        In this study, the operating performance of the heat pump dryer using the PF heat exchanger was experimentally studied. The capacity, COP, drain, SMER and operating status of the cooling cycle of the heat pump dryer were investigated according to the temperature, relative humidity and flow rate of the indoor air. Heat pump dryers are refrigerant-air system. For the dryer performance experiment, an air enthalpy calorimeter was used. From the experimental results, as the temperature, relative humidity, and flow rate of the inlet air increased, the capacity, COP, drain, SMER of the dryer increased. The change in the performance of the dryer was most affected by temperature. The P-h diagram of the cooling system showed that the operation status of the dryer was greatly affected by the indoor temperature. In addition, the SMER of the dryer showed a drying performance of about 3.38 kg/kWh or more within all experimental ranges.
        4,000원
        2.
        2023.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        방충설비는 선박의 접안 및 양하역 과정에서 선박의 충격력을 흡수하여 선박과 접안시설을 모두 보호하는 매우 중 요한 역할을 수행한다. 하지만 이에 대한 최근 연구 및 설계 최적화의 노력이 매우 부족해 보인다. 이에 본 논문은 국내 항만 설계기준에서 제시하고 있는 방충재 설계에 사용되는 선박 접안에너지 산정식을 개선, 보완하기 위하여 연구를 수행하였다. 접 안에너지 산정과정에서 선박 및 접안시설의 조건을 고려하기 위하여 적용되는 영향계수의 변화에 따른 영향을 분석하였으며, 이 과정에서 국내외 설계코드에서 제시하고 있는 산정방법과 최신 선박제원, 국내 설계결과가 활용되었다. 분석에는 최신 선박 의 표준제원과 국내에서 실시된 실제 설계결과가 적용되었다. 그 결과, 국내 항만 설계기준에서 제시하고 있는 영향계수 결정방 법은 선박과 접안시설의 조건을 최적으로 반영하기에는 부족하며, 접안에너지가 20%이상 크게 산정되어 방충재 선정과정에서 과다 설계가 야기될 수 있는 것으로 판단되었다. 이에, 국내 항만 설계기준에서 제시하고 있는 영향계수를 선박 및 접안여건을 고려하여 설계할 수 있도록 최적화된 방법을 제시하였다.
        4,200원
        3.
        2022.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Based on the nonlinear static analysis and the approximate seismic evaluation method adopted in “Guidelines for seismic performance evaluation for existing buildings, two methods to calculate strength demand for retrofitting individual structural walls in unreinforced masonry buildings are proposed.” The displacement coefficient method to determine displacement demand from nonlinear static analysis results is used for the inverse calculation of overall strength demand required to reduce the displacement demand to a target value meeting the performance objective of the unreinforced masonry building to retrofit. A preliminary seismic evaluation method to screen out vulnerable buildings, of which detailed evaluation is necessary, is utilized to calculate overall strength demand without structural analysis based on the difference between the seismic demand and capacity. A system modification factor is introduced to the preliminary seismic evaluation method to reduce the strength demand considering inelastic deformation. The overall strength demand is distributed to the structural walls to retrofit based on the wall stiffness, including the remaining walls or otherwise. Four detached residential houses are modeled and analyzed using the nonlinear static and preliminary evaluation procedures to examine the proposed method.
        4,000원
        4.
        2020.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Analysis of the 2016 Gyeongju earthquake and the 2017 Pohang earthquake showed the characteristics of a typical high-frequency earthquake with many high-frequency components, short time strong motion duration, and large peak ground acceleration relative to the magnitude of the earthquake. Domestic nuclear power plants were designed and evaluated based on NRC's Regulatory Guide 1.60 design response spectrum, which had a great deal of energy in the low-frequency range. Therefore, nuclear power plants should carry out seismic verification and seismic performance evaluation of systems, structures, and components by reflecting the domestic characteristics of earthquakes. In this study, high-frequency amplification factors that can be used for seismic verification and seismic performance evaluation of nuclear power plant systems, structures, and equipment were analyzed. In order to analyze the high-frequency amplification factor, five sets of seismic time history were generated, which were matched with the uniform hazard response spectrum to reflect the characteristics of domestic earthquake motion. The nuclear power plant was subjected to seismic analysis for the construction of the Korean standard nuclear power plant, OPR1000, which is a reactor building, an auxiliary building assembly, a component cooling water heat exchanger building, and an essential service water building. Based on the results of the seismic analysis, a high-frequency amplification factor was derived upon the calculation of the floor response spectrum of the important locations of nuclear power plants. The high-frequency amplification factor can be effectively used for the seismic verification and seismic performance evaluation of electric equipment which are sensitive to high-frequency earthquakes.
        4,000원
        5.
        2019.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Most school buildings consist of reinforced concrete (RC) moment frames with masonry infills. The longitudinal direction frames of those school buildings are relatively weak due to the short-column effects caused by the partial masonry infills and need to be evaluated carefully. In ‘Manual for Seismic Performance Evaluation and Retrofit of School Facilities’ published in 2018, response modification factor of 2.5 is applied to non-seismic RC moment frames with partial masonry infills, but sufficient verification of the factor has not been reported yet. Therefore, this study conducted seismic performance evaluation of planar RC moment frames with partial masonry infills in accordance with both linear analysis and nonlinear static analysis procedures presented in the manual. The evaluation results from the different procedures are compared in terms of assessed performance levels and number of members not meeting target performance objectives. Finally, appropriate response modification factors are proposed with respect to a shear-controlled column ratio.
        4,300원
        6.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 간편화된 소성 접선 곡선을 적용하여 노측용 가드레일 시스템의 충격 성능을 평가하기 위한 유한요소 충돌해석을 수행하였다. 충돌해석은 Cowper-Symond 모델을 적용하여 변형률 속도 영향에 대한 결과의 정확성을 향상시켰다. 수치 해석 결과는 소성 접선 곡선을 고려한 향상된 모델의 중요성을 보여준다. 다양한 매개변수에 대한 해석 결과는 서로 다른 모델에 대하여 동적 응답 및 탑승자 안전지수를 중심으로 비교 검증하여 도출하였다.
        4,000원
        7.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 마찰력에 따른 TMD의 작동-정지조건과 각 조건에 따른 운동방정식을 정리하고, TMD의 마찰계수가 풍진동 제어성능에 미치는 영향을 수치해석을 통하여 확인하였다. 일반적인 하중과 달리 풍하중은 크기와 방향의 변화가 크기 때문에 TMD 는 마찰력에 의하여 작동-정지상태를 반복하게 되므로, TMD의 마찰계수를 주요 변수로 설정하였다. 또한 외부하중의 크기, 구조물의 진동수, TMD의 질량비도 매개변수로 설정하여 TMD의 제진성능에 대한 영향을 파악하고자 하였다. 자유진동, 조화강제진동, 풍진동에 대한 수치해석의 결과, 외부하중의 크기가 작고, 구조물의 진동수가 낮을수록 마찰계수에 의한 TMD의 제진성능의 손실이 커질 수 있음을 확인하였으며, 초고층 건물에 대한 TMD 설계시 마찰계수의 영향을 반드시 고려하여야 할 것으로 판단된다.
        4,000원
        11.
        2008.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 높은 지진의 위험이 내재된 지역에 위치한 3층, 9층 그리고 20층 철골 모멘트저항골조에 대한 반응수정계수와 주기의 영향을 평가하기 위한 것이다. 각 구조물들은 IBC 2000과 KBC 2005에서 제시하고 있는 8의 반응수정계수로 설계되었고 건물에 기대되는 최소의 성능과 최대의 성능을 평가하기 위해서 상한범위와 하한범위의 설계가 고려되었다. 또한 반응수정계수에 대한 영향을 조사하기 위하여 4개의 다른 반응수정계수들이(9, 10, 11, 12) 각 구조물에 대하여 적용되었고 각 구조물의 고유주기 값 외의 4개의 다른 주기를 추가로 적용하여 구조물의 동적거동시 주기에 대한 영향을 조사하였다. 총 150개의 해석모델들은 50년 동안 2%의 초과확률(재현 주기 2500년)을 가진 20개의 지반운동에 대하여 평가되었다. 구조물의 성능평가를 위하여 정적 Pushover와 비선형 시간이력해석이 수행되었으며 구조물의 연성능력을 평가하기 위해서 변위연성요구가 고려되었다. 3층과 9층 구조물은 변위연성요구 값이 비교적 안정적인 거동을 보인 반면 20층 구조물은 동적 불안정성을 야기하는 요소에 의해 민감하게 나타나는 것으로 조사되었다.
        4,000원
        13.
        2002.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        반응수정계수는 구조물의 비탄성 거동을 설계에 반영하고 설계지진력 산정시 설계강도를 탄성범위 이내로 저감시키기 위한 목적으로 사용하고 있다. 그러나 설계코드에서 채택하고 있는 반응수정계수는 과거의 지진피해로부터 관찰된 보편적 구조성능에 기인한 경험치이므로, 주기에 따른 동적성능과 구조 시스템의 구성에 따른 내진성능을 정확히 대변하지 못하고 있다. 본 연구에서는 중간모멘트 연성골조를 대상으로 N2 Method를 이용하여 반응수정계수와 내진성능을 평가하였으며, 그 결과를 미국의 IBC 2000 코드와 비교하여 이론적 타당성을 검증하였다. 해석결과 코드에 제시된 반응수정계수와 잘 부합되는 것으로 나타났으나, 동일한 구조시스템의 경우에도 주기에 따라 비교적 큰 차이를 보였다. 성능목표에 따른 사용성 기준을 설정하여 IDI를 평가한 결과, 설계지진에 대한 성능목표가 건물에 대한 내진성능을 대변하기는 어려우며 PBD(Performance Based Design)에 의거한 합리적인 접근이 필요한 것으로 판단된다.
        4,000원
        14.
        2013.04 서비스 종료(열람 제한)
        The limit state design code for reliability-based design criteria was enacted in January 2012. And, it was necessary to consider new load carrying capacity method for new design code. Therefore, LRFR and ballowable stress design rating was applied to load carrying capacity and compared with the result. In addition, this research consists of ambient vibration measurement, experimental modal analysis, correction of the initial FE model based on the identified modal properties, and estimation of the load carrying capacity using the updated FE model
        15.
        2012.11 서비스 종료(열람 제한)
        The objective of this study is to investigate the elasticity of high performance concrete replacement blast furnace slag. Experimental variables of this study are modulus(100×100mm, 150×150mm). And test results were compared with existing equations.
        16.
        2012.11 서비스 종료(열람 제한)
        In this study, KS F 2438 was used to investigated the modulus of elasticity of high performance concrete (HPC) of replacement fly ash, and test results were compared with existing equations. Korea, America and Japan have to use cylinder specimens by KCI(2011). However, in this study was used cubic specimens and the experimental variable of this study is size of cubic specimens.
        17.
        2005.10 KCI 등재 서비스 종료(열람 제한)
        이 연구는 선박 설계 초기단계에서 선형 변화에 따른 선박 조종성능 추정에 관한 내용을 다루었다. 선박제원을 대표하는 파라메터 그리고 선미형상의 변화를 민감하게 반영할 수 있는 새로운 파라메터를 선정하는 작업을 수행하였다. 이렇게 선정된 파라메터와 유체력 미계수와의 상관관계를 알아보기 위하여 구속모형 실험을 수행하였다. 그 결과 기본적인 선박제원 중 선체 유체력 미계수와 상관도가 높은 파라메터를 가려낼 수 있었다. 또한 선미형상의 새로운 파라메터와 조종성능과의 상관도를 추정할 수 있었다. 또한 이를 활용하여 유체력미계수에 대한 새로운 경험식을 제시하였다. 이를 활용하면, 초기 선형 설계 시 선형변화 및 수정에 따른 조종성능 추정에 활용할 수 있을 것으로 판단된다.