검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 15

        1.
        2023.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A universal joint is a device that transmits the power of a combat vehicle engine to a cooling fan. The power of the engine is transmitted to the universal joint as it is without buffering, and play occurs at the joint between the drive shaft connected to the engine and the driven shaft connected to the cooling fan according to the usage time. Accordingly, the universal joint is periodically replaced, and the criterion for this is the degree of torsion of the universal joint. However, if the universal joint is not properly maintained during the replacement cycle, damage to the universal joint as well as damage to the surrounding power supply may occur. Accordingly, a backlash measuring device was developed to determine the limit of durability of the universal joint, and the limit of durability was derived through regression analysis of the backlash value according to the use time obtained from the accelerated life test.
        4,000원
        3.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        작물 수분스트레스 지수(CWSI; Crop Water Stress Index)를 통해 관개 시기를 판단할 경우, 정확한 잎의 온도 및 대기 환경을 측정하는 것이 중요하다. 그리하여 본 연구에서는 실시간으로 작물의 생체정보(엽온) 및 대기 환경(대기온·습도, 일사량)을 측정하고 자동으로 CWSI 값이 산정되는 휴대용 수분스트레스 계측기기를 개발하였다. 또한 휴대용 수분스트레스 계측기기와 고정식 온도 측정 방법과의 비교 분석을 통해 휴대용 수분스트레스 계측기기의 성능을 평가하고자 하였다. 본 계측기기는 CWSI 산정을 위한 생체신호 및 기상 데이터를 측정하는 센싱부, 측정된 데이터를 저장하고 CWSI를 산정하는 데이터 수집부, 장치의 기능을 조작하고 측정값을 표시하는 시스템 제어부로 구성하였다. T-test를 실시하여 두 계측 방법에서 측정된 엽온, 일사량, CWSI 평균값의 유의 관계를 분석한 결과, 유의확률은 0.089, 0.318 그리고 0.028로 각각 나타났다. 엽온과 일사량은 유의수준 0.05보다 크므로 유의미한 차이가 나타나지 않았지만 CWSI는 유의확률이 유의수준보다 작으므로 두 측정 방법에 따라 유의미한 차이가 나타났다.
        4,000원
        4.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        엔진의 출력을 측정하기 위한 방법은 실린더의 연소압력을 측정하여 지시마력을 구하는 방법과 축토크를 측정하여 축마력을 구하는 방법이 있다. 축토크로 실린더의 상태를 확인하기에는 한계가 있으며, 엔진의 성능 측정과 실린더의 연소 해석을 위해서는 실린더 의 연소 상태를 확인할 수 있는 연소압력을 측정하는 방법이 가장 정확하다. 측정에 있어 연소압력은 크랭크샤프트 회전 각도에 따른 실린더 압력이 도시되어야하기 때문에 정확한 실린더 앵글각도를 정확히 인지시키는 작업이 가장 중요하다. 본 연구에서는 실제 운항선의 발전기 엔진을 대상으로 실린더 압력을 측정하기 위하여 크랭크 앵글 센서로 엔코더를 사용하였고 엔코더에서 인지하는 TDC(TDCencoder)와 압축압력에 의한 TDC(TDCcomp) 간의 실측을 통하여 차이가 발생하는 원인에 대하여 고찰하였다. 또한 0 %, 25 %, 50 %와 60 % 부하에서 측 정된 실린더의 TDCcomp와 TDCencoder 간의 차이를 통하여 크랭크샤프트의 제작에 의한 영향, 부하증가에 따른 엔진과 발전기 사이의 커플링 영향에 대한 결과를 고찰하였으며, 발전기의 부하가 증가할수록 최대 3°CA까지 TDC의 오차가 발생함을 확인하였다.
        4,000원
        6.
        2018.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        작물생육의 품질 및 생산량에 중요한 영향을 미치는 온실 내 환경관리에 대한 연구는 활발히 진행되고 있다. 주로 온실 내 환경분포를 측정하는 방법으로는 한 두 지점에 대해서만 측정하여 온실 전체를 관리하는 시스템 으로 이루어졌으며 기존 환경데이터 측정방식은 각각의 데이터 로거 및 센서간의 배선들로 인하여 복잡한 시스템으로 구성되었다. 본 연구에서는 온실 내 설치 된 각 환경센서들로부터 지점별 데이터를 획득하고 획득된 데이터는 모니터링 프로그 램을 통하여 공기유동흐름을 측정하는 장치를 개발하였다. CAN 네트워크 통신을 통하여 환경센서들의 배선 토폴로 지를 간소화 했으며 프로토콜의 견고함으로 온실 내 모니 터링을 안정적으로 데이터를 수집할 수 있도록 구현되었다. 온실 내 공간의 환경요인 분포(온·습도 및 풍속 등) 들을 12개 지점에 배치하고 온·습도 및 풍속의 환경 데이 터는 상세히 파악할 수 있도록 X, Y, Z 축으로 다수의 측 정점(총 36점)을 선정하였다. 데이터 손실 및 다양한 온실 조건을 고려하여 비트레이트를 저속 125kbit/s로 구현하여 온실 내 100m 구역내에서 센서를 추가적으로 연장(총 90 개)할 수 있도록 구축되었다. 온도, 습도, 일사량, 풍향, 풍 속, 대기압 및 강우량 등 측정된 데이터는 LabVIEW에 연 동되어 실시간으로 센서 정보 출력이 가능하도록 구현되었다. 온실 내 환경 분포는 사용자의 편의에 따라 환경분포를 수평(XZ), 수직(YZ)축으로 가시화 할 수 있으며, 보간의 범위를 원하는 값으로 설정하여 보간 할 수 있도록 구현되었다. 추후에 온실 내의 공간에 따라 온도, 습도, 풍속, CO2 등의 환경 측정 실험을 통하여 CFD 모델링과의 검증 및 비교에 활용할 수 있을 것으로 판단된다.
        4,000원
        7.
        2017.04 구독 인증기관 무료, 개인회원 유료
        This study is a development of measuring instrument capable of measuring the temperature measurement at a temperature of between 0 ℃ and 1600 ℃ at a high temperature of the high temperature. This development technique develops a measuring device capable of measuring two different temperature measurements by combining two different temperature measurements ranging from one measurement module to the hot temperature to the high temperature. Also, it develops in a vacuum or high pressure state.
        3,000원
        8.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        We developed the memory storage type instrumentation device for measuring trajectory of small flying object. The instrumentation device is small enough to install into the flying object and has a 6-axis MEMS sensor and 3 AD channels for measuring flying data of object. In this paper, we specially focused on the measuring of flying trajectory of the sabot using developed device. The sabot which supports missile during carriage breaks away from missile by mechanical and aerodynamic force when missile gets out of canister. The flying trajectory of sabot should be designed not to collide with any equipments around the launcher. In order to find out the flying trajectory of sabot, the developed instrumentation device was adopted in experiment. We have proved effectiveness of the developed instrumentation device by comparing acquired results using the hi-speed camera.
        4,000원
        9.
        2015.03 구독 인증기관 무료, 개인회원 유료
        This study is reduction to measuring error rate which checked or evaluated of overspeed euipment in the local roadway, national roadway and highway for overspeed driving vehicle. Especially, reliability of overspeed equipment is very important according to speed measurement devices between roof sensing method and radar, etc. So, this study is to measuring method and measuring devices for high reliability.
        4,000원
        10.
        2011.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        감성과학에서 인간의 감성을 손쉽게 측정할 수 있는 기술이나 기법 등은 매우 중요한 분야이다. 최근 마음의 변화는 몸의 변화를 수반한다(정신신경증면역내분비학, psychoneuroimmunoendocrinology)는 전제하에 인간 감성을 체액을 통해서 측정하는 시도가 이루어지고 있다. 몸의 변화 중에 최근까지 가장 많이 연구된 것은 스트레스에 관한 것으로 이를 측정하는 지표로는 코티졸(cortisol)이라는 물질이 널리 알려져 오고 있다. 코티졸을 측정하는 기존의 방법을 열거하면 High Performance Liquid Chromatography (HPLC), fluorometric assay, reverse phase chromatography 등이 대표적인데 모두 시간이 많이 걸리고 가격이 비싸며 휴대용이 아니기에 POCT (point of care testing)에 적합하지 않다. 이에 본 연구진은 소형 초고주파 공진 소자를 만들어 타액 속의 코티졸을 측정할 수 있는 항체를 고정하고 이것이 코티졸과 결합할 때 나오는 공진신호를 읽음으로써 환자의 타액 속 코티졸을 쉽고 빠르게 측정할 수 있는 기법을 소개한다. 본 연구를 위해 제안된 공진소자는 밀리미터 크기의 소자로서 제작이 용이하며 간단한 형태이다. 최종적으로 소자표면상에 결합되는 코티졸 농도변화(100, 10, 1, 0.1 ng/ml)에 따라 거의 선형적인 주파수응답(11, 10, 9, 7 MHz) 특성을 보인다. 100 pg/ml에 해당하는 적은 코티졸의 양까지 거의 실시간에 가까운 빠른 시간 안에서 쉽게 검출이 가능하며, 뿐만 아니라 표지(labeling)가 필요 없는 장점을 가지고 있다. 이러한 농도에 따른 주파수 변화를 기반으로 하는 코티졸 감성지표센서는 무선단말시스템에 적용될 수 있는 가능성과 응용성을 가지고 있다.
        4,000원
        11.
        2006.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A valve open/close degree measuring device is used for an indicator of a valve actuator. This device indicates an opening and closing of a valve or throttle in a hydraulic actuator. In ship, equipments requires safe and robust because of a rough environment and a specific condition during a voyage. Thus, the open/close degree measuring device must be developed which can be used at an outdoor environment. This study developed the open/close degree measuring device using a volumetric measuring method(25㎖/100㎖). The housing of the open/close degree measuring device was made by a stainless steel with surface painting after an anodizing coating.
        4,000원
        12.
        2005.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        폭주부족을 진단하는데 중요한 요소인 폭주끈점은 표준화된 측정방볍이 제시되지 않고 여러 방법이 사용되고 있는 실정이므로, 시표의 접근속도를 1cm 단계로 조정 할 수 있는 전동식 폭주근접 측정장치플 개발하여 각 측정방법에 따른 폭주근점을 비교 분석하였다. 안질환파 사시, 억제, 조절장애가 없고 원/근 나안 또는 교정시력이 l.0 이상인 산과 창원소재 고등학생과 대학생 135 명을 대상으로 원/근 사위도 벚 폭주끈점을 정하여 정상군과 폭주부족 예상군으로 나누었다. 정상군에서 폭주근점 파괴값은 6.8 :t 2.7 cm, 회복값은 10.9 :t 3.6 cm, 폭주부족 예상 군에서 파괴값은 13.4 :t 4.8 cm, 회복값은 18.8 :t 5.9 cm 로, 폭주부족 예상군이 정상군 보다 파괴값은 6.6cm, 회복값은 7.9cm 더 별었다. 정상군의 폭주큰점은 조절타게트 5.2 :t 2.1 cm 펜라이뜨 5.7 土2.8cm 펜라이트 + 적녹안경 6 .4 :t 3.0 cm 순으로 크게 측정 되었다. 또한 시표의 이동속도가 빨라지면 회복값이 증가하는 경향을 보였으며, AC/A 비가 낮을수록 폭주근점이 별어지는 경향을 보였다. 동일한 대상에서 측정방볍별 10 회 반복측정결과 정상꾼과 폭주부족 예상군 모두 측정횟수가 증가할수록 폭주근점이 멸어지는 경향을 보였으며, 정상군에서 1-5회와 6-10 회 측정값의 평균 비교, 1-3회와 8-10 회 측정값의 평균 비교에서 모든 측정방 법의 파괴값만 유의한 차이를 보였고 (p 二0.000) , 폭주부족 예상군은 펜라이트+ 적녹 안경 의 파괴 값만 유의 하였다 (p = 0.(01). 이상의 결과로부터 본 연구에서 개받한 전동식 폭주근점 측정장치를 이용하여 타 게트의 종류 및 이닫속도가 다른 조건에서 폭주근점을 측정하였을 때 비슷한 결과플 얻었으며, 이 장치는 임상에서 유용하게 활용될 수 있을 것으로 생각된다
        4,200원
        13.
        2018.09 KCI 등재 서비스 종료(열람 제한)
        Information about the density of fish eggs is important to understand the vertical distribution of eggs and survival in early stage, in particular change in egg density is one of major issue in fisheries. This paper describes a practical application of an experimental system for measurement of the fish egg density under laboratory conditions. The device can control the temperature range in each water column, and make different densities at each layer. The density of olive flounder (Paralichthys olivaceus) eggs have ranged from 1,018.49 to 1,020.93 kg/m3 and were aggregated around the density of 1,020 kg/m3. The results show that the device is applicable for measuring the fish egg density under laboratory conditions.
        14.
        2017.06 서비스 종료(열람 제한)
        Urban green spaces can mitigate negative impacts of urban heat island effect by creating cooling buffer zones. These cooling areas improve micro-climatic conditions and human health. Green space is important to reducing urban air temperature maxima and variation. Thus, there is an expectation that small green spaces (SGs) provide high cooling effects and thus make air temperatures drop. Meanwhile, such an effect in urban areas has been under-explored and needs more detailed spatial and temporal data. The purpose of the study was to develop a measurement method to detect temperature of various SGs with TVC and find the effect of TVC on accuracy of measured air temperature data in comparison with other non ventilation devices. We updated the cad file of the study site through comparing it with Google Map and conducting field surveys on the site. Transect survey was required to build a measurement route. We toured the study site by walk repeatedly to get the optimistic route which would have enough data points. One of considered routes which were inside of the forest and could make us get significantly influencing data was not founded for no trails so excluded in our study. After the field survey, we observed the study routes through a digital camcorder (Gopro) and recorded them on the cad file of the site because these data points should include air temperature and time data in their attribute table. As for transect survey, a researcher walked through the defined routes and collected air temperature data with two TVCs every second and two Testo loggers covered by aluminum foil every minute at the height of 1.5m from the ground. Stationary survey was conducted with two TVCs in every second data collection and two Testo loggers covered by aluminum foil in every minute data collection on the resting area at the entrance of the site. One of TVCs and one of Testo loggers were set at the height of 0.5m while the others of TVCs and Testo loggers were at the height of 1.5m. On the stationary point, other microclimate variables such as wind velocity, wind direction and solar irradiance were also measured and recorded every minute. We repeated the measurement for one day or two days a month (November, 2016 ~ May, 2017) and four times a day. The measuring days were selected when they were clean and calm. As a result, air temperature from TVCs was entirely lower than that from Testo loggers on the stationary survey. This trend was shown during the day rather than after sunset. The difference of air temperature from between TVCs and Testo loggers ranged from 2 ℃ after sunset to 5 ℃ at 16h. At the height of 0.5m, a Testo logger's data showed much higher than a TVC's data. These results show that Testo loggers tend to be easily influenced by the change of solar radiation. Moreover, there was the ventilation effect at the stationary. So no ventilation could be the main reason why Testo loggers' data were high. However, TVCs' lower temperature explains how effectively these devices block the solar radiation and ventilate air inside the cylinder.
        15.
        2015.02 서비스 종료(열람 제한)
        각종 가연물의 화재 시 연기밀도의 정확한 측정은 화재안전설계를 위해 매우 기초적이며 중요한 정보를 제공한다. 특히 고난이도의 피난대책이 요구되는 초고층 및 아파트 건물화재, 선박화재 그리고 다양한 유형의 화재위험지구에서는 개선된 제연설비의 설계를 위하여, 정확한 연기발생량 및 광학밀도에 대한 평가가 선행되어야 한다. 그러나 연기밀도의 측정에 주로 사용되고 있는 광소멸법(Light Extinction Method)의 적용은 고가의 광학장비가 요구되고 있으며, 주로 기초적이고 제한적인 연기밀도 측정에만 적용되는 실정이다. 이러한 배경 하에 본 연구에서는 광소멸법에 주로 사용되는 He-Ne 레이저, 광검출기(Photo detector) 및 다양한 광학 구성품 대신에 비용 측면에서 약 1/400(약 1만원 이내)에 해당되는 레이저모듈과 포토셀(Photocell)로 구성된 저가형 연기농도 측정 장치를 제안하고자 한다. 다양한 연기농도의 생성이 가능한 연기발생장치를 통해 위의 2가지 측정법의 결과가 비교·검토되었으며, 실제 폴리에틸렌 화염을 대상으로 저가형 연기 농도 측정장치의 성능이 평가되었다. 주요 결과로서, 새로운 저가형 광학 연기밀도 측정장치는 기존 고가의 장치에 비해 출력 전압신호가 정성적 및 정량적으로 매우 유사한 경향을 보이고 있다. 낮은 광학연기밀도의 범위에서 저가 장치는 약 ±15% 내에서 고가 장치의 측정값을 예측하고 있다. 그러나 수광부 센서의 최소 감지성능의 제약으로 인하여 연기밀도가 매우 높은 조건에서는 최대 +60%의 과대예측 결과를 보이고 있다. 이러한 원인은 광원과 수광부 센서의 성능검토를 통해 충분히 규명될 것으로 판단된다.