        1.
        2024.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The current study investigates the seismic performance of shear-dominant RC columns retrofitted with iron-based shape memory alloy (Fe SMA). Three RC columns with insufficient transverse reinforcement were designed and fabricated for lateral cyclic loading tests. Before testing, two specimens were externally confined with carbon fiber-reinforced polymer (CFRP) sheets and self-prestressed Fe SMA strips. The test results showed that both CFRP and Fe SMA performed well in preventing severe shear failure exhibited by the unretrofitted control specimen. Furthermore, the two retrofitted specimens showed ductile flexural responses up to the drift ratios of ±8%. In terms of damage control, however, the Fe SMA confinement was superior to CFRP confinement in that the spalling of concrete was much less and that the rupture of confinement did not occur.
        4,000원
        2.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Fiber-reinforced polymer (FRP) exhibits superior tensile strength and corrosion resistance compared to steel but has a lower elasticity. Recently, researchers have addressed this by proposing composite sections of FRP and concrete. To ensure the intended composite behavior, these FRP–concrete sections should exhibit sufficient stress transfer between the two elements through a shear connection. Herein, various shear connection methods were proposed to improve the composite behavior of glass fiber–reinforced polymer (GFRP) plates and concrete. Through push-out tests, the behavior characteristics of the prepared specimens were analyzed. The findings confirm that an FRP shear key (FSK) with a small cross-section resists high shear stresses, making it suitable for sections vulnerable to damage from bolt drilling. Additionally, combining an FSK with bolts as shear connectors on a GFRP plate proves beneficial in preventing the fracture of the plate and improving the shear resistance.
        4,000원
        3.
        2023.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, considering the expansion/contraction behavior of the upper structure at all times and the abnormal behavior of the receiving friction elements that allow horizontal movement during earthquakes, a port receiving test body simulating the protrusion of the friction elements was created and the modulus performance was evaluated. In order to confirm the influence of the friction element's projection, the friction element's degree of separation was divided into four stages, and the shear behavior of the test specimen and the friction coefficient were confirmed. As a result of the experiment, it was found that the friction load increases as the protrusion degree of the friction element increases. On the other hand, as the degree of protrusion of the coefficient of friction increases, the coefficient of friction also increases. It was confirmed that damage to the friction elements during use increases the coefficient of friction, hinders smooth expansion and contraction of the upper structure, and causes stress concentration at the fixed-end support.
        4,000원
        4.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        콘크리트 바닥판의 파손 등으로 인하여 강합성 거더 교량의 생애주기가 짧아짐에 따라 프리캐스트 바닥판을 사용한 모듈화 공법에 대한 연구가 활발히 진행되고 있으나, 바닥판의 해체 시 발생하는 분진 및 소음으로 인한 환경적 측면에 대한 연구는 미흡한 실정이다. 본 연구는 기존 용접 스터드 볼트를 대체할 수 있는 볼트 접합 전단연결재의 성능을 검증하기 위하여 정적강도 실험 및 피로강도 실험을 수행하였다. 실험결과 200만 회 피로하중에 대하여 실험체의 균열 및 파괴 양상은 관측되지 않았으며, 이후 실시한 잔류강도 실험 또한 정적강도 실험과 동일한 것으로 확인되었다.
        4,000원
        5.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 경주, 포항에 연이은 지진 발생으로 인하여 내진설계에 관심이 높아지고 있다. 다가구주택 필로티기둥은 수직 비정형 시스템으로 상,하부층의 강성 차이로 인하여 지진 발생 시 막대한 피해가 예상되기 때문에 다가구주택 필로티기둥의 내 진보강이 필요하다. 그러나 민간 소유인 다가구주택의 경우 막대한 비용과 시간으로 인하여 보강이 어려운 실정이다. 이에 따 라, 복합섬유패널로 에폭시 접착제 미사용으로 건식시공이 가능한 전단보강공법을 제안하고자 한다. 본 연구에서는 복합섬유패 널 보강 유무에 따른 내진보강공법의 전단내력을 실험을 통하여 검증하였고, 에폭시를 사용하지 않아 일체화 거동을 하지는 않 지만 복합섬유패널의 영향으로 전단내력은 1.46∼1.49배 증가하는 것으로 평가되었다. 따라서 다가구주택 필로티기둥의 내진보 강효과가 있을 것으로 판단된다.
        4,000원
        6.
        2022.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 초고강도 콘크리트판, 그라우팅 및 모체 콘크리트 내에 후크와 스터드로 연결한 합성접합부의 전단 실험 을 수행하고 그 거동을 파악하고자 한다. 압축강도 35 MPa, 50 MPa 및 90 MPa 그라우팅의 강도, 4종류의 전단연결재 배치를 실험변수로 총 12개의 시험체를 제작하였다. 합성접합부의 전단력은 그라우팅 콘크리트의 압축강도에 따라 비례적 관계를 가지 고 있다. 휨모멘트가 지배적인 힘이 아니고 면적이 크며 서로 다른 시기에 콘크리트를 친 경계면 합성체에서 콘크리트 전단력 은 무시할 정도 크기가 아니다. 콘크리트 모체 압축강도보다 그라우팅의 압축강도가 크다면 접합부에서 콘크리트 전단력이 유 의미하게 크며 전단연결재를 병용하면 더 큰 전단력을 얻을 수 있다.
        4,000원
        7.
        2022.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        다가구주택 필로티기둥은 전이구조 형식으로 되어 있어 지진하중에 대하여 전단파괴가 발생하기 쉽다. 이에 따라 내 진설계기준은 강화되고 있지만 이전에 지어진 건축물의 경우 내진보강이 필요한 실정이다. 하지만 기존 습식 공법의 경우 시간 적, 경제적 부담이 크기 때문에 내진보강이 잘 이루어지지 않는다. 따라서 모서리앵글과 CN복합섬유패널을 활용하여 DIY 시공 이 가능한 전단보강공법을 제안하고자 하며 본 실험에서 CN복합섬유패널의 전단성능을 평가하고자 한다. 볼트 연단거리 및 앵 글의 재질을 변수로 설정하여 실험한 결과, 볼트 연단거리가 가까울수록 각형띠판 래티스기둥의 전단내력이 증진되는 것을 확 인하였으며 슬리브 볼트는 고장력 볼트에 비하여 현저히 내력이 저하되어 CN복합섬유패널을 평가하기가 어려웠다. 또한, 알루 미늄앵글은 강재앵글에 비하여 내력은 낮지만 연성능력이 좋은 것으로 평가되었고, 강재앵글은 상대적으로 강성이 크기 때문에 CN복합섬유패널에 주는 영향이 미미한 것을 확인하였다. 이를 실용화하기 위해서 구체적으로 앵글의 크기와 볼트 연단거리를 변수로 설정하여 실험을 수행해야 할 것으로 판단된다.
        4,000원
        9.
        2021.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 건축물의 보수보강 및 리모델링 시 구조부재를 부착하거나 고정하는 데 있어서 시공의 유연성 및 용이성으로 후설치 확장앵커의 사용량이 점점 증가하고 있는 실정이다. 본 연구에서는 현장에서 비교적 용이하게 시공할 수 있는 후설치 확장앵커를 대상으로 비균열 무근콘크리트에 매입한 확장앵커의 연단거리 및 앵커간격를 변수로 한 전단실험을 통하여 확장앵 커의 전단내력과 하중-변위관계를 분석하였다. 실험결과 연단거리 및 앵커간격에 비례하여 일정비율로 전단내력이 상승하였으며, 파괴모드는 강재앵커 파괴 및 콘크리트 파괴로 각각 나타났다. 그리고 실험결과를 ACI318-19 및 CCD설계기준과 비교분석 하였으며, 향후 보다 합리적인 후설치 확장앵커의 최적설계를 위한 기초자료를 제시하고자 한다.
        4,600원
        10.
        2021.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        After the manual shutdown of the Wolseong nuclear power plant due to an earthquake in Gyeongju in 2016, anxiety about the earthquake safety of nuclear power plants has become a major social issue. The shear wall structure used as a major structural element in nuclear power plants is widely used as a major structural member because of its high resistance to horizontal loads such as earthquakes. However, due to the complexity of the structure, it is challenging to predict the dynamic characteristics of the structure. In this study, a three-story shear wall structure is fabricated, and the in-structure response characteristics of the shear wall structure are evaluated through shaking table tests. The test is performed using the Gyeongju earthquake that occurred in 2016, and the response characteristics due to the domestic earthquake are evaluated.
        4,000원
        11.
        2021.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 육상 기원 조립질 하상 퇴적물의 높은 이동성에 영향을 미치는 전단과 파쇄특성을 조사하기 위하여 링전단실험을 수행하였다. 평균 입경 6 mm 자갈에 대하여 링전단시험장치를 사용하여 전단시간(shear time)과 전단속도(shear velocity)에 따른 전단-변형률 역학특성과 입자파쇄 특성을 조사하였다. 특히 배수(장시간 전단)와 비배수(단시간 전단)조건을 고려하기 위하여 초기 전단속도(0.01→0.1→1 mm/sec와 0.1→0.01→1 mm/sec)에 따른 링전단실험을 수행하였다. 실험결과에 따르면, (i) 배수와 비배수조건 모두에서 입자파쇄 특성이 확인되었지만, 비배수조건에서 상대적으로 큰 전단저항을 받는 것으로 나타났다. (ii) 배수조건에 관계없이 수중 자갈의 초기 전단속도는 전단응력-전단변형률 관계곡선을 결정하는 중요한 요인으로 나타났다. (iii) 입자파쇄는 평균 입경에 영향을 받으며 사용된 수중 자갈은 상대적으로 큰 입자파쇄 특성을 보였다. 그리고 (iv) 전단응력 결정에서 가장 크게 영향을 미치는 영향인자는 전단시간과 초기 전단속도임을 확인할 수 있었다. 결론적으로 모래와 자갈을 다량 함유한 조립질 하상 퇴적물은 입자-입자 간 상호 접촉, 마모, 맞물림, 마찰 등의 물리적 이동과정을 통해 입자파쇄와 세립토 함량이 증가되고 이러한 현상은 하상 퇴적물의 고유동성을 초래하는 원인이 되는 것으로 판단된다.
        4,200원
        14.
        2021.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The U-flanged truss hybrid beam is a new composite beam made by pouring concrete into the U-flanged truss beam. In this study, an experimental study was performed to verify the shear capacity of U-flanged truss hybrid beams with the newly developed end reinforcement details. For all specimens, the maximum shear strength was determined by shear failure of concrete in the loading point The detail reinforced with stirrups at the end zone can exhibit the greatest shear strength, but the method of reinforcing the end zone using vertical steel plates, which is a relatively easy method to manufacture, is considered to be the most effective detail in terms of shear strength and ductility. Also, in the case of U-flanged truss hybrid beams reinforced with vertical steel plates at the end zone, the shear strength can be evaluated on the safety side by using the Korea Design Standard formula.
        4,000원
        15.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        FRP 보강이 RC 기둥의 내진성능에 미치는 효과를 평가하고자 다양한 실험 연구가 수행되어 왔다. 그 중 많은 연구가 휨지배를 받는 원형 단면 RC 기둥의 거동에 초점을 맞추었다. 단면 형태가 FRP 보강에 의한 구속효과에 영향을 주기 때문에, 단면 형태에 따라 보강효과 및 최종손상 양상이 다를 수 있다. 또한, 기존 RC 기둥 중 일부는 현재의 구조기준을 만족하지 못하는 설계로 인하여 취성적인 파괴 모드인 전단 파괴가 발생할 것으로 여겨진다. 이 두 가지 조건을 고려하여, 현무암 섬유를 함유한 FRP 시트와 복합섬유 패널로 보강한 정사각형 단면을 가진 짧은 RC 기둥의 전단 거동을 살펴보기 위하여 반복하중 실험을 수행하였다. 실험 결과에서 전체적인 전단 거동의 개선을 확인하였으며, 이러한 경향은 모서리 부분에서 심각한 손상이 발생할 때까지 유효하였다.
        4,000원
        17.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, an experimental study was carried out to evaluate the bond shear performance according to the shear connector between the glue-laminated timber and steel interface. Ten block shear specimens were fabricated according to the configuration of the adhesive surface of wood and steel. In addition, four test specimens were produced according to the main variable shape of the wood-concrete shear connector. As a result of the block shear test, the shear strength of the steel-wood adhesive is shown to have a shear performance greater than the wood-wood shear strength. As a result of the push-out test according to the shape of the shear connector, the shear strength increased linearly with the attachment area. The complete composite behavior between the glued-laminated timber and the steel can be secured.
        4,000원
        18.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The push-out tests have been conducted on the specimens which consist of the steel beam with U-shape section and the continuous cap-type shear connector. Existing formulas for the elevation of shear connector capacity were investigated on the basis of test results. The shear capacities of continuous cap-type shear connectors distinctly declined as the diameters of side-hole in the shear connector increased. The rebars through side-hole for the transverse reinforcement improved the shear capacity of continuous cap-type connector by 20 to 30 percent. It was not feasible to obtain the appropriate capacity values of continuous cap-type shear connectors made of thin steel plate like those of in this study, using the existing formulas. The new formula for reflecting the shear strength of penetrative bars was proposed based on the shear equation of Eurocode 4. The slip capacities of continuous cap-type shear connectors were shown to exceed the limit value of 6mm for the sufficiently ductile behavior.
        4,000원
        20.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper assesses the structural performance (force-slip response, slip modulus, and failure modes) of a CLT-concrete composite by conducting fifteen push-out test specimens. In addition, non-linear 3D finite element analysis was also developed to simulate the load-slip behavior of the CLT-concrete specimens under shear load. All 15 test specimens simulating the effect of concrete thickness, connection angle and penetration depth with four different shear connector types were built and tested to evaluate the flexural performance. Experimental results show that the maximum shear capacity for the composite action is obtained when the fixing angle is 90° and the penetration depth of 95mm for SC normal screw was used to achieve ductile failure compared to other shear connectors.
        4,000원