검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 39

        1.
        2024.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Code-compliant seismic design should be essentially applied to realize the so-called emulative performance of precast concrete (PC) lateral force-resisting systems, and this study developed simple procedures to design precast industrial buildings with intermediate precast bearing wall systems considering both the effect of seismic and blast loads. Seismic design provisions specified in ACI 318 and ASCE 7 can be directly adopted, for which the so-called 1.5S y condition is addressed in PC wall-to-wall and wall-to-base connections. Various coupling options were considered and addressed in the seismic design of wall-to-wall connections for the longitudinal and transverse design directions to secure optimized performance and better economic feasibility. On the other hand, two possible methods were adopted in blast analysis: 1) Equivalent static analysis (ESA) based on the simplified graphic method and 2) Incremental dynamic time-history analysis (IDTHA). The ESA is physically austere to use in practice for a typical industrial PC-bearing wall system. Still, it showed an overestimating trend in terms of the lateral deformation. The coupling action between precast wall segments appears to be inevitably required due to substantially large blast loads compared to seismic loads with increasing blast risk levels. Even with the coupled-precast shear walls, the design outcome obtained from the ESA method might not be entirely satisfactory to the drift criteria presented by the ASCE Blast Design Manual. This drawback can be overcome by addressing the IDTHA method, where all the design criteria were fully satisfied with precast shear walls’ non-coupling and group-coupling strength, where each individual or grouped shear fence was designed to possess 1.5S y for the seismic design.
        4,000원
        2.
        2024.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The design shear strength equations of RC shear walls have been developed based on their performance under in-plane (IP) loads, thereby failing to account for the potential performance degradation of shear strength when subjected to simultaneous out-of-plane (OOP) loading. Most of the previous experimental studies on RC walls have been conducted in one direction under quasi-static conditions, and due to the difficulty in experimental planning, there is a lack of research on cyclic loading and results under multi-axial loading conditions. During an earthquake, shear walls may yield earlier than their design strength or fail unexpectedly when subjected to multi-directional forces, deviating from their intended failure mode. In this paper, nonlinear analysis in finite element models was performed based on the results of cyclic loading experiments on reinforced concrete shear walls of auxiliary buildings. To investigate the reduction trend in IP shear capacity concerning the OOP load ratio, parametric analysis was conducted using the shear wall FEM. The analysis results showed that as the magnitude of the OOP load increased, the IP strength decreased, with a more significant effect observed as the size of the opening increased. Thus, the necessity to incorporate this strength reduction as a factor for the OOP load effect in the wall design strength equation should be discussed by performing various parametric studies.
        4,000원
        4.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, natural period formular is presented for a RC shear wall structure with H-, T-, and L-shaped wall sections. The natural period formular proposed by Goel and Chopra and adopted in ASCE 7-10 was modified by using the ratio of the flange and web wall area. The natural periods of structures with H-shaped wall were numerically obtained, the results indicated that the ASCE 7-10 could not consider the natural period variation according to the length of the flange wall, but the proposed formula could do. Especially, ASCE 7-10 estimated much longer periods than eigenvalue analysis, and this implies that conservative seismic design is difficult. The periods by eigenvalue analysis exist between the upper and lower bounds given by the proposed formula, and conservative design is possible by using the proposed lower bound value. In order to verity the effectiveness of the proposed method, actual residential buildings with various types of flange walls are considered. Ambient vibration tests, eigenvalue analyses, and nonlinear dynamic analyses were conducted and the periods were compared with the values by ASCE 7-10 and the proposed formula. The results showed that the proposed formula could estimate more accurately the periods than ASCE 7-10.
        4,000원
        5.
        2017.04 구독 인증기관·개인회원 무료
        The concrete wall panels are composed of various members such as studs, brackets, bolts and nuts, etc. Embedded studs in the concrete wall resist transferred lateral and horizontal load in the structure. The thickness of the concrete wall influences shear behavior of embedded studs. The finite element analysis was carried out with respect to the thickness of the concrete wall to investigate shear behavior of embedded studs. The numerical analysis results were compared with the experimental results and confirmed that The deformation of the stud anchor is reduced with an increase of the thickness of the concrete wall.
        6.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        When reinforcing an existing reinforced concrete beam-column building with a precast concrete panel, special connection between the PC member and the RC member is required to solve the time dependent deformation of the RC member and to receive the large shear forces. The aim of this study is to obtain the shear strength of upper connection between the existing RC beam-column and infilled PC wall panels in experimentally and theoretically. Thus, the static shear loading tests were conducted on the 6 specimens with the plate connection. Shear failure was resulted from the weakest portion of interior PC panel, exterior RC, and the connection, when the PC portion which located at the center of specimen was pulled upward from the bottom. T he experimental result was compared with analytical result from ACI 318M-14 Chapter 17 for the shear strength of post-installed anchor and PCI Handbook 7th edition 6.8 Structural Steel Corbel (PCI Design Handbook 7th edition, 2010) for the strength of cast-in H-beam. The analytical and experimental results show final failure at the same location. The failure loading of experiment showed larger than average 6% to that of the analysis.
        4,500원
        7.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Reinforced concrete shear walls are effective for resisting lateral loads imposed by wind or earthquakes. Observed damages of the shear wall in recent earthquakes in Chile(2010) and New Zealand(2011) exceeded expectations. Various analytical models have been proposed in order to incorporate such response features in predicting the inelastic response of RC shear walls. However, the model has not been implemented into widely available computer programs, and has not been sufficiently calibrated with and validated against extensive experimental data at both local and global response levels. In this study, reinforced concrete shear walls were modeled with fiber slices, where cross section and reinforcement details of shear walls can be arranged freely. Nonlinear analysis was performed by adding nonlinear shear spring elements that can represent shear deformation. This analysis result will be compared with the existing experiment results. To investigate the nonlinear behavior of reinforced concrete shear walls, reinforced concrete single shear walls with rectangular wall cross section were selected. The analysis results showed that the yield strength of the shear wall was approximately the same value as the experimental results. However, the yielding displacement of the shear wall was still higher in the experiment than the analysis. The analytical model used in this study is available for the analysis of shear wall subjected to high axial forces.
        4,000원
        8.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were experimentally performed on one unreinforced beam-column specimen and two reinforced specimens with L-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of L-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D except for the equation to predict the concrete breakout failure strength at the concrete side, principally agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.
        4,500원
        9.
        2014.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This research presents the nonlinear analysis model for reinforced concrete shear wall systems with special boundary elements as proposed by the Korean Building Code (KBC, 2009). In order to verify the analysis model, analytical results were compared with the experimental results obtained from previous studies. Established analytical model was used to perform nonlinear static and dynamic analyses. Analytical results showed that the semi-special shear wall improved significantly the performance in terms of ductility and energy dissipation as expected based on previous test results. Furthermore, nonlinear incremental dynamic analysis was performed using 20 ground motions. Based on computer analytical results, the ordinary shear wall, special shear wall and newly proposed semi-special shear wall systems were evaluated based on the methods in FEMA P965. The results based on the probabilistic approaches accounting for inherent uncertainties showed that the semi-special shear wall systems provide a high capacity/demand (ACMR) ratio owing to their details, which provide enough capacity to sustain large inelastic deformations.
        4,200원
        10.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, flexural strength properties of SC shear walls were investigated through static pushover test. Failure modes and stiffness characteristics of SC shear walls under lateral loads were inspected by analyzing the experimental results. Main failures of unstiffened SC shear walls were found to be the type of bending shear failure due to the unbonding of the steel plate at the concrete interface. The ductility capacity of SC structures was also confirmed to be improved, which is considered to be a confining effect on steel plates in the longitudinal behavior of SC shear walls.
        4,000원
        11.
        2013.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Steel plate concrete (SC) composite structure is now being recognized as a promising technology applicable to nuclear power plants as it is faster and suitable for modular construction. It is required to identify its dynamic characteristics prior to perform the seismic design of the SC structure. Particularly, the damping ratio of the structure is one of the critical design factors to control the dynamic response of structure. This paper compares the criteria for the damping ratios of each type of structures which are prescribed in the regulatory guide for the nuclear power plant. In order to identify the damping ratio of SC shear wall, this study made SC wall specimens and conducted experiments by cyclic lateral load tests and vibration tests with impact hammer. During the lateral loading test, SC wall specimens exhibited large ductile capacities with increasing amplitude of loading due to the confinement effects by the steel plate and the damping ratios increased until failure. The experimental results show that the damping ratios increased from about 6% to about 20% by increasing the load from the safe shutdown earthquake level to the ultimate strength level.
        4,000원
        12.
        2013.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, analytical models for reinforced concrete shear wall systems designed based on Korean Building Code (KBC2009) are proposed, which have special and semi-special seismic details and are compared with experimental results for a verification of analytical models. In addition, semi-special seismic details aimed to improve constructability and enhance economic efficiency were proposed and evaluated. The analytical models were performed based on nonlinear static and dynamic analysis. Through the nonlinear analyses, two seismic details showed the similar seismic behavior from the cyclic test and the analytical models for the two different seismic details represented the behavior in terms of the initial stiffness, maximum strength and strength degradation. And newly proposed seismic details(semi-special) provided with similar hysterestic behavior as well as the maximum drift.
        4,000원
        13.
        2012.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 국내에서는 원자력발전소의 모듈화 공법에 적용하기 위하여 SC(steel plate concrete) 구조를 개발하는 연구를 진행하고 있다. 이 연구에서는 전단보강이 없는 비보강 SC 전단벽의 횡방향 내진성능 및 강성특성에 대하여 분석하기 위하여 전단벽 모형시편을 제작하고, 이를 대상으로 정적가력실험을 수행하였다. 실험 결과를 이용하여, 이 논문에서는 비보강 SC 구조의 횡력에 대한 파괴모드의 유형을 분석하고, 단면강도와 부재의 강성 특성을 검토하였다. 그리고 SC 구조용 설계기준에서 제시하는 단면의 강도 계산식과실험결과를 비교하였다. 연구결과, 비보강 SC 전단벽의 파괴 형태의 하나는 콘크리트와 강판의 부착 상실로 인한 휨전단파괴라는 사실을발견하였다. SC 구조 전단벽의 벽체 길이방향 거동은 파괴 시까지 벽체 외측의 강판이 내부 콘크리트를 구속하는 효과를 기대할 수 있으므로 연성능력이 향상되는 것이 확인되었다
        4,000원
        14.
        2011.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        지진취약도 분석은 원자력 발전소의 내진성능평가를 위하여 발전되어져 왔지만, 현재는 적용성이 건물과 교량 등에도 확대되어지고 있다. 일반적으로 지진취약도 곡선은 수많은 지진가속도 기록을 이용하여 비선형 시간이력해석으로 구한다. 비선형 시간이력해석에 의한 지진취약도 분석은 구조물의 모델링과 해석에 많은 시간이 소요되는 과정을 요구한다. 비선형 시간이력해석의 이와 같은 약점을 보완하기 위해서 변위계수법과 역량스펙트럼 방법과 같은 간단한 해석방법을 지진취약도 분석에 적용하였다. 변위계수법과 역량 스펙트럼 방법을 적용한 지진취약도 곡선의 정확성을 평가하기 위하여, 철근콘크리트 전단벽 구조물에 대한 변위계수법과 역량스펙트럼 방법을 적용한 지진취약도 곡선을 비선형 시간이력해석에 의해 구해진 지진취약도 곡선과 비교하였다. 지진취약도 곡선의 작성을 위해서는 설계스펙트럼에 대응되는 190개의 인공지진과 Shinozuka 등이 제안한 방법이 적용되었다.
        4,300원
        15.
        2011.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구에서는 평면, 입면 및 구조적 특성이 다양한 철근 콘크리트 고층 아파트 건물의 고유주기를 예측할 수 있는 새로운 식을 제안하였다. 제안식은 벽체의 진동이론과 지진시 계측된 건물들의 고유주기로부터 개발 되었으며, 평면에서 다양한 방향으로 설계된 전단벽의 구조적 특성을 적절히 반영할 수 있다. 제안식의 검증을 위해 신축 중인 국내 아파트 건물 10개동의 고유주기를 측정하였으며, 측정된 고유주기는 제안식 및 KBC 2009, ASCE 7-10과 같은 기준식들과 비교 하였다. 비교 결과, 제안식은 기준식에 비해 최근의 철근콘크리트 전단벽 건물 특성을 합리적으로 반영함으로써 고유주기를 보다 정확하게 예측하는 것으로 나타났다.
        4,000원
        16.
        2008.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 전단벽-모멘트골조 시스템으로서 전단벽이 주로 횡력을 부담하는 철근콘크리트 건물을 대상으로 다양한 설치형식과 마찰력의 총량 및 분포를 갖는 마찰형 감쇠기의 제진보강 효과를 수치해석을 통해 비교 분석하였다. 감쇠기의 설치형식으로서 전단벽에 인접한 대각가새형, 벽체가 없는 골조를 보강하는 대각가새형 및 벽체 단부를 보강하는 수직경계요소형을 고려하였다. 하중기준 강화로 설계용보다 크게 증가한 지진하중에 대해 건물의 재료비선형성을 고려한 비선형시간이력해석을 수행하여 에너지소산, 횡하중 및 부재손상도 측면에서 마찰형 감쇠기의 제진성능을 비교 분석하였다. 기준마찰력의 30% 수준의 총마찰력을 갖는 벽체보강 대각가새형 설치형식이 전반적으로 가장 우수한 제진성능을 보이며,이 경우에 마찰력 배분방식은 중요하지 않았다. 또한 일부층에 집중설치함으로써 전층설치에 약간 못미치는 제진성능을 얻을 수 있었다.
        4,800원
        17.
        2007.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 하부층에 필로티 구조, 상부층에 전단벽식구조를 가진 저층 철근콘크리트 건물의 내진설계 및 내진성능 평가를 위한 기본적인 자료를 제공하는 것으로서, 비선형 지진응답해석을 실시하여 각 층의 내력과 연성율 사이의 상관관계를 파악하여, 이것들의 비율이 건물 전체의 내진성능에 어떻게 영향을 미치는가를 검토하였다. 본 연구에서는 필로티 구조를 가진 저층 철근콘크리트 전단벽식 건물의 특성을 2질점계로 치환하였으며, 하부층인 필로티 구조는 휨파괴형으로 상부층인 전단벽식 구조는 전단파괴형 시스템으로 각각 모델링하였다. 또한 각층의 복원력 특성으로는 필로티 구조는 Degrading Trilinear Model(휨파괴형), 상부층은 Origin Oriented Model(전단파괴형)을 선정하였다. 상기 복원력 특성은 각 층의 보유내력에 의하여 변화를 하며, 지진응답해석용 입력지진파로는 8개의 피해지진의 가속도 성분을 선정하여 이들 가속도 성분의 최대가속도를 0.1g, 0.2g, 0.3g로 표준화 하였다. 각각 지진강도수준에 따라 지진 응답해석을 실시하여 하부층 필로티 구조와 상부층 전단벽식 구조의 내력비와 응답 연성율 사이의 상관관계를 파악하였다. 최종적으로 특정 연성율을 위한 필로티 구조를 가진 저층 철근콘크리트 전단벽식 건물의 요구내력을 산정하여 요구내력 스펙트럼(Required Strength Spectrum)을 제안하였다. 본 연구에서 제안한 요구내력스펙트럼은 특정 지역에서 요구하는 지진수준에 대하여 지진발생시 특정 연성율 이내로 머물게 하는 하한내력의 범위를 파악할 수 있는 등, 연구결과는 필로티 구조를 가진 철근콘크리트 전단벽식 건물의 내진성능평가 및 내진설계의 기본적인 자료로서 활용 가능하다고 사료된다..2-propanedial 1.5 M 실험구에서는 실험개시시 30\;{\times}\;10^4\;cell/ml이던 것이 3 일 후 138\;{\times}\;10^4\;cell/ml였고, 실험종료시인 5 일 후에는 385\;{\times}\;10^4\;cell/ml로 증식되어 가장 높은 증식률을 보였다. 참굴 D상 유생을 대상으로 먹이효과를 조사한 결과 실험구와 대조구간 유생의 성장 및 생존율에 유의한 차이를 보이지 않았다.C에서 73.3%, 10^{\circ}C에서 63.3% 및 5^{\circ}C에서 56.7%로 수온이 30^{\circ}C 이내에서는 높을수록 높은 경향을 보였다. 염분에 따른 잠입 실험 결과는 실험 개시 300분 경과 후 염분 30 psu에서 93.3%로 가장 높았고, 35 psu에서 90.0%, 25 psu에서 83.3%, 20 psu에서 60.0%, 15 psu 이하에서는 거의 잠입이 이루어 지지 않았다. 따라서, 적정 살포를 위한 잠입률은 치패의 크기와 상관없이 저질종류는 모래 (75%) + 뻘 (25%), 입자크기는 1 mm 모래에서 높게 나타났다. 공기 중 노출시간은 짧을수록, 수온은 30^{\circ}C 이내에서 높을수록, 염분은 20-35 psu 이내에서 높을수록 잠입률이 높은 경향을 나타내었다. 교수학습모형에 관련된 지식을 묻는 내용으로 주로 출제되었다. 이에 구체적인 개선방안으로 특정 교수학습모형의 이론적 토대가 되고 전체적인 교수설계를 하기 위한 기본 바탕이 될 수 있는 교수학습이론에 관한 내용, 또한 현재가정과교육에
        4,000원
        18.
        1999.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        지진가속도에 의한 부재의 지진거동 특성은 실험적인 방법 또는 등가의 정적실험으로부터 추정되어 온 것이 대부분이다 본 연구에서는 지진가속도에 의한 철근콘크리트 전단벽체의 지진응답 및 파괴거동 특성을 유한요소법을 사용한 해석적인 기법에 의해서 예측하였다 콘크리트 부재에서 균열은 필연적으로 발생하게 되며 이로 인한 부재의 강도 및 강성의 감소 철근의 항복 및 하중의 반복성으로 인한 균열의 개폐등이 수반된다 본 연구에서는 이와 같은 콘크리트와 철근의 비선형 특성을 고려한 이축응력상태에 대한 재료모델과 동적해석 알고리즘을 범용 수치해석기법인 유한요소법을 사용하여 해석프로그램으로 구현하였다 지진가속도를 받는 전단벽을 대상으로 지진응답 및 파괴거동등을 본 연구의 해석적인 방법으로 예측하였으며 그 결과를 신뢰성 있는 연구자의 실험결과와 비교하여 그 타당성을 검증하였다.
        4,300원
        19.
        1998.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        개구부를 갖는 콘크리트 전딴팩출 뚜께가 않은 직사각형 핑판으로 모넬화 하였다 판의 두가지 경제 조건에 대한 안 정해석 칠꾀를 판좌굴제수 k료 표시하였다 경계 조건이 다른 변수로는 휩‘으로 인한 힘/떤직웅}중비 α 수펑 전단력/연 적히·중비 a 빛 게구부의 위치 및 크기 변화이다- 유한요소법에 외한 겔과륜 얻기 워하여 예제의 판을 2ï x9의 정사각 형 요소로 분할하였며 node에서 3가지 지유도를· 갖는 cn 유한요소플 택하였다? 일반적요로 개구부의 크기기 종기함 에 따라 편 깨구샤가 판 중앙에서 자유연 αree ec!ge) 요로 접근할수록 좌갈계수는 감소하는 현상윷 보이고 있따,
        4,000원
        20.
        1995.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        한 cycle 의 이력곡선 loop을 완전히 표현하기 위해서는 pinch force, drift offset, effective stiffness, 따ùoading, reloading, tangential stiffness 둥의 변수가 펼요하게 된다. 각 이력 loop에 대해 이들 변수들은 에너지 소산정도에 따라 변위와 축력의 함수로 표현될 수 있다. 본 논문에서는 먼저 16개의 전단벽 실험에서 얻어진 이력곡선 데이타를 분석하여 앞에 기술된 모든변수를 표준화된 변위(ð./ð.y) 의 함수로 표현했으며 이 를 바탕으로 이력콕선의 포락선으로 표현되는 힘-변위관계를 예측할 수 있는 6개의 step올 제시하였다. 제시 된 기볍으로 구해진 비탄성 힘 변위관계는 실험곡선과 비교되었으며 내진설계에 있어서 가장 중요한 요소중 하나인 구조물의 비탄성 힘-변위관계를 예측하는 편리한 기법으로 이용될 수 있음을 보였다.
        4,500원
        1 2