Due to rapid spread of fireblight, the Rural Development Administration is supplying bactericides to farmers. However, research on inhibitory effects of main active ingredients in these bactericides on fireblight is lacking. Chlorophyll fluorescence analysis is a non-destructive method for analyzing the photosynthetic efficiency of plants, enabling time-series data analysis of pathogen progression and allowing for large-scale studies. Therefore, this study analyzed inhibitory effects of main active ingredients in bactericides on fireblight using chlorophyll fluorescence response analysis. Flowering pear trees (three-year-old ‘Shingo’ variety) were sprayed with control agents and fire blight pathogens on flowers. Chlorophyll fluorescence responses were then measured at seven-day intervals. Twenty-eight days after bactericide treatment, the fluorescence of the O-J transition stage in the untreated group was twice as high as in the average bactericide-treated group presumably due to inhibition of electron transport in the PSII donor side caused by pathogen infection, leading to leaf necrosis. Additionally, the electron transport efficiency (ET2o, RE1o) decreased, reducing the driving force of photosynthesis (DF total ABS) to 20% of the average bactericidetreated group, indicating chlorophyll damage and reduced photosynthetic capacity. In conclusion, chlorophyll fluorescence technology can be used to quantitatively evaluate the efficacy of fire blight control agents during the flowering period of pear trees.
High-risk microbial pathogens are handled in a biosafety laboratory. After experiments, the pathogens may remain as contaminants. To safely manage a biosafety laboratory, disinfection of microbial contaminants is necessary. This study was carried out to evaluate the effect of UV-C irradiation for the disinfection of a high-risk plant pathogenic bacterium Erwinia amylovora in a laboratory setting. For the test, the bacterium (8.7 × 106 CFU/ml) was embedded on the surface of PDA and placed on the work surface in a biosafety cabinet (Class 2 Type A1), and on the three different surfaces of the laboratory bench, laboratory bench shelf, and the floor which were positioned in a straight line from the UV lamp installed in the ceiling of the biosafety laboratory (BSL 2 class). UV-C irradiation was administered for 10min, 30min, 1 hr, 2hr, 3 hr, and 4hr, respectively. The reduction rate of bacteria ranged from 95% to 99% in regard to 10 min irradiation, from 97% to 99% in regard to 30 min irradiation, from 99.8% to 99.9% in regard to 1 hr irradiation, and higher than 99.99% in regard to 2 hr irradiation. The bacterium was completely inactivated after 3 hr irradiation. A similar UV-C irradiation effect was obtained when the bacterium was placed at a distance of 1 m from the three different surface points. Bacterial reduction by UV-C irradiation was not significantly different among the three different surface points.
This study presents the estimation of crack depth by analyzing temperatures extracted from thermal images and environmental parameters such as air temperature, air humidity, illumination. The statistics of all acquired features and the correlation coefficient among thermal images and environmental parameters are presented. The concrete crack depths were predicted by four different machine learning models: Multi-Layer Perceptron (MLP), Random Forest (RF), Gradient Boosting (GB), and AdaBoost (AB). The machine learning algorithms are validated by the coefficient of determination, accuracy, and Mean Absolute Percentage Error (MAPE). The AB model had a great performance among the four models due to the non-linearity of features and weak learner aggregation with weights on misclassified data. The maximum depth 11 of the base estimator in the AB model is efficient with high performance with 97.6% of accuracy and 0.07% of MAPE. Feature importances, permutation importance, and partial dependence are analyzed in the AB model. The results show that the marginal effect of air humidity, crack depth, and crack temperature in order is higher than that of the others.
Crack in concrete surfaces is one of the earliest signs of decomposition of the essential structure and constant exposure will cause serious damage to the structure and environment. In most of the safety assessment and fracture mechanic applications proposed that these cracks and defects eventually will grow and will have potential lead to in-service failure. Crack in concrete surfaces is one of the earliest signs of decomposition of the essential structure and constant exposure will cause serious damage to the structure and environment. Currently, non-destructive methods are getting popular in the field of inspecting defects in structure and one of them in trends is that using the thermographic image to detect hidden effects. However, the accuracy of the thermal camera, also called resolution, is highly dependent on camera variables such as lens, detector, sensitivity etc. Also, the most important question that needs to be answered for this research is what happens to the image in fog, rain or other climatic conditions where the camera detects crack which exceptionally smaller than most thermographic applications detects. This paper investigates the accuracy of thermal images obtained by the thermal camera under various weather condition and aims at providing information about optimum choice of environmental condition where the more favorable thermal images can be obtained and increase survey reliability and accuracy of the analysis.
Since the expectations and demand for higher ride comfort of the customers (driver and passengers) have been dramatically increased, new vehicle model launched on the market have not only better performance and design-wise appealing, but also ride comfort has to be increasingly better than its predecessor. Automotive manufactures have focused on the increasing human thermal comfort. To achieve a high thermal comfort, most manufacturers provide a system for their cars to ensure ventilation, heating and cooling air in the passenger compartment. As results, the influence of the seats and situations in the thermal human comfort are considered. And, the temperature distribution pattern on the human face is acquired at natural condition, both warm condition on which seat is managed around 30℃ and hot condition on which seat is managed around 50℃.
PURPOSES : In this study, an image analysis method is used to evaluate the pore structure characteristics and permeability of hybrid concrete.
METHODS: The binder weight of hybrid concrete is set to 400 kg/m3, 370kg/m3, and 350 kg/m3, and for each value of binder weight, the pore structure and permeability of concrete mixture is evaluated. The permeability of hybrid concrete is evaluated using a rapid chloride penetration test(RCPT).
RESULTS : The concrete pore structure characteristics of hybrid concrete reveals that as the binder weight is reduced, the entrained air is reduced and the entrapped air is increased. The permeability of the hybrid concrete for all values was measured to be below 1000 C, which indicates a "Very Low" level of permeability relative to the evaluation standard of KS F 2711. Additionally, as the binder weight is decreased, there is a significant increase in the permeability of chloride ions.
CONCLUSIONS : In this study, the pore structure characteristics of hybrid concrete at different binder weights shows that as the binder weight is reduced, the entrained air is reduced and the entrapped air is increased. Consequently, chloride ion penetration resistance of the hybrid concrete is diminished. As a result, it is expected that this will reduce the concrete’s durability.
IR camera has been used widely for the temperature measurement and fault detection of the moving bodies and rotating bodies. The high-speed performance of the IR camera and a reliable thermal analysis method are required for the condition monitoring of the railway vehicle running at high speed. The effective fault detection method using a thermal image analysis could make a real time monitoring of the high speed train possible. Therefore the investigation of the performance of the thermal image analysis method was performed to find the effective thermal image data analysis method. The results suggested that the comparison of the characteristics of the temperatures obtained at different conditions and a continuous temperature subtraction method could be used as a useful analysis method for detecting abnormal temperature condition and histogram equalization could also help to enhance the fault detectability by increasing the contrast of the thermal image
최근 국내 콘크리트포장의 동결융해 파손에 대한 사례들이 주기적으로 보고가 되고 있으며, 이에 공기량 기준과 더불어 간격계수에 대한 기준마련 필요성이 대두되고 있다. 간격계수를 산정하기 위한 실험방법은 국내에 규정되어 있지 않아 ASTM C 457기준을 따라야 하며, 특히 이 실험결과 분석 시 연구자의 주관적 판단에 기인하는 경우가 많아 이에 대한 철저한 보정작업이 수반되어야 한다. 콘크리트의 공극구조 특성을 분석하기 위해 사용되고 있는 화상분석프로그램은 색상의 구분을 통해 공극을 인식하는데, 분석 시 사용되어지는 pixel intensity values에 따라 분석결과는 크게 변할 수 있다. 이에 본 연구에서는 pixel intensity values의 적정범위를 산정하기 위해서, pixel intensity values 변화에 따라 측정된 공극수와 연구자들이 측정한 공극수를 비교하였으며, 이를 통해 pixel intensity values의 적정 범위를 결정하였다. 또한 결정된 pixel intensity values를 이용하여, 8가지 콘크리트 혼합물에 대한 콘크리트 공극구조 특성을 분석하였다. 연구자들이 공극수를 직접 측정한 round robin test 결과, 사람에 따른 공극 인식정도가 약 10% 정도로 변동될 수 있음을 확인할 수 있었으며, 이를 통해 pixel intensity values의 적정 범위가 약 80~90 정도로 나타났다. 8가지 콘크리트 혼합물에 대한 화상분석결과, 전반적으로 AE제 첨가량이 증가함에 따라 전체 공기량은 증가하고 간격계수는 감소하는 경향을 나타내었으나, 일부 혼합물에서 공기량은 크게 변동하지 않은 가운데 간격계수가 AE제 증가에 따라 감소하는 추이를 나타내었다. 이는 추가된 AE제에 의해 발생된 미세한 크기의 연행공극이 전체 공기량에 미치는 영향보다 간격계수에 미치는 영향이 더 크기 때문이다. 또한 동일한 시편에서 절단면 위치에 따른 간격계수의 편차는 약 30~100μm 정도를 나타내었다. 이는 2차원 분석의 한계로 인해 발생된 편차인 것으로 사료되며, 시편절단면 위치에 따른 변동성 분석을 위한 추가적인 연구가 수행되어야 할 것으로 판단된다.
하상재료 조사는 유사량 계산 및 하상변동과 같은 하도 계획에 필요한 기초 자료로서 입도분포, 비중, 다공성 등을 조사하는 것이다. 원칙적으로, 조사 지점은 하천 종단 방향으로 1 km 간격이고 하나의 횡단면에 3 개 이상이다. 따라서 조사 대상 하천의 종단 길이에 따라 조사 지점이 아주 많아지기 때문에 조사에 소요되는 시간과 비용이 상당히 증가한다. 본 연구는 입도분석법인 체적법과 화상해석법의 작업 효율성과 비용을 비교하고, 화상해석법의 적용 가능성을 검토하였다. 화상해석법에 의하여 환산된 등가원의 직경이 하상재료 입도분석에 적용될 수 있음을 확인하였다. 또한, 체적법과 화상해석법의 작업효율성과 비용을 분석한 결과 약 80%의 절감효과가 있음을 입증하였다.
현재 정부에서는 폐자원 에너지의 회수・사용을 촉진하기 위해 정책적인 움직임을 보이고 있다. 폐기물 소각시설의 소각열에너지 회수・사용률 산정방법이 2015년에 확정되었고, 이를 반영한 자원순환기본법이 2018년 1월 1일부터 시행될 계획이다. 이에 따라, 국내 폐기물 소각시설의 에너지 회수・사용률을 증가시키기 위해 열에너지 회수를 통한 전기나 열원 생산의 효율을 측정하고 평가하는 것이 필요하다. 폐기물 소각시설 공정에서의 방열손실은 열에너지 회수의 효율을 저하시키는 원인 중 한가지이다. 이를 평가하기 위하여 소각시설의 벽면온도를 측정하여야 하며, 현재의 소각시설 벽면 온도 측정 방법은 환경부 고시 ‘폐기물 처리시설의 세부검사방법에 관한 규정’의 별표1 ‘폐기물 소각시설의 세부 검사방법’에 따른 지점측정 방식이다. 하지만 지점측정 방식의 온도 측정은 접촉식 온도계를 이용한 측정법으로, 대상의 접촉 지점에 따라 온도가 다르게 측정될 수 있으며 대상 시설의 평균 표면온도를 정확하게 측정하는 것에 한계를 가진다. 적외선 열화상 카메라는 대상의 넓은 면적을 동시에 촬영하여 온도를 측정하는 방식으로, 시설의 평균 표면온도를 비교적 정확하게 측정할 수 있다. 따라서 본 연구에서는 실제 가동 중인 폐기물 소각시설의 벽면 온도를 비접촉 온도 측정 방식의 적외선 열화상 카메라를 이용하여 측정하고, 기존에 수행되었던 연구를 통해 정립된 방열손실 산정식을 이용하여 방열손실을 계산하였다. 또한 폐기물의 소각 온도, 소각 용량, 소각로 표면적 크기 등 여러 가지 요인에 의한 방열손실을 고려하기 위하여 소각시설의 입열과 출열 항목을 측정하여 투입된 에너지 대비 손실량인 방열손실률을 산정하여 평가하였다.
Recently, domestic waste policy has focused on resource circulation. In accordance with Article 3, Paragraph 2 of the “Enforcement Rules of Wastes Control Act”, which is targeted at waste incineration facilities, we established and announced methods for calculating the recovery and utilization rates of incineration-sourced heat in 2015. The lower heating value is important to energy recovery and utilization rate calculations. Hence, the lower heating values of the waste incineration facilities were estimated using the thermal method from KS B 6205. Heat loss decreases the heat recovery efficiency, and should be measured and evaluated. The surface temperatures of the incinerator and boiler are required to determine heat loss. Presently, the contact point temperature method is used to measure the surface temperature. It is difficult to apply this method to the average surface temperature of an incineration facility. In this study, 20 Korean waste incineration facilities were selected for heat loss estimates based on waste incineration temperature, incinerator type, and incineration capacity. Infrared thermal cameras were used to measure the surface temperatures of the waste incineration facilities.
‘전국 폐기물 발생 및 처리현황’(환경부, 2014)에 따르면, 국내의 전국 폐기물 총 발생량은 매년 증가하는 추세이다. 건설 폐기물을 포함한 ‘14년도 총 폐기물 발생량은 388,486톤/일에 달하며, 지정폐기물을 포함하면 폐기물 발생량은 더 증가한다. 이렇게 발생한 폐기물은 매립, 소각, 재활용, 해역배출로 처리되었다. 하지만 국내의 육상 폐기물 해역배출은 런던협약에 ‘16년부터는 전면 금지되었으며, 매립과 재활용을 통한 폐기물의 처리는 한계가 있다. 지속적으로 발생량이 증가하는 폐기물의 처리와 지정폐기물, 재활용 금지 및 제한대상 폐기물을 처리하기 위하여 폐기물의 소각처리가 필수적으로 요구된다. 국내에서는 정책적으로 폐기물 소각시설의 폐자원에너지 회수와 사용에 대해 집중하고 있으며, 2015년에 폐기물 소각시설의 소각열에너지 회수・사용률 산정방법을 확정하여 2018년 1월 1일부터 자원순환기본법을 통해 시행할 것을 예고하였다. 사업장폐기물 소각시설의 소각열에너지 회수・사용률 산정방법에 따르면 열정산법을 이용해 입열과 출열을 산출하여 소각시설의 효율을 계산한다. 소각로의 방열손실은 에너지의 회수 효율을 낮추는 출열 항목 중 한가지로 각 시설마다 측정하여 평가되어야 한다. 현재 방열손실 평가를 위한 소각로의 벽면 온도 측정은 지점측정법을 이용하여 실측되고 있다. 하지만 접촉식 온도 측정은 대상의 접촉 지점마다 온도가 다르게 측정 될 수 있으므로 대상 시설의 평균 표면온도를 정확하게 측정하는 것이 어렵다. 비접촉 방식으로 온도를 측정하는 적외선 열화상 카메라는 넓은 면적의 온도를 동시에 측정 가능하며 대상 시설의 평균 온도를 비교적 정확하게 측정 할 수 있다. 따라서 본 연구에서는 폐기물 소각시설의 출열 항목 중 방열손실의 측정 및 평가를 위해 적외선 열화상 카메라를 이용하였으며, 소각로 표면 온도 측정방법과 소각시설의 방열손실 산정 방법을 정립하였다.
Deterioration of insulation and retrofitting existing buildings to make the data necessary for the insulation of the survey should precede. Measuring infrared (IR systems) using insulation on-site apartment Segmental analysis of the structure is to evaluate the let part. Temperature and temperature gradient by the degradation of the insulation of apartment structures can be evaluated.