In this paper, the instability of the domed spatial truss structure using wood and the characteristics of the buckling critical load were studied. Hexagonal space truss was adopted as the model to be analyzed, and two boundary conditions were considered. In the first case, the deformation of the inclined member is only considered, and in the second case, the deformation of the horizontal member is also considered. The materials of the model adopted in this paper are steel and timbers, and the considered timbers are spruce, pine, and larch. Here, the inelastic properties of the material are not considered. The instability of the target structure was observed through non-linear incremental analysis, and the buckling critical load was calculated through the singularities and eigenvalues of the tangential stiffness matrix at each incremental step. From the analysis results, in the example of the boundary condition considering only the inclined member, the critical buckling load was lower when using timber than when using steel, and the critical buckling load was determined according to the modulus of elasticity of timber. In the case of boundary conditions considering the effect of the horizontal member, using a mixture of steel and timber case had a lower buckling critical load than the steel case. But, the result showed that it was more effective in structural stability than only timber was used.
Middle size of membrane retractable roof is under 25m span which consists of various moving systems. Sliding carriage is the system that leads the membrane to parking place, transferring the load from the membrane to structural cable. When membrane moves roof, thus, structural behavior of sliding carriage, which may contain various shapes with friction coefficients, should be investigated by vertical load as well as horizontal load. Nummerical simulation of sliding carriage prototypes, in this research, were performed by incrementation of vertical load and horizontal load as well. Consequently, this paper evaluated proper shapes of inner holder of Sliding carriage and evaluated the effective contact area of inner hold.
본 연구에서는 경북 지역에 분포하는 소나무림을 대상으로 수관연료의 수직적 구조, 수관연료밀도를 파악하고, 여러 가지 변수를 이용한 수관층 각 부위별 연료량 추정식을 개발하고자 하였다. 본 연구 결과에 의하면, 수관층 연료의 수직적 분포 형태는 방추형으로 상대적 높이 비율 0.6~0.8 구간에 가장 많은 연료가 분포하였으며, 0.4 이하의 수관 하단부에는 주로 고사된 가지가 분포하고 0.8 이상부터 상단부로 갈수록 연료가 적어지는 형태를 보였다. 전체 수관에 대한 연료밀도는 평균 0.38kg/㎥이었으며, 이 중 산불 발생 시 쉽게 탈 수 있는 연소가능한 연료의 밀도는 0.21kg/㎥이었 다. 수관 특성 중 수관길이와 수관폭을 이용하여 수관층 연료량 추정식을 개발한 결과 조정결정계수(R2adj)의 범위는 0.56~0.79이었으며, 수관길이와 수관폭을 변수로 함께 사용하였을 경우 조정결정계수(R2adj)가 더 높은 값을 보였다. 본 연구의 결과는 임목에 대한 산불 연료적 관점에서의 다양한 정보를 제공할 뿐만 아니라, 영상자료를 활용하여 수관층 연료량을 추정하는데 활용될 수 있다.
In this paper, the dynamic snapping of the 3-free-nodes spatial truss model was studied. A governing equation was derived considering geometric nonlinearity, and a model with various conditions was analyzed using the fourth order Runge-Kutta method. The dynamic buckling phenomenon was observed in consideration of sensitive changes to the force mode and the initial condition. In addition, the critical load level was analyzed. According to the results of the study, the level of critical buckling load elevated when the shape parameter was high. Parallelly, the same result was caused by the damping term. The sensitive asymmetrical changes showed complex orbits in the phase space, and the critical load level was also becoming lowly. In addition, as the value of damping constant was high, the level of critical load also increases. In particular, the larger the damping constant, the faster it converges to the equilibrium point, and the occurrence of snapping was suppressed.
Recently, the occurrence frequency of earthquake has increased in Korea, and many cultural assets have been damaged. Cheomseongdae is a valuable cultural assets that must be preserved historically and culturally. But, the masonry structure such as Chemseongdae is vulnerable to lateral forces. Therefore, in this study, structural modeling and dynamic analysis are performed to reflect the ground state and structural form of Cheomseongdae. Also, discrete element analysis technique is applied and dynamic behavior characteristics are analyzed according to earthquake load. For this purpose, displacements and stresses according to locations are reviewed and then swelling and distortion are analyzed.
The objective of this numerical study is to investigate the effect of shaft part’s diameter on the load distribution, under-fill, and metal-flow line characteristics in tubular & solid shaft yoke of Al-IMS. The outer diameter of tubular shaft yoke was changed from 30mm to 35mm, and the shaft diameter of solid shaft yoke was varied from 20mm to 25mm. In this results, the required load for production was linearly increased with increasing the tubular shaft yoke outer diameter. In the solid shaft yoke, the loads for the shaft part extending process were almost constant by 10,000kg, however, the loads for generating the yoke process, which were needed a lot of strain, were increased by 4,000kg with increasing the diameter of shaft part. The under-fill regions according to diameter of the shaft part were not observed in both products, and the metal-flow lines were also straight without folding phenomena.
베일의 시장 판매를 위해서는 표준화된 품질과 상품의 정량화가 선행되어야 하며, 이를 뒷받침하기 위해 베일의 정량화가 가능한 베일러 개발이 필요하다. 베일의 크기보다 중량을 기준으로 정량화할 경우 수확물의 생산 조건과 관계없이 베일의 일정한 규격화가 가능해진다. 이러한, 중량기준 정량화가 가능한 베일러의 개발을 위해 가장 중요한 요소기술들 중 하나가 바로 가변 중량 측정 시스템이다.따라서 본 연구에서는 중량 가변이 가능한 베일러의 기초 연구로써 트레일러의 3점에 로드셀을 설치하여 트레 일러에 적재되는 내용물의 하중이 3점의 로드셀에 의해 모두 지탱되도록 플로팅 타입의 하중 측정 시스템을 구성하였다. 이를 이용하여 정적 하중과 동적 하중을 측정함으로써 하중 측정 시 발생하는 문제점 들을 파악하고, 중량 감응형 베일러 개발의 기초자료로 활용하기 위하여 연구는 수행되었다.그 결과 정적 측정 신호와 동적 측정 신호의 지배적인 주파수 성분은 각각 0∼0.5Hz와 0∼0.1Hz에서 발생하였으며, 사용된 전원으로 인한 60Hz의 주파수 성분과 시스템의 이동 시 지표면의 굴곡, 엔진의 구동 등으로 인하여 진동이 발생하였다. 그래서 이러한 노이즈를 제거하기 위하여 저주파 통과 필터(3 Order, Butterworth type, Cutoff frequency 0.1Hz)를 사용하였다. 편심 하중에 따른 측정 신호의 분석 결과 편심 하중은 하중 측정에 영향을 주지 않으며, 시스템의 이동속도 3.47km/h와 6.21km/h에서 측정된 하중과 예측 하중을 비교한 결과 각각 -2.42kgf와 -1.71kgf의 평균 하중 오차를 보였다. 즉, 시스템의 이동속도는 하중 측정에 영향을 미치지 않았으며, 추후 중량 감응형 가변 베일러에 본 시스템을 적용하 기 위해서는 실제 베일러의 기계적 진동과 비 진동 요인들을 규명해야 한다.
The arched stone bridge has been continuously deteriorated and damaged by the weathering and corrosion over time, and also natural disaster such as earthquake has added the damage. However, masonry stone bridge has the behavior characteristics as discontinuum structure and is very vulnerable to lateral load such as earthquake. So, it is necessary to analyze the dynamic behavior characteristics according to various design variables of arched stone bridge under seismic loads. To this end, the arched stone bridge can be classified according to arch types, and then the discrete element method is applied for the structural modelling and analysis. In addition, seismic loads according to return periods are generated and the dynamic analysis considering the discontinuity characteristics is carried out. Finally, the dynamic behavior characteristics are evaluated through the structural safety estimation for slip condition.
In order to investigate the runoff characteristics of nonpoint source pollutants in the Lake Doam watershed, water quality and flow rate were monitored for 38-rainfall events from 2009 to 2016. The EMC values of SS, COD, TN and TP were in the range of 33~2,169, 3.5~56.9, 0.09~7.65 and 0.06~2.21 mg L-¹, respectively. As a result of analyzing the effect of rainfall factor on the nonpoint source pollutant load, EMCs of SS, COD and TP showed a statistically significant correlation with rainfall (RA) (p<0.01) and SS showed highly significant correlation with maximum rainfall intensity (MRI, R=0.48). The load ranges of SS, COD, TN and TP were 10.4~11,984.6, 1.1~724.4, 0.6~51.6 and 0.03~22.85 ton event-¹, respectively, showing large variation depending on the characteristics of rainfall events. The effect of rainfall on the load was analyzed. SS, COD and TP showed a positive correlation, but TN did not show any significant correlation. The annual load of SS was the highest with 88,645 tons year-¹ in 2011 when rainfall was the highest with 1,669 mm. The result of impact analysis of nonpoint source pollution reduction project and land-use change on runoff load showed that pollutant load significantly reduced from 2009 to 2014 but SS and TP loads were increased from 2014 to 2016 due to increase in construction area. Therefore, we suggested that nonpoint source pollution abatement plan should be continued to reduce the soil loss and pollutants during rainfall, and countermeasures to reduce nonpoint source pollution due to construction need to be established.
This paper relates to the study of load characteristics applicable to wind turbine generators induced by earthquakes. An artificial design earthquake wave generated through the target spectrum and the envelope function of Richter Magnitude Scale (ML) 7.0 as in ASCE4-98 was created. A simulation of earthquake loads were performed according to the design load cases (DLC) 9.5~9.7 of GL guidelines. Additionally, simulation of seismic loads experienced by Wind Turbines installed in the Gyeongju region were carried out utilizing artificial earthquakes of ML 5.8 simulating the real earthquakes during the Gyeongju Earthquakes of Sept. 2016.
In this study, we investigated the effects of EGR rate and engine load on the emission characteristics in a 4-cylinder common rail direct injection diesel engine fueled with canola oil biodiesel (BD) blended fuel. The biodiesel blend fuel, BD20 (20 vol.% biodiesel and 80 vol.% ULSD blend) was used at an engine speed of 1,500rpm. The experimental results showed that with the increasing of EGR rate, the combustion pressure and rate of heat release (ROHR) of three test fuels were decreased, and the ignition delay was extended, the carbon monoxide (CO) and particulate matter (PM) emissions increased slightly, but the nitrogen oxide (NOx) emission decreased clearly. On the other hand, with the increasing of engine load, the combustion pressure and ROHR were increased, and the CO and PM emissions decreased. However, the NOx emission was increased due to the rise of the combustion temperature.
In this study, the effect of upper die type on the load characteristics of lower die and the wasted material was studied numerically. The different shapes(A-type, B-type, and C-type) of upper die were applied. Also finite element analysis method was applied for the analysis in each stage. The half of X, Y plane was analyzed due to the symmetrical shape in order to reduce the analysis time and be accurate results. The coefficient of friction was set to oil_cold conditions as refer to the system library.
It was revealed that principal stress was the order in A, C, and B. A and B type have the highest value in 4 stage, and C type shows the highest value in 3 stage. In addition, Von mises stress were higher in order A, B, and C. A and B type have the highest in 4 stage, and C type shows to have about the same value in the 2 - 5 stage. The load was generally higher than C type. The load of C type was reduced in YY-direction at each stage without 2, 5, 6 stage.
가스 생산용 해양플랜트 설비의 경우 폭발의 위험에 노출되어 있으며, 폭발사고는 구조물의 안전성에 치명적인 영향을 미칠 수 있다. 따라서, 이러한 폭발사고에 의한 피해를 최소화하기 위해서는, 폭발하중에 의한 구조부재의 동적응답 특성을 명확히 파악할 필요가 있다. 폭발하중의 경우 매우 짧은 시간 동안에 구조물에 가격되었다가 소멸되기 때문에 구조부재의 고유주기 및 폭발하중의 지속시간을 고려한 동적응답 평가가 필수적으로 요구된다. 일반적으로 가스 폭발하중의 경우, 부 압력단계가 전체 하중 이력에서 상당 부분 존재하며, 본 연구에서는 이러한 부 압력단계의 형상에 따라 총 하중 지속시간을 결정하는 하중 모델을 제안하였다. 방화벽은 폭발사고 시 장비 및 인명 피해를 방지하고자 FPSO 탑사이드 모듈 사이에 배치되는 구조부재이므로 폭발하중에 의한 응답이력 특성 분석이 반드시 필요하다. 때문에 무 감쇠 단 자유도 모델에 가스 폭발하중을 적용하여 변위응답 특성을 분석하였으며, 평판으로 구성된 방화벽의 FE 모델을 이용한 하중 지속시간과 구조부재들의 고유주기를 고려한 응답 특성을 분석하였다. LS-DYNA를 이용한 선형/비선형 구조해석 분석결과, 부 압력단계의 지속시간이 구조물의 동적응답에 큰 영향을 주는 것을 보였다.
가스 생산용 해양플랜트 설비에서 발생할 수 있는 폭발사고의 경우, 구조 시스템의 기하학적 특성이나, 바람, 가스 누출율 등과 같은 환경적 조건에 의해 피해 규모의 범위가 상당하다. 따라서 폭발파에 의한 구조 부재의 응답을 분석하기 위해서는 이러한 조건들을 고려한 가스폭발 수치해석 과정이 반드시 필요하다. 본 연구에서는 FPSO 탑사이드의 형상 및 장비 배치와 같은 세부적인 부분까지 고려하여 폭발해석을 수행하였으며, 이를 바탕으로 획득한 하중 이력들의 특성을 분석하였다. 또한 다양한 형태로 나타나는 폭발하중 이력들 중 구조물 손상에 직접적으로 영향을 미칠 수 있는 최대 압력과 지속시간들을 고려하여 유한요소해석 시 하중조건으로 적용한 후, 부재의 응답특성에 관한 분석을 수행하였다. 유한요소해석 모델은 실제 구조물에 적용이 가능하고, 복잡한 형상을 이상화한 단 자유도 및 다 자유도 모델을 사용하였다. 정 압력 및 부 압력단계의 최대 압력이 증가함에 따라 구조 부재의 최대 응답이 증가하였고, 부 압단계에서 하중 지속시간이 증가함에 따라 구조물의 최대 변위가 증가는 경향을 보였다.
이 논문에서는 곡선 프리스트레스트 콘크리트 사장교의 풍하중에 의한 정적 횡방향 휨거동 해석에 비선형 해석 모델 특성들이 미치는 영향을 검토하여 곡선 프리스트레스트 콘크리트 사장교의 풍하중에 의한 정적 휨거동을 정당하게 예측할 수 있는 해석방법을 제시하였다. 곡선 프리스트레스트 콘크리트(PSC) 사장교의 시공단계별 풍하중에 의한 횡방향 휨거동 해석 시 재료의 비선형성은 물론 기하학적 비선형성을 모두 고려하였고 재료의 시간의존적 특성의 영향으로 콘크리트의 크리프, 건조수축, 강도증가와 프리스트레싱(PS) 강재와 케이블의 이완을 고려하였다. 곡선 PSC 사장교의 풍하중에 의한 휨거동을 다양한 비선형 해석 모델 특성들을 조합해서 고려하여 해석을 수행한 결과, 교량 상판의 인장균열 및 이에 따른 처짐의 증가를 정확히 예측하기 위해서는 재료의 비선형 응력-변형률 관계는 물론 콘크리트의 인장균열을 모두 포함한 재료 비선형성과 기하강성도 매트릭스는 물론 대변위에 의한 변형률의 비선형항 및 부재의 위상변화를 모두 포함하는 기하학적 비선형성을 고려한 해석이 반드시 필요함을 확인하였다. 부가적으로, 콘크리트의 인장증강효과 및 뼈대요소의 축력에 의한 기하강성도 매트릭스의 고려여부는 교량의 풍하중에 의한 정적 휨거동을 예측하는 데 영향을 크게 미치지 않는 것으로 나타났다. 또한 풍하중에 의한 곡선 PSC 사장교의 횡방향 휨거동은 상판의 횡방향 변위의 상당한 증가 및 거더 단면의 인장균열로 인해 상판이 폐합되기 직전단계가 폐합된 이후 단계보다 크게 불리함을 확인하였다.
Micro structure observation for low carbon steel base material and heat treatment(annealing), performing a tensile test and impact test, the specimen after the impact test is intended to evaluate the crack propagation characteristics by performing a fractal dimension analysis. The tensile strength of the base materials were observed higher compared to the heat treated materials, impact absorbed energy of heat treated materials was a higher than base materials. Impact Test and fractal dimension of the side of the test specimen was shown significantly more test temperature increases, heat treated material was higher than the base material
This study shows an application method of Micro Grid integrating Solar Energy Seasonal Storage (SESS) based on the analysis of time-variant load characteristics of electric railway. Micro Grid includes various renewable energy generation plants as like wind farm, photovoltaic, small hydro, fuel cell, etc. and some energy storage systems to meet the balance between generation production and demand. The essential concept of this paper is the connection and integration between electric railway and Micro Grid including SESS which is able to control power system frequency. This new concept for power system stabilization would be tested in an independent Micro Grid site and some detail application methods would be evaluated for the commercialization.
최근 국내에서는 원자력발전소의 모듈화 공법에 적용하기 위하여 SC(steel plate concrete) 구조를 개발하는 연구를 진행하고 있다. 이 연구에서는 전단보강이 없는 비보강 SC 전단벽의 횡방향 내진성능 및 강성특성에 대하여 분석하기 위하여 전단벽 모형시편을 제작하고, 이를 대상으로 정적가력실험을 수행하였다. 실험 결과를 이용하여, 이 논문에서는 비보강 SC 구조의 횡력에 대한 파괴모드의 유형을 분석하고, 단면강도와 부재의 강성 특성을 검토하였다. 그리고 SC 구조용 설계기준에서 제시하는 단면의 강도 계산식과실험결과를 비교하였다. 연구결과, 비보강 SC 전단벽의 파괴 형태의 하나는 콘크리트와 강판의 부착 상실로 인한 휨전단파괴라는 사실을발견하였다. SC 구조 전단벽의 벽체 길이방향 거동은 파괴 시까지 벽체 외측의 강판이 내부 콘크리트를 구속하는 효과를 기대할 수 있으므로 연성능력이 향상되는 것이 확인되었다
The effect of load and sliding speed on abrasive wear characteristics of glass fiber/polyurethane (GF/PUR) composites were investigated at ambient temperature by pin-on-disc friction test. The friction coefficient, cumulative wear volume and surface roughness of these materials against SiC abrasive paper were determined experimentally. Experimental results showed that the surface roughness of the GF/PUR composites was increased as applied load was higher in wear test. The cumulative wear volume tended to increase nonlinearly with increase of sliding distance and depended on applied load and sliding speed for these composites. It could be verified by scanning electric microscopy (SEM) photograph of surface tested that major failure mechanisms were lapping layers, ploughing, delamination, deformation of resin and cracking.