검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 16

        1.
        2024.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we addressed the prevention of fire extinguishing device malfunction caused by noise in the fire detector of automatic fire extinguishing devices applied to mobile equipment such as armored vehicles and tanks. The automatic fire extinguishing system consists of a fire detection unit, an automatic control unit, and a fire suppression unit. In the case of a fire detector, it is a major component of the fire detection unit. Even though no fire occurred during operation in the field, a number of fire extinguisher sprays occurred, and the malfunction of the fire detector, which is a fire detection unit, was reproduced. The cause was identified as noise in the fire detector connector due to vibration and shock that may occur during operation of the mobility equipment. In order to solve this problem, noise generated momentarily from a fire detector is treated as an exception, and when a fire signal is transmitted from the fire detector to the automatic control unit for more than a certain period of time, Software has been improved to enable fire extinguishers to operate. This study analyzed the causes of malfunctions in automatic fire extinguishing devices, which are components of mobile equipment, and derived improvement measures to improve the reliability of automatic fire extinguishing devices.
        4,000원
        2.
        2023.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Combat-armored vehicles were equipped with an automatic-fire-extinguishing system to ensure the safety of the crew and vehicle from fires on the vehicle. When a fire was occurred, the automatic-fire-extinguishing system automatically detects the fire through sensors and detection lines, sprays a fire extinguisher, and notifies the crew visually and audibly. Recently, there had been cases of automatic-fire-extinguishing systems malfunction on combat-armored vehicles. In this study, in order to resolve the automatic-fire-extinguisher's malfunction phenomenon, ground noise and inter-circuit noise generated from the fire detection line were identified, and the resistance connected on the circuit was revised to remove noise. As a result of resistance revision, the noises was eliminated and the electromotive force difference between input circuits was made constant, thereby improving the malfunction of the automatic-fire-extinguishing system. By applying the result, it was confirmed that the control device sensed a temperature similar to the actual temperature on actual vehicles, and it was confirmed that the automatic-fire-extinguishing system's malfunction phenomenon was not founded in the field vehicles after then.
        4,000원
        9.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A core device of foam system is the in-line eductor and it is the device to mix the foam liquid into liquid solution proper to the use density and the mixture ratio must be kept regularly regardless of changing fluid condition of the front and rear end of the in-line eductor. However, if the flux of the pressurized water changes, the mixture ratio is not kept regularly, and so it becomes a cause which a performance of fire-extinguishing deteriorates in discharging foam liquid. I devise a method to improve it that the metering orifice type in-line eductor is improved into the metering venturi type in-line eductor, the fluctuation of the mixture ratio to the flux change of the pressurized water is minimized and the performance of fire-extinguishing is kept regularly. As this method is simple in its structure and can be designed at a low cost, it helps for maintenance as well. In the future, it seems to need the research for the metering nozzle type in-line eductor in the future.
        4,000원
        10.
        2016.11 서비스 종료(열람 제한)
        혐기성소화는 환경에 민감하기 때문에, 이에 항상 일정한 환경을 유지해 주는 것이 혐기성소화의 열쇠라고 할 수 있다. 이번 연구에서는 혐기성소화조의 온도를 중온소화영역(30~37℃)을 유지할 수 있도록 해주는 장치를 개발, 설치하여 이의 효용성에 대한 연구를 진행하였다. 설치대상 혐기성소화조는 1m³의 부피를 가진다. 여기에 가온은 총 2가지의 방식으로 진행하였다. 첫 번째는 호기소화열을 이용하였고, 두 번째는 태양열을 이용하여 생산된 온수를 이용하였다. 온수를 이용하여 혐기성소화조를 가온키 위해 태양열을 집열하는 진공관과 온수탱크를 설치하였다. 그리고 온수탱크와 혐기성소화조의 하단부를 자켓으로 연결하여 가온할 수 있도록 하였다. 호기소화열의 제어는 무리가 있어, 온수를 제어하여 혐기성소화조의 온도를 제어하였다. 온도를 제어하기 위해 온수탱크와 혐기성소화조, 진공관에 온도센서를 중앙제어장치와 연결하여 설치하였다. 중앙제어장치에서는 온도센서로부터 측정한 온도를 이용하여 연산을 진행하였다. 진공관의 온도가 온수탱크보다 10℃가 높을 때 온수를 순환시켰고, 온수탱크의 온도가 45℃를 넘고 혐기성소화조가 35℃ 미만이 되었을 때 온수를 순환시켰다. 실험결과 태양열온수장치를 이용하기 전 혐기성소화조, 호기성소화조, 실내의 평균 온도는 각각 33, 49.8, 34.1℃였고, 태양열온수장치를 이용했을 때 혐기성소화조, 호기성소화조, 실내의 평균온도는 각각 33.1, 44, 22.1℃로 측정되었다. 태양열온수장치를 이용했을 때의 호기성소화조의 온도와 실내의 평균온도가 장치를 이용하지 않을때의 호기성소화조와 실내의 평균온도보다 훨씬 낮음에도 불구하고 혐기성소화조의 온도가 더 높게 측정된 것은 태양열온수장치의 가온효과가 고무적으로 보인다고 사료된다.
        11.
        2015.06 서비스 종료(열람 제한)
        A 31-year-old woman was transferred because of dyspnea that occurred immediately after cesarean section. Initial echocar-diography showed akinesia in apex to mid left ventricular (LV) wall with severe LV systolic dysfunction, which was pre-sumed to be stress-induced cardiomyopathy. Because the patient developed cardiogenic shock, we initially planned on inser-tion of an intra-aortic balloon pump. However, due to aggravation of cardiogenic shock and pulmonary edema, we had to resort to extracorporeal membrane oxygenation (ECMO) for cardiopulmonary support. In addition, an LV pigtail catheter was applied for decompressing the LV. Finally, she was successfully weaned from ECMO after recovery of LV function.
        12.
        2014.11 서비스 종료(열람 제한)
        본 연구는 하수슬러지의 플록상태를 파악할 수 있는 응집제 자동투입장치를 탈수기 전단에 장착하여 하수슬러지(소화슬러지, 농축슬러지) 플록상태에 따른 고분자 응집제 주입량을 다르게 함으로써 탈수케이크의 함수율 저감 및 응집제 사용량 절감, 탈수여액의 수질개선 등을 평가하는데 그 목적이 있다. 응집제 자동투입장치를 B시 N하수처리장 소화슬러지 및 S하수처리장 농축슬러지에 적용한 결과 고속회전 및 응집제 분사를 통한 균일한 플록이 형성됨에 따라 탈수케이크 함수율 및 응집제 주입율 저감효과를 나타내었다. 하수슬러지의 탈수실험 결과 소화슬러지에 대한 고분자 응집제의 적정주입율은 12%로 나타났으며, 이때의 비저항계수(SRF)는 1.11×1011 m/kg으로 나타났다. 또한, 농축슬러지에 대한 고분자 응집제의 적정주입율은 16%로 나타났으며, 이때의 비저항계수(SRF)는 1.68×1011 m/kg으로 나타났다. 또한 응집제 자동투입장치의 회전속도와 유입 하수슬러지량 대비 고분자 응집제 주입율과의 상관관계를 평가한 결과 회전속도를 900~1,200 rpm의 범위 내에서 운전시 플록형성이 양호하게 나타났다. 기존 시스템 대비 응집제 자동투입장치의 경제성 평가 결과 N하수처리장 및 S하수처리장의 경우 각각 연간 263,542,490원 및 42,174,700원으로 산출되었으며, 시설투자비 회수기간은 각각 2.3년 및 7.1년으로 나타났다. 따라서, 하수처리장 탈수기 전단에 응집제 자동투입장치를 적용함으로써 함수율 및 약품주입량 저감 뿐만 아니라 중앙제어실을 통한 실시간 모니터링이 가능하므로 인력감축 유도 및 공정자동화에도 기여할 수 있을 것으로 판단된다.
        13.
        2014.11 서비스 종료(열람 제한)
        혐기성소화기술은 지난 백여년 이상동안 많은 연구자들에 의하여 연구되어 온 전통기술로서 최근 지구온난화 문제가 전 세계적인 이슈로 부상하면서 새롭게 조명 받고 있다. 그러나, 혐기성소화기술은 여전히 메탄생성균의 느린 성장속도와 환경인자에 대한 민감성에 기인하여 20일 이상의 긴 체류시간을 필요로 하고 유기물감량율이 낮으며, 운전조건이 까다롭다는 단점을 지니고 있다. 최근 들어 환경생물전기화학자들에 의해 연구되기 시작한 생물전기화학기술(Bioelectrochemical technology)을 혐기성소화공정에 활용하면 메탄생성반응과 가수분해반응을 크게 촉진시킬 수 있어 전통적인 혐기성소화기술의 단점들이 상당 부분 극복할 수 있다. 혐기성소화공정에 활용하는 생물전기화학기술은 소화조 내에 설치하는 산화전극과 환원전극으로 이루어지며, 외부회로에 의하여 서로 연결된 산화전극과 환원전극 사이에 외부전원을 이용하여 전압을 인가하여 일정한 전위차가 유지되도록 한 미생물전해전지(Microbial electrolysis cells, MECs)의 형태이다. 혐기성소화조에서 전기적으로 활성을 가진 미생물들은 유기물이나 유기산을 빠른 속도로 분해하여 전자와 양성자를 생성하며, 전자는 산화전극으로 전달된 뒤 외부회로를 통하여 환원전극으로 이동한다. 환원전극의 표면에서는 전자와 양성자 또는 전자와 양성자 및 이산화탄소가 반응하여 수소나 메탄과 같은 바이오가스가 생성된다. 본 연구에서는 완전혼합형 혐기성소화조에 생물전기화학장치가 설치된 반응조 (Bioelectrochemical anaerobic digestion, BEAD)을 이용하여 수리학적 체류시간에 따른 PTA 폐수의 처리특성을 평가하였다. PTA (purified terephthalic acid) 폐수는 A 산업에서 채취한 것으로서 COD 값이 약 6,000-8,000mg/L였으며, 주요 구성성분은 terephthalic acid, p-toluic acid, benzoic acid, acetic acid 등이었으며, pH는 5-6이었다. 먼저, 실험에 사용한 산화전극 및 환원전극은 흑연직물 섬유의 표면에 탄소나노튜브를 초음파분산법으로 고정하여 제작하였다. 교반기가 설치된 유효부피 15L의 원통형 혐기성 소화조에 산화전극과 환원전극을 각각 설치하였으며, 산화전극과 환원전극 사이에 0.3V의 전압을 인가하였다. 하수슬러지를 이용하여 운전 중인 생물전기화학장치가 설치된 혐기성소화조에서 유출 슬러지를 초기 운전을 위한 식종균으로 사용하였으며, PTA 폐수를 1일 1회 정량 주입하여 수리학적 체류시간을 20일로 유지하였다. 소화조가 안정화되었을 때 수리학적 체류시간을 단계적으로 10일, 5일, 2.5일 그리고 1.25일 까지 변화시키면서 총 바이오가스발생량 및 메탄함량, COD 제거율과 전류의 변화 등을 관측하였다. 생물전기화학장치가 설치된 혐기성소화조의 COD 감량율은 수리학적 체류시간에 관계없이 약 60%로서 보였으며, 바이오가스의 메탄함량(%)은 80% 이상을 유지하였다. 그러나, 메탄발생량은 수리학적 체류시간의 감소에 따른 유기물 부하율 증가에 비례하여 증가하였다. 그러나, 외부회로의 전류와 메탄가스 발생량으로부터 계산한 쿨롱효율은 수리학적 체류시간이 감소에 따라 오히려 증가하였다. COD 제거율, 바이오가스의 메탄함량 및 메탄가스발생량으로 평가한 생물전기화학장치가 설치된 혐기성소화공정의 안정성은 수리학적 체류시간 20일부터 1.25일의 범위에서 영향을 받지 않았다.
        14.
        2014.05 KCI 등재 서비스 종료(열람 제한)
        The purpose of this study was to improve low digestibility in anaerobic digestion facility of the sewage treatment plant. To perform this research, sludge digestion and digestion gas purification facilities in sewage treatment plant was applied. In the result of this study, it was very effective for sludge reduction from the improvement of digestive efficiency. In addition, it was confirmed that high purity CH4 (methane) was produced. This results can be useful as basic data to improve the low digestibility in anaerobic digestion processes.
        15.
        2013.11 서비스 종료(열람 제한)
        본 연구는 부산광역시 하수슬러지 처리공정 중 탈수기에 유입되는 배관부에 하수슬러지의 플록상태를 파악할 수 있는 응집제 자동주입장치를 장착하여 하수슬러지 플록상태에 따른 적정 응집제 주입량을 다르게 함으로써 탈수효율 향상 및 응집제 사용량을 감소시키고, 나아가 하수슬러지의 건조효율을 증가시키는데 그 목적이 있다. Pilot-scale 응집제 자동주입장치는 B시 소재 N하수처리장의 원심탈수기 전단에 설치하여 2013년 8월 7일 ~ 16일(10일간)동안 운전하였다. 또한, 응집제 자동투입장치의 설치시 운전상의 문제 발생시에 대비하여 bypass관을 설치하여, 기존 시스템으로 전환이 용이할 수 있도록 설계하였다. 고분자 응집제 주입율은 기존 시스템에서 운영하고 있는 유입슬러지량 대비 고분자 응집제 주입율인 14%를 기준으로 운전을 실시하였으며, 응집제 주입율을 11%에서 9%까지 점차적으로 낮추어 가면서 적정 운전조건을 찾고자 하였다. 응집제 자동투입장치를 원심탈수기 전단에 적용한 결과 고속회전 및 응집제 분사를 통한 균일한 플록이 형성됨에 따라 탈수케이크 함수율 및 응집제 주입율 저감효과를 나타내었다. 기존 시스템 대비 응집제 자동투입장치의 운전조건별(DS-P(11%), DS-P(10%) 및 DS-P(9%)) 탈수케이크의 함수율은 기존 함수율 82.4%에서 각각 80.6(저감량 1.8%), 80.9(저감량 1.5%) 및 81.5%(저감량 0.8%)의 높은 탈수효율을 나타내었다. 또한, 응집제 저감율은 DS-P(11%), DS-P(10%) 및 DS-P(9%)에서 각각 21.4, 28.6 및 35.7%를 나타내었다. 또한, 기존 시스템(DS-P(14%); COD 179.2 mg/L, SS 139.3 mg/L) 대비 응집제 자동투입장치의 운전조건별(DS-P(11%), DS-P(10%) 및 DS-P(9%)) 탈수여액 중 COD 및 SS의 농도는 각각 66.2, 76.4, 81.5 mg/L 및 12.0, 19.3, 55.6 mg/L를 나타내었다. 따라서, 하수처리장 탈수기 전단에 응집제 자동주입장치를 적용함으로써 함수율 및 약품주입량 저감 뿐만 아니라 인력감축 유도 및 중앙제어실을 통한 실시간 모니터링이 가능하므로 공정자동화에도 기여할 수 있을 것으로 판단된다.