검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 211

        162.
        1995.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Dry rehydratable film (Petrifilm) method was compared with the standard pate count (SPC) method for estimation of total bacteria in ginseng products. Ginseng products (7 sample) was analyzed for total count by the SPC, and Petrifilm methods, respectively. In the case of ginseng tea, ginseng extract, ginseng extract pill, ginseng powder capsule, and ginseng extract tea,. they showed non-significant values at the 1 level. However, the values of ginseng powder and tablet showed significant at the 1 level. These results generally indicate the suitability of the dry rehydratable film methods as alternatives to the SPC method for estimating of total bacteria in ginseng product samples except to ginseng powder and ginseng tablet.
        3,000원
        164.
        1990.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        다 자유도를 가 진 구조계 로 부터 얻어진 동적거동의 측정치를 이용하여 구조물 의 모우드 셰수를 추정 하는 시간영역방볍에 대해 연구하였다. 이를 위해 운동방정식올 실험적 모 우드식으로 변환한 다음 이를 다시 이산시간 영역의 식인 ARMAX식으로 나타내었다. 순차적 예측 오차 방법 을 이용하여 ARMAX 식의 계수들 을 추 정 한 후, 이들로 부 터 구조볼의 모 우 드 계수들을 계산하였다. 지 진 하중을 받는 3충 빌딩 구조볼 의 실험치 를 이용하여 얻은 모 우드 계수들 은 서로 다른 실험 간에 좋은 일치 를 보 였 으 며, 또한 계산된 계수들을 이용하여 다시 구한 구조품 웅답의 시간이력들은 실험치들과 좋은 일 치 를 보였다.
        4,000원
        165.
        1988.12 구독 인증기관 무료, 개인회원 유료
        본 연구는 식품의 동결시 동결기구의 설계 및 동결에너지의 효율적인 운용등을 위하여 동결상태에서 과일쥬스의 농도 및 온도변화에 따른 밀도변화를 예측하기 위하여 수행되었다. 10, 15, 20, 25, 30, 35, 40%농도의 Orange Juice, Apple Juice, Grape Juice 및 Sucrose Solation을 시료로 하여 온도강하에 의해 동결팽창되는 부위를 제거하므로써 거기에 따른 무게변화를 에서 까지의 온도범위에서 간격으로 각각 측정하여 밀도를 산출하였다. 그리고, Heldman의 식을 이용하여, 위의 농도와 온도범위에서 각 과일쥬스와 Sucrose Solution의 Unfrozen water fraction을 계산하였다. 실험을 통해 측정된 밀도데이타와 Unfrozen water fraction 데이타를 최적화 컴퓨터 프로그램을 이용하여 10%에서 40%까지의 농도범위와 에서 까지의 온도범위에서 Orange Juice, Apple Juice, Grape Juice 및 Sucrose Solution의 밀도를 예측할 수 있는 모델을 수립하였다.
        4,000원
        166.
        1980.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        4,000원
        168.
        2019.03 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 레이저기반 응력측정을 위한 비접촉식 로드셀을 개발을 위하여, 실내실험을 통하여 기술을 검증하고, 실규모 실험을 통하여 문제점을 파악하였으며, 최종적으로 현장적용에 적합한 응력측정용 비접촉식 로드셀 프로토타입을 개발하였다. 이를 위하여, 중심공 압축 타입의 로드셀 제작에 사용되는 로드셀 몸체 표면에 용사코팅기술을 이용하여 알루미나를 도포하고, 레이저를 기반으로한 압분광법을 이용하여, 비접촉식으로 응력을 계측하였다. 이때, 인가되는 응력과 스펙트럼 이동간의 관계가 선형임을 확인하였다. 해당 기술의 현장 적용성 확인을 위하여, 실규모 프리스트레스 콘크리트 시편을 제작하고, 레이저를 조사하여 인가된 응력을 확인하는 과정에서, 반복적인 상황 하에서 레이저 조사 위치가 동일해야 함을 확인하였다. 이를 보완하기 위하여 프로브를 고정할 수 있는 케이싱이 포함된 로드셀 프로토타입을 제작하였고, 실내일축압축시험을 통하여 압축력과 스펙트럼 이동간의 선형성을 확인하였다. 따라서, 본 연구를 통하여 개발된 비접촉식 로드셀을 이용하여, 압축력을 효과적으로 측정할 수 있을 것으로 기대된다.
        169.
        2019.02 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 체인을 선택하지 않고 수신된 모든 Loran-C 신호를 이용하여 위치를 측정하는 방법을 제안하였다. Loran-C 수신기 는 여러 체인 중 하나만을 선택하여 해당 체인에 속한 송신국 신호만을 위치 측정에 사용한다. 이에 따라 수신기가 위치를 계산하기 위해 사용 하는 신호의 수는 일반적으로 3∼5개로 제한된다. 만약 더 많은 신호를 사용하여 위치를 측정할 수 있다면 수신기의 측위 성능은 정확도와 가용성 측면에서 향상될 것이다. 다음으로 제안하는 방법의 유효성 여부를 확인하기 위해 실측 시험을 수행하였다. 육상 정지측위 시험 결과를 분석함으로써 제안하는 방법으로 위치 측정이 가능함을 확인하였다. 또한, 해상 이동측위 시험 결과는 일반적인 Loran-C 수신기가 위치를 측 정할 수 없는 상황에서 다중 체인 ToA 측위 방법으로 위치를 측정한 하나의 예시를 보여준다.
        170.
        2018.08 KCI 등재 서비스 종료(열람 제한)
        본 연구는 시뮬레이터 멀미 측정 도구인 SSQ를 이용해 가상현실 멀미를 유발시키는 지수를 도출하여 각 증상별로 심각도를 진단함으로써 가상현실 멀미를 위한 측정 방식을 제시하였다. 그래서 본 연구는 기존 가상현실 콘텐츠에서 주로 사용하는 1인칭, 3인칭게임 및 360° 실사 콘텐츠를 이용했고 SSQ를 이용하여 다양한 멀미 증상을 측정하였으며 통계분석을 통해 산출한 결과는 가상현실 멀미 증상을 완화하는데 기여하고자 한다. 또한 본 연구에서는 성별, 나이, 경험유무에 따라 가상현실 멀미에 차이가 있는지에 대해서도 통계방법론을 이용해 입증하였다.
        171.
        2018.02 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 세장체의 연속적인 거동을 전체 길이에 대하여 측정할 수 있는 계측시스템을 선정하며, 선정된 수중카메라 시스템의 성능평가를 수행한다. 수중카메라의 기초성능평가를 위하여 강체파이프의 강제가진 실험을 수행한다. 파이프의 상단을 강제가진장치에 고정시킨 후, 일정주기와 진폭으로 가진시켜 수중카메라를 이용하여 변위를 측정한다. 강제가진장치에 입력된 신호와 수중카메라에 계측된 신 호를 비교하여 측정 정밀도를 평가한다. 연속체인 세장체 파이프의 강제가진 실험을 수행하여, 수중카메라 시스템의 실시간 3차원적인 측정 가능성을 정성적으로 평가한다. 본 수중카메라 시스템은 향후 국내 심해공학수조에 적용되어, 세장체구조물 및 계류선 등의 거동 측정에 활용 될 것이다.
        172.
        2017.08 KCI 등재 서비스 종료(열람 제한)
        음향 도플러 유속계(Acoustic Doppler Current Profiler, ADCPs)는 하천의 유량측정에 널리 사용되고 있으나, 유량 측정성과의 불확도를 평가하는 방 법에 대하여 진행된 연구는 부족한 현실이며, 이는 실제 하천에서 유속 및 유량 등의 수리량을 조절하는 것이 현실적으로 불가능하여 ADCP의 불확도 요인 별 실험 및 분석이 어렵기 때문이다. 유량 및 수리량의 측정 불확도를 평가하기 위하여 과학 및 공학 분야에서는 다양한 연구들이 진행되어 왔으며, 그 중 국 제적으로 공인받고 있는 방법 중 하나가 GUM (Guide to the Expression of Uncertainty Measurement)이다. 본 연구에서는 GUM 표준안을 기반으로 ADCP의 유량 측정 불확도를 평가하기 위한 연구를 수행하였다. ADCP의 유량 측정 불확도 요인별 분석을 수행하기 위하여 유량 공급의 조절이 가능한 실 규모 수로를 보유하고 있는 하천실험센터에서 실험을 진행하였으며, ADCP의 측정 정확도에 영향을 미치는 수심, 측정 지점에서 하안까지의 거리, ADCP 의 잠김 깊이, 유속 오차, 측정 시간, 반복 횟수, 하상 조건 등에 대한 측정 정확도 평가 실험을 수행하였다. ADCP로 유량을 측정하는 방법은 지점측정방식 을 기반으로 유속-면적법을 통해 산정하는 방법과 일반적으로 사용되는 이동측정방식이 있으며, 본 연구에서는 ADCP의 지점측정방식을 통해 유량을 산정 하는 Section-by-Section 방법으로 산정된 유량의 불확도를 평가하였다. 모든 측정 결과는 요인별 불확도 평가를 수행하기 위하여 유속은 ADV, 수심은 광 파기로 측정된 결과와 비교하였다.
        173.
        2017.06 KCI 등재 서비스 종료(열람 제한)
        The aim of this study is to measure the exact average specific cake resistance in cake filtration. Using the new experimental method “filtration-permeation,” the average specific resistances were measured for various conditions as follows. First, the experiment with changing pre-sedimentation time and the filtration of sediment were conducted to determine the influence of sedimentation on the average specific resistance. There was a wide difference between the values of αav with various sedimentation times. Regarding the variation in the pre-sedimentation time, there was maximum 2.9x difference between the measured values of the average specific resistances for the filtration of calcium carbonate suspension. The “filtration-permeation” of bentonite floc and that of biological flow were also performed to establish a method for obtaining the average specific resistance of flocs.
        174.
        2017.06 서비스 종료(열람 제한)
        Despite the expectation that small green spaces provide high cooling effects, making air temperatures drop such effect in urban areas has been less explored in comparison to larger parks and urban forests. These knowledge gap has required advanced techniques to record spatial and temporal data and analysis small green spaces cooling effects. A temperature-sensing unit with ventilated double cylinder shelter (TVC) meets the needs and is known as an advanced device to record temperature data more accurately using a T-type thermocouple with a ventilator. This device also can be useful to develop guidance to describe thermal environment with a finer scale and an experimental research design for identifying air temperature data with spatial analysis using TVC. However, how we would conduct transect survey with this device and make a thermal map based on the collected data is not well known. The purpose of the study was to find out the usage of TVCs in collecting air temperature data and was to produce a thermal map of the study site and analyze temperature mitigation effect of each green space. The processes to create a thermal map required complicating, endeavoring and time-consuming works as well as skills to use computer programs for space drawing and spatial analysis. The overview of all the processed to get a thermal map should be helpful for researchers and students. Collected air temperature data and recorded time of them were downloaded, converted to Excel file (XLS) and ready to be analyzed through ArcGIS 9. In the mean time, recorded transect routes were drawn on the site map as polylines and made into spatial points through AutoCAD 2007. The routes consisted of five routes classified into the lawn, the rain garden, the residence, the prairie, and the forest. Separately, each route was drawn because it should reflect its spatial and temporal specification as for when the measurement was conducted. The spatial points of each route created by AutoCAD were converted to shape files (*.shp) and added fields of air temperature and time data in their attribute tables through ArcGIS. This work was done in each measurement hour and day. To create a thermal map, were shape files of each measurement time and the boundary of the site required. IDW (Inverse Distance Weighted) in ArcGIS was analyzed for each measurement hour (10h, 13h, 16h and 19h (20h)). In each analysis, the spatial points of measured air temperature were calculated to get an isotherm distribution for the measurement hour which we call a thermal map. The thermal maps show the air temperature distribution at 10h, 13h, 16h, and 20h. They also can show how land covers have an impact on the change of air temperature on their point and the surrounding areas. The air temperature of the prairie raises up in the morning (21℃) and continues to be cool during the day and after sunset. Meanwhile, the lawn starts at lower air temperature and goes to hotter. The residence is kept lower in its air temperature by big trees. The rain garden and the forest seem to have more time to discuss on why they are not sure their cooling effects.
        175.
        2017.05 서비스 종료(열람 제한)
        국내에서 토양 내 중금속 농도를 정량하기 위하여 다양한 분석장비 및 전처리관련 공정시험법이 존재한다. 대표적으로 환경부 토양환경공정시험법에서는 토양의 전분해(왕수추출)후 AAS 또는 ICP로 분석을 제시하고 있으며, 해양환경공정시험법에서는 퇴적물의 완전분해 후 분석이 제시되어 있다. 또한, 상기 화학적 전처리공정을 거치지 않는 XRD분석이나 입자를 레이저빔으로 승화시켜 측정하는 레이저 유도 붕괴 분광법(LIBS; Laser-Induced Breakdown Spectroscopy)도 상용화 되고 있다. 이러한 각종 전처리 및 분석 방법은 특히 전처리 정도에 따라 동일시료라 하더라도 경우에 따라 측정된 농도 값에 차이가 발생되나, 신기술이나 검증 등에 고려하지 않는 경우가 많기 때문에 혼란이 야기되는 실정이다. 따라서, 토양시료를 대상으로 전처리에 따른 분석결과차이를 증명하고, 이를 상용화 중인 LIBS분석방법과 비교하고자 한다. 중금속 오염토양 10가지를 대상으로 하였으며, 각 토양을 왕수분해(전분해)하고 충분히 반응시키고 원심분리하여 상등액을 분취하여 분석시료로 하였다. 이 왕수추출 후 잔류입자 내 잔류 중금속 농도를 정량하기 위하여 불산 등을 투입(완전분해)하여 잔류입자를 완전히 용해시켜 이를 분석시료로 하였다. 전분해와 완전분해는 각각 토양오염공정시험법과 해양환경공정시험법(-퇴적물)을 바탕으로 실험하였다. 중금속 농도 정량에는 ICP-OES(Perkin Elmer DV2100)을 사용하였으며, 총 5종(납, 아연, 구리, 크롬, 카드뮴)을 분석하였다. 추가로 동일 토양시료를 레이저유도 붕괴 분광법(LIBS)으로도 분석하여 이를 비교해 보았다. 토양시료 10개에서 납, 아연, 구리, 크롬의 분석농도는 완전분해(불산 등)대비 왕수분해(전분해)가 65~100%, 62~94%, 71~91%, 30~52%로 나타났으며, 이때 카드뮴은 검출되지 않았다. 토양 왕수추출 후에도 잔류입자(주로 실리카)에 중금속이 일부 존재하고 있는 것으로 나타났으며, 이는 전처리 후 입자유무에 따라 토양 에서 잔류중금속 농도 분석 값이 다를 수 있음을 나타낸다. 완전분해 시 납, 구리, 크롬, 아연 농도는 LIBS측정치 대비 평균회수율이 각각 87.8, 96.8%, 106.2%, 90.1%로 나타나 상대적으로 LIBS방법과 유사한 측정결과가 나타났다. 이는 완전분해 측정법과 LIBS측정법이 입자까지 모두 용해 또는 승화시켜 측정하는 방법이라는 점에서 유사하기 때문으로 판단된다.
        176.
        2016.06 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        일부 소스류 제품에 사용된 스탠딩 파우치에서 전자레인 지 가열조리 시 열변형이 발견되어 이의 원인을 규명하고자 온도 변화 패턴을 조사하였다. 전자레인지로 포장된 식품 을 가열 시 포장재의 온도 변화는 식품 자체의 온도보다 높고 국소적인 온도 측정 기술을 요한다. 공시 시료로 매운 맛 닭 소스와 인도카레의 전자레인지 가열 시 포장재와 시료의 온도를 열화상 카메라, 온도센서 테이프 및 광섬유 온도계를 이용하여 측정하였다. 스탠딩 파우치 형태의 포 장은 전자레인지 가열 조리 시 내용물의 불균일한 가열이 관찰되어 특정 부위, 특히 액위선 상단과 측면 sealing layer 에 열이 집중되는 현상이 발생하였다. 열화상 카메라를 이 용한 온도 측정 방법은 식품의 표면 온도를 측정하는 제약 이 있고 실제 식품의 온도보다 낮게 측정되는 경향을 보였 다. 온도센서 테이프를 이용할 경우 200℃까지 온도까지 측정되어 전자레인지 가열 과정 중 포장재 변형 현상이 야기될 수 있는 가능성을 확인할 수 있었다. 그리고 전자레 인지 가열 시 포장재 표면의 온도 변화를 기존 광섬유 온도 계로 측정할 경우 실제 온도보다 낮게 측정되는 결과가 초래되므로, 좁은 범위에서의 hot spot의 온도 변화를 감지할 수 있는 방법으로 GaAS crystal 센서를 사용함으로서 기존 센서보다 더 민감하고 정확한 온도 측정이 가능하였다.
        177.
        2015.10 서비스 종료(열람 제한)
        Conventional strain gauge can measure about 15~20% elongation. However, when the steel are ruptured, the strain at the necking region can be much higher than the measurement capacity of the conventional strain gauge. To measure the maximum strain at the necking region a new measurement technique should be developed. In this study, for this purpose image processing method for measuring 2-D strain distribution of tensile specimen of steel is proposed.
        178.
        2014.05 KCI 등재 서비스 종료(열람 제한)
        콘크리트용 무기계 방수제는 내부 막을 형성하지 않기 때문에 무기계 방수제의 침투깊이 정량적으로 평가하기 어렵다. 그러나 무기계 방수제의 침투깊이 평가는 일관된 침투효율을 확보하는데 있어서 매우 중요한 평가지표 중 하나이다. 따라서 본 논문에서는 콘크리트용 무기계 방수제의 침투깊이 측정방법을 고안하였으며, 고안된 침투깊이 측정방법을 통하여 기존 무기계 방수제의 침투깊이를 평가하였다. 실험결과 고안된 무기계 방수제의 침투깊이 측정방법을 통하여 평가된 침투깊이는 90% 이상의 신뢰성이 있는 것으로 나타났다.
        179.
        2014.04 KCI 등재 서비스 종료(열람 제한)
        The water resources system of Jeju-do Island entirely depends on groundwater. This study is making a precision observation of baseflow, surface water, water shortage that might be vulnerable to climate change and drought in future. The field observation of baseflow discharges in Akgeuncheon stream has regularly been made with ADCP and ADC and Flowmate every two weeks for twenty-two (22) months (July 8, 2011 to April 27, 2013). This paper represent the results of calculating discharge of a number of hydraulic structures (broad-crested weirs) with comparing and has been calculated more accurate discharges with suitability of different observation methods. The average discharge has been observed 0.851 m3/s, whereas the average ADC and Flowmate is 0.709 m3/s. Meanwhile, stream discharge has been calculated 0.709 m3/s through the broad-crested weir equation. The discharge has calculated with the weir equation greatly changed according to even a small change in the water level. However, it showed a similar trend to one of the observed discharge. Although, in past there were generating errors caused by observers’ strides, vertical and horizontal flow velocity distribution when the average flow velocity had been measured, non-prismatic flow, turbulent flow and others in ADC. This study comes up with the weir equation is more suitable for the characteristics of Jeju-do could be presented through an observations of baseflow discharge.
        180.
        2014.04 서비스 종료(열람 제한)
        Traditional methods for demolition of concrete structures and rocks are jackhammer and explosives methods. However, these traditional methods may not adequate specially for urban areas and historical places. Accordingly, an use of soundless chemical demolition agent (SCDA) increases in those areas. SCDA is similar to portland cement and lime is a key ingredient. In this study, expansive pressure from the selected SCDA were measured using outer pipe measuring technique and crack length due to the SCDA were simulated using obtained test data.