Since atypical high-rise buildings are vulnerable to gravity loads and seismic loads, various structural systems must be applied to ensure the stability of the structure. In this study, the authors selected a 60-story twisted-shaped structure among atypical high-rise structures as an analytical model to investigate its structural behavior concerning the outrigger system. The structural analyses were performed varying the number of installed layers and the arrangement of the outrigger system, as well as the placement of the mega column, as design variables. The analysis revealed that the most effective position for the outrigger was 0.455H from the top layer, consistent with previous studies. Additionally, connecting outriggers and mega columns significantly reduced the displacement response of the model. From an economic standpoint, it is deemed efficient to connect and install outriggers and mega columns at the structure's ends.
In this study, we investigated the dynamic characteristics of three irregular building models to analyze the effectiveness of displacement response control with Tuned Mass Damper (TMD) installation in twisted irregular buildings. The three irregular models were developed with a fixed angle of twist per story at one degree, subjected to three historical seismic loads and resonant harmonic loads. By designing TMDs with linear and dashpot attributes, we varied the total mass ratio of the installed TMDs from 0.00625% to 1.0%, encompassing a total of 10 values. Two TMDs were installed at the center of the top story of the analysis model in both X and Y directions to evaluate displacement response control performance based on TMD installation. Our findings suggest that the top displacement response control performance was most effective when a 1.0% TMD was installed at the top layer of the analysis model.
이 논문에서는 박스형 전력구의 지진응답해석에 사용되는 응답변위법(Response Displacement Method, RDM)의 보수성을 평가하였다. 이를 위하여 25가지 전력구 단면과 각 전력구에 대한 2개의 지반조건을 고려한 총 50개 예제를 선정하였다. 응답변위법에 의한 해석은 다음과 같은 세 가지 방법을 적용하였다: (1) 단일코사인방법, (2) 이중코사인방법, (3) 부지응답해석법. 그리고 이들 응답변위 법의 보수성을 평가하기 위하여 지반-구조물 상호작용을 고려한 동적해석법으로 구한 응답과 비교하였다. 비교결과, 설계지진력을 결정하는 방법 중에서 부지응답해석법이 가장 변동폭이 작았으며, 이중코사인방법이 가장 보수적인 결과를 보였다. 마지막으로 이중 코사인방법을 적용할 때, 응답변위법에 의한 부재력이 동적해석에 의한 값보다 클 확률이 80% 이상이 되기 위한 지반강성 보정계수 C값으로 기능수행수준에서 0.9, 붕괴방지수준에서 0.7을 추천하였다.
As people's living standards and cultural standards have developed, interest in culture and art has increased, and the demand for large space structures where people can enjoy art, music, and sports has increased. As it accommodates a large number of personnel, it is most important to ensure safety of large spatial structures, and can be used as a space where people can evacuate in case of a disaster. Large spatial structures should be prepared for earthquake loads rather than wind loads. In addition to damage to the structure due to earthquakes, there are cases in which it was not utilized as a space for evacuation due to the fall of objects installed on top of the structure. Therefore, in this study, the dome-shaped large spatial structure is generalized and the displacement response according to the number of installations, position and mass is analyzed using a tuned mass damper(TMD) that is representative vibration control device.
The seismic deformation method is conventionally used as a seismic design for a multi-utility tunnel in Korea. In the seismic deformation method, the soil ground’s natural period is one of the most critical factors for calculating the ground displacement using cosine functions. Correction factors for the natural period and shear wave velocity have been used to consider the non-linearity of dynamic soil properties. However, the correction factors have been issued because the correction factors have not been sufficiently studied to consider Korea’s regional conditions. This paper aims to evaluate the natural periods for the seismic deformation method considering Korea’s ground conditions. Ground response analysis was performed using seven real earthquake records on twelve sites with different soil conditions where actual multi-utility tunnels are installed. As a result, natural periods of the sites were analyzed and new correction factors were proposed according to seismic performance and Korea’s regional conditions.
In this paper, the displacement response to seismic loads was analyzed after installing TMD in spatial structures and high-rise buildings. In the case of a spatial structures, since it exhibits complex dynamic behavior under the influence of various vibration modes, it is not possible to effectively control the seismic response by installing only one TMD, unlike ordinary structures. Therefore, after installing eight TMDs in the structure, the correlation between displacement response and mass ratio was examined while changing the mass. The TMD must be designed to have the same frequency as the structure frequency so that the maximum response reduction effect can be exhibited. It can be confirmed that the most important variable is to select the optimal TMD mass in order to install the TMD on the structure and secure excellent control performance against the earthquake load. As a result of analyzing the TMD mass ratio, in the case of high-rise buildings, a mass ratio of 0.4% to 0.6% is preferable. In spatial structures, it is desirable to select a mass ratio of 0.1% to 0.2%. Because this study is based on the theoretical study based on numerical analysis, in order to design a TMD for a real structure, it is necessary to select within a range that does not affect the safety of the structure.
Lightly reinforced concrete (RC) moment frames may suffer significant damage during large earthquake events. Most buildings with RC moment frames were designed without considering seismic loads. The load-displacement response of gravity load designed frames could be altered by masonry infill walls. The objective of this study is to investigate the load-displacement response of gravity load designed frames with masonry infill walls. For this purpose, three-story gravity load designed frames with masonry infill walls were considered. The masonry infilled RC frames demonstrated larger lateral strength and stiffness than bare RC frames, whereas their drift capacity was less than that of bare frames. A specimen with a partial-height infill wall showed the least drift capacity and energy dissipation capacity. This specimen failed in shear, whereas other specimens experienced a relatively ductile failure mode (flexure-shear failure).
The tendency to use a probabilistic design method rather than a deterministic design method for the design of nuclear power plants (NPPs) will increase because their safety should be considered and strictly controlled in relation to various causes of damage. The distance between a seismically isolated NPP structure and a moat wall is called the clearance to stop. The clearance to stop is obtained from the 90th percentile displacement response of a seismically isolated NPP subject to a beyond design basis earthquake (BDBE) in the probabilistic design method. The purpose of this study is to analyze the effects of heating and buckling effects on the 90th percentile displacement response of a lead-rubber bearing (LRB) subject to a BDBE. The analysis results show that considering the heating and buckling effects to estimate the clearance to stop is conservative in the evaluation of the 90th percentile displacement response. If these two effects are not taken into account in the calculation of the clearance to stop, the underestimation of the clearance to stop causes unexpected damage because of an increase in the collision probability between the moat wall and the seismically isolated NPP.
가속도로부터 변위를 계산 방법 중 상대적으로 사용이 간단한 변위재구성기법이 Lee et al.(2010)과 Hong et al.(2010)에 의해 제안되었다. 목표주파수는 변위재구성기법을 사용할 때 사용자가 결정해야 할 중요한 변수 중 하나로 이것을 결정하기 위해선 주파수영역 분석에 대한 경험이 필요하다. 이 논문은 지진하중을 받는 사장교에 한정된 변위재구성기법의 목표주파수 결정 방법을 제시한다. 사장교가 지진에 의해 가진될 경우 목표주파수는 유효한 모드의 고유주파수 중 가장 낮은 주파수로 결정된다. 여기서 유효한 모드라 함은 가속도의 자유도에 유의미한 영향을 주는 모드형상을 가진 모드를 의미한다. 제안된 목표주파수 결정방법의 타당성을 검증하기 위해 포항지진 발생 당시 측정된 3개 실 교량의 주경간 중앙에서 측정된 가속도와 변위 시간이력을 분석했다. 또한 제안된 방법을 포항지진 발생 당시 측정된 실교량의 주탑 상단 가속도에 적용해 계산된 변위를 분석했다.
고층 건축물의 내풍설계 시 다차모드 해석의 수행이 필요하다. 고층건축물의 다차모드 해석을 위해서 풍압적분법과 1차모드 해석을 수행하였으며, 풍압적분법을 활용하여 층별 시간이력 전도모멘트를 산출하였다. 층별 전도모멘트를 산출하기 위해 풍압적분법을 활용하였고, 그 방법으로 임의의 층까지의 누적 풍력데이터로부터 층별 시간이력의 전도모멘트를 산출하였다. 풍응답변위는 각 층별 전도모멘트로부터 1차 모드 해석을 수행하여 평가하였다. 본 연구 결과의 그 유효성을 높이기 위해, 건축물 전체에 작용하는 풍력데이터에 의해 얻어진 풍응답 결과와 비교하였다. 두 연구 결과는 유사한 것으로 나타났다.
최근 대형구조물의 유지관리에 대한 관심이 커지고 있으며 자연재해, 구조물의 노후 등으로 구조적 안전성의 검토가 요구되는 대형구조물의 수가 급증하고 있는 실정이다. 실제 사용하고 있는 구조물의 구조적 특성은 최초 설계 당시의 특성과 차이점을 보이는 것이 일반적이며 부재의 균열 및 구조물의 노후화 등으로 인한 강성저하에 의하여 구조물의 동특성에 변화가 나타날 수 있다. 구조물의 동특성의 변화를 관찰하면 손상의 위치를 파악할 수 있으며 정량적 평가 또한 가능하다. 교량, 건물 등 구조물 모니터링에 사용되는 대표적 계측장비가 동적계측기이다. 현재 구조용 동적계측기는 각 센서와 계측기를 1:1로 연결하는 방식을 취하고 있어 많은 케이블 작업을 필요로 하기 때문에 센서를 부착하지 않고 원거리에서 진동을 측정하는 방법이 필요하다. 구조물의 동적응답 계측을 위하여 적용 가능한 비접촉식 방법으로는 레이저의 도플러효과 및 GPS를 이용하는 방법 등이 있으나 비경제적이기 때문에 교량구조물에 적용하기에 보편적이지 못하다. 그러나 영상 이미지를 이용하는 방법은 경제적이며 접근이 어려운 구조물의 진동 및 동특성 추출에 적합하다. 기존에 도 센서를 대신하여 카메라의 영상신호를 이용하는 연구가 수행되었으나 구조물에 부착된 target의 한 지점을 기록한 후 이미지 처리기법 을 이용하여 변위응답을 측정하는 방법으로서 측정 대상이 비교적 국한적일 수 있다. 그러므로 본 연구에서 제안한 DIC(Digital Image Correlation)기법을 이용한 다중 변위응답 측정기법을 검증하기 위하여 실내모형실험을 수행하였다.
마찰형 감쇠를 갖는 구조물은 구조물의 고유주기, 하중의 특성, 그리고 외부하중에 대한 마찰력의 상대적인 크기에 따라 강한 비선형성을 나타내므로, 구조물의 최대응답을 예측하기 매우 어렵다. 기존의 연구에서는 비선형 시스템을 등가의 선형 시스템으로 치환하거나, 구조물의 비선형 시간이력해석을 통한 응답스펙트럼 분석에 의한 간단한 확률해석에 의해 수행되었다. 지진 하중은 불확실성과 불규칙성을 갖고 있기 때문에 확률적으로 정의된다면, 지진하중을 받는 마찰형 감쇠를 갖는 구조물의 응답 역시 확률분포를 나타낼 것이다. 본 논문에서는 Kanai-Tajimi 필터를 이용해 생성된 인공지진하중에 대해 마찰형 감쇠를 갖는 구조물의 비선형 시간이력 해석이 수행되었다. 그리고 정규분포 확률밀도 함수에 선형 회귀분석을 통해 얻어진 구조물의 주기와 마찰력의 크기에 의한 변수를 업데이트 시킨 마찰형 감쇠를 갖는 구조물의 변위 응답 확률밀도함수식이 제시된다.
고층건물의 진동응답을 저감시키기 위한 다양한 방법들이 연구되고 있다. 이들 진동응답의 저감 연구는 건물의 외관을 병화 시키는 방법과 건물에 부가감쇠장치를 설치하는 방법들이 있는데 본 논문에서는 고층 건물의 형태의 변화에 다른 진동변위응답의 특성을 파악하고자 한다. 고층건물의 형태변화 중에서도 외관에 테이퍼를 수는 방법을 사용하였다. 기류의 특성은 도심 및 교외지역을 중심으로 풍동실험을 실시하였다.
성능설계법에서 다층 건축물의 내진성능을 평가하기 위해서는 다자유도계를 등가 1자유도계로 변환할 필요가 있다. 본 논문은 다자유도계를 등가 1자유도계로 변환하여 다층 골조구조물의 층간변위 응답을 추정하는 방법을 제안한다. 본 연구의 목적은 다층 골조구조물과 등가 1자유도계의 시간이력해석을 수행하여 등가 1자유도계 변환 방법의 타당성을 확인하는 것이다. 다층 골조구조물의 시간이력해석에 의한 층간변위 응답과 등가 1자유도계에 의해 추정된 층간변위 응답을 비교하여, 등가 1자유도계에 의한 층간변위 응답에 대한 추정 방법의 타당성을 확인한다. 본 연구에서 얻어진 결과는 다음과 같다. 시간이력해석을 통하여 다자유도계를 등가 1자유도계로 변환하는 방법의 타당성을 확인할 수 있었다. 다층 골조구조물의 층간변위 응답은 비탄성 1차 모드를 이용한 등가 1자유도계의 변위응답으로부터 보다 정확히 추정할 수 있었다.
본 연구에서는 지하구조물의 내진 설계를 위한 수정된 응답변위법을 제안하였다. 먼저 기존 응답변위법의 적용성을 검증하기 위해서 매설심도와 지반조건을 변수로 하여 국내의 특성이 반영된 경우에 대한 해석을 수행하였으며 정밀 동적 해석의 결과와 비교하였다. 최대휨모멘트 및 상대 변위를 비교한 결과, 응답변위법의 정확도에 영향을 크게 미지는 속도응답스펙트럼과 지반반력계수 산정의 필요성이 확인되었다. 따라서 국내의 실정에 맞도록 수정된 속도응답스펙트럼과 새로운 지반반력계수 산정식 제안을 위한 방법을 고찰하였다. 제안된 응답변위법의 타당성 및 적용성을 검증하기 위하여, 지반의 조건 및 구조물의 크기 매설심도, 기반암의 위치를 변화시키면서 해석을 수행하였다. 응답변위법의 해석결과와 정밀 동적 해석법의 결과를 비교ㆍ분석하여 국내 지하구조물의 내진 설계를 위한 응답변위법의 적용 가능성을 검증하였다.
탄성응답스펙트럼을 사용하는 능력스펙트럼법은 비선형 시스템을 등가의 선형시스템으로 치환하여 주어진 지진 하중에 대한 구조물의 최대 비선형 거동을 예측한다. 본 연구의 목적은 이러한 능력스펙트럼법들의 정확성을 검증하고, 예측 특성을 비교하는 것이다. 이를 위해, ATC-40, G lkan, Kowalsky, 그리고 Iwan이 제시한 방법을 이용하여 등가주기와 등가감쇠비를 산정한 후, ATC-40에서 제시한 절차B에 따라 성능점을 산정 하였다. 전반적으로 ATC-40 방범은 구조물의 응답을 과소 평가하여 안전하지 못한 설계결과를 가져 올 수 있으며, G lkan과 Kowalsky의 방법은 과대 평가하는 경향을 가지고 있다. Iwan이 제시한 방법은 ATC-40 방법과 G lkan과 Kowalsky 방법의 중간 값을 예측함으로써, 비교적 정확한 값에 가까운 최대 변위를 산출하였다. 그리고, Kowalsky 방법은 항복 후 강성비에 따라 등가감쇠비를 음수로 산정함으로써 예측 값을 제시하지 못하는 경우가 있음을 확인하였다.
In the capacity spectrum method (CSM), the peak response of an inelastic system under a given earthquake load is estimated transforming the system into the equivalent elastic one. This paper presented estimating the peak inelastic response is evaIuated by the CSM. The equivalent period and damping are calculated using the ATC-40, Gülkan, Kowalsky, and Iwan methods, and the performance points are obtained according the procedure B of ATC-40. Analysis results indicate that the ATC-40 method generaIly underestimates the peak response, while the Gülkan and Kowalsky methods overestimate the responses. The Iwan method produces the values between those by the ATC-40 method and the Gülkan and Kowalsky methods, and estimates the reponses relatively closer to the exact ones. Further, it is found that the Kowalsky method gives the negative equivalent damping ratios depending on the hardening ratios, and thereby can not be used to estimate the responses in some cases.
단층에 근접한 지진동에 대하여 성능이 저하되는 단자유도계의 변위응답에 대하여 연구하였다 5% 의 감쇠비를 갖는 세단계의 성능저하시스템을 5개의 단층에 근접한 지진동에 대하여 해석하였다 해석결과로부터 성능저하시스템의 비탄성 변위응답은 비저하시스템에 비하여 큰 값을 나타냄을 알 수 있었다 또한 성능저하 특성이 증가할수록 변위응답은 커지는 경향이 있다 이러한 변위증폭은 구조물의 고유주기 강도와 성능저하특성에 영향을 받으며 짧은 주기영역에서는 큰 값을 나타내며 긴 주기영역에서는 변위증폭이 거의 발생하지 않는다 단층에 근접한 각각의 지진동에 대한 변위증폭의 최대값은 1초 보다 작은 주기영역에서 비저하시스템의 4배 정도이다 변위증폭계수의 평균값은 짧은 주기영역에서는 2의 값을 가지면 구조물의 고유주기가 길어질수록 1에 수렴해 감을 알 수 있었다. Q
대형 시스템의 건전성 평가를 위한 동적 재하시험에 있어서 변위를 측정하는 것보다 가속도를 측정하는 것이 수월하나 대부분의 공학적 기준은 응력과 비례관계를 지니는 변화를 기준으로 하고 있다. 본 연구에서는 시스템의 재하시험시 측정된 가속도신호를 이용하여 변위응답을 산정하는데 그 목적을 두고 적분을 위한 신호처리시 발생되는 문제점을 정상상태 및 천이영역에 대하여 규명하였다. 기존의 연구에서 고려하지 못하였던 초기조건의 항을 도입함으로써 시간영역의 적분과 주파수영역의 적분결과가 일치함을 해석적으로 입증하였으며 이동하중을 받는 보의 동적거동에 대하여 제시된 타당성을 검증하였다.
The contact displacement sensors that are currently becoming popular in the shaking table tests are limited depending on their use environments; thus, the reality is that each equipment appears impractical considering its effectiveness and applicability. Therefore, in this study, to verify an algorithm for measuring the displacement responses of a structure using the line detection in the shaking table test, the test was conducted on a reinforced concrete frame.