        61.
        2013.11 서비스 종료(열람 제한)
        This is aim to use and recycle the wasted heat from the dispose process of the incineration plant facility in Daegu. Furthermore, the saturated vapor is to be supplied for the Industrial Complex as energy resource. It is to receive the superheated steam that shows 250℃ temperature and 18kg/cm² steam pressure from the Boiler system of the incineration plant facility. This condition is not suitable for end-users’ specification of the manufacturing process. The Desuperheater is to be researched and developed for controlling high temperature and steam pressure. It is necessary to calculate condition of product vapor for establishing the steam network with water cooling and condensate system. The Heat Reclaiming Steam Arising System is to reduce the temperature to 220℃ and increase the pressure to 22kg/cm² at the final point of product supply line. It is expected Environmental and Economical effects with establishing optimum network for the use of waste heated vapor. Environmentally, it could reduce the Global Warming Potential, use fossil fuel and Green-house gases. Economically, it will bring down the production cost of end-users by using the wasted heated vapor.
        64.
        2011.08 KCI 등재 서비스 종료(열람 제한)
        본 연구는 인천 게임산업단지 조성을 통한 경제적 파급효과를 분석하는데 있다. 게임산업은 문화콘텐츠 산업으로서 큰 잠재가능성을 가지고 있어, 발전에 대한 당위성이 높다는 다양한 의견을 가지고 있음에도 불구하고, 이에 대한 경제적 파급효과를 분석한 사례는 거의 없는 실정이었다. 따라서 본 연구는 이를 선험적으로 분석하는 측면에서 연구에 대한 의의를 가질 수 있다. 이의 분석을 위해 인천경제자유구역내에 게임산업단지를 설립하는 경우를 가정하고 건설부문, 게임관련 제조업 및 게임관련 서비스업을 토대로 지역산업연관분석을 실시하였다. 본 연구의 결과를 통해 게임산업이 지역 및 국가에 미치는 중요성을 직접적으로 파악할 수 있으며, 향후 이와 관련한 연구의 방향에 큰 영향을 미칠 수 있을 것이다.
        65.
        2011.07 KCI 등재 서비스 종료(열람 제한)
        Objectives: This study is aimed at identifying the influential factors on the pulmonary function of ordinary residents in the surrounding areas of Yeosu Industrial Complex. Methods: The PFT (Pulmonary Function Test) was conducted on the target residents numbering 989 people (male 361, female 628). The exposed group (813 people) resided within the radius of 5km from Yeosu Industrial Complex and the control group (176 people) resided in the radius of more than 15 km from May 2007 to November 2007. The survey also took into account other factors including personal characteristics, life habits, respiratory diseases and allergic symptoms, medical histories, and the living environments of the residents in order to further identify influential factors on pulmonary function. Result: When comparing the PFT values of the exposure groups to the control group of the same city, values of the exposure groups were meaningfully lower with an %FEV1 of 107.05% and %FVC of 100.28%. Conversely, the control group reported an %FEV1 and %FVC of 107.26% and 102.85% respectively, indicating that ambient air pollutants reduce lung function. The odds ratio of asthma diagnosis history increased when a subjects residence was close to a heavily trafficked road, traffic amount was huge, a bed was used, and the family had less than four members. However the results were not statistically meaningful. The odds ratios of abnormal pulmonary function were statistically higher among those with asthma(OR=4.29, CI=1.75-10.56), wheezing (OR=2.59, CI=1.24-5.41), and nasal congestion (OR=2.87, CI=1.36-6.08) (p<0.01). The factors affecting FEV1 were symptoms including asthma, passive smoking and allergic eye disease (R2=0.049, p<0.001). For the FVC symptoms including asthma (R2=0.014, p<0.001) were measured. The analysis showed that FVC decreased with increases in O3 and CO(p<0.01). Furthermore, FEV1 decreased with increases in O3(p<0.01). Conclusions: These results will provide preliminary data for establishing responsive measures to protect the health of residents in industrial complexes from air pollution, and to develop lasting environmental health policies.
        67.
        2008.08 KCI 등재 서비스 종료(열람 제한)
        정부는 지역제조산업 육성을 목적으로 기존 부지를 개선 확장하거나 해안지역 매립을 통하여 신설하는 방향으로 산업단지조성을 위한 정책을 펼치고 있다. 따라서, 물리적 환경적인 특성의 관점에서 해안지역매립으로 인한 영향의 분석은 반드시 필요하다. 본 논문도 임해지역 국가산업단지 조성에 따른 영향을 인근 해역의 해양물리적 특성, 퇴적 및 확산 체계 변화, 해양환경 변화 등의 현상을 현장관측조사 및 수치시뮬레이션을 통하여 분석하고자 한다. 적용대상역은 울산광역시의 온산국가산업단지 인근의 해안선경계역이다. 검증을 위해 조석, 조류 및 퇴적에 관한 기존의 관측자료를 확보하였으며 일부 특정지점에서는 현장관측도 수행하였다. 검증한 모델로 실제대상해역에 적용하고 장래변화를 분석하였다.
        68.
        2008.05 KCI 등재 서비스 종료(열람 제한)
        5 public complaint areas against odor in Changwon Industrial Complex were selected and investigated to clear up the cause of the complaint. 16 companies operated in public complaint areas were visited and had a grip of their situation about odor generation and treatment. Two samples at it's site boundary of each company were taken to measure complex odor unit. Complex odor unit at the site boundary of investigated companies in the public complaint areas, for the most part, exceeded standard(odor unit 20) in industrial area. It was due to that this area was not designated as odor control region and that there are also many problems in current laws of Odor Protection Act, Air Quality Act and regional legislation. Accordingly, It will be necessary to revise the related legislation, to organize governance, to financially support the improvement of environmental facilities and to enforce guidance and the regulation rigidly for the odor emission reduction in Changwon Industrial Complex.
        69.
        2005.03 KCI 등재 서비스 종료(열람 제한)
        The research in this paper was carried out to examine the BTEX(Benzene, Toluene, Ethylbenzene, Xylene) concentrations in Seongseo Industrial Complex. These compounds are the major constituents, more than 60% in composition of total VOCs, mainly charging in ambient air. BTEX samples were collected from the 38 sites, 10 for the source points and 18 for the boundary sites, and were analyzed by canister-GC/MS. The mean concentrations of BTEX were 33 ppbv for benzene, 214 ppbv for toluene, 89 ppbv for ethylbenzene, 77 ppbv for xylene. Among the BTEX, toluene had the highest concentration in the source points and boundary sites. In the source points, BTEX concentration of incineration facility for hazardous wastewater appeared highly in the range of 220~350 ppbv. BTEX concentrations in source boundary sites appeared in the order of toluene>ethylbenzene>xylene>benzene. As a result of the correlation analysis, the concentration of the source points was related to those of the boundary sites. Correlation of ethylbenzene and xylene was presented to 0.7991(P<0.01), 0.6329(P<0.05) as the correlation coefficient, respectively.
        70.
        2005.02 KCI 등재 서비스 종료(열람 제한)
        The importance of atmospheric conditions for the assessment of an air pollution situation has been demonstrated by their influence on the various compartments of an air pollution system, comprising all stages from emission to effects. Especially, air pollutants dispersion phenomenon are very sensitive according to wind data. But the discussions of how to apply representative meteorological data in air pollution dispersion model are not frequent in Korean environmental assessment processes. In this study, we investigated the difference of air pollutants dispersion phenomenon using U.S EPA ISCLT3 model according to applying the different meteorological data observed at two points for Seongseo industrial complex of Daegu. Two points are the spot site of Seongseo industrial complex and Daegu meteorological observatory. The winds speed of the spot site were smaller than those of Daegu meteorological observatory. In the winter season, the differences came to about 64% for the period(1 February 2001~31 January 2002). Wind directions were also fairly different at two points. The air pollutants dispersion phenomenon estimated from our numerical experiments were also fairly different owing to the meteorological conditions at two points.
        71.
        2005.01 KCI 등재 서비스 종료(열람 제한)
        As a typical example of simultaneous analysis of the odorous compounds, the volatile organic compounds from inventory sources in Seongseo industrial area were concentrated and analyzed with thermal desorber/GC/ MSD, and major malodorous compounds were estimated. Odor intensity and odor concentration was analyzed simultaneously During a period from November in 2002 to December in 2003, this study was conducted to evaluate malodor emission characterization in major treatment facilities. The major components were Dimethyl sulfide, Dimethyl disulfide, Methyl mercaptane, Ammonia, Benzene, Toluene, m,p-xylene, o-xylene, Styrene, 1,2,4- T.M.B and 1,3,5-T.M.B. Among the six major inventory sources, the odor unit concentration of Night-soil disposal facilities was the highest, 669~2344 ou/m3.
        73.
        2004.06 KCI 등재 서비스 종료(열람 제한)
        Air pollution from the Daegu industrial complex (DIC) in Korea has been a common nuisance and cause of complaints for nearby residents. The current study measured the indoor and outdoor levels of six VOC (benzene, toluene, ethylbenzene, and three isomeric xylenes) at two residential areas with a different proximity to the DDIC, plus the ambient levels at two industrial areas within the boundary of the DDIC. The QA/QC program included the range of correlation coefficient (0.94~0.99) for calibration curves, within the permissible range. Toluene was the most abundant VOC in the ambient air both in residential and industrial areas. Both indoor and outdoor air concentrations of all target VOC except benzene were higher in residential area near the DIC compared to that further away from the DIC. Moreover, the ambient air concentrations of all target VOC except benzene for two industrial sites (A and B) were significantly higher than the outdoor or indoor air concentrations in the two residential areas. The findings further suggested that VOC ambient levels measured in a residential area near the DIC be used as a potential indicator of odor-causing unidentified air pollutants transported from the DIC. Moreover, it was found that the elevated ambient toluene levels outweighed the indoor sources with respect to the environmental exposure of residents nearby the DIC. However, in the residential area further away from the DIC, the toluene indoor sources outweighed the outdoor sources.
        74.
        2004.03 KCI 등재 서비스 종료(열람 제한)
        This study focuses on the measurement of airborne Volatile Organic Compounds (VOCs) in the Kumi electronic industrial complex during the time periods of August and September, 2002 and January and February, 2003. This study was based on the US-EPA method TO-14 while the VOCs were analyzed with GC/MSD. The toluene level revealed high concentration at all measurement sites. The areal rank of average concentrations of VOCs is as follows : industry1>industry2>urban>middle>residential. Concentrations of VOCs in Kumi electronic industrial ones were generally higher than at Yeochon and Ulsan industrial complexes. Dichloromethane and trichloroethylene, which are used as a cleaner in the process of electronic industries, were observed 4 to 8 times higher than those of other areas. Among the aromatic compounds, toluene showed the highest level, while the concentrations of dichloromethane and trichloroethylene were higher than those of other halogen compounds. In Kumi, toluene, trichloroethylene, and dichloromethane were confirmed as the major compounds of VOCs by this research.
        75.
        2000.04 KCI 등재 서비스 종료(열람 제한)
        This study is focused on the industrial symbiosis based on industrial ecosystem theory. At first, the concept of industrial ecosystem was introduced. Industrial symbiosis is a good tool in order to make a harmony between industry and natural ecosystem. The good example of industrial symbiosis is the case of Kalundborg in Denmark, where 11 networks are working in four enterprises and one community nearby. It was proved that savings of natural resources and economic benefit are achieved by use of industrial symbiosis. Moreover, the control of pollutant emission was also done by use of advanced technology and investments. Based on this case, It was shown that industrial symbiosis through eco-industrial complex in Korea was confronted with many difficulties. First of all, loose emmision criteria, recycling system on wastes, and the absence of will for industrial symbiosis should be solved in Korea.
        76.
        1999.08 KCI 등재 서비스 종료(열람 제한)
        We will calculate concentration of air pollutants using ISCST3, FDM and AERMOD of models recommended in U. S. EPA which are able to predict concentration of short term for point source, complex like industrial complex, power plant and burn-up institution. Before executing model, as analyzing computational result of many cases according to selecting of input data, we will increasing predictable ability of model in limit range of model. Especially, we analyzed three cases - case of considering various emission rate according to time scale and not, case considering effect of atmospheric pollution materials removed by physical process. In our study, after comparing and analyzing results of three model, we choose the atmospheric dispersion model reflected well the characteristic of the area. And we will investigate how large the complex pollutant sources such as industrial complex contribute to atmospheric environment and air quality of the surrounding the area as predicting and estimating chosen model.
        77.
        1998.03 KCI 등재 서비스 종료(열람 제한)
        For efficient development of rural facilities, choice of their optimum locations would be an important issue, however, existing research works concentrated much more an allocation policy of urban industrial complex and public facilities than rural ones. In this study, because agricultural-cum-industrial complex has been the most widely developed representative one of rural facilities, it was selected as a case study facility. As a pre-study to system development, existing governmental location-decision system was checked and interviewing survey carried out to find out on-spot problems. And, being based on literature review and survey analysis results, 4-step optimum locational decision model was developed , formulation of locational goal system, ranking tabulation on components, determination of significance values of components, calculation of component scores. Finally, through the case study works on 3 sites, system applicability was checked, Considering together the simplicity problem of existing guidelines and the interviewing survey results favoring the diversified viewpoints, it would be necessary to develop multifaceted support system for locational decision making. 3-tier classification steps from the higher, middle to lower one were used and their underpinning viewpoints were sorted as on regional development, entrepreneurship, spatial rationality, from which a tentative locational goal system was formulated. Through the expert group checking, final locational goal system was determined having 3 of the higher classification items, 7 of the middle ones, 23 of the lower ogles. For ranking tabulation, 3 types of ranking criteria were arranged which were based on statistical analysis using mean and standard deviation(Type I ), its existence or not 1 good or not(Type E ), and the others(Type E ). From the significance evaluation results, regional development and entrepreneurship aspects were valued much higher than spatial rationality aspect. And, in the middle step, items as spread effects of regional economy, accessibility and social potentialities were highly valued while infrastructural development level and natural condition being low. The application results of the system to 3 case study total. However, the detailed ones differed among study the influencing effects on regional economy, and contrast greater the infrastructural development level. Conclusively, final evaluation values well represented the characteristics of each area. If this system be complemented and applied comprehensively by the successive studies, it would be developed to a general model of locational decision supporting system for rural facilities.
        78.
        1997.06 KCI 등재 서비스 종료(열람 제한)
        Mercury- and cadmium-resistant bacteria were isolated from an industrial complex wastewater of Taejon area. All of them were motile, gram negative rods. In the results of physicochemical test and VITEK card test, HMI was identified with Acinetobacter calcoaceticus, CM3 was identified with Comamonas acidovorans, HM2, HM3, CM1, and CM4 were Pseudomonas sp., but HM4 and CM2 were unidentified. They were tested for susceptibility to 14 heavy metals. Mercury-resistant bacteria(HM1, HM2, HM3, and HM4) were sensitive to low concentration(100∼400ppm) of Cd^2+, Co^2+, Zn^2+, and Ni^2+ while cadmium-resistant bacteria(CM1, CM2, CM3, and CM4) showed resistance up to the high concentration(600∼1,200ppm) of these metal ions. As a result of resistance spectrum test of mercury-resistant bacteria, HM1 was broad-spectrum strain, HM2, HM3, and HM4 were narrow-spectrum strains. Transmission electron microscopic examination of cell wall of HM1 culture grown with and without 100ppm of HgCl_2 showed remarkably morphological abnormalities. In the result of atomic absorption spectrometric analysis of cadmium-resistant bacteria grown at 200ppm of CdCl_2 for 6h, all of them accumulated cadmium(14ppm∼57ppm) in cell. In cadmium-resistant bacteria, CM1, CM2, and CM4 were spared from the inhibitory effect of Cd^2+ by the addition of Mn^2+, CM4 were also spared from the inhibitory effect of Cd^2+ by the addition of Mn^2+ as well as Zn^2+.
        79.
        1993.06 KCI 등재 서비스 종료(열람 제한)
        콩의 생육 및 수량에 미치는 대기 중 아황산가스의 영향을 평가하고자 공업단지 주변에서 아황산가스의 농도 측정, 밭토양의 특성조사 및 콩의 생육 및 수량을 조사한 결과를 이용하여 콩의 생육기간중의 아황산가스의 등 농도곡선을 작성하고 이를 이용한 콩의 생육과 수량에 미치는 아황산가스의 영향과 토양 pH의 영향을 검토한 결과는 다음과 같다. 1. 조사지역의 콩의 주요 생육기간인 7월중순부터 9월중순까지의 아황산가스의 평균농도는 77mg /100cm2 PbO2 /day였다. 2. 콩의 수량감소율은 5~30% 정도였으며, 7월중순부터 9월 중순까지의 아황산가스농도와 수량과는 유의 한 부의 상관관계 (r=-0.846**)를 보였다. 7월 16일부터 8월 9일까지의 아황산가스의 농도와 주당 협수 및 100립 중, 8월 9일부터 9월 17일까지의 아황산가스의 농도와 100립중과는 유의한 상관관계를 보이지 않았다. 3. 조사지역의 토양 pH는 4.2~6.5였으며, 토양의 pH와 수량과는 正의 상관관계(r=0.813**)를 보였으며, 석회시용으로 토양 pH가 교정된 곳에서는 아황산가스에 의한 수량감소가 적었다. 4. 콩의 수량 형성에 미치는SO2 의 영향은 만성적, 누적 적으로 나타났고, 아황산가스의 등농도 곡선으로 콩의 수량감소 예측이 가능하였다.
        80.
        1992.03 KCI 등재 서비스 종료(열람 제한)
        A study on the changes of the oceanographical environment caused by Mokpo coastal zone development was carried out. Special emphasis was placed on the clarification of the water level changes and coastal current structure and influence of the environmental factors on the coastal area. In order to understand the structure oceangraphical environemnt, such as water temperature, salinity, suspended solids, pH, dissolved oxygen, chemical oxygen demand, biochemical oxygen demand, distribution of bottom sediment, tide and current were measured. To investigated the structure of tide and current for the future development, a numerical analysis was carried out. In certain zones, it was found to be flooding problems near the lowlying commercial area.
        1 2 3 4 5