검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 274

        83.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        When developing a product, ensuring the quality and reliability is essential. Reliability process is always underestimated compared to its importance, especially in the field of domestic medical devices. In this paper, reliability process developed for near-infrared solid microscope, based on a variety of existing practices and other product process. The following findings were obtained as research progressed. First, learning about the medical equipment needed to assure the quality and reliability standards. Second, reliability process established to design a product in the field of medical devices
        4,000원
        84.
        2013.03 구독 인증기관 무료, 개인회원 유료
        근적외선 흡수 물질은 근적외선 이미징에 사용가능한 물질이며 최근에는 바이오 이미징, 유기태양전지 효율 향상을 목적으로 활용 범위가 확장되고 있다. 근적외선 흡수 물질은 π-conjugation system을 가지고 있으며 전자가 비편재화 되어 밴드갭이 작을수록 장가장 빛을 흡수한다. 주요 물질군으로는 유기 단분자 물질인 Polymethine, Phthalocyanine, Porphyrin 계 물질과 고분자인 Poly(thiophene), Poly(selenophene) 이 있으며, 유기 단분자 소재는 용매에 잘 녹으며 흡수 밴드가 Sharp 하고 고분자 소재는 용매에 잘 녹지 않으며 흡수 밴드가 Broad 한 특징이 있다. 최근 근적외선 응용 관련 분야의 대표적인 선도 연구로는 세포 이미징, 세포치료, 유기태양전지가 있다.
        4,000원
        85.
        2013.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 현미의 취반적성 및 관능성 개선을 위하여 적외선 가열처리 및 수침의 영향을 검토하였다. 현미는 적외선 가열처리 조건에 따라 부분적인 갈변화와 함께 외피 및 배유에 균열이 발생하여, 취반 후 곡립 형태가 파손되고 식미가 저하되었다. 현미의 균열 손상은 120oC 이상의 온도에서 초기수분함량이 3% 이상 감소할 때까지 가열하는 조건에서 발생하였으나, 수침과 병행하여 가열하는 경우에는 현미의 균열 및 형태 손상이 발생하지 않았다. 현미는 적외선 가열에 의해 부분 호화가 발생하며, 호화도는 수침 처리한 현미에서 더 높은 것으로 확인되었다. 현미는 적외선 가열 처리에 의해 취반 질감이 연화되었으며, 수침과 병행하는 경우 가장 높은 연화효과를 나타내었다. 취반 현미의 관능성은 적외선 가열 처리에 의해 크게 개선되었으며, 수침을 병행하였을 때 전체적인 기호도가 가장 높은 확인되었다. 상기 결과를 통하여 수침 처리하지 않은 현미의 경우 120oC에서 수분함량이 1% 감소까지, 수침시료의 경우 20분간 상온수침 후 110oC에서 수분 함량 14%까지의 가열조건을 현미의 취반성과 관능성 개선을 위한 최적조건으로 설정하였다.
        4,000원
        86.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The SPICA (SPace Infrared Telescope for Cosmology & Astrophysics) project is a next-generation infrared space telescope optimized for mid- and far-infrared observation with a cryogenically cooled 3m-class telescope. It will achieve the high resolution as well as the unprecedented sensitivity from mid to far-infrared range. The FPC (Focal Plane Camera) proposed by KASI as an international collaboration is a near-infrared instrument. The FPC-S and FPC-G are responsible for the scientific observation in the near-infrared and the fine guiding, respectively. The FPC-G will significantly reduce pointing error down to below 0.075 arcsec through the observation of guiding stars in the focal plane. We analyzed the pointing requirement from the focal plane instruments as well as the error factors affecting the pointing stability. We also obtained the expected performance in operation modes. We concluded that the FPC-G can achieve the pointing stability below 0.075 arcsec which is the requirement from the focal plane instruments.
        4,000원
        87.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Appliances are connected with home network and intellectualization is being rapidly processed. As ubiquitous home is visualized, home sensor is intellectualized and developed with wearable form for the possible inter-home sensor information exchange. Based on the RFID and ubiquitous ID, the home sensors are expected to be developed for the diverse information. The sensor techniques has been intellectualized and diversified by expecting to be developed into perception sensor, extreme environment sensor, micro mechanical sensor, and biosensor. In this paper, the control algorithm of digital control system applicable to the real appliance is suggested. Infrared ray module of appliance is used with the purpose in supporting home network to the appliance in use. And the wireless sign transmitted from home server is transformed into infrared rays sign.
        4,000원
        88.
        2012.10 구독 인증기관 무료, 개인회원 유료
        Ensure the quality and reliability of the developing product should be considered essential. Reliability process is lacking compared to its importance, especially in the field of domestic medical devices. In this paper is Reliability process formulation ofnear-infrared solid microscope for ophthalmic surgery, based on a variety of existing practices and other product process to ensure product reliability, reliability process was established.Together domestic and international standards were investigated that essential in order to maintain a high level of reliability and quality. In this paper, the following findings were obtained. First, learned about the medical equipment needed to ensure quality and reliability standards. Second, reliability ensure process design and formulation were studied.
        4,000원
        89.
        2012.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        During the laser-assited endoscopic surgery, the laser light is delivered to the deep tissue or the internal organ using a light transmitting delivery system. It is necessary to modify the direction of the light emission at the distal end of fiber tip for some application of in laser-assisted surgery. The homemade diffusing fiber and the forward firing fiber are used for the endoscopic delivery system of the continuous IR laser into the water rich tissue. The beam emission and the laser-assisted ablation and coagulation pattern were compared for two distinctive fiber systems. The diffusing fiber produced cavity and coagulation zone more or less a circular shape, while the forward fiber produced an elongated cavity and coagulation region. The diffusing fiber produced wider and shorter coagulation and cavity zone compared to that of forward-firing fiber
        4,000원
        90.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this work was to study the effect of far infrared ray-vacuum drying having reflection and dispersion functions(RD-FRVD) and hot air drying(HAD) on the quality changes of dried vegetable flakes. HAD was regarded as a control. Browning degrees, color value, titratable acidity and pH value were measured as chemical evaluations. Rehydration and electron micrographs were investigated as physical evaluation. Microbial cells were counted. The color value and browning degrees were increased in both RD-FRVE and HAD. In case of degree of those changes, RD-FRVD made less changes than HAD. Especially, green bean sprout had no differences in color value and browning degrees between raw material and dried-rehydrated material. There were no significance differences in titratable acidity and pH value between raw material and dried-rehydrated material. The total microbial counts were gradually reduced in RD-FRVD. The rehydration rates of dried vegetable flakes were typically increased in RD-FRVD. Also, these results were investigated electron micrographs evaluation. Therefore, these results showed that the quality of dried-rehydrated vegetable flakes was typically enhanced by using RD-FRVD.
        4,000원
        91.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 근적외선분광법의 현장 이용성 및 이탈리안 라이그라스 원물 사일리지의 신속한품질평가를 위한 근적외선 검량식을 개발하기 위하여 전국에서 이탈리안 라이그라스 사일리지 약 450여 점을 수집하였다. 각각의 시료는근적외선 분광기를 이용하여 스펙트럼을 측정한 후 측정된 스펙트럼과 실험실 분석값 간에상관관계를 이용한 다변량회귀분석법을 통하여검량식을 유도한 다음 각 성분별로 예측 정확성을 평가하였다. 이탈리안 라이그라스 원물사일리지의 수분 함량에 대한 검량식 개발 결과는 검량식 작성시 표준오차(SEC)가 0.94%(R2=0.99)로 매우 우수한 정확성을 보였으며 개발된 검량식의 상호검증(SECV) 결과는 1.27%(R2=0.98)로 나타났다. ADF, NDF 및 조단백질함량 평가를 위해 개발된 검량식의 상호검증(SECV) 결과는 각각 1.26% (R2=0.88), 2.0%(R2=0.84) 및 0.96% (R2=0.93)으로 나타났으며조회분함량 평가에 대한 검량식 개발 결과는다소 낮은 정확성(SECV 0.72%, R2=0.62)을 나타내었다. 사일리지의 발효품질의 주요 평가항목인 pH와 젖산함량 평가에 대한 검량식 개발결과(SEC)는 각각 0.41 (R2=0.85), 0.18% (R2=0.92)로 나타났으며 개발된 검량식의 상호검증결과(SECV)는 각각 0.56 (R2=0.78), 0.31%(0.81)로 나타났다.
        4,000원
        92.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목적: Al2O3 기판위에 Ge/ZnS 다층박막을 이용하여 중심파장 3450nm에서 반치폭이 약 150nm이고 투과율이 약 95%인 중 적외선 투과필터를 제작하고, 이 필터의 박막 특성을 연구하였다. 방법: 설계에 있어 기판의 한 면은 장파장 투과 필터로,다른 면은 단파장 투과 필터로 코팅한 후 한개의 기판을 중심으로 전면에는 장파장 투과 필터를 후면에는 단파장 투과 필터를 합성하여 중적외선 대역투과 필터를 설계하였다.또한 전자빔 증착장비를 이용하여Ge/ZnS 다층박막 중적외선 대역 투과 필터를 제작한 후, FTIR을 이용하여 투과율을 측정하였고, XRD 데이타로부터 박막의 구조를 분석하였으며, XPS분석으로부터 박막 성분을 확인하였다. 결과: 장파장 투과 필터는 기준파장 2700nm에서 [air/0.490H 0.904L 0.952H 1.086L 1.747H 0.489L (HL)9 H 0.350L 1.616H/Al2O3 substrate]와 같이 설계되었으며, 이때 고굴절률(H)과 저굴절률(L) 물질은 각각 Ge과 ZnS이였다. 또한 단파장 투과필터는 기준파장 4200nm에서 [air/1.261H (LH)7 0.921L 1.306H/Al2O3 substrate]와 같이 설계되었으며, 고굴절률 물질과 저굴절률 물질은 장파장 투과필터와 동일하였다. 설계를 바탕으로 제작한 적외선 투과 필터의 최대파장피크가 제작조건의 변화에 의거하여 이론치에 비해 약 30nm 오른쪽 이동되어 있는 것을 확인하였다. 제작된 필터의 ZnS층이 cubic (111) 결정구조를 가지고 있는 것을 XRD분석으로 확인하였으며, XPS분석에 의해 Ge층이 맨 위층이며 ZnS층과 교번인 다층막으로 형성돼 있다는 것을 확인할 수 있었다. 결론: Al2O3 기판위에 Ge와 ZnS를 교번으로, 한 면은 27층의 장파장 투과필터로 구성되고, 다른 면은 17층의 단파장 투과 필터의 다층박막을 제작하여, 3450nm 중심파장에서 150nm 반치폭을 갖으며 투과율은 약 95%인 중적외선 대역 투과 필터를 제작하였다.
        4,000원
        96.
        2011.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 최근 조사료의 신속한 품질평가 방법으로 근적외선 분광법의 이용성이 확대되고 있는 시점에 근적외선 분광기의 현장 적용성을 평가하기 위하여 수행되었다. 실험실용 근적외선분광기와 소형 근적외선분광기의 조사료 품질평가의 예측 정확성을 평가하기 위하여 전남지역에서 이탈리안 라이그라스 사일리지 67점을 수집하여 각각의 근적외선 분광기를 이용하여 스펙트럼을 측정한 후 사료가치의 실험실 분석값과 다변량회귀분석을 통하여 검량식을 유도하여 예측 정확성을 평가하
        4,000원
        97.
        2011.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 춘파용 사초의 사료가치를 신속하고 정확하게 측정할 수 있는 습식분석의 대안을 모색하기 위하여 수행하였다. 근적외선분광 분석법을 이용한 사초의 분석 가능성을 타진하기 위해 2009년에 생산된 사초 175점을 시료로 사용하였다. 시료는 이탈리안 라이그라스와 보리, 그리고 완두를 혼파한 것으로 NIR System으로 400~2,400nm 사이의 파장을 얻었다. 그리고 수분, 조단백질, 조회분, NDF, ADF를 분석한 다음, 파장과 습식분석치를 이
        4,000원
        99.
        2011.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 IRAS 07280-1829 적외선원과 이를 둘러싸고 있는 분자운에 대해 수행된 12CO와 13CO 1-0 분자선 관측결과와 기존의 적외선 자료를 이용하여 이 적외선원의 생성환경에 관해 연구하였다. 관측자료로부터 얻어진 적외선원의 파장별 에너지분포의 기울기(α=1.16)와 복사온도(145 K), 그리고 광도(∼2.9×104L◉)는 이 적외선 천체가 CLASS I형의 중량급원시성임을 의미한다. 이 적외선원방향에서 관측된 두 CO 분자선에서 보이는 넓은 속도 성분은 분자분출류의 존재를 암시한다. 적외선원을 감싸고 있으리라 짐작되는 분자운A에서 측정된 여기온도는 9-22 K, 질량은 약 ~180 M◉인 것으로 보아 이 분자운이 전형적인 적외선 암흑분자운(Infrared-dark clouds)의 물리적 특성을 가짐을 보았다. 이 분자운의 질량은 비리알 질량보다 10배 이상 작은 값으로 계산되었는데 이것은 여기에 어린 원시성이 이미 생성되고 있다는 관측사실에 모순된다. 이는 아마도 분자운A가 교란운동(turbulence) 혹은 강한 자기장에 의해 지배되는 환경 가운데에 중량급원시성 IRAS 07280-1829을 생성하고 있음을 의미하는 것 일수도 있는 것으로 해석하였다.
        4,000원
        1 2 3 4 5