The condensation phenomenon can affect the product in terms of function and aesthetics, so it is a complaint of many users from the past, and continuous research has been conducted to solve it. A portable instrument panel is installed inside combat vehicles such as tanks and armored vehicles. Due to the nature of the combat vehicle operated in the special situation of battle, the internal heat generation of the instrument panel has increased significantly, which is presumed to be the cause of condensation inside the instrument panel. In this paper, a study on the development of subsequent processes was conducted to reduce the condensation phenomenon of the instrument panel for combat vehicles. In order to reduce the condensation phenomenon, the experiment was carried out by setting baking time and stabilization time as major factors. This paper is considered to be a reference research data for all systems in which similar assemblies are used as well as instrument panels for combat vehicles.
A provision crane is installed on the stern deck of the ship to load or unload ship supplies. In this study, a ventilation hole capable of circulating internal flow was installed to reduce dew condensation by reducing the temperature difference between the inside and outside of the cylindrical column supporting the provision crane installed at the stern of the training ship. In order to reduce the temperature difference between the inside and the outside, an anti-sweat covering work was carried out by adding insulation material. By reducing dew condensation, we aim to improve the insulation of the electric motor installed inside the cylindrical column and improve the usability of the provision crane
In this study, the types of thermal breakers applied to structures to prevent thermal bridges were identified. Condensation prevention performance was evaluated for apartment houses with standard floor structures to which a thermal breaker was applied. In addition, the effect of thermal cross-blocking was compared by calculating the total heat and equivalent U-value through the wall. (1) As a result of the evaluation of anti-condensation performance, when “가” grade insulation was applied, the surface temperature increased by about 1K due to the application of the thermal breaker. The TDR value increased by about 0.06 to 0.07. When "나" grade insulation was applied, the minimum surface temperature increased by about 1K, and the TDR value increased by about 0.05~0.06. (2) As a result of the evaluation of total heat and U-equivalent, it was possible to reduce the total heat by 38.5~44.9% and U-equivalent by 38.5~45.0% for the "가" grade insulation to which the thermal breaker was applied. In addition, the "나" grade insulation to which the thermal breaker was applied can reduce total heat by 38.9 to 43.6%, and reduce the Uequivalent by 38.9 to 43.7%.
This study is empirically intended to look into the effects of HVAC management on condensation cause and prevention in indoor swimming pools. The findings are summarized as follows.
First, the experience of condensation in indoor swimming pools showed that 132 out of 142 people in total experienced the condensation in indoor swimming pools, which they had a high experience rate of 92.3%. For the location of condensation, the wall joints were 46.8% and the windows were 34.5%, which a total of 72.3% occurred in the wall joints and windows. Second, the effect of construction design, HVAC management and building construction on the cause of condensation in indoor swimming pools showed that building construction had an effect on the cause and location of condensation depending on the seasonal time, partially adopting hypothesis 1. Third, the effect of condensation-causing factors on condensation-preventing factors in indoor swimming pools showed that condensation had a close relationship with air and temperature conditions depending on the time and location of condensation, adopting hypothesis 2.
As for the above-stated findings, the HVAC management in indoor swimming pools is an important concern factor that continues to cause condensation despite the development of advanced construction materials. Especially, building construction is a main factor that has a direct effect on condensation in the HVAC management of facilities. This implies that the window management is important in maintaining the wall joints - which can suppress the selective use and defect occurrence of construction materials - or confined spaces for a long time.
PURPOSES : This study analyzed the regional dew possibility in road sign using meteorological data. METHODS : Four years of meteorological data such as temperature, humidity, dew point, wind velocity were collected and analyzed. As a result of literature review, dew was frequent in large diurnal range, high humidity and weak wind. So, dew possibility was analyzed by (temperature-dew point ≤1℃ and wind velocity ≤ 1.5m/s). RESULTS : The possibility was analyzed for each meteorological observation point and the point of Suncheon and Bonghwa were selected as the most likely points of dew in road sign. The area of East Coast, Kyungbuk and Kyungnam were relatively low potential. CONCLUSIONS : Alternative with high effect of preventing dew should be selected in high possibility dew area despite of low economics.
PURPOSES : This research is to analyze the influence in terms of misreading rate and legibility time for drivers when condensation occurs on the road signs. METHODS : In this research, the dew occurred road signs provided to drivers to measure legibility time and misreading rate to compare with normal road sign. In order to identify the difference of legibility time between normal road sign and dew occurred road sign, the T-test and ANOVA test were used. And the vision system was used to recognize the region of dew occurrence on the road sign, then the brightness of dew occurrence region on the road sign was changed to check the misreading rate of drivers according to the change rate of brightness. RESULTS : The legibility times were measured 2.65s for normal road sign and 4.08s for dew occurrence road sign and misreading rates were measured 2.8% for normal road sign, 21.7% for dew occurrence road sign.
본 연구는 우리나라 온실 피복재의 결로 발생을 억제하는데 필요한 기초자료를 제공하기 위하여 토마토 재배용 실험온실의 포차변화 및 피복재에 발생하는 결로량의 변화를 분석하였으며 결과를 요약하면 다음과 같다. 실험온실의 경우 포차가 병 발생을 유발하기 쉬운 한계포차인 0.2kPa보다 더 크게 유지되어 온습도환경이 양호한 것으로 판단되었고 제습여부 결정을 위한 임계포차인 0.5kPa보다는 작게 나타나 제습은 필요한 것으로 판단되었다. 내부피복재의 표면온도는 외부온도와 커튼상부온도의 평균값 보다 약간 더 큰 것으로 나타났으며, 대체로 외부온도의 변화에 비례하여 변화하는 것으로 나타났다. 외부의 온도 및 습도 변화에 상관없이 커튼 상부의 습도는 거의 100%에 가까운 상대습도를 유지하여 결로 발생이 용이한 조건인 것으로 나타났다. 커튼하부의 습도는 내부습도의 큰 변화에도 불구하고 75~90% 정도로 안정된 값을 유지하였으며, 이는 온풍난방을 실시하여 온도를 15℃로 유지하였기 때문으로 판단된다. 실험조건 및 피복재의 종류에 따라 결로 발생량은 많은 차이가 있는 것으로 알려져 있다. 실험온실의 결로 발생량은 Seginer와 Kantz(1986)의 연구결과와 가장 잘 일치하는 것으로 나타났으나 다른 온실실험 결과들과는 약간의 차이를 보여주고 있기 때문에 앞으로 실험을 통해서 더 자세한 검증을 거친다면 우리나라 온실 피복재에 발생하는 결로량을 분석하는데 유용하게 활용될 수 있을 것으로 기대된다.
도로표지는 운전자에게 정보제공의 역할을 하는 도로시설물로서 주행경로에 대한 운전자의 판단을 도와준다. 그러나, 주 야간의 온도, 습도 변화로 인한 도로표지판에 결로발생 시, 정보전달의 결함이 발생하여 교통사고 가능성을 높이는 원인으로 작용한다. 따라서, 도로표지판의 결로발생을 예방하기 위한 기술이 필요하다. 본 연구에서는 도로표지판의 결로발생을 예방하는 대안의 효과를 비교하기 위해 단열소재가 삽입된 시편, 결로방지필름이 부착된 시편을 선정하고 결로방지처리가 되지 않은 일반시편과 비교하였다. 분산분석과 사후검정(Tukey HSD)을 통해 각 시편에 발생한 측정시간에 따른 결로량을 비교 했으며, 결로량과 재귀반사도의 관계를 Pearson의 상관분석으로써 검증하였다. 분석결과, 결로방지필름이 부착된 시편에서 결로량이 적게 나타났으며, 결로발생 90초 후에는 결로방지필름의 부착 시편과 단열소재가 삽입된 시편에서 나타나는 결로량은 결로방지 처리가 되지 않은 시편에서 발생한 결로량과의 통계적인 차이가 존재하였다. 또한, 상관분석결과로써 결로량과 재귀반사도는 반비례하는 것으로 나타났다. 따라서, 도로표지판에 발생된 결로량과 재귀반사 변화율에 대하여, 결로방지필름의 부착과 단열소재의 삽입은 결로방지에 효과가 존재하는 것으로 판단된다.
선박에 적재된 곡류, 철강재 등의 산적화물에 여러 가지 이유로 손상이 발생될 수 있다. 본 논문에서는 코일 운반선의 화물손상 원인 중 특히, 결로에 의한 손상과 그에 대한 방지대책에 대해 분석하고자 한다. 결로란 주위 온도가 이슬점 이하로 떨어져 물체 표면에 공기 중의 수증기가 물방울로 맺히는 현상을 말하며 일반적으로 실내외 온도차가 큰 건축물이나 선박의 화물창에서 많이 발생한다. 특히, 비슷한 시기에 기온차가 있는 전 세계를 운항하는 선박에서 흔히 발생할 수 있는 현상이다. 본 연구에서는 코일 운반선의 결로에 의한 화물손상 방지 대책에 대해 고찰하고 화물손상을 방지하기 위해 제습장치와 가열온풍장치를 병용하는 새로운 방법의 제안과 습도, 습기량, 제습장치 용량, 결로수량, 화물 및 공기와 외기의 온도 차이에 따른 화물창 내 공기와 화물 가열에 필요한 열량, 가열장치 용량 등의 산정법을 제시한다.
본 연구는 우리나라의 기상환경에 적합한 한국형 공기주입 이중피복 플라스틱 온실을 설계하는데 필요한 기초자료를 제공하기 위하여 실험용 공기주입 이중피복 플라스틱 온실을 제작하여 작동실험을 실시하고 온실내부의 환경변화를 분석하였다. 온실의 피복재를 설치할 때 시공기술이 부족하여 밀폐도가 많이 떨어지는 것으로 나타났기 때문에 이중피복 공기충의 정압을 적절하게 유지하기 위해서는 높은 밀폐도를 유지할 수 있는 피복재 설치기술과 관련 자재의 개발이 요구되었다. 관행의 이중피복온실보다 공기주입 이중피복온실이 단열효과가 더 우수하였으며, 특히 아치형 지붕형태의 공기주입 이중피복온실이 복숭아 형태의 관행온실에 비해 2℃ 정도 높아 보온효과가 상당히 우수한 것으로 나타났다. 시공성이 우수하고 밀폐도를 높일 수 있는 피복방식은 온실위에 피복재를 덮은 상태에서 여유길이를 두지 않고 자연스럽게 고정시키는 것이 가장 바람직하였다. 다른 조건들이 동일한 공기주입 이중피복 단동온실의 경우 복숭아형 지붕온실에 비해 아치형 지붕온실에서 광투과율이 더 높은 것으로 나타났다. 3연 동 온실의 경우에는 관행 이중피복온실에 비해 공기주입 이중피복온실이 광투과율이 더 높은 것으로 나타났으며, 이는 주로 골조율과 이중피복재간의 간격 때문인 것으로 판단되었고, 이에 대한 자세한 원인은 앞으로 추가적인 실험을 통해 검증할 예정이다. 결로의 발생현상을 가시적으로 비교한 결과 관행온실에서 더 많은 결로가 발생함을 확인할 수 있었다 그러나 정량적인 비교를 위해서는 장기간의 관측과 이론적인 분석이 필요할 것으로 판단되며, 향후 더 자세한 실험을 통해 규명할 예정이다.
In this paper, it is intended to investigate the condensation characteristics of a supply vent cap, which is designed and developed for natural ventilation systems for ondol heating spaces. Numerical simulations are conducted using a CFD package to analyze airflow and thermal conditions around the vent cap. Temperature and humidity distributions are obtained to predict condensation on the surface, depending on the material properties. As the thermal conductivity decreases, decreased is the condensation surface area. The thermal conductivity of the vent cap is found to be less than 1 W/mK in order to prevent condensation under the winter design condition of Seoul. An experimental technique is introduced to visualize condensation on surfaces using water-absorbing mud film. Analytical results are in good agreement with experimental observations. Discussion are also included for the thermal comfort and flow characteristics around the vent cap observed by the flow visualization and temperature visualization studies.
Generally, the dew condensation generated in the tunnel does not directly affect the concrete structure However, falling water due to dew condensation brings directly with a high possibility of defection to the train line.
In addition, moisture inflow due to dew condensation may induce malfunction or failure of various electric and fire facilities installed in the tunnel, which may cause abnormal signals or accidents and so on. In this paper, we explain the case of dew condensation site and analyzed the cause.