검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 57

        1.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this article, nitrogen (N) doped porous carbon nanofibers (N-PCNF) were prepared by carbonization of polymer-silica nanocomposite precursor, and its application for heavy metal ion removal was demonstrated. Carbon–silica composite nanofibers were obtained by carbonization of electrospun polyacrylonitrile (PAN)-silica nanofiber composites. Subsequent selective etching of silica porogen produced porous carbon nanofibers (PCNF). It was revealed by surface characterization with X-ray photoelectron spectroscopy (XPS) that the surface of the PCNF was nitrogen-doped because N atom from cyanide group in PAN chains remained in the hexagonal carbon structure. The use of the obtained N-PCNF for heavy metal ion ( Hg2+) removal was demonstrated using a simple adsorption test apparatus and 5, 10, 15, 20-tetraphenylporphine tetrasulfonic acid (TPPS) as an indicator. The N-PCNF showed a removal efficiency of 96 and 99% in 10 and 120 min, respectively, indicating a maximum heavy metal ion adsorption capacity at pH 7.0. In addition, heavy metal ion adsorption behavior was also analyzed using common adsorption isotherms. This article provides important information for future research activities regarding control over hazardous substances.
        4,000원
        2.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The removal of organic carbon and nutrients (i.e. N and P) from wastewater is essential for the protection of the water environment. Especially, nitrogen compounds cause eutrophication in the water environment, resulting in bad water quality. Conventional nitrogen removal systems require high aeration costs and additional organic carbon. Microbial electrochemical system (MES) is a sustainable environmental system that treats wastewater and produces energy or valuable chemicals by using microbial electrochemical reaction. Innovative and cost-effective nitrogen removal is feasible by using MESs and increasing attention has been given to the MES development. In this review, recent trends of MESs for nitrogen removal and their mechanism were conclusively reviewed and future research outlooks were also introduced.
        4,300원
        3.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        암모니아성 질소(NH4-N)는 산업 폐수, 농업 및 축산 폐수에 포함되어 있으며 인과 함께 수질의 부영양화를 일으 키는 물질로 잘 알려져 있다. 또한 망간(Mn)과 비소(As)는 광산 처리수 등에 포함되어 있으며, 수질 오염의 원인 물질로 알려져 있다. 천연 제올라이트는 수중에서 암모니아성 질소를 제거하는데 사용되고 있지만 낮은 흡착능력을 가진다. 이러한 천연 제올라이트의 낮은 흡착능력을 개선하기 위해 Na+, Ca2+, K+, Mg2+로 이온 치환을 진행하였다. 암모니아성 질소(NH4-N)의 흡착량과 제거율은 Na+로 이온 치환된 제올라이트에서 0.66 mg/g과 89.8%로 가장 높은 값을 보였다. 이온 치환된 제올라이트 를 이용하여 Mn과 As의 흡착실험을 진행하였다. Mg2+로 이온 치환된 제올라이트에서 Mn과 As의 높은 흡착량과 제거율을 보였다.
        4,000원
        4.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        대기오염물질 중 미세먼지는 심각한 사회적 환경문제로 인식되고 있다. 미세먼지의 원인 물질 중 하나인 질소산화물(NOx)은 석탄화력발전소의 연소공정에서 주로 발생하므로 효율적인 NOx 제거가 필요한 실정이다. 본 연구에서는 선택적 촉매 환원법(Selective Catalytic Reduction, SCR)을 이용한 NOx 제거에서 TiO2 광촉매의 NO 제거효율을 연구하였다. NO 제거효율을 평가하기 위해 발열제가 내장된 Al2O3 기판 표면에 TiO2 촉매와 인산염의 접착 바인더를 혼합하여 도포한 후 제조된 기판을 열처리하면서 실험을 수행하였다. 온도에 따른 촉매의 NO 제거효율을 평가하였고, 촉매의 물리화학적 특성을 위하여 XRD, SEM, TG-DTA, BET 분석을 수행하였다. NOx 제거 효율은 시간에 따른 온도변화(250℃∼500℃) 로 20분에서 제거효율은 58.7%∼65.9%이며, 30분에서 63.7%∼66.0%로 나타났다. 질소산화물 제거용 SCR로 사용되는 TiO2는 300℃가 제거효율이 가장 효율적인 것으로 판단된다.
        4,000원
        5.
        2018.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objectives of this study were to evaluate the removal characteristics of total nitrogen, the influence factor of denitrification and the optimum operating condition in the pigment wastewater treatment using PAC-A/O process. The operating conditions of PAC-A/O process were mean BOD volumetric loading 0.86 kgBOD/m3/day, mean F/M ratio 0.072∼0.13 kgBOD/kgMLVSS/day and mean C/N ratio 3.47, respectively. The conditions of anoxic process in the field plant test were mean pH 8.3∼8.7 and mean temperature 34.1~44.0℃. The ORP bending point knee was eventually appeared in the ORP -107 mV and NO3 --N removal efficiency was increased according to the ORP decrease. In the ORP -107 mV below condition, the removal efficiency of T-N and NO3 --N was 92.3∼95.0% and 98.5∼99.7%. Denitrification rate was calculated to be 1.581∼1.791 mg NO3 --N/gMLSS/hr. The experimental results showed that the ORP control in the PAC-A/O process could be an effective method for treatment of pigment wastewater.
        4,000원
        6.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 강산 분위기에서 아연의 산화 환원 반응을 통한 폐수 중 질산성 질소 제거에 관한 연구이다. 폐수에 황산(H2SO4)을 첨가하여 강산 분위기를 조성한 다음, 아연과 설파믹산을 넣어주게 되면 금속 아연이 산화되고, 이온화된 질산성 질소가 환원 처리되어 제거되는 연구이다. 산화 반응은 강산 분 위기일수록 반응이 잘 일어나기 때문에 pH 2.0~4.0 범위 중 pH 2.0에서 제거효율이 높았다. 설파믹산을 첨가함으로써 질산 이온을 최종 질소가스로 환원시켜 제거하는 것이 설파믹산이 존재하지 않을 때보다 H+ 이온 소모량이 적기 때문에 설파믹산을 투입하는 것이 유리하였다. 같은 아연 양에 따라 설파믹산을 넣지 않은 것은 질산성 질소가 46.0% 제거되는 반면, 설파믹산을 넣게 되면 질산성 질소가 93.0% 제거 된다. 본 실험에서 아연은 입자가 분말 형태로 제조되어 반응성이 다른 일반 아연 금속보다 크기 때문에 반응 후 1분 만에 제거 효율이 약 80.0% 로 매우 높게 나타났다.
        4,000원
        7.
        2017.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Nitrogen-doped carbon nanosheets with a developed porous structure were prepared from polyurethane foams by hydrothermal carbonization following ZnCl2 chemical activation. Scanning electron microscopy, thermogravimetric analysis, Fourier transform infrared spectroscopy, solid state 13C nuclear magnetic resonance (NMR) spectra and X-ray photoelectron spectroscopy were used to characterize the nitrogen-doped carbon nanosheet structure and composition. The removal of Cr(VI) by the N-doped carbon nanosheets was investigated. The results showed that the maximum removal capacity for chromium of 188 mg/g was found at pH=2.0 with PHC-Z-3. pH had an important effect on Cr(VI) removal and the optimal pH was 2.0. Moreover, amino groups and carboxyl groups in the nitrogen-doped carbon nanosheet played important roles in Cr(VI) removal, and promoted the reduction of Cr(VI) to Cr(III).
        4,000원
        9.
        2016.05 구독 인증기관·개인회원 무료
        본 연구는 잉여슬러지와 차아염소산나트륨을 혼합하여 제조한 차아염소산나트륨 처리 슬러지를 침지형 분리막이 설치된 생물반응조에 주입하여 수처리 미생물에 기질을 공급하고 수처리에 적합한 pH와 알칼리도를 유지함으로써 응집제 주입 없이 방류수의 총질소 농도 20 mg/L, 총인 농도 0.2 mg/L 이하로 처리할 수 있는 MBR 하수처리공정을 개발하였다. 개발된 공정은 별도의 응집제 주입 없이 질소와 인의 법적 방류수 수질기준 을 만족하였고, 향후 하수처리장 약품비용 절감에도 기여할 것으로 기대된다.
        10.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The amount of waste water generated from the domestic sources is consistently increasing in proportion to economic growth, and the conventional activated sludge process is widely being used for general waste water treatment. But the ministry of environment becomes stringthent treatment standards of N and P (less than 20mg/L of N, 2mg/L of P) to prevent the eutrophication of lake water, and therefore highly advanced treatment technology is required not only in the existing treatment plants where the activated sludge process is being used, but also in newly constructed treatment plants for the treatment of N and P. This study is aimed at highly operating the engineering technology method was developed by domestic to eliminate N and P at the same time. Experiments were conducted in the treatment plant located in Yong In city. The bioreactor was started from the principal equipment for the elimination of N and P and the elimination of organic compounds. It consists of an internal recycle piping from the end of the aerobic tank to the anoxic tank and external recycle piping from the final settling basin to the denitrification tank. By experiment of 4 types separate inflow of waste water to the denitrification tank and the anaerobic tank, and changes in staying time at the anoxic tank and the aerobic tank, the elimination of organic compounds in each type and the relationship in the efficiency between the elimination of N and P were researched.
        4,000원
        11.
        2014.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Immobilization of anaerobic ammonium oxidizing bacteria has been studied to enhance the biomass retention of the slowly growing bacteria and the process stability. The purpose of this study was to compare the nitrogen removal efficiency of granular and immobilized anammox bacteria with poly vinyl alcohol and alginate. The specific anammox activity of the granular, homoginized and immobilized anammox bacteria were 0.016±0.0002 gN/gVSS/d, 0.011±0.001 gN/gVSS/d and 0.007±0.0005 gN/gVSS/d, respectively. Although the activity decreased to 43.7 % of the original one due to low pH and O2 exposure during the homogination and the immobilization, it was rapidly recovered within 7 days in the following continuous culture. When synthetic T-N concentrations of 100, 200, 400, 800 mg/L were fed, the immobilized anammox bacteria showed higher nitrogen removal efficiencies at all operational conditions than those of granular anammox bacteria. When the sludge retention time was shorten below 30.7 days and the reject water was fed, the nitrite removal efficiency of the granular anammox bacteria dropped to 8 % of the initial value, while that of the immobilized anammox bacteria was maintained over 95 % of the initial one. The immobilization with poly vinyl alcohol and alginate would be a feasible method to improve the performance and stability of the anammox process.
        4,300원
        12.
        2011.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Step feed process was analyzed stoichiometrically for the optimal operation conditions in this study. In case of optimal operation conditions, minimum R (sludge recycling) value, r (internal recycling ratio) value, and n (influent allocation ratio) value for the step feed process to acquire the maximum TN removal efficiency were identified by theoretical analysis. Maximum TN removal efficiency, based on stoichiometric reaction, can be obtained by controlling n value for the step feed process.
        3,000원
        13.
        2010.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study was to evaluate the possibility of simultaneous removal of ammonium, nitrate and phosphorus in water using the zeocarbon. In this study, the surface of zeocarbon was modified by acid because of difficulty in application of water treatment. After surface modification, the strength was enhanced about 62% higher than that of original one. The removal efficiency of ammonium and nitrate using the modified zeocarbon was about 47% and 32%, respectively and were higher than that of zeocarbon. In batch type experiment on the simultaneous removal of ammonium, nitrate and phosphorus, the presence of phosphorus did not have influence on nitrogen removal efficiency. Concomitantly, removal efficiency of phosphorus was obtained was about 35%. This indicates that the surface modified zeocarbon can be applied for simultaneous removal of nitrogen and phosphorus. Consequently, our results could be used as basic data to design of one-stage nitrogen/phosphorus simultaneous removal system.
        4,000원
        14.
        2010.02 구독 인증기관 무료, 개인회원 유료
        Constructed wetlands have been increasingly used as a low-energy 'green' technique since the mid-1990s, in the treatment of wastewater, driven by rising cost of fossil fuels and increasing concern about climate change. They are man-made systems or engineered wetland that are designed, built, and operated to emulate function of natural wetlands for human desires and needs. Among various applications of these wetlands, one area that is of significant importance is the removal of nitrogenous pollutants, to protect water environment and enable effective reclamation and reuse of wastewater. This report provides a current state of constructed wetland technology, focusing on CANON(completely autotrophic nitrogen removal over nitrite) process that existing types of wetlands, the mechanisms and kinetics of nitrogen removal, wetland design to system performance.
        5,400원
        15.
        2008.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        One of the popular domestic sewage treatment process (called step feed oxic-anoxic-oxic process) for nitrogen removal was analyzed in this study by theoretical analysis based on the nitrification and denitrification reaction. Total nitrogen removal efficiency was suggested by considering influent qualities(i.e., ammonia, nitrite, nitrate, alkalinity, and COD). Total nitrogen removal efficiency depends on r (influent allocation ratio). In the case that all influent components are enough, the total nitrogen removal follows equation 100-b/(1+b), when r is 1/(1+b). Finally, it can be concluded that step feed oxic-anoxic-oxic process could be effective for nitrogen removal.
        4,000원
        16.
        2007.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The oxygen and nitrogen enriched activated carbons were obtained from modification of commercial activated carbon by using nitric acid, sodium hydroxide and urea. Zeta-potentials of modified activated carbons were investigated in relation to copper ion adsorption. The structural properties of modified activated carbons were not so much changed, but the zeta-potentials and isoelectric points were considerably changed. The zeta-potential of nitric acid modified activated carbon was the most negative than other activated carbons in the entire pH region, and the pHIEP was shifted from pH 4.8 to 2.6, resulted in the largest copper ion adsorption capacities compare with other activated carbons in the range of pH 3~6.5. In case of urea modified activated carbon, copper ion adsorption was larger than that of the as-received activated carbon from pH 2 to pH 6.5 even though the pHIEP was shifted to pH 6.0, it was due to the coordination process operated between nitrogen functional groups and copper ion. The adsorption capacity of copper ion was much influenced by zeta-potential and pHIEP of carbon adsorbent.
        4,000원
        17.
        2007.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Based on the experiment results of laboratory scale modified anoxic-oxic process for leachate treatment, biological nitrogen removal program was verified in terms of SS, COD, and TN concentration. These measured water qualities concentration could be predicted by biological nitrogen removal program with R2 of 0.994, 0.987, 0.990, respectively. No error was occurred between water qualities concentration and quite wide range of water qualities concentration (i.e., 50-4200 mg/L) during the modelling. Each unit and final effluent of simulated concentration was kept good relationship with that of measured concentration therefore this biological nitrogen removal program for sewage or wastewater treatment plants has good reliance.
        4,000원
        18.
        2006.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Theoretical total nitrogen removal efficiency and reactor volume ratio in oxic-anoxic-oxic system can be found by influent water quality in this study. The influent water quality items for calculation were ammonia, nitrite, nitrate, alkalinity, and COD which can affect nitrification and denitrification reaction. Total nitrogen removal efficiency depends on influent allocation ratio. The total nitrogen removal follows the equation of 1/(1+b). Optimal reactor volume ratio for maximum TN removal efficiency was expressed by those influent water quality and nitrification/denitrification rate constants. It was possible to expect optimal reactor volume ratio by the calculation with the standard deviation of ±14.2.
        4,000원
        19.
        2005.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        창포를 이용하여 질소와 인의 농도별, 식물의 생장단계별, 오염수의 체류시간별로 질소와 인의 제거효과를 분석하였던 바, 그 결과를 요약하면 다음과 같다. 체류 1시간 후에 수중의 질소와 인의 함량을 현저히 감소시켰으나, 2~4시간 후에는 감소율이 극히 낮았다. 이러한 현상은 식물의 생장초기, 생장기, 생장최성기에서 동일하였다. 수중에 질소와 인의 함량이 많을수록 제거율이 높았고, 인보다는 질소의 제거효과가 크게 나타났다. 생장최성기에 가장 많은 질소와 인을 제거하였고 다음으로 생장기, 생장초기의 순이었으나, 생장단계간의 차이는 극히 작았다. 동일 포트에 4일 동안 체류시킨 것보다 2일 체류 후에 다른 포트로 시험수를 옮긴 것이 질소와 인의 제거율이 약간 높았다.
        4,000원
        20.
        2005.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Step-feed process for biological nitrogen removal were analyzed numerically for the each unit and final total nitrogen(TN) effluent by water quality management(WQM) model and the results were compared data from these wastewater treatment plants. No bugs and logic error were occurred during simulation work. All of the simulation results tried to two times were obtained and both results were almost same as this model has become good reappearance. It was concluded that most of nitrogen removal occurred in the first oxic tank. Thus the controlling of the first anoxic tank may be more important in term of nitrogen removal. Also each unit of simulation result was kept good relationship with that of measured data. Accordingly this WQM model has good reliance. Finally, WQM model can predict final TN effluent within ±6.0mg/l.
        4,000원
        1 2 3