다. 초기 12시부터 13시까지는 차광스크린 70%닫힘 상태에서 무차광에 비해 오히려 평균 약 0.9°C 높았지만 외부공기유입량이 증가하는 13시 이후 부터는 차광스크린 70%닫힘 조건에서 온도가 감소하였고 14시 30분에는 무차광에 비해 0.5°C 낮았다. 차광스크린 70% 닫힘 조건에서 바닥면의 온도분포는 스크린 설치높이와 개방 정도에 비례하여 낮았으며 무차광에 비해 8°C이상 낮았다. 온실 내 상대습도는 차광스크린을 30% 개방하는 조건에서는 차광스크린의 높이나 개방정도에 따른 차이가 미미하였다.
        4,000원
        99.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the uniformity of the horizontal velocity and the temperature of each zone were investigated by computerized analysis method to divide the drying room into three multi - rooms to ensure the uniformity of flow inside the forced convection hot air dryer. The internal structure of the drying room of the dryer was modeled using Solidworks. In order to control the flow of hot air circulating in the drying chamber, the possibility of controlling the horizontal flow inside the drying room was verified by using a perforated plate, a guide vane, and a vertical plate. From the results of the flow visualization in the drying room, it was understood that the internal flows of the dryer models 1, 2 and 3 change from ununiform flow to uniform flow. From the analysis of velocity and temperature fluctuation, the results of the analysis of the dryer model 3 satisfied the design conditions.
        4,000원
        100.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        When oil spill disaster on sea takes place, the most effective measure is to use oil fence with vertical wall. It has been big challenges that suitable oil fence in consideration of variety of variables such as wind speed, height of wave and current direction is chosen. And current characteristics below two of vertical wall was studied by PIV experiment with utilizing technic of visualized analysis like velocity distribution, contour of velocity and streamline pattern in flow characteristic between vertical wall of oil fence. In this study it is purposed to identify characteristics of inside water flow between two vertical walls depending on respective various water speeds to minimize outflow of floating article below bottom of vertical wall and observed that re-circulation flow and irregular vortex at certain places between two vertical walls occurred. Consequently, the study showed that failure of oil fence such as entrainment failure and submergence failure can be largely lessen by means of optimizing length between two vertical walls with water speeds.
        4,000원
        1 2 3 4 5