In order to understand the MR fluid flow in the MR damper core, the annular orifice path was simplified into a square channel and the electromagnetic flow was analyzed. For this purpose, the CFD-ACE+ program was used. The temperature and magnetic field of the MR fluid were based on room temperature and orifice wall data, and 2-D steady incompressible laminar flow was assumed. The inlet and outlet of the orifice channel are at atmospheric pressure, and the inflow velocity of the MR fluid is 0.1 m/s. After analyzing the magnetic field of the core, which is a simple model of the 1 stage MR damper, the electromagnetic flow analysis of the MR fluid flowing through the orifice channel was performed. From this, the magnetic field of the orifice channel and the electromagnetic flow of the MR fluid were observed. As the magnetic flux density increased, the flow distribution and velocity of the MR fluid in the channel core changed significantly.
In this study used Computational Fluid Dynamic analysis to examine NOx reduction in hydrogen combustion, analyzing six conditions with varying air/fuel ratios, temperatures, and concentrations. Results were compared between two combustor shapes and previous experimental data. Findings showed increased air/fuel ratios decreased flame temperature and increased post-combustion O2. NOx emissions peaked at high temperatures and low O2. Numerical results aligned with previous experimental trends, validating the approach. Combustor shape differences, reflecting variations in fuel and air pipes, significantly affected flow rates and combustion positions. This reduced NOx emissions up to a certain air/fuel ratio, but excessive increases diminished this effect. The study highlights the complex relationship between combustor design, operating conditions, and NOx emissions. Further research is needed to optimize NOx reduction by considering pipe numbers and combustion locations. Future studies should explore various combustor geometries, fine-tune air/fuel ratios, and investigate additional parameters influencing NOx formation and reduction in hydrogen combustion systems.
A cyclone separator is a device that separates solid particles from a fluid using centrifugal force and gravity in its inner chamber. Among cyclone separators, the separator that uses water as a working fluid is called as hydrocyclone separator, which has been developed for the purpose of dehydrating solid mixtures with a proportion of solids floating in liquids greater than 1, such as soil, coal, and cement slurry. In this paper, a hydrocyclone was designed based on the previously proposed design method, and how different the performance is from the targeted value was investigated using the computational fluid dynamics.
유체-구조물-지반 상호작용을 고려한 액체저장탱크의 유한요소 모형을 제시하고, 비선형 지진응답 해석기법을 정식화한다. 탱크 구조물은 기하 및 재료 비선형 거동을 고려할 수 있는 쉘 요소로 모델링한다. 유체의 거동은 acoustic 요소로 구현하고, interface 요소 를 사용하여 구조물과 결합한다. 지반-구조물 상호작용을 고려하기 위해 지반의 근역과 원역을 각각 solid 요소와 perfectly matched discrete layer로 모델링한다. 예제 20만 kl급 액체저장탱크의 지진취약도 해석에 적용하여, 유연한 지반에 구조물이 놓인 경우 부지에 서의 암반노두운동의 증폭 및 필터링으로 인해 지진취약도의 중앙값과 대수 표준편차가 감소하는 것을 관찰할 수 있다.
This study performed the seismic response analysis of an LNG storage tank supported by a disconnected piled raft foundation (DPRF) with a load transfer platform (LTP). For this purpose, a precise analytical model with simultaneous consideration of Fluid-Structure Interaction (FSI) and Soil-Structure Interaction (SSI) was used. The effect of the LTP characteristics (thickness, stiffness) of the DPRF system on the seismic response of the superstructure (inner and outer tanks) and piles was analyzed. The analytical results were compared with the response of the piled raft foundation (PRF) system. The following conclusions can be drawn from the numerical results: (1) The DPRF system has a smaller bending moment and axial force at the head of the pile than the PRF system, even if the thickness and stiffness of the LTP change; (2) The DPRF system has a slight stiffness of the LTP and the superstructure member force can increase with increasing thickness. This is because as the stiffness of the LTP decreases and the thickness increases, the natural frequency of the LTP becomes closer to the natural frequency of the superstructure, which may affect the response of the superstructure. Therefore, when applying the DPRF system, it is recommended that the sensitivity analysis of the seismic response to the thickness and stiffness of the LTP must be performed.
Passengers on public buses operating in the metropolitan area are exposed to the closed indoor air for minutes to hours. The indoor air quality of buses is mostly controlled through ceiling-mounted ventilation and filtration devices. A simulation study using a commercial code was conducted for fluid flow analysis to evaluate the potential effectiveness of an air purifier that can be inserted into bus windows to supply clean air from the outside to the inside. As a result of field measurements, the average CO2 concentration inside the bus during morning and evening rush hours ranged from 2,106±309 ppm to 3,308 ± 255 ppm depending on the number of passengers on board. This exceeded the Guideline for Public Transportation. The optimal installation position of an air purifier appeared to be the front side of the bus. In fact, even a low diffusing flow velocity of 0.5m/s was effective enough to maintain a low concentration of CO2 throughout the indoor space. Based on numerical analysis predictions with 45 passengers on board, the maximum CO2 concentration in the breathing zone was 2,203 ppm with the operation of an air purifier.
The importance of urban green space creation is increasingly recognized as the most realistic and efficient approach for fine dust mitigation in urban areas. Particularly considering the characteristics of domestic cities, the application of buffer green spaces along roads can maximize the efficiency of fine dust reduction without the need for separate green space creation. Accordingly, this study analyzed the fine dust mitigation effects based on the types of plantings in the central dividers and roadside trees in Jeonju City, Jeollabuk-do. To do this, we controlled various external variables of urban space and considered the planting arrangement types in the central dividers, carrying out the analysis using a CFD simulation. The simulation results confirmed that the central dividers with plantings demonstrated more effective ultrafine dust reduction than those without. Moreover, the arrangement of roadside trees showed a greater ultrafine dust reduction effect when adopting a multilayered structure compared to a single layer. Based on these findings, we concluded that installing both trees and shrubs simultaneously in the central dividers and along roads was effective for ultrafine dust mitigation. On this basis, we quantified the dust reduction effects of plants in urban street environments and proposed planting guidelines for roadside green spaces to improve air quality.
Microclimate analysis was conducted through actual measurement according to land use status in urban, and CFD analysis was conducted to analyze and predict the microclimate characteristics of urban, and compared and analyzed with the actual measurement results. It was measured in high-rise areas and parks, and the temperature of the park area was 0.4 to 0.6℃ lower, and the relative humidity was 1.0 to 3.0% higher. The correlation coefficient was obtained by comparing the results of the computational fluid analysis with the results of the computational fluid analysis at the actual location located within the CFD analysis area for validation. The seasonal correlation coefficients are all higher than 0.8, so it is judged that they can be applied to microclimate analysis in urban area. The computational fluid analysis was divided into three areas (low-rise, low and high-rise, and high-rise) centered on the A2 point. On average, the low-rise area was 0.1 to 0.4% higher than the high-rise area. In the low and high-rise area and high-rise area, the pith of buildings are wide, so the airflow is smooth, so it is judged that the temperature is relatively low.
This paper proposes a method to evaluate the structural safety of a large wide-width greenhouse structure against wind load caused by a typhoon through a fluid structure interaction analysis technique. The conventional method consisted of roughly estimating the wind load based on the relevant laws and regulations, and determining safety through structural analysis. However, since the wind load changes nonlinearly according to the wind speed distribution and wind direction around the greenhouse and the external shape of the structure, there are many uncertainties in the existing structural safety evaluation method, and it is difficult to accurately determine the design margin. In this study, a systematic method was developed to accurately calculate the wind load acting on a greenhouse structure and evaluate structural safety by considering the characteristics of wind through a fluid structure interaction analysis using coupled computational fluid dynamics and computational structural mechanics. Using the proposed method, it is possible to significantly reduce the manufacturing cost because it is possible to obtain an optimal design that reduces the over-conservative design margin while securing the structural strength of the greenhouse.
Micro-climate measurements and computational fluid analysis were conducted to use it as basic data for the preservation and management of the old house of Kim Myung-kwan, a traditional building that is National Folk Cultural Property No. 26. As a result of the actual measurement, the temperature and humidity are relatively evenly distributed indoors unlike outdoors, but the temperature and humidity vary depending on the time change and the installation location in the outdoors. It was found that the temperature increases after dawn and the temperature varies depending on the installation position around 14:00–15:00, when the temperature becomes the highest. In particular, the temperature was high at the outdoor measurement point adjacent to the building and the fence. As a result of the computational fluid analysis, the temperature was high in the buildings and fences in the old house or in the area adjacent to the building, and it was about 1℃ higher than the surrounding area. In this area, it is judged that the thickening of wood will occur more severely than in other locations, and special preservation management is required.
A simplified method for earthquake response analysis of a rectangular liquid storage tank is proposed with fluid-structure interaction considered. In order to simplify the complex three-dimensional structural behavior of a rectangular liquid storage tank, it is assumed that structural deformation does not occur in the plane parallel to the direction in which the earthquake ground motion is applied but in the plane perpendicular to the direction. The structural deformation is approximated by combining the natural modes of the simple beam and the cantilever beam. The hydrodynamic pressure, the structure’s mass and stiffness, and the hydrodynamic pressure’s added mass are derived by applying the Rayleigh-Ritz method. The natural frequency, structural deformation, pressure, effective mode mass, and effective mode height of the rectangular liquid storage tank are obtained. The structural displacement, hydrodynamic pressure, base shear, and overturning moment are calculated. The seismic response analysis of an example rectangular liquid storage tank is performed using the proposed simplified approach, and its accuracy is verified by comparing the results with the reference solution by the finite element method. Existing seismic design codes based on the hydrodynamic pressure in rigid liquid storage tanks are observed to produce results with significant errors that cannot be ignored.
Failure to comply with the performance test requirements for the centrifugal pumps at power plants often results in performance dissatisfaction as a result of field tests. This study proposed a method of reducing the uncertainty of the field test results by evaluating the systematic error in the measurement system caused by failure to follow the test requirements using the computational fluid dynamics(CFD) technique. As a result of the evaluation of the systematic error and reflecting it in the performance test data, it was confirmed that the error occurred at a constant rate with respect to the flowrate and that the pump, which showed a difference in performance actually had the same performance.
In order to analyze the pressure drop of the fluid passing through the hydraulic coupler, a flow model using the Computational Fluid Dynamics (CFD) analysis technique was developed and the fluid flow rate and pressure distribution inside the coupler were analyzed. The analysis model was corrected by comparing the pressure drop measurement using a 6.35mm hydraulic coupler with the ISO reference value and the simulation prediction value. Using the calibrated model, the flow rate and pressure drop of 13 types of hydraulic couplers distributed on the market were analyzed, and their performance was determined by comparing them with ISO reference values. In the case of type A coupler, the pressure drop was generally higher than the ISO reference value, and in the case of type B coupler, the pressure drop was similar to or lower than the ISO reference value. It was confirmed that the complex flow analysis inside the hydraulic coupler could be easily performed through computational fluid dynamics (CFD) modeling, and based on this, problems could be identified and performance could be improved performance.
Valves are one of the indispensable components in modern industry. Filling and de-pressure connectors in rocket valves used for space launch vehicles are very important parts for smooth fluid supply. For this reason, an optimized design that can improve efficiency, miniaturization, weight reduction, and safety of the valve at the same time is required. In this work, flow analysis and structural analysis were performed through 3D modeling using computational numerical analysis for open type filling and de-pressure valves. As results, the flow velocity and pressure distribution of the fluid were analyzed through the flow analysis of valve, and stress distribution was conducted in structural analysis. Through this study, it is consequently expected to provide valves of various specifications by performing production and performance test evaluation of development prototypes.
Among the various causes of the vibration problem of the radial sluice gate used in Saemangeum, the effect of flow-induced vibration was studied by the method of computational fluid analysis. In this study, the effect on the flow-induced vibration of the Saemangeum radial sluice gate was evaluated by 2D unsteady flow numerical analysis using ANSYS Fluent. Gate opening cases of 0.2m, 0.3m, 0.4m, 0.5m, and 1.0m were analyzed. As a result, the flow-induced vibration characteristics due to the instability of turbulent flow were observed through FFT analysis. As the gate opening increases, the frequency of the maximum amplitude moves gradually to a lower frequency region with the reduction of the magnitude. Therefore the flow-induced vibration effects can be considered as small with the gate opening increase.
In general, small and medium-sized computer rooms do not have access floors for reasons of increased floor height and increased construction cost. Therefore, the air conditioning method used here applies the method of directly blowing the cold air of the air conditioner into the computer room. In this case, the hot/cold air is not separated, and as the hot air is recirculated, it is re-introduced to the front of the server rack, resulting in a problem that the server cooling efficiency is decreased. In addition, in such a computer room structure, it is difficult to configure and install a containment system. In this study, we tried to understand the problem of the formation airflow in the case of using the existing air conditioning method, and to find a method of configuring the air conditioning environment to improve the cooling efficiency. The purpose of this study was to understand the airflow/temperature distribution in the computer room using the CFD simulation method. In addition, the thermal characteristics of various air-conditioning environments such as the location of the CRAC cold air discharge location, the layout between server rack and CRAC and the containment were reviewed.
When operating at high speed on a vessel, a high-speed planing hull occurs nonlinear movements such as stern trim and large sprays. This phenomenon results in the hindrance of stability, embarkation and mission performance. Excessive stern trim during the slides decreases propulsion efficiency and visibility of helmsman due to porpoising and changing the attack angle of the fluid flowing into the propeller. To improve these problems, an outboard floating plate is installed on the cavitation plate to greatly suppress or eliminate the porpoising phenomenon. In this study, to analyze the performance of the floating plate mounted on the outboard engine, numerical analysis was carried out to investigate the resistance applied to the floating plate and the lift generated according to the change of the angle of attack and the flow velocity. The reliability of the floating plate mounted on the outboard engine was verified by applying the floating plate according to the speed and the angle of attack.