This study investigated the seismic performance of reinforced concrete (RC) wall-slab frames with masonry infills. Four RC wall-slab frames with or without masonry infill were tested under cyclic loading. The RC frames were composed of in-plane and out-of-plane walls and top and bottom slabs. For masonry infill walls, cement bricks were stacked applying mortar paste only at the bed joints, and, at the top, a gap of 50 mm was intentionally left between the masonry wall and top RC slab. Both sides of the masonry walls were finished by applying ordinary or fiber-reinforced mortars. The tests showed that despite the gap on top of the masonry walls, the strength and stiffness of the infilled frames were significantly increased and were different depending on the direction of loading and the finishing mortars. During repeated loading, the masonry walls underwent horizontal and diagonal cracking and corner crushing/spalling, showing a rocking mode inside the RC wall-slab frame. Interestingly, this rocking mode delayed loss of strength, and as a result, the ductility of the infilled frames increased to the same level as the bare frame. The interaction of masonry infill and adjacent RC walls, depending on the direction of loading, was further investigated based on test observations.
본 논문에서는 전이보 시스템이 지닌 층고 및 공사물량 증가의 단점을 보완할 수 있는 경계보-벽체 시스템의 압축성능을 평가하였 다. 1/2 축소실험체에 대한 압축실험을 수행하고 그 결과를 3차원 비선형 유한요소해석 결과와 비교 및 분석하였다. 실험체 변수로 상 하부벽체의 수평길이 상대비, 하부벽체의 두께, 하부벽체 전단보강근의 상세를 고려하였다. 실험의 최대하중은 하부벽체의 공칭축강 도와 유사하게 나타났으며, 이로부터 상부벽체로부터의 수직 하중이 하부벽체로 원활하게 전달되며, 편심으로 인한 모멘트 중 상당 량을 경계보가 가져감을 알 수 있다. 상하부벽체 수평길이의 상대비가 40%일 경우 50%일 때보다 단면의 기여도가 증가하였으며, 하 부벽체에 면외방향 편심이 존재할 경우 단면의 기여도가 감소하였다. 하부벽체의 전단보강근 간격을 줄이고 크로스 타이를 배근할 경우 초기강성 및 최대하중이 증가하며 국부적인 응력집중이 감소하였다.
강진 시 원자력발전시설의 비선형 응답이 중요하기 때문에 이 시설의 내진성능에 대한 관심이 증가하였다. 이 연구에서는 원자력 발전소 철근콘크리트 전단벽의 유한요소해석을 위한 재료모델의 적절한 변수를 제시하였다: 최대인장강도, 팽창각, 손상계수. 이를 위해 상용 유한요소 해석프로그램인 ABAQUS를 사용하여 낮은 형상비를 가진 철근콘크리트 전단벽의 비선형 거동과 전단 파괴모드 에 대한 이 주요 변수의 효과에 대한 연구를 수행하였다. 연구결과에 기반하여 비선형 시간이력해석을 통해 강진 하의 원자로건물의 비선형 응답을 평가하였다.
최근 경주지진과 포항지진 피해사례에서 보이듯 조적벽체 구조물의 붕괴 위험이 사회적으로 큰 주목을 받고 있다. 본 연구는 수평하중에 대한 강성이 구조적으로 취약한 조적벽체 구조물에 대하여 개선된 보강재 설계 및 이를 통한 구조성능 평가를 수행하였다. 선행기술에서 제시한 FRP Plate 보강재의 경우 외부 부착 시 계면 부착파괴에 의한 보강성능 저감이 발생하는 것을 고려하여 본 연구에서는 사전제작 매립형 T-Joint BFRP 보강재를 개발하였으며, 이를 혼합 에폭시계 연성페인트와 혼합 하여 보강 구조물의 마감효과 및 에너지흡수성능을 개선하는 방법으로 제안하였다. 실험 결과, 보강 시험체의 강성은 약 1.37배, 에너지소산능력은 약 2.59배 개선됨을 확인하였다.
A shear wall is a structural member designed to effectively resist in-plane lateral forces, such as strong winds and earthquakes. Due to its efficiency and stability, shear walls are often installed in residential buildings and essential facilities such as nuclear power plants. In this research, to predict the results of the shaking table test of the three-story shear wall RC structure hosted by the Korea Atomic Energy Research Institute, three types of numerical modeling techniques are proposed: Preliminary, Calibrated 1, and Calibrated 2 models, in order of improvement. For the proposed models, an earthquake of the 2016 Gyeongju, South Korea (peak ground acceleration of 0.28 g) and its amplified earthquake (peak ground acceleration of 0.50 g) are input. The response spectra of the measuring points are obtained by numerical analysis. Good agreement is observed in the comparisons between the experiment results and the simulation conducted on the finally adopted numerical model, Calibrated 2. In the process of improving the model, this paper investigates the influences of the mode shape, material properties, and boundary conditions on the structure's seismic behavior.
Most commercial buildings among existing RC buildings in Korea have a multi-story wall-frame structure where RC shear wall is commonly used as its core at stairways or elevators. The members of the existing middle and low-rise wall-frame buildings are likely arranged in ordinary details considering building occupancy, and the importance and difficulty of member design. This is because there are few limitations, considerations, and financial burdens on the code for designing members with ordinary details. Compared with the intermediate or unique details, the ductility and overstrength are insufficient. Furthermore, the behavior of the member can be shear-dominated. Since shear failure in vertical members can cause a collapse of the entire structure, nonlinear characteristics such as shear strength and stiffness deterioration should be adequately reflected in the analysis model. With this background, an 8-story RC wall-frame building was designed as a building frame system with ordinary shear walls, and the effect of reflecting the shear failure mode of columns and walls on the collapse mechanism was investigated. As a result, the shear failure mode effect on the collapse mechanism was evident in walls, not columns. Consequently, it is recommended that the shear behavior characteristics of walls are explicitly considered in the analysis of wall-frame buildings with ordinary details.
Seismic fragility was assessed for non-seismic reinforced concrete shear walls in Korean high-rise apartment buildings in order to implement an earthquake damage prediction system. Seismic hazard was defined with an earthquake scenario, in which ground motion intensity was varied with respect to prescribed seismic center distances given an earthquake magnitude. Ground motion response spectra were computed using Korean ground motion attenuation equations to match accelerograms. Seismic fragility functions were developed using nonlinear static and dynamic analysis for comparison. Differences in seismic fragility between damage state criteria including inter-story drifts and the performance of individual structural members were investigated. The analyzed building had an exceptionally long period for the fundamental mode in the longitudinal direction and corresponding contribution of higher modes because of a prominently insufficient wall quantity in such direction. The results showed that nonlinear static analyses based on a single mode tend to underestimate structural damage. Moreover, detailed assessments of structural members are recommended for seismic fragility assessment of a relatively low performance level such as collapse prevention. On the other hand, inter-story drift is a more appropriate criterion for a relatively high performance level such as immediate occupancy.
This study introduces a newly developed PC non-bearing wall system to prevent the damage of RC wall-type apartments that have been heavily damaged by the 2017 Pohang Earthquake. In order to evaluate the performance of the developed PC non-bearing wall system, a static cyclic test is conducted. The prototype of test specimen is from the RC wall-type apartment which has been severely damaged by the 2017 Pohang Earthquake. The specimen with the conventional non-bearing wall system showed the similar damage of RC wall type apartment suffered from the Pohang Earthquake. In case of the specimen with the developed PC non-bearing wall system, cracks and damages were not transmitted between the walls due to the seismic slit and there were almost no cracks in the non-bearing walls. Therefore, the proposed non-bearing wall system, separated from the structural walls, could prevent spreading cracks to bearing walls and make it possible to effectively control damage due to earthquake loads.
본 연구에서는 다양한 변수를 갖는 병렬 RC 구조벽체시스템에 대한 성능기반설계의 타당성과 이에 따른 모멘트 재분배 개념의 적용성을 분석하기 위해 횡력을 지지하는 병렬 RC 구조벽체시스템에 대한 비선형해석을 수행하였다. 설계변수(철근 비, 콘크리트변형률, 벽체높이)가 병렬 RC 구조벽체시스템의 거동에 미치는 영향을 분석하였으며 이를 기반으로 병렬 RC 구조벽체시스템의 성능기반 설계를 위한 고려사항을 제안하였다. 비선형해석 결과, 병렬 RC 구조벽체시스템 성능기반 설계 와 모멘트 재분배 개념의 적용을 위해서는 연결보의 항복여부에 대한 고려가 필요한 것으로 나타났다. 높은 벽체의 경우, 연 결보가 항복하지 않고 탄성 상태로 거동할 수 있기 때문에 고층 병렬 RC 구조벽체시스템에 대해 성능기반 설계 및 모멘트 재분배 개념을 적용하기 위해서는 벽체에 높은 수준의 소성변형능력을 필요로 하며, 이를 위해 벽체 압축단부에 횡보강을 필수적으로 실시해야 한다.
In this study, nonlinear finite element analysis based on the Modified Compression Field Theory has been conducted to evaluate shear strength of RC walls with opening. On the analysis, reinforcement ratio within development length of rebars nearby the opening was reduced in the model in order to investigate the effect of opening on shear strength of RC shear walls. The nonlinear finite element analysis has been verified through comparison with the test result in literature. Through the verification, it was investigated that the analysis considering the development length of rebars well reflected the effect of an opening on shear strength of RC shear walls while current design provisions did not reasonably consider one.
This report offers an economically reasonable seismic reinforcement to non-seismic mid/low reinforced concrete structures. Installed a slit in between the reinforced concrete frame and masonry infilled wall then inserted twist bar to prevent inversion and attached to the lower/upper beam. Confirmed the seismic reinforcement effect through static loading test. Total of 4 specimens were produced for the test, a masonry infilled wall without seismic reinforcement and with seismic slit or twist bar applied. As a result, applying the seismic slit and twisted bar was economically reasonable and seismic reinforcement effect was confirmed by showing stable failure, increase of maximum strength and yield displacement, increase of accumulated energy dissipation.
Observations of the damages to high-rise reinforced concrete (RC) wall building structures caused by by recent earthquakes in Chile (Mw 8.8, February 2010) and New Zealand (February 2011, ML 6.3) have generally exceeded expectations. Firstly, this study estimated the seismic damage levels of 15-story RC box-type wall building structures using the analytical models calibrated by the results of a shaking table test on a 1:5 scale 10-story RC box-type wall building model. Then, the seismic fragility analysis of the prototype model was conducted by using the SAC/FEMA method and the incremental dynamic analysis (IDA). To compensate for the uncertainties and variability of ground motion and its impacts on the prototype model, in the SAC/FEMA method, a total of 61 ground motion records were selected from 20 earthquakes, with a magnitude ranging from 5.9 to 8.8 and an epicentral distance ranging from 5 to 105km. In the IDA, a total of 11 ground motion records were used based on the uniform hazard response spectrum representing a return period of 2,475 years. As a result, the probabilities that the limits of the serviceability, damage control, and collapse prevention would be exceeded were as follows: from the SAC/FEMA method: 79%, 0.3%, and 0%, respectively; and from the IDA: 57%, 1.7%, and 0%, respectively.
최근에 지어진 건축물의 경우 지진에 대한 안전성을 확보하고 있지만, 내진설계 도입 이전의 건축물은 지진에 대해 매우 취약하다. 본 연구에서는 내진성능이 부족한 기존 저층 RC구조물의 지진 발생 시 안전성 확보를 위한 내진보강 방안으로 격자강판 전단벽을 제안하고 내진성능평가를 수행하였다. 횡력저항요소로 사용된 격자강판 전단벽의 탄소성 이력특성값은 실험결과를 토대로 횡력저항 기여도등을 평가하여 작성된 이선형곡선을 적용하였다. 비탄성 정적해석을 통해 대상구조물의 성능점을 찾아내어 적용 지진하중에 대한 응답과 성능수준을 평가하였다. 격자강판 전단벽을 적용한 경우, 보강 전에 비하여 응답변위가 약 42% 저감되는 것을 확인할 수 있었으며, 성능점에서 거의 탄성거동을 보여주고 있어 목표성능인 인명안전수준을 만족시켰다. 또한 반응수정계수를 산정하여 내진보강 효과를 검증하였으며, 보강 전과 후에 각각 2.17에서 3.25로 증가하여 설계기준을 초과하였다. 따라서 격자강판 전단벽에 의해 대상 구조물의 강도 및 강성보강이 적절히 수행된 것으로 판단된다.
경계요소를 가지는 철근콘크리트 전단벽의 비선형 해석을 위한 간편 모델을 제안하였다. 이 간편 모델은 전단벽의 휨 및 전단 거동을 스프링요소로 나타낸 거시적 모델이다. 휨거동은 벽체의 단면해석을 기초로 한 모멘트강도와 회전능력을 벽체 양단의 수직 스프링요소로 나타내었다. 경계요소를 가지는 전단벽은 휨거동에 의해 지배되므로 전단거동은 휨거동에 바탕하여 변수를 계산하였고 중앙부 수평 스프링요소로 나타내었다. 제안된 모델은 전단벽 정적이력시험 결과와 비교한 후 비선형동적해석을 수행하여 사용된 이력법칙 및 변수들의 타당성을 조사하였다. 비선형동적해석을 이용한 변수연구를 통하여 내진성능평가의 주요변수인 요구값과 성능값에 미치는 영향을 검토하였다. 그 결과 전단력-전단변형 관계에서 약간의 차이가 있지만 전단벽의 전체거동은 잘 일치하였으며, 주요 변수의 변화에 대해 요구값과 성능값도 일정하게 변화하므로 제안된 해석모델은 경계요소를 가진 철근콘크리트 전단벽에 알맞은 것으로 판단된다.
국내에서 1990년대 설계된 철근콘크리트 내력벽시스템으로 설계된 공동주택에 대한 내진 성능평가를 연구하기 위하여 실제 시공된 13개 건물의 도면을 수집하고 해석을 수행하였다. 내진성능을 평가하기 위하여 FEMA 356과 FEMA 440에 따라 산정하였다. 요구곡선을 위하여 내진설계 스펙트럼은 건축구조설계기준(2009년)에서 정한 값을 사용하였다. 각 건물에 대하여 인명안전과 붕괴방지의 수준에 대한 성능점을 산정하였다. 붕괴방지수준에 대하여 성능점에 도달할 때의 부재의 상태를 확인하여 본 결과, 총 13개중 9개(약70%)의 건물의 연결보와 벽체에 붕괴방지 수준 이상의 손상이 발생하였으며, 내력벽보다 연결보에서 손상이 더 크게 나타났다. 또한 본 연구에서 산정한 성능점과 주기의 상관성을 고찰한 결과, 반비례의 상관성이 있음을 알 수 있었다.
본 실험 연구의 목적은 횡방향 정적가력을 통하여 2층 R.C 전단벽식 구조의 내진성능을 평가하는 것이다. 본 연구의 실험체는 대상 건물의 개구부를 가지는 T자형 벽체 1층과 2층의 일부분을 대상으로 실물크기의 3/5 크기정도로 축소하였고, 인방보의 유 무를 실험변수로한 2개의 실험체를 제작하여 횡방향의 정적가력 실험을 수행하였다. 인방보 유무에 따른 벽체의 구조적 성능 및 거동의 차이를 비교한 결과, 인방보가 있는 실험체가 인방보가 없는 실험체보다 최대내력과 연성능력 등의 내진성능이 우수한 것으로 판단되었다.
In this study, compare the results that used period of an object building and a structural analysis program in order to to analyze the effect that a slab element to oppose a vertical load opposes to lateral loading of a structure. Compared with to analyze the results to the Diaphragm which is existing analysis and a way do modeling to an plate element to slab element of RC wall type structures to give a change of rigidity with 100%, 50%, 30%
지진피해를 입은 건물의 주된 관심사는 건물에 남아 있는 내진성능 및 여진에 대한 안전성을 판단하는데 있다. 따라서 지진피해를 입은 지역 사회의 조속한 복귀를 위해서는 건물의 잔존내진성능 평가방법을 확립해 두는 것이 필수적이다. 본 연구에서는 무보강 조적채움벽체를 갖는 RC 건물의 잔존내진성능 평가방법 개발을 주목적으로, 전형적인 학교건물을 대상으로 축력레벨을 변수로 한 실스케일, 단층 1스팬 실험체를 제작하여 정적 반복가력실험을 실시하였다. 실험 중 잔존내진성능을 판정하는데 유용한 정보 중 하나인 잔류균열폭을 상세히 측정하였다. 본 논문에서는 잔류균열폭과 잔존내진성능과의 관계에 대해서 실험적, 해석적으로 검토하고 잔존내 진성능 평가를 위한 각 손상도 레벨에 대응하는 내진성능 저감계수를 제안한다.
기존의 하중-기반 방법을 대체할 방법중에 성능-기반 방법이 내진설계 및 내진성능평가의 기법으로서 널리 인식되고 있는 실정이다. 탄성응답스펙트럼을 사용하는 역량스펙트럼방법은 비선형 시스템을 등가의 선형시스템으로 치환하여 주어진 지진 하중에 대한 구조물의 최대 비선형 거동을 예측한다. 본 연구의 목적은 철근콘크리트 벽체구조물에 대하여 4개의 등가단자유도방법과 5개의 등가감쇠방법을 사용하여 역량스펙트럼방법의 정확성을 평가하는 것이다. 역량스펙트럼방법의 정확성을 평가하기 위하여 벽체구조물에 대한 진동대 실험결과와 비교하였다. 또한 이선형 곡선변환방법(등가에너지 근사화방법, 유효강성 사화 방법)에 의한 이선형 역량곡선들의 역량스펙트럼 해석에 대한 영향도 비교하였다.
본 연구의 목적은 초고층건물의 콘크리트 전단벽 아웃리거 두께를 산정하는 방법을 찾는 것이다. 이를 위해서 먼저 60층 규모의 초고층건물 해석모델을 생성하고 구조해석을 수행하였다. 다음에는 해석결과를 이용하여 아웃리거로 인한 하중 전달방식과 변형 양상의 변화를 고찰하고 이를 바탕으로 아웃리거 두께 산정식을 제안하였다. 마지막으로 해석모델을 다양하게 변화시켜 제안식의 타당성을 검토하였다.