검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 125

        21.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study analyze the dynamic response property of latticed domes according to natural frequency ratio of substructure. Through eigenvalue analysis, it is was confirmed that the half-open angle 30° and 45° dominate vibration mode of the vertical direction and the half-open angle 60° and 90° dominate vibration mode of the horizontal direction. Through the dynamic response analysis, it is was confirmed that the first frequency about total structure largely appears about the vertical and the horizontal direction regardless of half-open angle.
        4,000원
        22.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        It is very important to calculate natural frequency of the observatory tower correctly because it is keenly affected by wind response vibration due to its large slenderness ratio, weight and small damping ratio. Additionally, suggestion equation of natural frequency being used in the design phase has considerable difference between actual measured value thereby making it inappropriate to be used in the serviceability design of the observatory tower. Therefore, this paper conducted an ambient vibration measuring on 10 observatory towers through mobile-phone application thereby calculating the natural frequency and comparing the result with the domestic and foreign standards and that of the eigen-value analysis. This paper suggested approximate equation of the natural frequency of the observatory tower; T=0.0266H. The square of the corelation coefficient is 0.940, which is high.
        4,000원
        23.
        2016.05 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        In the present study, the tensile properties and dynamic strain aging of an Fe-24.5Mn-4Cr-0.45C alloy were investigated in terms of strain rate. During tensile testing at room temperature, all the stress-strain curves exhibited serrated plastic flows related to dynamic strain aging, regardless of the strain rate. Serration appeared right after yield stress at lower strain rates, while it was hardly observed at high strain rates. On the other hand, strain-rate sensitivity, indicating a general relationship between flow stress and strain rate at constant strain and temperature, changed from positive to negative as the strain increased. The negative strain-rate sensitivity can be explained by the Portevin Le Chatelier effect, which is associated with dynamic strain aging and is dependent on the strain rate because it is very likely that the dynamic strain aging phenomenon in high-manganese steels is involved in the interaction between moving dislocations and point-defect complexes.
        4,000원
        24.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 전통 목조건축물로 되어 있는 대한민국의 국보 1호인 숭례문의 구조해석을 수행하고 안전도를 평가하였다. 전통 목조건축의 대부분의 하중을 차지하고 있는 숭례문의 지붕하중을 상세히 산정하고 숭례문의 가구구성 특징을 면밀히 살펴 범용 구조해석 소프트웨어인 midas Gen으로 구조해석모델을 구축하였다. 수직하중에 대한 정적구조해석을 수행하고 주요 수직 수평 구조부재의 안전성과 주요 수평부재의 사용성을 평가하였다. 숭례문의 동적거동특성을 평가하기 위하여 현장에서의 충격해머실험과 구조해석 소프트웨어를 이용한 고유치해석을 수행하고 그 결과를 비교하고 주요모드를 도출하였다. 수직하중에 대한 검토결과 숭례문은 구조적 능력에 여유가 있는 것으로 나타났다.
        4,000원
        25.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The effects of mixing speed (3, 6 and 10 speed) and time (2, 5 and 10 min) on the dynamic viscoelasticity of dough and the baking properties of gluten-free rice bread were investigated. The specific gravity of the dough was not affected by the mixing speed and time before and after fermentation. The elasticity (G') and viscosity (G") of the dough increased and the tan δ (G"/G') decreased with higher mixing speeds and longer mixing times. The specific volume of the gluten-free rice bread was affected by the mixing time in response surface methodology (RSM). The hardness of the gluten-free rice bread showed a decreasing trend as the specific volume for the gluten-free rice bread increased. The appearance of the gluten-free rice bread was symmetrical at high mixing speeds and long mixing times. Overall results indicated that the quality of gluten-free rice bread could be improved by controlling the mixing speeds and mixing times for the dough.
        4,000원
        26.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The serviceability design of the high-rise building is affected by the wind response vibration such as the acceleration, at this time it is important to calculate the natural frequency correctly. Since the suggestion equation of the natural frequency being used in the design phase is not the regression equation obtained from the vibration measurement of the high-rise building, the verification to use for the serviceability design of the high-rise building is necessary. This thesis conducted an ambient vibration measuring on the high-rise building through the mobile-phone application to calculate the natural frequency and suggested a natural frequency approximate expression following the building's height, and compared with the domestic/foreign standard and the result of the eigen-value analysis.
        4,000원
        27.
        2015.10 구독 인증기관·개인회원 무료
        최근 기후변화로 인한 집중호우의 강도와 빈도가 증가하면서 아스팔트 포장의 포트홀 발생이 급격히 증가하고 있다. 포트홀은 아스팔트 포장에 침투된 수분이 교통하중과 함께 간극수압을 야기하여 아스팔트 포장의 골재 표면과 아스팔트 바인더 사이의 점착력을 약화시켜 박리가 발생하여 포장이 파손되는 것을 말한다. 이로 인해 아스팔트 포장체의 조기 파손이 발생하게 되면 아스팔트 포장의 공용성을 감소시키고 유지·보수비용을 증가시키므로 사용재료에 대한 점착력 특성을 파악하는 작업이 반드시 필요하다. 본 연 구에서는 아스팔트 포장시공에 많이 사용되는 3가지 종류의 아스팔트 바인더(PG58-22, PG64-22, PG76-22)를 선정해서 동적수침시험(Dynamic Immersion Test)과 바인더 점착력 시험(Bitumen Bond Strength, BBS Test)을 수행하여 각 아스팔트 바인더의 점착력을 평가하였다. 동적수침시험은 EN 12697-11 기준에 의해 수행되었으며, 주관적인 결과분석방법(육안평가)의 개선을 위해 DIA(Digital Image Analysis)를 통해 객관적인 평가를 수행하였다. 각 시편은 기존에 적용되던 육안조사와 무게변화 의 방법을 수행하는 동시에 객관적인 평가를 위해 Mesh Analysis 방법을 적용하였다. 각 시편을 동일한 조건에서 스캔하여 얻어진 이미지 파일을 총 400(20×20)개의 mesh로 나뉘어 각 cell에 대한 피복율을 5 단계의 가중치를 적용하여 계산하였다(Equation 1). Mesh Analysis의 결과를 적용하여 얻어진 기준값 (Threshold Value) 36을 기준으로 DIA를 수행하여 최종 점착력을 비교 ․ 분석하였다. Fig. 1은 동적수침 시험과 BBS Test로 얻어지는 수분민감성과 상온에서의 점착력결과를 나타낸 것이다. 본 연구에서는 DIT의 각 평가 방법을 비교하였고, 그 결과를 BBS 시험과 비교하여 아스팔트 바인더의 점착력을 평가하였으며, 도출된 결론은 다음과 같다. 기존의 DIT 육안평가 방법은 평가자 간의 차이가 크 기 때문에 주관적인 결과를 도출할 가능성이 있으며, DIA를 이용하여 보다 객관적인 평가를 수행할 수 있 을 것으로 판단된다. BBS 시험결과 PG등급이 높을수록 상온에서의 점착력이 좋다는 것을 확인할 수 있 었고, DIT 시험결과 또한 동일한 경향을 보이는 것으로 나타났다.
        28.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        천해역에서의 해상풍력터빈의 기초 형식으로 모노파일, 트라이포드, 재킷 등의 고정식 기초 사이의 최적의 지지구조물 선별에 대한 논의가 세계적으로 활발하게 되어왔다. 다양한 기초 형식 가운데 어떤 기초를 최종 선택하기 위해서는 경제성과 함께 동적설계 측면에서의 검토도 필요하다. 이 연구에서는 고정식 기초를 해상풍력터빈의 기초로 적용하는 경우 전체 구조물의 고유주파수에 미치는 하중 및 지반 물성치의 불확실성의 영향을 정량적으로 검토하였다. 연구결과, 모노파일의 고유주파수의 변동이 가장 심한 것을 알 수 있었고, 따라서 모노파일 기초를 설계에 반영하는 경우에는 지반 물성치의 불확실성을 최소화시키는 것이 중요하다는 것을 알 수 있었다.
        4,000원
        29.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 동조액체기둥감쇠기의 비선형감쇠항을 등가점성감쇠항으로 치환한 등가선형 동조액체기둥감쇠기 모델을 유도하였으며 동조액체기둥감쇠기의 동적거동인 고유진동수와 감쇠비를 이론적으로 파악하였다. 동조액체기둥감쇠기에 일정한 전기장을 형성한 후 동조액체기둥감쇠기의 수직운동에 의해 발생되는 가변전압을 측정하여 수조 내부의 수위로 변환하는 식을 유도하였다. 또한 본 연구에서 제안한 동조액체기둥감쇠기의 수위측정 시스템의 타당성을 검증하기 위하여 고가의 전기 용량식 파고계와 비교 및 검증하였다. 마지막으로 본 연구에서 제안한 수위측정 시스템을 동조액체기둥감쇠기에 적용, 진동대 실험을 실시하여 고유진동수와 감쇠비를 파악하였고, 이론상의 고유진동수와 실험상의 고유진동수가 일치하였음을 확인하였으며, 진동수비 변화에 따른 동조액체기둥감쇠기의 감쇠비 변화를 확인하였다.
        4,000원
        30.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigate the dynamic response changes of rib dome structure according to property changes of Substructure. Eigenvalue analysis is conducted in first natural frequency of rib dome versus substructure and searched in the dominant mode of horizontal and vertical direction. Resonance frequency by each first natural frequency of the rib dome structure, substructure and total structure is applied for a seismic wave. That is analyzed about maximum displacement response ratio and maximum acceleration response ratio.
        4,000원
        31.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: A tack coat has been utilized to increase the bond performance between the surface layer and base course (intermediate course) at various road pavement sites. This is similarly true in other nations. Based on this connection, the objective of the present study is to evaluate the properties of hot mix asphalt (HMA) mixtures with an RSC-4 or BD-Coat and determine the application rate of the tack coat. METHODS: The HMA specimens were manufactured using superpave gyratory compaction. The HMA mixtures were composed of a 5-cm thick surface layer and a 10-cm thick base course. An impact hammer resonance test (IHRT) and a static load shear test were conducted to evaluate the performance of the HMA mixtures with a tack coat. From these tests, the dynamic moduli related to the high-frequency resistance and interlayer shear strength (ISS) of HMA could be obtained. RESULTS: The results of the dynamic moduli of HMA are discussed based on the resonance frequency (RF). To check the accuracy of the IHRT, we conducted a coherence analysis. A direct shear test using the application of a static load test was carried out to evaluate the interlayer shear strength (ISS) of HMA. CONCLUSIONS: The maximum ISS was demonstrated at an RSC-4 application rate of 462 gsm, and the maximum dynamic modulus was demonstrated at an RSC-4 application rate of 306 gsm. By averaging the results of the ISS, the maximum ISS values were obtained when a BD-Coat application rate of 602 gsm was applied.
        4,500원
        32.
        2015.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        가스 생산용 해양플랜트 설비의 경우 폭발의 위험에 노출되어 있으며, 폭발사고는 구조물의 안전성에 치명적인 영향을 미칠 수 있다. 따라서, 이러한 폭발사고에 의한 피해를 최소화하기 위해서는, 폭발하중에 의한 구조부재의 동적응답 특성을 명확히 파악할 필요가 있다. 폭발하중의 경우 매우 짧은 시간 동안에 구조물에 가격되었다가 소멸되기 때문에 구조부재의 고유주기 및 폭발하중의 지속시간을 고려한 동적응답 평가가 필수적으로 요구된다. 일반적으로 가스 폭발하중의 경우, 부 압력단계가 전체 하중 이력에서 상당 부분 존재하며, 본 연구에서는 이러한 부 압력단계의 형상에 따라 총 하중 지속시간을 결정하는 하중 모델을 제안하였다. 방화벽은 폭발사고 시 장비 및 인명 피해를 방지하고자 FPSO 탑사이드 모듈 사이에 배치되는 구조부재이므로 폭발하중에 의한 응답이력 특성 분석이 반드시 필요하다. 때문에 무 감쇠 단 자유도 모델에 가스 폭발하중을 적용하여 변위응답 특성을 분석하였으며, 평판으로 구성된 방화벽의 FE 모델을 이용한 하중 지속시간과 구조부재들의 고유주기를 고려한 응답 특성을 분석하였다. LS-DYNA를 이용한 선형/비선형 구조해석 분석결과, 부 압력단계의 지속시간이 구조물의 동적응답에 큰 영향을 주는 것을 보였다.
        4,000원
        33.
        2015.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        가스 생산용 해양플랜트 설비에서 발생할 수 있는 폭발사고의 경우, 구조 시스템의 기하학적 특성이나, 바람, 가스 누출율 등과 같은 환경적 조건에 의해 피해 규모의 범위가 상당하다. 따라서 폭발파에 의한 구조 부재의 응답을 분석하기 위해서는 이러한 조건들을 고려한 가스폭발 수치해석 과정이 반드시 필요하다. 본 연구에서는 FPSO 탑사이드의 형상 및 장비 배치와 같은 세부적인 부분까지 고려하여 폭발해석을 수행하였으며, 이를 바탕으로 획득한 하중 이력들의 특성을 분석하였다. 또한 다양한 형태로 나타나는 폭발하중 이력들 중 구조물 손상에 직접적으로 영향을 미칠 수 있는 최대 압력과 지속시간들을 고려하여 유한요소해석 시 하중조건으로 적용한 후, 부재의 응답특성에 관한 분석을 수행하였다. 유한요소해석 모델은 실제 구조물에 적용이 가능하고, 복잡한 형상을 이상화한 단 자유도 및 다 자유도 모델을 사용하였다. 정 압력 및 부 압력단계의 최대 압력이 증가함에 따라 구조 부재의 최대 응답이 증가하였고, 부 압단계에서 하중 지속시간이 증가함에 따라 구조물의 최대 변위가 증가는 경향을 보였다.
        4,000원
        34.
        2015.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 복합재 구조물에 손상이 있을 경우, 손상에 의해 변화된 구조물의 동적특성을 손상이 없는 상태로 회복하여, 전체 시스템의 안정성을 유지할 수 있도록 하였다. 층간 분리가 있는 구조물의 유한요소모델 구축을 위하여 향상된 층간 변위장 모델을 적용하였으며, 유한요소해석을 진행하여 구조물의 고유 진동수와 모드 형상을 관찰하였다. 능동제어 알고리즘과 압전 작동기를 적용하여 구조물의 진동 응답특성을 확인하였으며, 이를 바탕으로 손상된 구조물의 동적특성을 손상이 없는 상태로 회복할 수 있음을 확인하였다.
        4,000원
        35.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To improve the noise and vibration problems of the existing public parking systems, new floor system was proposed. This system consists of the Sandwich Plate System(SPS), steel beam and post-tensioned steel tendons. To verify the dynamic characteristics such as the natural frequency and damping ratio of the system, the free vibration test was performed. Test results showed that the natural frequency of the SPS composite beam was 23.8Hz and it was increased by 3.8% by installing the post-tensioned tendons. The damping ratio of the specimen with tendons was about 1.64%.
        4,000원
        36.
        2014.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, the response of graphite/epoxy laminated composite beams subjected to impact loads without damage, is studied by the use of the developed finite element program. The modified Hertzian contact law considered elasto-plastic process is used to calculate the dynamic responses between the impactor and laminated target. Numerical results are presented to demonstrate the effects on the histories of contact force, deflection, damage energy, strain and stress through the thickness due to stacking sequence. In view of the kinetic energy response, [0/30/0/-30]2S laminate is faster than that of other two laminates due to its flexural stiffness. In special, the distribution of stress through the thickness shows nearly linear despite its discontinuity of stacking sequences for dynamic analysis unlike static analysis in a laminated composites.
        4,000원
        37.
        2014.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this paper is to study comparative of dynamic instability characteristic of Geiger-typed cable dome structures by load condition, which is well-known among the cable dome structures that are the lightweight hybrid structure using compression and tension element continuously. Dynamic buckling process in the phase plane is very important thing for understanding why unstable phenomena are sensitively originated in nonlinear dynamic by various initial conditions. But there is no paper for the dynamic instability of hybrid cable dome by Sinusoidal Excitations, many papers which deal with the dynamic instability for shell-structures under the step load have been published. As a result of Geiger-typed cable dome, which shows chaotic behavior in dynamic nonlinear analysis with initial imperfection.
        4,000원
        38.
        2013.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Long span arch structure is composed of arch as relatively flexible structure and column as relatively rigid structure. In this study, the characteristic of dynamic response is analyzed according to the natural frequency ratio between arch and columns. The result of analysis for arch as relatively vertical vibration mode is dominant, the influence of columns mainly appears at relatively high frequency band according to increase of 1st mode frequency in column. However, the dynamic characteristic of arch structure is expected to vary with not only frequency ratio but interaction between vibration modes of arch and columns.
        4,000원
        39.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 39층 테크노마트의 태풍시 진동응답을 계측하고 이로부터 건물의 동적특성을 평가하였다. 2011년 태풍 무이파가 우리나라를 통과할 때 건물의 38층의 가속도 응답을 계측하였으며, 계측신호를 이용하여 구조물의 고유진동수 및 감쇠비등을 독립성분분석법을 사용하여 구하였다. 독립성분분석법을 통해 매우 유사한 크기를 가지는 장변방향 및 단변방향 진동모드를 분리할 수 있었으며, 분리된 모드를 사용하여 각 모드에 해당하는 감쇠비를 추출할 수 있었다. 또한, 하중과 슬래브-보의 합성효과 등을 고려하여 구조해석모델을 개선하여, 개선된 모델이 실제 계측한 진동수 및 감쇠비와 유사한 값을 가지도록 하였다.
        4,000원
        40.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        바닥슬래브의 처짐과 차음 성능을 개선하기 위하여 포스트텐션 중공슬래브가 최근에 자주 사용되고 있다. 동일한 8m 스팬 1층구조물을, 한 구조물은 일반슬래브(solid slab)로, 다른 구조물은 중공슬래브(void slab)로 2개를 제작하여 각 구조물의 바닥슬래브에 포스트텐션을 도입하였다. 중공슬래브의 고유진동수와 감쇠율의 진동특성을 일반슬래브와 비교하였으며, 포스트텐션 도입 후에 일반슬래브와 중공슬래브 각각에 있어서 고유진동수와 감쇠율의 진동특성을 상호 비교하였다. 210mm의 일반슬래브 보다는 250mm 중공슬래브의 1차 고유진동수가 큰 것을 알 수 있다. 포스트텐션 도입 후에도 중공슬래브의 1차 고유진동수는 일반슬래브 보다 큰 것을 알 수 있다. 일반슬래브와 보이드슬래브의 감쇠율은 포스트텐션 도입 전과 도입 후에 거의 동일한 값을 보이는 것을 확인하였다.
        4,000원
        1 2 3 4 5