        1.
        2023.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to measure sedimentation status change with the changes in internal pressure for dry chemical extinguishers of various use periods and analyze the suitability of the fire extinguishers' performance criteria. When the internal pressure of the fire extinguisher is 0%, 2 out of 10 new dry chemical powders for the 5 elapsed years were noted to be suitable, including 3 recycled dry chemical powders with 5 elapsed years that were found eligible. One out of 10 new dry chemical powders for 10 elapsed years was shown as suitable. Also, one new dry chemical powder for 13 elapsed years was suitable. When the internal pressure of the fire extinguisher was 50%, all 10 out of 10 new dry chemical powders for 5 years, recycled one with 5 elapsed years, and a new one with 10 elapsed years were found to be suitable, while 9 new dry chemical powders for 13 years were shown as suitable. When the internal pressure of the fire extinguisher was normal, new ones with 5 elapsed years, recycled ones with 5 elapsed years, new ones with 10 elapsed years, and new ones with 13 elapsed years were all 10 out of 10 samples noted as suitable. In summarizing the experiment results, it was found that the sedimentation status, one of the fire extinguisher's physical properties experiments, affects the fire extinguisher's performance criteria rather than the change with use periods.
        4,000원
        2.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study collected powder extinguishers with 6-10 years of elapsed life from January 2012 to January 2017 in market, factory, and apartment areas to experiment with changes in fineness and to examine the characteristics of extinguishing power. First, in the case of ABC powder, 98.3 wt% of the 8-year market area and 98.6 wt% of the 10-year apartment complex were found to be inappropriate in the first, second, and third arithmetic average analysis of the powder extinguisher from 6 to 10 years. That is, the fine distribution and size of the powder extinguishing agent particles should be managed within an appropriate range. It is analyzed that the powder fire extinguisher may experience a change in the fineness of the powder depending on the external environment exposure, placement, management status, and age of use, resulting in a decrease in digestive power or inability to radiate. Second, the fire extinguisher cannot be used in the initial fire suppression depending on the place of deployment, the environment of deployment, the progress of the number of years of use, and maintenance, so it is necessary to strengthen the device that enables fire extinguisher maintenance and inspection. Third, in the manufacturing process, the charging method should also be reviewed in consideration of the conditions of the workplace, the humid season, and the rainy environment.
        4,000원
        4.
        2021.06 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        췌장고형종양의 초음파 내시경(endoscopic ultrasound, EUS) 유도하 조직 검사는 기술적 난이도가 높고 침습적이기 때문에 임상에서의 적절한 사용을 위해 엄격한 권고안을 필요로 한다. 이에 대한소화기내시경학회에서는 췌장고형종양의 초음파 내시경 유도하 조직 검사를 위한 임상진료지침을 개발하기 위해 진료지침 개발위원회를 발족하였다. 권고안의 등급과 개별 권고안의 근거 수준은 2014년 출판된 임상진료지침 개발을 위한 Minds Handbook에서 제시된 체계에 기반하여 평가하였다. 본 진료지침 개발위원회는 초음파 내시경 분야의 전문가 16인과 임상진료지침 개발방법론 전문가 1인으로 구성되었으며, 8개 분야에 걸쳐 총 12건의 근거 기반 권고안을 개발하여 췌장고형종양 진단 시 임상의들이 근거에 기반한 임상적 판단을 할 수 있도록 돕고자 하였다. 본 임상 진료지침은 췌장고형종양에서 초음파 내시경 유도하 조직 검사에 대해 다루고 있으며, 권고안에서는 해당 검사의 적응증, 진단 정확도를 최대화하기 위한 기술적 방법론(예: 바늘의 종류 및 직경의 적절한 선택, 충분한 바늘천자횟수, 조직 획득 기술적 방법론, 검체 처리 방법), 시술 관련 합병증, 그리고 숙련도와 교육에 관련된 문제들에 대해 다루고 있다. 본 진료지침은 외부 전문가의 검토를 거쳤으며, 원고작성 시점까지 보고된 가능한 모든 최신 근거들에 기반하여 최선의 진료 방법을 권고하고 있다. 그러나 모든 임상 상황에 본 진료지침을 일괄적으로 적용할 수는 없으며, 기관의 법적/행정적 상황 및 환자의 개별 임상적 상황과 해당 자원의 가용성 등을 고려하여야 한다. 추후 내시경적 기술의 발전과 이로 인한 변화, 임상에서의 최신 근거를 토대로 본 진료지침이 개정될 수 있다.
        6,000원
        7.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The definition of an apartment is a building more than 5 stories high and which is the standard law. Currently, the number of apartments is increasing much faster than detached houses. Owning an apartment is a normal trend these days. However, the increasing number of apartments has been increasing the number of apartment fires which also has been making social problems. Therefore, this study was conducted for the fire extinguisher among other fire facilities because it is important for initial fire suppression. The research subject is on the fire extinguisher that is in the underground parking lot of 40 apartment complexes which are more than 10 stories. Survey and analysis were conducted for 80 fire extinguishers. There are two fire extinguishers for each apartment. The result of this study is that all installed fire extinguishers are ABC dry chemical type, 92% of them is 3.3kg and that meet the legal height(less than 1.5m). However, the condition such as appearance, inspection, manufactured year, appearance of signs, material of signs, size of signs, etc. was insufficiency. So improvement of law and system that are fire facility construction, maintenance implementation and additional designation of type approval about sign will be needed in my opinion.
        4,000원
        8.
        2014.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Preschoolers are the most effective age to start fire safety education. But, if the education contents are inappropriate, they may form the wrong habit to preschoolers. Many educational contents of fire safety in Korea are not so obvious in the principle and order of priority about what to do during fire and they often contain unnecessary contents to preschoolers such as how to use fire extinguisher. This paper has analyzed fire safety awareness of preschoolers and teachers and, based on the results, has claimed unsuitability of training on how to use fire extinguisher and has suggested the improvement of fire safety education.
        4,000원
        9.
        2011.05 구독 인증기관 무료, 개인회원 유료
        • 현재 조사시 70%이상이 관리 불량 • 이로 인한 화재 발생시 소화기 작동 불능 • 초기 진압 실패ㅡ> 대형화재 • 막대한 피해 손실 발생 • 소화기 관리의 중요성 인식 • 자동화 소화기 관리 시스템 제작
        4,600원
        11.
        2015.04 KCI 등재 서비스 종료(열람 제한)
        Recently, the explosion of powder fire extinguisher led to the replacement of old extinguishers with new ones in Korea. As a result, the amount of waste fire extinguishing agents from discarded fire extinguishers has been increasing. In this study, to determine the recyclability of the fire extinguishing agents, content and leaching test were conducted to identify their health hazards in accordance with the Korean standard method for waste and soil. To this end, nine powders in four new products and five discarded products were sampled from five companies. Analysis of discarded powder of fire extinguishers showed that levels of heavy metals (Pb, Cd, Cr6+,Cr, Hg, Cu, Ni, As, Zn), organic phosphorus, oil, TCE, and PCE were within the levels set out in the Wastes Control Act, the Fertilizer Control Act and the Soil Environment Conservation Act. Only arsenic level in some new and discarded powder of fire extinguisher samples exceeded the acceptable levels as set forth in the Wastes Control Act (1.5 mg/L) and the Soil Environment Conservation Act (25 mg/kg) but within the acceptable arsenic level of 45 mg/kg as set forth in the Fertilizer Control Act. Concentrations of arsenic in the samples ranged from 0.039 to 2.578 mg/L, 6.72 to 38.36 mg/kg. The most commonly used chemical for ABC dry chemical extinguisher is mono-ammonium phosphate, which generally contains up to 0.005% of arsenic and be used as fertilizer. The result confirmed that powder of fire extinguishers could be recycled as fire extinguisher powder or fertilizer as practiced in Japan, USA and UK. But it is necessary to pretreat and meet the regulation of fireextinguisher and fertilizer.
        12.
        1993.12 KCI 등재 서비스 종료(열람 제한)
        Methane production from grain dust was studied using a 3 L laboratory-scale anaerobic plug flow digester. The digester was operated at; temperature of 35, 45, and 55℃ hydraulic retention time(HRT) of 6 and 12 days; and influent concentration(S_0) of 7.8 and 9.0 % total solids(%TS). With ten different operation conditions, this study showed the significant effects of temperature, hydraulic retention time, and influent concentration on methane production, The highest methane-production rate achieved was 1.903 (L methane) /(L digester)(day) at 55℃, 6 days HRT, and S_0 of 7.8 %TS. A total of 3.767 L of biogas per day with a methane content of 50.57% was obtained from this condition. The ultimate methane yield(B_0 was found to be a function of temperature and influent concentration, and was described as : B_0= 0.02907T-0.1263-0.00297(T-10)(%TS), where TS is the total solids in the liquid effluent, and T is temperature(℃). Our results showed that thermophilic condition is better than mesophilic for grain dust stabilization in an anaerobic plug flow digester.