        1.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper presents the effect on the inelastic behavior and structural performance of concrete and filled steel pipe through a numerical method for reliable judgment under various load conditions of the CJS composite structural system. Variable values optimized for the CJS synthetic structural system and the effects of multiple variables used for finite element analysis to present analytical modeling were compared and analyzed with experimental results. The Winfrith concrete model was used as a concrete material model that describes the confinement effect well, and the concrete structure was modeled with solid elements. Through geometric analysis of shell and solid elements, rectangular steel pipe columns and steel elements were modeled as shell elements. In addition, the slip behavior of the joint between the concrete column and the rectangular steel pipe was described using the Surface-to-Surface function. After finite element analysis modeling, simulation was performed for cyclic loading after assuming that the lower part of the foundation was a pin in the same way as in the experiment. The analysis model was verified by comparing the calculated analysis results with the experimental results, focusing on initial stiffness, maximum strength, and energy dissipation capability.
        4,300원
        2.
        2021.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        콘크리트가 충전된 강관 합성기둥은 화재 시 내부 콘크리트가 내력을 견딜 수 있어 높은 하중을 받는 건축물에 적용되고 있으나 높은 내화성능을 요구하는데 반해 이를 평가할 수 있는 방법은 제한되어 있다. 본 논문에서는 폭 700mm 이상인 무피복 대형합성기둥의 온도분포를 확인하기 위해서 수평가열로에서 3시간 내화실험을 수행하고 이후에 압축실험에 수행하여 잔존내력을 확인하였다. 실험 결과 3시간의 화재 노출 후에 폭 700mm 대형합성기둥은 57%의 잔존내력을 가지는 것으로 나타났으며, 재료의 화재 강도저감만을 고려한 잔존내력 예측은 내력을 낮게 평가하는 것으로 나타났다.
        4,000원
        3.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        제한된 토지의 효율적 이용을 위하여 건물들이 점점 더 거대화, 초고층화 되어가고 있기 때문에, 대형합성기둥에 대한 수요가 증가하고 있는 추세이다. 선행 연구를 통하여 리브를 갖는 냉간성형강재를 사용하여 구조적으로 안정적이며 경제적 인 충전강관기둥(ACT Column Ⅰ)이 기존에 개발되었으나, ACT Column Ⅰ은 크기가 제한(618×618)되는 문제가 있기 때문에 새로운 폭 1m이상 고하중용 대형합성기둥의 개발이 필요하다. 본 연구에서는 폭이 커지고 접합부 형식이 단순해지는 대형합성기둥(ACT Column Ⅱ)를 제안하고, 바인딩프레임이 보강된 실험체를 중심압축가력하여 구조성능을 확인하였다. 콘크리트 충전 여부 및 바인딩프레임의 보강 폭과 면적을 변수로 한 바인딩프레임 보강 실험체를 중심압축가력 하여 실험체 최대내력 값과 KBC2016 합성구조 설계메뉴얼에 따른 설계내력을 비교한 결과 ACT Column Ⅱ이 대형합성기둥으로써 안정적으로 거동함을 확인하였다.
        4,000원
        5.
        2018.04 구독 인증기관 무료, 개인회원 유료
        As buildings are becoming larger, demand for large-scale composite columns for heavy load is increasing. Welded built-up CFT column (ACT Column I) previously developed by authors of this study is structurally stable and economical. Characteristic of welded built-up CFT column is that there is a limitation of cross-sectional size and application of external diaphragm connection to ensure continuity of rib. Then, composite mega column (ACT Column II) was developed to improve limit of cross-sectional size. Composite mega column has a closed cross section like welded built-up CFT column, but thick plate is inserted between cold-formed steel to expand cross section size. However, when external diaphragm connection is applied to composite mega column, amount of steel is increased greatly and interference with finishing material occurs. In this study, internal diaphragm connection is applied through characteristic of composite mega column to which beam flange or stiffener can be attached to plate. In order to analyze this, simple tensile experiment of composite mega column connection with T-shaped stiffener was performed.
        3,000원
        6.
        2018.04 구독 인증기관·개인회원 무료
        Unlike column-to-beam connections in reinforced concrete frames, column-to-beam connections are generally of the same type. Vertical load (D.L + L.L) and horizontal load (wind load, seismic load) are not the same in the upper and lower flange stress history. In the case of beams bonded to synthetic CFT columns, the tensile force is transmitted through the steel pipe column, and the compressive force is transmitted to the filled concrete, so the seismic performance is excellent even if the column has a relatively thin cross section. Also, in case of beam the composite CFT column, tensile force is taken by the steel pipe column, and the compressive force is caught by the inner concrete, and the shape of the column joint can be changed. In this study, the stress distribution of buildings is investigated according to the size and characteristics of the building, and the load history of the upper and lower flanges according to the building type is checked to show the structural possibility of the Asymmetric Diaphragms joint.
        7.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study develops numerical model of mega composite columns in fire and investigates the residual areas using 500℃ isotherm method and residual capacity of mega composite columns after 3 hours. In order to perform heat transfer analysis, thermal properties of steels and concrete were adopted from Eurocodes. In addition to, the temperature distributions of composite columns with respect to fire tests were compared with numerical analysis results. As a result, residual capacity of mega composite column with 1m width remained more than 45%. The residual capacity of mega composite column was only increased to 2.3∼2.6% with the use of additional rebars.
        4,000원
        8.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As buildings are becoming larger, demand for mega-sized composite columns (over 1-meter diameter) is increased. We have developed and commercialized welded built-up CFT column (ACT Column I) since 2005 which are structurally stable and economical using cold-formed steel with rib. However, there has a limit in size of cross section (618˟618mm) by a fabrication facilities. And due to characteristics of closed cross section, there has a limit to construction of connection of moment frame. Composite mega column (ACT Column II) has same concept of forming closed cross section. But in order to enlarge cross sectional size, thick plate is inserted between cold-formed steels. Since composite mega column can control thickness and width of thick plate, steel or composite beams can be directly attached to the connection. In this study, we propose strength formula of composite mega column to beam connections with T-shaped stiffener as internal diaphragm and verified through finite element analysis and simple tensile experiment.
        4,000원
        9.
        2017.04 구독 인증기관·개인회원 무료
        As the ridges become larger and larger, a structural type that enables effective utilization of the long span and space is required. In the construction stage, the steel column supports the installation load. However, in order to secure the stability against the out - of - plane deformation of the steel column due to the lateral pressure when the concrete is laid, a binding frame is installed inside the steel pipe at constant intervals to resist the concrete installation pressure. When the concrete is cured and its performance as a composite section is exerted, a stress is generated which pushes the steel pipe out of the plane by the column compressive force. In this case, since the binding frame controls the deformation, the local buckling is delayed and the constraining effect on the concrete is increased. In order to evaluate the structural performance and behavior of the composite mega column according to the eccentricity effect and the effect of the binding frame, we carried out a structural test by fabricating eight monopole specimens with the binding frame reinforcement, reinforcing gap, reinforced cross section and eccentricity , And the experimental results are compared with the KBC2016 design formula.
        10.
        2017.04 구독 인증기관 무료, 개인회원 유료
        The utilization of composite columns is increasing due to the construction of high-rise buildings and large buildings. The commercially available concrete chimney steel column (ACT I) is a stable and economical structure, but there is a limit in the section size to be applied to a composite column subjected to a high load. We have developed a composite mega column with an integral structure by adding a plate to the central part of the ACT I column and installing a binding frame at a certain interval inside the central plate. In this study, to evaluate the compressive performance of the composite mega column, four test specimens were constructed with binding frame reinforcement, reinforcement spacing, and reinforced cross - sectional area. The structural performance of the composite section is compared with that of KBC2016 to evaluate the behavior of the specimen.
        3,000원
        11.
        2017.04 구독 인증기관·개인회원 무료
        This study develops numerical model of mega composite columns in fire and investigates the residual areas below 500℃ after 3 hours. In order to perform heat transfer analysis, thermal properties of steels and concrete were adopted from Eurocodes. In addition to, the temperature distributions of composite columns with respect to fire tests were compared with numerical analysis results. As a result, the residual areas below 500℃ of mega composite columns were evaluated.
        12.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Composite columns are increasingly used due to the construction of super-tall buildings and large-scale buildings. Studies on the shapes of and construction technologies for structural members using steel tubes are being conducted actively. Welded built-up CFT columns previously developed and commercialized by the authors of this study (ACT-1 columns) are structurally stable and economically efficient. However, the 1m limit in the width of the columns and their small interior spaces impose a difficulty in installing reinforcing materials and thus deteriorate the ease and efficiency with which they are constructed. This study suggests placing thick plates at the centers of the surfaces of the existing ACT-1 column and installing a binding frame (binding frames) at the central thick plates to enhance the integrity and resist lateral pressure caused by concrete casting. Finite element analysis was conducted with the variables of the number and cross-sectional size of the binding frame and the cross-sectional size of the steel tube to estimate the structural behavior of the steel tubes. Hydraulic tests were conducted to analyze load-displacement relations and identify the influence of the binding frames on the relations. The variables in the tests were the number and cross-sectional size of the binding frame, welding details, column joint and the cross-sectional size of the steel tube
        4,000원
        13.
        2016.04 구독 인증기관 무료, 개인회원 유료
        In this study the structural performance of new composite column to composite beam connection was evaluated by cyclic tests. It is designed to be applied to various types of through type system to the bottom plate to view synthesis composite beam. A composite column is composed of a RC type column reinforced by steel angles which the end bends in each edge corners of column. also, A composite beam is composed of trussed type’s web, a bottom steel plate and reinforced by steel angles which the end bends in each edge corners of beam. 4 cyclic tests of the clarified structural performance of the connections are performed. All specimens that is apply reinforced concrete beam-column joints based on KBC2009 criteria was performed by cyclic test of column to beam. All specimens were exposed to be satisfied with the required ultimate strength.
        3,000원
        14.
        2016.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the seismic performance of connections between filled composite beam (CG beams) and forming angle composite (FAC) column was experimentally evaluated. First, the bending tests were conducted on two CG beams and the axial tests were conducted on two FAC columns. Then, based on these preliminary test results, the cyclic loading test were performed on two interior connections between CG beam and FAC column. The main difference of two specimens is the plate shape of the CG beam. The test results showed that both specimens achieved the maximum story drift capacity over 0.04 radian which is required for special moment frame.
        4,000원
        15.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Other countries(USA, Europe) have performed the fire resistance design of buildings by the alternative performance design methods, which are based on fire engineering theories. However, in Korea, the process on the alternative fire resistance performance design has only suggested without any applications for real steel structures. Therefore, In the case of steel structures stagnant research on refractory measures face difficulties in introducing fire resistance design. In this study, first of all, Intumescent paint was analyze the thermal properties(thermal conductivity, specific heat and density). In Sequence, using the section factor by H-standard section propose of section concrete filled steel tube and hollow. finally presents a reasonable thickness Intumescent paint takes time to target performance of the proposed cross-section steel tube.
        4,000원
        16.
        2014.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study describes the development of innovative connections between steel beams and concrete-filled tube columns that utilize a combination of low-carbon steel and super-elastic shape memory alloy components. The intent is to combine the recentering behavior provided by the shape memory alloys to reduce building damage and residual drift after a major earthquake with the excellent energy dissipation of the low-carbon steel. The analysis and design of structures requires that simple yet accurate models for the connection behavior be developed. The development of a simplified 2D spring connection model for cyclic loads from advanced 3D FE monotonic studies is described. The implementation of those models into non-linear frame analyses indicates hat the recentering systems will provide substantial benefits for smaller earthquakes and superior performance to all-welded moment frames for large earthquakes.
        4,000원
        17.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Pile foundations constructed by the fiber reinforced polymer plastic piles have been used in coastal and oceanic regions in many countries. Generally, fiber reinforced polymer plastic piles are consisted of filament winding FRP which is used to wrap the outside of concrete pile to increase the axial load carrying capacity or pultruded FRP which is located in the core concrete to resist the bending moment arising due to eccentric loading. In this paper, the analytical procedures of hybrid concrete filled FRP tube flexural members are suggested based on the CFT design method. Moreover, the analytical results are compared with the experimental results to obtained by the previous researches. The results of comparison analyses are performed to estimate the accuracy of the analytical procedure for hybrid FRP-concrete composite compression test, members under eccentrical loading.
        4,000원
        18.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 변위기반 성능설계 개념에 의해 기존 철근콘크리트 기둥과 콘크리트에 강재를 매입한 SRC 합성기둥에 대하여 최대 설계지진 가속도에 대한 내진성능개선의 성능설계을 비교하였다. SRC 합성기둥은 구조물의 강도를 증가시킬 뿐 아니라 연성도를 증가시키는 효과가 있다. SRC 합성기둥의 단면은 H형 강재와 원형의 중공 강관을 매입한 형태로 구성되어 있다. SRC 합성기둥에 대한 P-M상관도와 단면 공칭휨모멘트를 분석하고 이를 바탕으로 SRC 합성기둥에 대한 설계 변위 추정을 위해 변위기반 내진 설계 알고리즘을 제시하였다. 성능기반설계에 의한 성능개선설계를 위하여 목표성능변위 및 설계지진가속도 조건에 대해 직접변위 기반 설계방법 및 변위계수법에 의한 내진성능개선 설계 방법을 제시하였다. SRC 합성기둥은 기존 RC 기둥과 비교하여 성능개선 설계 결과 변위 연성비 및 변위성능에서 크게 개선된 성능설계 결과를 나타내었다.
        4,000원
        19.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Concrete filled steel tube (CFT) columns have been widely used in moment resisting frame structures both in seismic zones. This paper discusses the design of such members based on the advanced methods introduced in the 2005 AISC Specification and the 2005 Seismic Provisions. This study focuses particularly on design following both linear and nonlinear methods utilizing equivalent static and dynamic loads for low-rise moment frames. The paper begins with an examination of the significance of pseudo-elastic design interaction equations and the plastic ductility demand ratios due to combined axial compressive force and bending moment in CFT members. Based on advanced computational simulations for a series of five-story composite moment frames, this paper then investigates both building performance and new techniques to evaluate building damage during a strong earthquake. It is shown that 2D equivalent static analyses can provide good design approximations to the force distributions in moment frames subjected to large inelastic lateral loads. Dynamic analyses utilizing strong ground motions generally produce higher strength ratios than those from equivalent static analyses, but on more localized basis. In addition, ductility ratios obtained from the nonlinear dynamic analysis are sufficient to detect which CFT columns undergo significant deformations.
        4,500원
        20.
        2011.04 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to deliberate on design application for a structure of beam with partially restrained composite connection to CFT column. It was intended to apply an economic and stable component by adjusting stiffness ratio of column connection through partially restrained composite connection. As a result of the review of stability of the structure, it was confirmed that in case of a low-rise building as a moment frame, it could be resisted without brace, as stiffness was increased when taking advantage of partial restrained composite connection by composite action.
        3,000원