검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 13

        2.
        2022.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Effects of substrate bed interior environments on mushroom qualities were investigated in oyster mushroom cultivation facilities in which either Reversible Air-Circulation Fans (RACF) blowing air in two directions (upwards and downwards) or customary Convection Fans (CF) with air blowing only upwards were operated throughout the cultivation period. Two days before harvest, the deviation ranges of the bed interior temperature and relative humidity in the facility using RACF were in the ranges of 1.0-1.3oC and 7.8-9.0% in the first growing cycle, and within 0.7-1.1oC and 10.0-11.4% in the second cycle. In the facility using CF, the ranges of variation in the indoor environment parameters (5.8-6.4oC and 21.3-23.1% in the first growing cycle, and 3.4-5.7oC and 14.6-18.3% in the second growing cycle) were much enlarged compared to those associated with RACF. These results strongly indicate that RACF significantly enhances air uniformity. Some mushroom qualities differed between growing cycles. For instance RACF in the first cycle gave somewhat better qualities than CF, but some qualities, like pileus diameter and stipe length, were slightly lower than those described for CF in the second cycle when the cultivation substrate weakened. The observation that some qualities worsened under RACF conditions, despite better air uniformity during the growing cycle, revealed the possibility that downward wind may exert a non-negligible negative effect on mushroom growth. Therefore in the future, making wind measurements on the interior and exterior of substrate beds is necessary to obtain insights into their influences on mushroom qualities. The RACF operation manual needs to be edited to convey this necessity.
        4,200원
        3.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 방울토마토 재배 단동온실에 공기순환팬을 설치하고 공기순환팬이 온실 내 온도 및 습도 분포, 에너지소비량에 미치는 영향을 분석하였다. 공기순환팬은 날개 크기 230mm의 Stainless 팬으로, Lee 등(2016)의 연구결과를 참고하여 시험구 온실에 9m 간격으로 총 18 대를 설치하였다. 온실 내부 온습도는 온실 길이방향으 로 4등분하여 1/4 지점과 3/4 지점의 중앙에 센서를 설치하고 0.8m, 1.8m 높이 2곳의 온습도를 난방을 주로 하는 야간(오후 6시~다음 날 오전 7시)에 5분 간격으로 측정하였다. 에너지소비량은 각 온실에 위치한 온수펌프의 유량, 온수 출수부와 환수부의 온도차를 측정하여 계산하였다. 공기순환팬을 사용하지 않았을 때 측점 간 온도차 및 습도차의 평균값은 0.75oC, 2.19%였으며 공기 순환팬 사용 시 측점 간 온도차 및 습도차의 평균값은 0.42oC, 1.27%로 감소하였다. 공기순환팬 설치 온실과 미설치 온실의 누적 에너지소비량은 각각 4,673kWh, 4,009kWh로 공기순환팬 설치 온실에서 약 14.2%의 에너지를 적게 소모하였다. 이러한 결과로 보아 온실 내 공기순환팬 사용은 공기를 지속적으로 교반시켜 주어 온실 전체의 온도 및 습도를 균일하게 만들고, 공기의 온도가 빠르게 변하지 않도록 해주어 난방 장치의 가동 시간과 에너지소비량을 줄일 수 있다.
        4,000원
        4.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 폭 7m, 길이 25m, 동고 3.2m의 토마토를 재배하는 온실에 공기순환팬을 설치하고 순환팬이 온실 내 온도 및 습도 분포에 미치는 영향을 조사하였다. 기존의 순환팬 설치 기준(ASAE, 1997)을 참고하여 시험 온실에 순환팬 10대를 2열 및 다른 방향으로 설치하여 18시부터 다음날 8시까지 온실 내 온습도를 측정하였다. 온실 내 온습도는 온실을 9개의 격자망으로 나눈 후 온실 중앙부에서는 0.7m, 1.7m 및 2.7m 높이, 온실 좌우 측에는 0.7m, 1.7m 높이에 센서를 설치하였다. 공기순환 팬을 사용하지 않았을 때 온실 상하부의 온도 및 습도의 평균값은 14.7oC, 74.8%와 13.0oC, 85.6%로 온습도 차는 평균적으로 1.7oC, 10.8% 발생하였다. 공기순환팬 10대를 2열 및 다른 방향으로 설치하여 운용했을 때 온실 상하부의 온습도는 14.6oC, 75.9%와 14.5oC, 79.1% 로 온습도 차는 각각 0.1oC, 3.2%였으며 순환팬을 사용 하지 않았을 때와 비교하여 온실 상하부의 온도 및 습도 차가 감소하였다. 순환팬을 6대 및 5대로 줄여서 운용했을 때 온실 상하부의 온습도 차는 각각 0.3oC, 3.4%와 0.3oC, 4.0%로 나타나 순환팬 10대를 사용했을 때와 비슷한 효과를 보였다. 순환팬 10대를 2열 및 같은 방향으로 설치했을 때의 온실 상하부의 온습도 차는 0.5oC, 4.9%로 팬을 다른 방향으로 설치했을 때보다 온습도 차가 크게 나타났다. 온실 좌우측면, 전후면의 온습도 차를 살펴보면 순환팬을 사용하지 않았을 때 좌우 측면의 온습도 차는 0.3oC, 1.7%로 작아 팬을 사용했을 때와 큰 차이가 없었으나 순환팬을 사용하지 않았을 때 1.0oC, 4.2%로 나타났던 전후면의 온습도 차는 순환팬을 사용함으로써 감소하였다. 이는 공기순환팬이 온실 내 공기를 순환시켜 온풍난방 시 상부에 정체된 더운 공기나 열손실로 인해 온도가 다른 공기를 교반시킴으로써 온도 및 습도 차가 감소한 것이다. 폭 7m, 길이 25m, 동고 3.2m인 단동온실에서 날개 크기 230mm, 풍량 11m3/min의 공기순환팬을 사용하고자 할 때는 순환팬 5대를 2열로 설치하되 각 열을 방향을 다르게 하고 9m 간격으로 설치하여 운용하는 것이 가장 경제적이고 효과적일 것이다.
        4,000원
        5.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        근권부 공기순환 덕트 냉방이 온도 및 생육에 미치는 영향을 구명하고자 고온기 파프리카((Capsicumannum.L. ‘Veyron’)을 코이어배지에서 수경재배하였다. 냉방시간 처리는 24시간 연속 가동한 연속냉방(All-day), 17시부터 다음날 1시까지 8시간 냉방한 야간냉방(Night), 대조구인 냉방 무처리(Control) 등 3 처리하여 온실 상·하부 온도, 근권온도, 엽온, 과실 특성 및 기관 분배율을 측정하였 다. 근권부 덕트 냉방하였을 때, 고온기(6월 ~8월) 온실 하부(바닥으로부터 40cm)와 상부(바닥으로부터 180cm) 온도, 근권온도는 하강되었다. 대조구와 비교하여 온실 하부/상부 온도 차이가 연속냉방에서는 4.4~5.1oC/ 2.1~3.1oC 하강을, 야간냉방 처리에서는 3.4~3.8oC/ 2.2~2.7oC 하강되었다. 근권온도는 온실 하부 온도 결과와 유사했으며, 연속냉방(22.8oC)> 야간 냉방(24.1oC) > 대조구(27.7oC) 순으로 온도가 낮았다. 연속냉방 처리에서 덕트 위치(통로, 베드하단)와 송풍 방향(45o, 90o, 180o)에 따른 온도 변화를 측정한 결과 덕트의 위치가 통로에 위치하고 송풍방향이 상향(45o) 또는 수평(180o) 인 처리는 지상부 100cm까지의 수직 위치에 따른 온도 차이가 크지 않지 않으면서, 근권부위 온도인 지상 50cm 온도가 낮은 특징을 보였고 베드와 베드 공간 사이로 덕트 송풍 방향이 직각(90o)이였을 때는 바닥과 지 상 50cm 부위의 온도가 높고, 지상 100cm 이상 200cm 부위 온도가 상대적으로 낮았다. 연속냉방 또는 야간냉방 처리했을 때 파프리카 엽온은 오후 7시가 오전 9시 보다 엽온 하강이 컸다. 과실 분배율은 대조구(24.4%)에 비해 연속냉방(48.6%)과 야간냉방(45.6%)에서 높았으며, 평균과중, 과수 및 수량도 연속냉방 처리에서 가장 높았다. 한편 야간냉방 처리에서도 고온기 평균 지상부 및 근권온도를 낮추었으나, 누적된 평균온도가 가장 낮은 연속냉방처리에서 과실로의 동화산물 분배율을 높여 파프리카 수량을 증가시킨 것으로 보인다.
        4,000원
        6.
        2010.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The feasibility study for reducing ship resistance was carried out. A thin plate was installed in front of bow to guide the air which was induced to the bottom just following to the hull surface when ship is running fast. To confirm the reduction of surface friction, model test in the high speed CWC and numerical simulation were implemented. The results show that the induced air to the bottom is increasing according to the increasing of air velocity and it plays an important role to reduce the frictional resistance.
        4,000원
        7.
        2007.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구는 순환팬에 의해 만들어지는 수평적인 공기흐름이 환경요인들의 수평 및 수직분포에 미치는 영향을 조사하기 위해 수행하였다. 순환팬 가동 유무에 따라 기류 속도, 기온, 상대습도 및 CO2농도의 3차원 분포를 측정하였다. 온실내 기상인자 분포의 균일성은 외기온이 낮아짐에 따라 감소하였다. 무처리시 기온 편차는 4.7, 습도 편차는 19%이었는데 팬을 가동한 경우 그 편차들은 각각 2.2, 6.3%로 감소하였다. 팬 용량이 증가할수록 측점간 기온 편차가 줄어들었는데, 온실 바닥면적당 0.0104m3·s-1 용량의 팬으로 온실내 적정한 공기 유동을 만들 수 있었다. 기온 및 CO2 농도의 수직분포는 높이나 팬 용량에 관계없이 상당히 균일한 것으로 나타났다. 폭 방향의 기온 편차를 줄일 수 있는 팬 배치와 소용량의 팬을 다수 설치했을 때의 효과에 대한 연구가 더 필요할 것으로 생각된다.
        4,000원
        8.
        2001.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        저온기 참외 시설재배시 시설내 공기흐름의 촉진이 발효과 발생 경감에 미치는 효과를 구명하기 위하여 하우스에 공기순환 및 환기팬을 설치하여 착과 5일 후인 4월 6일부터 6월 29일까지 비 오는 날을 제외한 모든 날의 09시 30분부터 15분간 처리 후 15분간은 정지시키는 방법으로 17시까지 가동하여 관행(권취식환기)과 비교 시험한 결과 작물체 부위의 풍속은 무처리는 0.06~0.08m.s-1, 환기팬은 0.24~0.32m.s-1, 공기 순환기는 0.60~0.72m.s-1였다. 무처리에 비하여 공기순환 처리에서 엽장, 엽폭 등 생육은 처리간 차리가 없었으나 일비액량은 공기순환처리에서 월등히 증가하였다. 무처리에 비하여 공기순환 처리에서 발효과율이 유의하게 감소하였으나 환기팬처리와는 큰 차이가 없었다.
        4,000원
        9.
        2013.04 KCI 등재 서비스 종료(열람 제한)
        The objective of this research was to suggest the estimation method of air injection quantity for pre-stabilization of landfilled wastes in a sustainable landfill. A study on the determination of oxygen demand quantity of landfilled wastes, therefore, was conducted in two different experiments. Firstly, a batch test was performed in order to measure the oxygen quantity required to oxidize easily degradable organic matter under aerobic conditions. Secondly, a lysimeter experiment was carried out to assess the air injection period according to moisture content (20%, 30%, 40%, 50%) and to validate the oxygen demand quantity obtained by the batch test. This study assumed that landfilled wastes contain two different organic matters and two matters are sequentially utilized by microorganism. The first one provides the faster oxygen uptake rate that called the “easily degradable organics”. During the second phase of the aerobic decomposition, the other one provides the slower oxygen uptake rate that called the “moderately degradable organics”. Also, in this study, a modified logistic equation divided two terms (fractions of easily degradable organic and moderately degradable organic) was suggested to determine the oxygen demand quantity for easily degradable organic of landfilled solid waste. As a result, the oxygen demand quantity obtained by the batch test led to similar results compared with that of lysimeter experiment. Therefore, it showed that the modified logistic equation and batch test were appropriate for determination of oxygen demand quantity for decomposition of easily degradable organic matter. Also, air injection period for decomposition of easily degradable organic decreased with the increase of moisture content.
        10.
        2010.02 KCI 등재 서비스 종료(열람 제한)
        Air mass recirculation is a common characteristic in the coastal area as a result of the land-sea breeze circulation. This study simulates the recirculation of air mass over the Gwangyang Bay using WRF-FLEXPART and offers a basic information about the effective domain size that can reflect recirculation. For this purpose, WRF is set up four nested domains and three cases are selected. Subsequently FLEXPART is operated on the basis of WRF output. During the clear summer days with weak wind speed, particles that emitted from Yeosu national industrial complex and Gwangyang iron works flow into emission sources because of the land-sea breeze. When land-sea breeze is strengthen, the recirculation phenomena appears clearly. However particles aren't recirculated under weak synoptic condition. Also plume trajectory is analyzed and as a consequence, the smallest domain area have to be multiplied by 1.3 to understand recirculated dispersion pattern of particles.