The arrival of the 5G era has made electromagnetic pollution a problem that needs to be addressed, and flexible carbon-based materials have become a good choice. In this study, wet continuous papermaking technology was used to prepare carbon fiber paper (CFP) with a three-dimensional conductive skeleton network; Molybdenum disulfide ( MOS2)/ iron (Fe) @ carbon fiber paper-based shielding material was prepared by impregnating and blending molybdenum disulfide/iron ( MOS2/Fe) phenolic resin MOS2/ Fe@ CFP. The morphology, structure, electrical conductivity, mechanical properties, hydrophobicity, and electromagnetic shielding properties of the composite were characterized. The results show that the three-dimensional network structure based on a short carbon fiber paper-based conductive skeleton and the synergistic effect of the MOS2 dielectric wave absorbing agent and Fe magnetic wave absorbing agent have good electromagnetic shielding performance. Conduct electromagnetic shielding simulation using HFSS software to provide options for the structural design of CFP. The electromagnetic shielding performance of CFP reaches 70 dB, and the tensile strength reaches 34.39 MPa. Based on the mechanical properties, the compactness of carbon fiber paper is ensured. The lightning damage model test using CST software expands the direction for the use of carbon fiber paper. In summary, MOS2/ Fe @CFP with excellent shielding performance has great application prospects in thinner and lighter shielding materials, as well as high sensitivity, defense and military equipment.
탄소섬유 강화 플라스틱 (Carbon fiber reinforced plastics, CFRP)은 고함량의 탄소섬유 (Carbon fiber, CF)와 고분자로 이루어진 복합재료로서, 뛰어난 기계적 성능으로 항공우주, 자동차, 토목 등 다 양한 산업 분야에서 사용되고 있다. 하지만 사용량 증가에 따른 폐기물의 환경문제와 추출한 재활용 탄소섬유 (Recycled carbon fiber, rCF)의 적용 가능 분야의 한계로 인해 재활용이 제한적인 실정이 다. 본 연구에서는 rCF와 CF 혼입 시멘트계 전자파 복합재를 제작하여 그 성능을 비교 분석하기 위 한 실험을 수행하였다. 구성재료는 시멘트, 잔골재, 고성능 감수제를 사용하였으며, 비교 분석을 위해 CF와 rCF를 각각 6 mm, 12 mm 길이를 0.1, 0.3, 0.5, 1.0 wt.% 함량으로 사용하였다. 전자파 복합 재의 흡수 성능 향상을 위해 각각 다른 함량의 다층 구조를 형성하였으며, 전자파 투과를 낮은 함량에 서 높은 함량 방향이 되도록 측정을 진행하였다. 전자파 차폐성능은 재령 28일 이후 네트워크 분석기 를 사용하여 자유 공간에서 측정하였으며, C-band (4~8 GHz)와 X-band (8~12 GHz) 주파수 영역 에서의 반사율과 투과율을 각각 측정하였다.
Lightweight and flexible electromagnetic interference (EMI) shielding materials are in great demand for wearable EMI device. In the present work, lightweight and flexible carbon nanotube (CNT)/ferroferric oxide ( Fe3O4) composite film was made through a feasible chemical vapor deposition process for CNT film synthesis, followed by a hydrothermal reduction process for Fe3O4 coating. In the as-prepared composite, CNT film and Fe3O4 particles work as conductive skeleton and strong magnetic particle, respectively. The as-prepared composite film shows a novel EMI shielding effectiveness (SE) of 91 dB in the X-band, a small thickness of 0.09 mm and a low density of 0.86 g/cm3, which is superior to most of the carbonbased EMI materials.
In this study, we quantitatively analyzed the data by measuring the radiation shielding rate and uniformity in order to evaluate the performance of an Apron. In addition, storage conditions were also evaluated. The uniformity measurement was performed by evaluating the Apron DICOM images using a PACS program. The experiment was intended for 51 Aprons being used in three hospitals in the Daejeon area. The radiation shielding rate and uniformity were measured per lead equivalent for 0.25 mmPb, 0.35 mmPb, and 0.5 mmPb. As a result, the higher lead equivalents were, the greater differences in the non-uniformity between the top part and the bottom part became (p=0.020). In all hospitals, regarding the non-uniformity of four places in Aprons, all showed statistically significant differences (p<0.01). The average value of the transmitted radiation dose showed less difference (p = 0.005) in the bottom right than in the upper right but was statistically significant. There have been no marks of manufacturing date or the date of purchase in the Apron.
첨단산업의 발전으로 재활용이 어려운 산업부산물의 발생량이 증가하고 있으며, 건설산업에서는 골재 수급이 부족한 실정이다. 이에 본 연구에서는 중금속이 함유된 폐브라운관 유리를 잔골재로 100% 대체하고 전기로 산화슬래그를 굵은골재로 대체한 콘크리트의 감마선 차폐효율을 진단하여, 산업폐기물로 납과 철의 함유량을 높인 콘크리트의 차폐콘크리트 적용성을 검토하였다. 연구 결과, 일반 굵은골재를 사용한 콘크리트보다 반가층이 감소하는 경향을 나타냈으며, 중금속을 함유한 산업폐기물의 적용으로 고밀도의 콘크리트 제조가 가능할 것으로 사료된다.
이 연구는 고성능 섬유보강 복합체(HPFRCC)의 전자파 차폐성능을 향상시키기 위한 목적으로 전기전도도, 전자파 차폐능, 역학적 강도를 조사하였다. 강섬유, 제강슬래그 미분말, 카본블랙이 전도성재료소 HPFRCC 배합에 첨가되었다. 또한, MWCNT를 수 분산 시켜 제조된 2% wt. CNT 용액을 사용하였다. 실험 결과, HPFRCC의 전기전도도는 1% 카본블랙이 첨가된 시편을 제외하고는 매우 낮은 특성을 보였다. 시멘트 매트릭스의 미세구조는 시간에 따라 변하였고, 그로 인해 HPFRCC의 전기전도성 네트워크에 부정적인 영향을 끼쳤다. 0.083 S/cm의 전도도를 갖는 HC1 시편의 경우, 수분에 의한 효과를 배제하기 위하여 72시간 60도에서 건조 양생한 후에 측정한 전기전도도가 0.0003 S/cm로 상당히 감소하였다. 전자파 차폐 성능에 가장 중요한 인자는 강섬유인 것으로 나타났으며, 반면 카본블랙과 제강슬래그 미분말의 효과는 미미하였다. 전기전도도와 전자파 차폐능의 상관관계는 이 연구에서는 뚜렸한 경향성을 나타내지는 않았다.
건전자제품의 개발과 생산기술에 비교하여 폐유리의 재활용을 위한 기술개발은 상대적으로 미흡하여 자원낭비와 환경오염이 가속화되고 있다. 해외에서는 이 분야에 대한 기술개발이 활발하게 이루어지고 있으나 국내의 경우, 그 관심도가 부족하여 폐유리를 불법투기 또는 매립으로 처리하고 있는 실정이다. 폐유리는 시멘트와 수화반응시 포졸란 반응가능성이 있는 것으로 확인되어 경화 콘크리트의 물리적 성질을 향상시키고 굳지 않은 콘크리트의 레올로지 특성을 개선하여 블리딩의 저감 및 수화열 발생의 억제 등에 효과적인 것으로 보고되고 있다. 따라서 본 논문에서는 폐유리를 잔골재로 사용한 차폐콘크리트의 알칼리-실리카반응이 팽창에 미치는 영향을 분석하고 폐유리 혼입에 의한 알칼리-실리카반응의 팽창을 억제하기 위한 방안으로 적정 혼화재료를 사용하여 차폐콘크리트의 내구성능을 평가하였다.
In this study, it evaluate the electromagnetic pulse shielding performance of fiber reinforced cement composite by Fiber type. Hooked-ended steel fiber, Smooth steel fiber and Amorphous metallic fiber were reinforced 2.0 vol.% in cement composites respectively. The electromagnetic pulse shielding performance was evaluated by MIL-STD-188-125-1.
연구에서는 기존의 납을 대체할 수 있는 의료 방사선 차폐제품 적용을 위해 몬테카를로 시뮬레이션을 통해 바륨화합물의 두께별 차폐능을 모의 추정하였다. 차폐재 물질로는 황산바륨(BaSO4)을 이용하였고, 시편의 면적은 15 × 15 ㎠, 황산바륨의 밀도는 4.5 g/㎤ , 납의 밀도 11.34 g/㎤를 적용하여 차폐재 시편의 두께를 0.1 ㎜부터 5 ㎜까지 시뮬레이션 하였다. 입력 선원은 연속 X-ray 에너지 스펙트럼(40 kVp ∼ 120 kVp)에서 10kVp Step으로 시뮬레이션하였다. 40 kVp ∼ 60 kVp에서의 흡수확률은 3 ㎜ ∼ 5 ㎜ 두께에서는 납과 동일한 차폐능을 나타내었으나, 2 ㎜ 이하에서는 차폐능이 기존 납 차폐재에 비해 다소 차폐능이 떨어지는 결과로 나타났다. 또한 70 kVp ∼ 120 kVp 에너지대역에서의 차폐능은 기존 납 차폐재와 유사한 성능을 보였지만, 0.5 ㎜ 이하에서는 다소 낮은 차폐능으로 모의 추정되었다. 본 연구는 몬테카를로 시뮬레이션을 통해 의료용 엑스선 에너지 대역에 대한 두께 함수로써 바륨화합물의 차폐능을 추정하여 기존의 납과 비교 분석하였다. 또한 순수한 황산바륨의 의료용 방사선 차폐제품 적용가능성을 검증하고자 하였다. 그 결과 의료 방사선 에너지 대역 70 kVp ∼ 120 kVp 에서 최소 2 ㎜ 이상의 바륨화합물 두께에서 기존납 1.5mm 대비 95% 이상의 차폐효과가 있는 것으로 추정되었으며, 본 결과는 의료용 방사선 차폐제품의 경량화 제작에 기초 자료로 제공될 수 있을 것으로 사료된다.