검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 102

        61.
        2015.03 KCI 등재 서비스 종료(열람 제한)
        The photocatalytic decomposition characteristics of toluene, acetone, and methyl mercaptan (MM) by UV reactor installed with TiO2-coated perforated plane were studied. The removal efficiency of single toluene, acetone, and MM vapor was increased with increasing oxygen concentration, but decreased with increasing inlet concentration. Elimination capacity of single toluene, acetone, and MM vapor was obtained to be 628 g/m3․day, 1,041 g/m3․day, and 2,158 g/m3․day, respectively. Also, the photocatalytic decomposition of binary vapor consisted of toluene and acetone, toluene and MM, acetone and MM were observed. Elimination capacity of toluene mixed with acetone, toluene mixed with MM, acetone mixed with toluene, acetone mixed with MM, MM mixed with toluene, and MM mixed with acetone was 327 g/m3․day, 512 g/m3․day, 128 g/m3․ day, 266 g/m3․day, 785 g/m3․day and 883 g/m3․day, respectively. The inhibitory effect of acetone was higher than MM in photocatalytic decomposition of toluene, the inhibitory effect of toluene was higher than MM photocatalytic decomposition of acetone, and the inhibitory effect of toluene was higher than acetone in photocatalytic decomposition of MM.
        62.
        2015.03 KCI 등재 서비스 종료(열람 제한)
        The feasibility of PS-D2EHPA/TBP beads prepared by immobilizing two extractants D2EHPA and TBP in polysulfone to remove Sr(II) from aqueous solution was investigated in batch system. Batch experiments were carried out to study equilibrium isotherms, kinetics, and thermodynamics. Equilibrium data were fitted using Langmuir, Freundlich, Redlich– Peterson, and Dubinin-Radushkevich equation models at temperatures of 298 K, 313 K, and 328 K. The removal capacity of Sr(II) by PS-D2EHPA/TBP beads obtained from Langmuir model was 2.41 mg/g at 298 K. The experimental data were well represented by pseudo-second-order model. The removal process of Sr(II) by PS-D2EHPA/TBP beads prepared in this study was found to be feasible, endothermic, and spontaneous.
        63.
        2015.03 KCI 등재 서비스 종료(열람 제한)
        Due to a world trend on renewable energy, biomass that is one of renewable energy resources has to be applied at thermochemical process, actively. However, in commercial plant, one of many problems is an agglomeration production at biomass thermochemical process, because it leads to disturb continuous operation on thermochemical process. Thus, in this study, the EFB (empty fruit bunch), one of palm oil industry by-products was used as a biomass fuel, and washed by water and nitric acid solution (0.1wt.%) with different total washing times for resolving this problem at biomass thermochemical process. After washing, ash content was decreased from 5.9wt.% to 1.53wt.% using all of the washing treatments, and the Alkali & Alkaline Earth Metallic (AAEM) was removed over 80wt.% of total AAEM, such as potassium, magnesium, calcium and sodium. Additionally, SEM with XRD was analyzed to confirm the characteristics of produced agglomeration, and the agglomeration production ratio was measured: it revealed that the ratio was resulted in decrease over half, in the case of using all of washed EFBs.
        64.
        2015.01 KCI 등재 서비스 종료(열람 제한)
        Removal characteristics of Cu(II) ions by solid-phase extractant immobilized D2EHPA and TBP in PVC were investigated. Cu(II) ion concentrations in the solution and removal capacity of Cu(II) ion according to operation time were compared. The lower the initial concentration of Cu(II) ion in aqueous solution was, the removal capacity of Cu(II) ion by solid-phase extractant was increased relatively. The bigger the initial concentration of Cu(II) ion was, the removal capacity of Cu(II) ion was increased relatively. The pseudo-second-order kinetics according to operation time was showed more satisfying results than the pseudo-first-order kinetics for the removal velocity of Cu(II) ion. The removal capacity of Cu(II) ion was 0.025 mg/g in aqueous solution of pH 2, but the removal capacity of Cu(II) ion was increased to 0.33 mg/g mg/g in aqueous solution of pH 4 according to increasing pH.
        65.
        2015.01 KCI 등재 서비스 종료(열람 제한)
        The solid-phase extractant PS-D2EHPA/TBP was prepared by immobilizing two extractants D2EHPA and TBP in polysulfone (PS). The prepared PS-D2EHPA/TBP was characterized by using fourier transform infrared spectrometer (FTIR) and scanning electron microscopy (SEM). The removal of Cu(II) from aqueous solution was investigated in batch system. The experiment data were obeyed the pseudo-second-order kinetic model. Equilibrium data were well fitted by Langmuir model and the removal capacity of Cu(II) by solid extractant PS-D2EHPA/TBP obtained from Langmuir model was 3.11 mg/g at 288 K. The removal capacity of Cu(II) was increased according to increasing pH from 2 to 6, but the removal capacity was decreased below pH 3 remarkably.
        66.
        2014.09 KCI 등재 서비스 종료(열람 제한)
        PVA-D2EHPA/TOPO beads containing two extractants, di-(2-ethylhexyl) phosphoric acid (D2EHPA) and trioctylphoshine oxide (TOPO) were prepared for the removal of copper ions from aqueous solution. The prepared PVA-D2EHPA/TOPO beads were characterized by SEM and FT-IR. The removal characteristics of copper ions by PVA-D2EHPA/TOPO beads was investigated using batch and continuous systems. In batch experiments, the maximum removal capacity calculated from Langmuir isotherm model was 18.6 mg/g and the optimal pH was in the range of 4.5 ∼6. The continuous experiments showed that the removal capacity of copper ions increased with increasing inlet copper ion concentrations and bed heights, but decreased with increasing inlet flow rates.
        67.
        2014.09 KCI 등재 서비스 종료(열람 제한)
        In this study the production of methane gas and the removal efficiency of nutrients in the anaerobic co-digestion facilitieswith food waste/food waste leachate (FWL), animal manure and food waste leachate (A-MIX), and sewage sludge andfood waste leachate (S-MIX) were investigated. The average amount of the theoretical methane production was 578.4CH4·L/kg·VSin from the anaerobic digestion facilities with FWL, 606.0CH4·L/kg·VSin from those with A-MIX and 570.0CH4·L/kg·VSin from those with S-MIX, respectively. The amount of the practical methane production was 350.7CH4·L/kg·VSin from the anaerobic digestion facilities with FWL, 379.5CH4·L/kg·VSin from those with A-MIX and 348.8CH4·L/kg·VSin from those with S-MIX, respectively. The nutrient compositions of FWL were 3.2g/100g for carbohydrates, 1.8g/100g for proteins and 1.9g/100g for lipids. The nutrient compositions of A-MIX were 0.4g/100g for carbohydrates,2.55g/100g for proteins 0.4g/100g and 0.7g/100g for lipids, respectively. The nutrient compositions of S-MIX were0.4g/100g for carbohydrates, 2.4g/100g for proteins 1.6g/100g and 0.4g/100g for lipids, respectively. The removalratio of carbohydrate was very high over 75% in all facilities and that of lipid was very low below 25%.
        68.
        2014.07 KCI 등재 서비스 종료(열람 제한)
        The aim of this paper is to compare the characteristics of the T-P removal from synthesized municipal wastewater by electro-coagulation using cylindrical Al and Fe electrode as anode. For this purpose, a concentric circle type electrolysis reactor was used and the operating conditions for T-P removal from synthesized wastewater are as follows; potential 10 V, electrolyte 0.03% NaCl, initial T-P concentration 1.0 ~ 6.0 mg/L and flow rate 1.0 ~ 5.0 L/min. From the experimental results, T-P concentration of treated wastewater was decreased to less than 0.2 mg/L enough to discharge standard and Al electrode showed performance than Fe electrode for T-P removal by electro-coagulation. Optimal conditions for T-P removal to less than 0.15 mg/L which is 75% of discharge standard for large scale municipal wastewater plant (capacity higher than 500 m3/day) were obtained as follows; flow rate 2.503 L/min, and 2.337 L/min, HRT 1.059 min, 1.134 min, for Al and Fe electrode, respectively. Consumed mass of Al and Fe were of 3.76 times and 8.90 times respectively, were obtained to removed T-P at optimal conditions with potential 10 V, and 0.03% NaCl as electrolyte.
        69.
        2014.07 KCI 등재 서비스 종료(열람 제한)
        The aim of this paper is to compare the characteristics of the T-P removal from synthesized municipal wastewater by electro-coagulation using cylindrical Al and Fe electrode as anode. For this purpose, a concentric circle type electrolysis reactor was used and the operating conditions for T-P removal from synthesized wastewater are as follows; potential 10 V, electrolyte 0.03% NaCl, initial T-P concentration 1.0 ~ 6.0 mg/L and flow rate 1.0 ~ 5.0 L/min. From the experimental results, T-P concentration of treated wastewater was decreased to less than 0.2 mg/L enough to discharge standard and Al electrode showed performance than Fe electrode for T-P removal by electro-coagulation. Optimal conditions for T-P removal to less than 0.15 mg/L which is 75% of discharge standard for large scale municipal wastewater plant (capacity higher than 500 m3/day) were obtained as follows; flow rate 2.503 L/min, and 2.337 L/min, HRT 1.059 min, 1.134 min, for Al and Fe electrode, respectively. Consumed mass of Al and Fe were of 3.76 times and 8.90 times respectively, were obtained to removed T-P at optimal conditions with potential 10 V, and 0.03% NaCl as electrolyte.
        70.
        2014.06 KCI 등재 서비스 종료(열람 제한)
        The solid phase extractant (PVC-D2EHPA bead) was prepared by immobilizing di-2-ethylhexyl-phosphoric acid (D2EHPA) with polyvinyl chloride (PVC). The prepared PVC-D2EHPA beads were characterized by using fourier transform infrared spectrometer (FTIR) and scanning electron microscopy (SEM). The removal experiments of Cu(II) by PVC-D2EHPA beads conducted batchwise. The removal kinetics of Cu(II) was found to follow the pseudo-second-order model. The equilibrium data fitted well with Langmuir isotherm model and the maximum removal capacity was 2.6 mg/g at 20℃. The optimum pH region was in the range of 3.5 to 6. and the standard free energy (△Go) was between –4.67 ∼–4.98 kJ/mol, indicating the spontaneous nature of Cu(II) removal by PVC-D2EHPA beads.
        71.
        2013.11 KCI 등재 서비스 종료(열람 제한)
        The adsorption ability of wood-based activated carbon to adsorb methylene blue (MB) and crystal violet (CV) from aqueous solution has been investigated. Adsorption studies were carried out on the batch experiment at different initial MB and CV concentrations (MB=150 mg/L~400 mg/L, CV=50 mg/L~350 mg/L), contact time, and temperature. The results showed that the MB and CV adsorption process followed the pseudo-second-order kinetic and intraparticle diffusion was the rate-limiting step. Adsorption equilibrium data of the adsorption process fitted very well to both Langmuir and Freundlich model. The maximum adsorption capacity (qm) by Langmuir constant was 416.7 mg/g for MB and 462.4 mg/g for CV. The thermodynamic parameters such as ΔH°, ΔS° and ΔG° were evaluated. The MB and CV adsorption process was found to be endothermic for the two dyes.
        72.
        2013.01 KCI 등재 서비스 종료(열람 제한)
        The removal characteristics of composite odor and malodorous substances using 33 biofilters in sewage treatment facilities were investigated. The geometry mean values of composite odor and odor quotient were reduced by 52.7% and 59.2% at the outlet of the biofilters, respectively. The removal efficiencies of the biofiltes for the composite odor and odor quotient show a significant difference statistically(p=0.000<0.05). The median value of odor quotient of sulfur compounds was reduced by 69.1% at the outlet of the biofilter and the odor quotient of the sulfur compound at the inlet and outlet of the biofilter shows a significant difference statistically(p=0.000<0.05); on the other hand, those of the NH3 and trimethylamine, aldehydes, VOCs and alcohols, organic acids do not.
        73.
        2011.02 KCI 등재 서비스 종료(열람 제한)
        In this research, equilibrium of adsorption and kinetics of As(V) removal were investigated. The coal mine drainage sludge(CMDS) was used as adsorbent. To find out the physical and chemical properties of CMDS, XRD (X-ray diffraction), XRF (X-ray fluorescence spectrometer) analysis were carried out. The CMDS was consist of 70% of goethite and 30% of calcite. From the results, an adsorption mechanism of As(V) with CMDS was dominated by iron oxides. Langmuir adsorption isotherm model was fitted well more than Freundlich isotherm adsorption model. Adsorption capacities of CMDS 1 was not different with CMDS 2 on aspect of amounts of arsenic adsorbed. The maximum adsorption amount of two CMDS were respectively 40.816, 39.682 mg/g. However, the kinetic of two CMDS was different. The kinetic was followed pseudo second order model than pseudo first order model. Concentrations of arsenic in all segments of the polymer in CMDS 2 does not have a constant value, but the rate was greater than the value of CMDS 1. Therefore, CMDS 2, which is containing polymer, is more effective for adsorbent to remove As(V).
        74.
        2010.04 KCI 등재 서비스 종료(열람 제한)
        The purpose of this study is to investigate the effect of influent phosphorus concentration on the nitrogen and phosphorus removal in sequencing batch reactor(SBR) and sequencing batch biofilm reactors(SBBRs) in order to recover the enhanced biological phosphorus removal (EBPR) capacity at the sludge of the deterioration of EBPR capacity. In SBBRs, comparing to SBR, the organic removal was occurred actively at the 1st non-aeration period because of the active phosphorus release at this period. However, the variation of TOC removal according to the decrease of influent phosphorus concentration was not clearly shown both in SBR and SBBRs. In case of SBR losing EBPR capacity, the EBPR capacity was not recovered by the decrease of the influent phosphorus concentration from 7.5 mg/L to 0.9 mg/L. The nitrogen removal increased by the decrease of influent phosphorus concentration both in SBR and SBBRs.
        75.
        2009.12 KCI 등재 서비스 종료(열람 제한)
        본 연구는 립선별기에서 미숙립 선별능력을 높임으로써 도정효율 증진과 완전미율 향상을 꾀하고자 품종특성을 고려한 립선별기 선별체 최적 조건 구명 시험이 수행되었고, 다음과 같은 결과가 얻어졌다. 1. 립선별기의 선별능력은 현미립 두께에 절대적으로 의존되었는데, 조사된 시험재료의 현미 평균 두께는 1.79(농안)-2.16 mm(대립벼1호)의 분포를 보였다. 2. 품종별 차이는 있었으나, 대체적으로 현미의 평균 립두께가 2.08 mm이상일 경우 1.9 mm 선별체, 2.00-2.08 mm 범위일 경우 1.8 mm 선별체, 1.90-2.00 mm 범위일 경우 1.7mm 선별체, 그 이하일 경우 1.7 mm 이하의 선별체가 정립 손실을 최소화하면서(0.1%이내) 완전미율을 향상시킬 수 있는 조건인 것으로 판단되었다. 3. 백미 품위에 미치는 선별체 분리효과는 미숙립 비율이 높은 품종일수록 크게 발휘되었다. 4. 현미선별 체 눈 크기를 0.1 mm씩 증가시킬 경우 품종별로 현미선벌체 통과물중에 정상립이 포함되어 발생되는 정상립 손실율이 0.5% 수준까지는 현미선별체 눈금크기 증가에 따라 미미하게 증가하였으나, 이 눈금 수준이상에서는 선별체 눈금 0.1 mm 증가에 따라 정상립의 손실율이 급격히 증가하는 것으로 보아 정상립 손실율 0.5% 수준의 눈금이나 그 보다 0.05~0.10 mm 아래 눈금의 선별체가 적당할 것으로 생각되었다.
        76.
        2009.04 KCI 등재 서비스 종료(열람 제한)
        The removal characteristics of total petroleum hydrocarbons (TPHs) and heavy metals in contaminated soils with ultrasonic washing have been studied. The ultrasonic washing was evaluated on a laboratory scale. In this investigation, the effects of factors such as ultrasonic frequency, power intensity, duration of irradiation, contents of the TPHs and heavy metals and mixing ratios between the contaminated soils and water, were considered. Experimental results suggested that the rates for contaminant extraction of the TPHs and heavy metals in the contaminated soil increased considerably with the ultrasonic washing. Therefore, the ultrasonic washing has previously been to be an effective method to remediate the contaminated soils with the TPHs and heavy metals.
        77.
        2008.11 KCI 등재 서비스 종료(열람 제한)
        Aerated submerged bio-film (ASBF) pilot plant has been developed. The presented studies optimized an inexpensive method of enhanced wastewater treatment. The objectives of this research were to describe pilot scale experiments for efficient removal of dissolved organic and nitrogen compounds by using ASBF reactor in plug-flow reactor (PFR) and improve understanding of dissolved organic matter and nitrogen compounds removal rates with dynamic relationships between heterotrophs and autotrophs in the fixed-film reactor. This research explores the possibility of enhancing the performance of shallow wastewater treatment lagoons through the addition of specially designed structures. This direct gas-phase contact should increase the oxygen transfer rate into the bio-film, as well as increase the micro-climate mixing of water, nutrients, and waste products into and out of the bio-film. This research also investigated the efficiency of dissolved organic matter and ammonia nitrogen removals in the ASBF. As it was anticipated, nitrification activity was highest during periods when the flow rate was lower, but it seemed to decline during times when the flow rate was highest. And ammonia nitrogen removal rates were more sensitive than dissolved organic matter removal rates when flow rates exceeded 2.2 L/min.
        78.
        2008.03 KCI 등재 서비스 종료(열람 제한)
        The fate of two cyclic ethers, THF(Tetrahydrofuran) and 1,4-Dioxane, in conventional biological wastewater treatment plants was investigated using sequential activated sludge process. Removal efficiency of THF were about 86% in average, which was greater than that of 1,4-Dioxane, 30%. However, it was not clear whether the removal of cyclic ethers in biological system was caused by microbial activity or not. Thus treatability tests were conducted by batch experiments. The effects of mixing, aeration and the addition of activated sludge on the removal of cyclic ethers were investigated in batch experiments. THF was totally removed by mixing and aeration in 24 hours while removal ratio of 1,4-Dioxane was at most 30% for the same period. This results could be ascribed to the differences in Henry's law constants between the two chemicals. In addition, biological degradation including biosorption was not obviously observed in these batch tests.
        79.
        2007.07 KCI 등재 서비스 종료(열람 제한)
        Laboratory scale experiments were conducted to investigate the removal characteristics of nitrogen and phosphorus in two sequencing batch biofilm reactors (SBBRs). SBBR1 had a short first non-aeration period and SBBR2 had a long first non-aeration period. The removal characteristics of nitrogen and phosphorus in each SBBR were precisely observed according to the variation of influent TOC concentration, and the operation control parameters (pH, DO concentration, ORP) in each reactor were measured. In biological nitrogen removal, there was little difference between SBBR1 and SBBR2 and the nitrogen removal efficiencies were very low. The nitrogen and phosphorus removal characteristics in high influent TOC concentration were different from those in low TOC. Nitrogen removals by simultaneous nitrification/denitrification (SND) were occurred in both SBBR1 and SBBR2. The P removal in SBBR1 was superior to that in SBBR2. The second P release was observed in SBBR1 which had long second non-aeration period.
        80.
        2007.06 KCI 등재 서비스 종료(열람 제한)
        This study compared the performance of a bioscrubber, a biofilter, and a combined system of bioscrubber and biofilter employed being operated at the laboratory-scale. for the removal of hydrogen sulfide. The bioscrubber maintained 100% removal of hydrogen sulfide up to inlet load of 56 g-S/m3․hr, while the removal efficiency was decreased with the increase of inlet load. The biofilter showed 100% removal efficiency up to inlet load of 126 g-S/m3․h and the maximum elimination capacity of 126 g S/m3․h for the inlet load of 224 g-S/m3․h. On the other hand, the combined system of bioscrubber and biofilter showed 100% removal for an inlet hydrogen sulfide load of up to 85 g-S/m3․h and the maximum elimination capacity of 153 g-S/m3․h for inlet loads of 224 g-S/m3․h.
        1 2 3 4 5