검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 28

        1.
        2024.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to prevent disconnection of the hydraulic pump EDV cable, this study judged the vibration generated by the pump as the greatest effect on disconnection, and confirmed the vibration effect. And it had a structure that was vulnerable to vibration because of the wire flow space inside the EDV cable connector. After applying the improved adapter, vibration analysis, excitation test, and bending strength test were performed to confirm the effectiveness of design change and improvement. As a result of vibration analysis, the amount of vibration was reduced by about 10 times compared to the existing product, and the strength increased by about 4 times in the bending strength test was confirmed to increase the effect of preventing disconnection due to vibration.
        4,000원
        3.
        2019.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the yaw misalignment value of wind turbine was measured using Lidar and it was analyzed the effect of vibration reduction and power performance improvement when applied to turbine. It was confirmed that the vibration of the main bearing and the gear box of the wind turbine was partially reduced. Also it was found that the output performance was improved when the wind speed was over 8m/s. As a result, it was also found that the annual energy production(AEP) was improved when the average annual wind speed of the wind farm was over 6m/s. Converted to AEP, the AEP improved about 1% and 4%, when the annual wind speed was 6m/s and 11m/s respectively, which resulted in an improvement of about 1~4% through the yaw misalignment correction of the wind turbine.
        4,000원
        4.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The characteristics and effectiveness of double tuned mass dampers (DTMD) have been studied by many researchers. DTMD usually consists of one larger mass block and one smaller mass block. In this study, DTMD was proposed to reduce the vibration of vertical pumps in industrial plants. In order to assess the efficiency of the proposed method, numerical analysis for the simplified vertical pump model with single and double TMDs was carried out. It was also investigated that the effects of optimal TMD parameters such as frequency ratio and damping ratio on dynamic responses of the main structure. According to analysis results, DTMD are more effective to control the vibration of the vertical pump and show good robustness to the change in the stiffness of TMD.
        4,000원
        5.
        2017.04 구독 인증기관 무료, 개인회원 유료
        Wind tower structure has relatively simple shape compared to other structures, but due to its characteristics, various and irregular environmental loads are applied. These loads cause vibrations at tower, and can cause failure of the structure if over vibration occurs. Vibration occurred at structures is gradually exhausted by damping of the structures, and if high damping is ensured, the failure of the structure due to over vibration can be prevented. In this study, the vibration reduction effects are to be analyzed through FEM analysis by examining the top displacement, bottom moment, and bottom fatigue damage of the structure depending on damping ratio of the wind tower structure.
        3,000원
        6.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 고강도 운동 후 전신진동이 근피로도 감소와 심박회복율에 미치는 효과를 알아보고자 하였다. 피험자 는 총 20명으로 진동을 제공받는 그룹과 진동을 제공받지 않는 그룹으로 구성되어 있다. 고강도 운동은 경사 8.5도와 보행속도 4km/h를 30분간 제공하였고, 그룹별 진동유무별 의자형 진동기 위에서 30분간 휴식을 취하였다. 전신진동자 극은 10Hz의 진동주파수와 5mm의 진폭을 제공하였다. 진동유무별 피로도 감소와 심박안정화 효과를 검증하기 위해 혈중 젖산농도와 실시간 심박수 변화를 측정하였다. 실험결과, 진동을 제공받는 그룹에서 95.2% 수준의 더 큰 근피로도 감소결과와 50.67%의 더 빠른 심박회복율 결과를 보였다. 이는 고강도 운동 후 전신진동이 근육속 혈관을 지속적으로 자극하여 운동 후 초과산소섭취를 빠르게 해소하고 혈액순환 기능을 증진시켜 피로도를 감소시킨다. 고강도 운동 후 전신진동을 이용한 휴식은 노약자나 여성들에게 운동 후 다른 육체적 활동 없이 마무리운동으로 긍정적 효과를 기대할 수 있다.
        4,000원
        7.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        해상풍력발전의 건설이 여러 가지 환경 및 가설공법 등의 설치환경 등의 원인에 의하여 건설지점이 천해에서 심해로 이동하는 경향을 나타내고 있다. 이러한 경향 속에 해상풍력발전 지지구조물의 심해화에 따른 지지구조물에 대한 연구는 중요성이 더욱 증대될 것으로 판단된다. 본 연구에서는 기존의 Jacket 구조물에 대하여 Precast Concrete Block 및 Suction pile을 적용한 Jacket 구조물을 제안하고 이에 대하여 구조해석 및 안전성 평가를 실시하였다. 또한 제안된 구조물에 동조액체감쇠기를 적용하여 구조물 진동성능 향상을 도모하고자 하였다. 연구결과, 제안된 신형식 Jacket 구조물은 충분한 안전성을 가지고 있는 것으로 평가되었으며, 동조액체감쇠기를 적용하였을 경우, 약 5%의 진동저감 효과가 있는 것으로 검토되었다.
        4,000원
        8.
        2014.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Abnormal cab vibrations in the Y direction in commercial vehicles during driving(70~90kph) are not common vibrations that happen to vehicles during driving and can be an obstacle to normal driving. This study conducted Operation Deflection Shape(ODS) testing to identify the causes of those abnormal cab vibrations and find solutions for them and also a sine sweep test to find resonance and frequency in the cab suspension system and set directions for improvement. The study also altered the shape of the bush inner part for changes to the rigidity features of the cab bush in the Y direction and revised the design with optimal rigidity in the Y direction, thus improving abnormal cab vibrations in the Y direction during driving.
        4,000원
        9.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        2011년 7월 서울시 구의동에 위치한 테크노마트 건물(39층)에서의 이상진동은 대한건축학회의 원인조사 결과, 휘트니스센터(12층)에서의 집단리듬운동에 의한 건물 전체의 연직진동모드의 공진현상으로 확인되었다. 본 연구에서는 연직진동의 특성과 이를 제어하기 위한 TMD의 설계 및 성능시험에 대하여 기술하고, TMD 설치에 따른 건물 유효감쇠비의 증가량과 진동저감 효과, 그리고 연직진동에 대한 거주성능의 개선정도를 정량적으로 평가하였다.
        4,000원
        11.
        2012.12 KCI 등재 구독 인증기관·개인회원 무료
        In this study, a theoretical investigation of optimized sleeper spacing which can suppress resonances of a railway track is attempted. To achieve this, we introduced a minimization problem in which the objective function is given by the wave transmittance and the design variable is defined by sleeper distribution. In the analysis the rail is modeled by a Timoshenko beam and the sleeper is represented by a mass. The infinite track analysis is realized by attaching the transmitting boundaries at both ends of the finite optimization region. Through numerical analyses the sleeper spacing effective in reduction of the transmittance is discussed. Furthermore, the feasibility of the proposed method is validated in the aspect of vibration reduction through response analyses for a harmonic load.
        12.
        2011.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        When the trains are passed the station, a serious force is applied to ground and the caused vibration is propagated to the area of the station by the ground and rocks. The caused vibration brings about the operation interruption of the equipment which is sensitive to the vibration, or will bring about the structural damage of the station. In this study, to investigate the vibrational evaluation of railway station by the train service, the vibration simulation was performed and analyzed the effect of the vibration isolating countermeasure. From the vibration measurement, all trains that passed through the station exceeded the vibration criteria. Therefore, the vibration isolating countermeasure was established and the vibration simulation was performed.
        4,000원
        13.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 풍진동제어를 위한 제어기 설계에 있어서 시스템식별에 기반한 모델의 차수 축소가 미치는 영향을 검토하였다. 실제 제어기 설계에 있어서 구조해석 모델이 이용될 수 없고 시스템식별이라는 중간과정을 거쳐서 얻어진 모델이 적용됨을 반영하여 원모델을 대상으로 풍하중에 대한 시간이력해석을 수행하고 이를 기초로 시스템식별을 수행하였다. 시스템식별을 통해 얻어진 상태방정식 모델에 모델축소 기법을 적용하였으며, 시스템식별에서 발생하는 측정잡음이 측정잡음이 모델의 정확도와 제어효과에 미치는 영향을 함께 검토하였다. 또한 모델축소 기법을 적용하여 얻어진 다양한 차수의 모델을 대상으로 제어기를 설계하고 성능을 비교함으로써 모델 차수가 제어효과에 미치는 영향을 검토하였다.
        4,000원
        15.
        1999.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        대형구조물의 진동감소를 위한 슬라이딩 모드 퍼지 제어기(Sliding Mode Fuzzy Control SMFC)에 대하여 연구하였다 본 제어기에 사용된 퍼지 추론기의 규칙은 비선형 제어기법의 하나인 슬라이딩 모드 제어기를 기반으로 하여 구성되었다 그결과 제어기의 퍼지성은 제어시스템을 시스템 계수의 불확실성과 구조물에 작용되는 외부하중의 불확실성에 대하여 강인한 성질은 갖게 하였으며 제어 규칙의 비선형성으로 인하여 제어기는 선형제어기에 비하여 보다 효율적인 되었다 복잡한 수학 해석에 기반한 종래의 제어기법에 비하여 퍼지 이론에 기반한 본 제어기법은 제어기의 설계절차가 매우 편리하다는 장점을 갖게 된다. 제안된 제어기법의 검증을 위하여 미국 토목학회 산하 구조제어위원회(ASCE Committee on Structural Control)에서 주도한 벤치마크 문제에 대하여 적용시켜 보았다 본 연구의 제어결과를 다른 연구자들에 의하여 발표된 {{{{ ETA _mixed _2\infty }}, optimal polynomial control neural networks control 슬라이딩 모드 제어의 벤치마크 결과와 비교하였으며 그 결과 제안된 제어기법이 구조물의 진동을 매우 효율적으로 감소시키며 제어기의 설계절차가 쉽고 편리함을 확일 할 수 있었다.
        4,300원
        16.
        1995.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 그라우팅공법을 적용하여 진동원으로부터 전파되어 나가는 지반진동을 감소시키기 위한 연구를 수행하였다. 지반의 진동전파모델을 만들기 위해 직접구성에 의한 경계요소법이 사용되었고, 그라우팅층이 진동원의 바로 밑에 있는 것이 가장 진동감쇠효과가 좋으며 그라우팅층의 두께 및 폭이 일정값 이상이 될 필요가 없는 것으로 파악되었다.
        4,000원
        17.
        2018.04 서비스 종료(열람 제한)
        In order to simulate the Helmholtz resonator environment, a perforated plate was inserted into a hollow slab to test its vibration performance. The vibration damping ratio was larger in the conventional hollow slab without apertures, however the accelerometer measurement showed a higher vibration reduction effect in the case of the perforated plate.
        18.
        2016.06 KCI 등재 서비스 종료(열람 제한)
        For elevated railway station on which track is connected with superstructure of station, structural vibration level and structure-borne-noise level has exceeded the reference level due to structural characteristics which transmits vibration directly. Therefore, existing elevated railway station is in need of economical and effective vibration reduction method which enable train service without interruption. In this study, structural vibration non-transmissible system which is applied to vibroisolating material for column member is developed to reduce vibration. That system is cut covering material of the column section using water-jet method and is installed with vibroisolating material on cut section. To verify vibration reduction effect and structural performance for structural vibration non-transmissible system, impact hammer test and cyclic lateral load test are performed for 1/4 scale test specimens. It is observed that natural period which means vibration response characteristics is shifted , and damping ratio is increased about 15~30% which means that system is effective to reduce structural vibration through vibration test. Also load-displacement relation and stiffness change rate of the columns are examined, and it is shown that ductility and energy dissipation capacity is increased. From test results, it is found that vibration non-transmissible system which is applied to column member enable to maintains structural function.
        19.
        2015.02 서비스 종료(열람 제한)
        철도 역사의 경우 보다 효율적인 진동 저감 대책 수립을 위해서는 열차-궤도, 궤도-구조물 등의 상호작용 및 진동의 전달 경로에 대한 고려 등이 필요하다. 또한 역사 구조물의 경우도 접속 교량과의 상호작용, 승강장, 지붕 등 부대시설과의 상호작용에 대한 고려도 필요할 수 있다. 그러나 이러한 역사 구조물과 부대시설과의 상호작용이 소음 및 진동에 미치는 영향에 대한 연구는 미미한 실정이다. 이 논문에서는 승강장과 역사 구조물간의 상호작용 분석을 통하여 소음과 진동을 저감시키는 방안에 대한 연구를 수행하였다. 특히 승강장과 역사 구조물간 연결부의 강성 및 감쇠에 대한 조절을 통한 역사 구조물의 진동 저감 가능성을 검토하였다. 진동 저감 성능은 2차원 및 3차원 유한요소 모델을 이용하여 검증하였다.
        20.
        2015.02 서비스 종료(열람 제한)
        일반적으로 선하역사는 구조물 상부에 차량이 주행하여 진동이 역사 구조물로 직접 전달되는 구조로 다른 구조형식보다 역사 내 소음과 진동 수준이 높아 역사 내 근무자 및 이용객들에게 불편함을 초래하고 있다. 선하역사에 대한 효과적인 진동 저감 대책을 수립하기 위해서는 접속 교량 등 인접구조물과 역사 자체 내의 진동 전달 경로를 고려한 정확한 진동 전달 특성에 대한 이해가 필요하다. 이 연구에서는 국내 선하역사의 구조형식에 대한 분류를 기초로 접속 교량과의 접속 형식, 감쇠기 등 제진 및 면진을 위한 진동 저감장치의 배치방법 등의 변화에 따른 진동 저감 성능을 평가하고 보다 효율적으로 선하역사의 진동을 저감할 수 있는 방향을 제시하였다. 진동 전달 특성 및 저감 성능 평가는 수치해석 및 현장실험을 통하여 수행하였다. 현장실험은 금곡역사를 대상으로 열차의 통과 및 정차에 따른 가속도 측정을 통하여 수행하였다. 수치해석은 상용프로그램인 ABAQUS를 이용하여 수행하였다.
        1 2