검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 37

        21.
        2011.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The building for the Sutra appeared as the Sutra-belief became popular in the early years of the Koryo Dynasty. According to the written documents, there were two types of apparatus to keep sutras, one by fixing the cabinet to the wall and the other by rotating the cabinet at the center of the hall. There are no remains. Recently, at the excavation of the site of the Yeongguk Temple (寧國寺) in the Chungcheong Prevince (영동군), a building which was presumed as the Sutra Hall was recovered at the side of the Main Hall. At the center of the building, of 6meters width and 6meters depth, there was a large stone which had a round trace which was presumed to supporting the rotating sutra-case cabinet. By examining the concerned situations, this building was concluded as the Sutra Hall of the temple. The Yeongguk Temple had a close relationship with the royal household. Budddhist monk Gwangji, son of the 16th King Yejong was lived at the Temple. the tomb of King's advisory priest Wongak was also erected at the Temple. Two monks were well known as the defender of the Sutra. The Sutra Hall of the Yeongguk Temple regarded as a significant example which showed us how the archtectural aspect of the Sutra Hall was shaped in the Koryo Dynasty. It could be said that revealing the architectural aspect of the Stura Hall will help revealing the Buddhist architecture of the Koryo Dynsty which is veiled in many field.
        4,800원
        22.
        2008.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 원자력발전소에 설치되는 캐비닛형 전기기기의 동적 진동시험 자료를 이용하여 캐비닛의 지진응답을 예측할 수 있는 기법을 제안하였다. 제안된 기법은 1) 절점질량 이상화 모델에 기반한 등가 지진하중 산정, 2) 진동시험자료에 기반한 캐비닛 구조의 입출력 상태방정식 규명, 3) 산정된 등가지진하중과 규명된 입출력 상태방정식을 사용한 지진응답산정의 과정으로 구성된다. 제안된 기법은 유한요소기법(FEM) 모델 개선(Model Updating)에 기반한 지진응답예측기법에 비하여 모델링 오차가 개입 되지 않는 장점을 가진다. 캐비넷 구조를 이상화한 2차원 프레임 모델과 3차원 상세 모델에 대한 수치검증을 통하여 제안된 기법이 지진응답을 매우 정확하게 예측을 함을 관찰하였고, 측정 노이즈에 대해서도 강인함을 관찰하였다. 추후연구로 실험검증이 요구된다.
        4,000원
        23.
        2005.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 원전내부의 내진범주 1급 계전기를 포함하고 있는 캐비닛 구조물의 최적내진보강에 대한 연구를 수행하였다. 지진시 계전기는 구조적인 파괴보다는 떨림에 의한 기능적 파괴가 발생한다. 이를 방지하기 위해서는 캐비닛구조물의 응답을 적정 수준이하로 감소시켜야 하므로 다양한 감쇠보강의 설치패턴에 따라 최적의 감쇠계수를 {\mu}-GA(micro-Genetic Algorithm)기법을 이용하여 산정하였다. 대상캐비닛 구조물은 해석의 정확도와 계산의 효율성을 만족시키기 위해 이용한 프레임구조로 모델링되었다. 구조물의 응답은 감쇠기의 비선형거동을 고려한 비선형 시간이력해석에 의해 얻어진 가속도응답스펙트럼으로 나타내었다. 목적함수는 구조물의 해석에서 얻어진 응답스펙트럼의 최대값과 목표 포괄기기내진력 스펙트럼 (GERS; General Equipment Ruggedness Spectra)의 최대응답비를 기초로 작성되었다. 해석결과 적절한 보강패턴을 선정한 경우 좋은 적합도의 향상을 보였으며 특히 감쇠지수의 값이 작은 경우 적합도의 개선효과가 뛰어났다.??
        4,000원
        24.
        2003.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 오래된 원자력발전소의 내진검증과 관련한 USI A-46 문제의 해결에 사용될 수 있는 캐비닛의 내진보강방안에 대해 연구하였다. 캐비닛 구조물의 동적거동특성을 파악하기 위하여 3종류의 모델링을 수행하였고 그 결과를 비교하였다. 또한 ICRS(In Cabinet Reponse Spectrum)의 저감을 위하여 1) 보강프레임, 2)감쇠기 설치, 3) 동조질량감쇠기 등 세 가지 내진보강방안에 대하여 구조물의 응답을 산정하였다. 해석결과, 가새보강 및 감쇠기를 설치하는 보강방법에서는 보강전의 구조물보다 큰 ICRS가 얻어지는 경우가 발생해 보강시 많은 주의가 요구된다. 동조질량감쇠기의 사용은 좋은 제진효과를 보였으나 실구조물과 정확한 진동특성을 반영한 모델의 작성이 중요한 것으로 판단되었다.
        4,000원
        26.
        2000.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        합리적인 기기의 활률론적 지진위험도 평가를 위해서는 모델의 동특성에 대한 보다 현실적인 정보가 제공되어야 한다. 이 연구에서는 심한 비선형 동적 거동을 보일 것으로 예상되는 철제 전기 캐비넷의 동특성 시험결과 및 분석 절차를 제시하였다. 특히, 이 연구에서는 가진 강도의 크기에 따른 동특성의 비선형 집중분석하고, 그 비선형성의 원인을 고찰하였다. 시험 결과 및 이 논문에 제시된 분석 절차를 이용하여 시험체의 동특성이 효과적으로 도출될 수 있으며, 대상 시험체는 가진 강도에 따라 심한 비선형 거동을 함을 입증하였다. 비선형성의 원인은 일반적인 재료 비선형이라기 보다는 각 부품들의 마찰력과 기하학적인 비선형성에 기인함을 발견하였다. 또한, 캐비넷 형식의 기긱에 대한 합리적인 내진안전성 평가를 위해서는 각 방향별로 서로 다른 감쇠값을 적용할 것을 추천하였다. 또한, 캐비넷 형식의 기기에 대한 합리적인 내진안전성 평가를 위해서는 각 방향별로 서로 다른 감쇠값을 적용할 것을 추천하였다.
        4,000원
        27.
        1993.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        원자력발전소중 안전과 관련된 구조물은 지진의 가능성에 대비하여 그의 구조적 안전성과 가용성이 검중되어야 한다. 본 논문은 원자력발전소 보호시스댐 캐비넷올 예롤 들어 그에 대한 내진검증 방법올 보였다. 캐비넷의 유한요소모델을 작성하여 통특성올 구하였고 그 모우드값을 입력지진스펙트럼과 비교한 결과 구조물의 1 차모우드가 입력스펙트럼의 야앓와 일치함으로써 셜계변경의 필요성이 대두되었다. 이 peak 값을 피하기 위하여 캐비넷의 구조를 변경하였고 변경된 구조물에 대하여 웅답스텍트럽해석과 시간 이력해석올 수행하여 구조적 건전성과 가용성올 보임으로써 설계변경된 캐비넷의 내진검증을 확인하였 다
        4,000원
        28.
        2019.10 서비스 종료(열람 제한)
        사회 인프라 시설물 중 발전 플랜트 시설물에 있어 외부 하중 유입 즉, 지진하중 등에 의한 구조물의 구조 건전성은 보장 되어야 하며, 구조물 내부에서 운용되는 전기기기와 같은 비구조요소의 기능적 안전성 또한 확보되어야 한다. 이에 따라 플랜트 구조물 및 내부 기기의 지진 안전성에 관한 연구가 활발히 수행되고 있으나 미흡한 실정이다. 본 연구에서는 지진동에 의한 구조적 및 기능적 건전성이 확보되어야 하는 전기기기 캐비닛 구조물을 대상으로 3방향 역학적 계산이 가능한 유한요소를 이용하여 상세하게 모델링하였으며, 지진 해석의 방법론으로 응답스펙트럼해석과 시간이력해석을 진행하였다. 또한, 두 해석법을 통해 도출된 전기기기 캐비닛의 응답수준을 파악하고 그 값을 비교하여 내부 기기 등에 대한 내진해석 방법론을 제시하고자 하였다.
        29.
        2019.04 서비스 종료(열람 제한)
        Occurring economic loss of economics by the earthquake, such as Gyeongju and Pohang in Korea, interest in seismic stability of facilities is increasing. Electrical Cabinet Structure in Power Plant should be prepared for malfunctions and its structural safety should be ensured as well an earthquake event. The purpose of this investigation is to increase the seismic stability of the cabinet. Through finite elements analysis, dynamic characteristics of the cabinet were identified herein, and time history analysis was performed by converting the design response spectra. In order to improve safety against earthquakes, a variable analysis was conducted to utilize steel dampers for seismic retrofit of the cabinet, and time history analysis results compared with the response of basic and seismic retrofitted cabinets.
        30.
        2019.04 서비스 종료(열람 제한)
        In this case study, seismic category I class electrical equipment in NPP was manufactured and a modal testing was performed using an impact hammer to measure the dynamic characteristics. In the case of electrical cabinets, various safety related components are mounted in the internal frame. Therefore, FEM model that appropriately reflects the local mode is required. To reflect both global and local mode to FEM model, modal testing should be carried out. For implementing the global mode, accelerometers were installed at twenty-eight points of the outline plate edge, and responses for local mode were measured at seven crucial points and compared those results.
        31.
        2019.04 서비스 종료(열람 제한)
        An approach is presented for evaluating the vulnerability of electric cabinet in nuclear power plants. The method is based on the lognormal approach, including the maximum likelihood estimation and linear regression to establish the fragility curves. These procedures are applied for a cabinet considering various boundary conditions, which are expressed by restrained and anchored models at the base. The cabinet models have been built and verified by using the system identification technique. The results show that the fragility curves obtained for the anchored model are found to be closer to each other, compared to the fragility curves for the restrained model.
        32.
        2019.04 서비스 종료(열람 제한)
        Deterministic seismic analysis of cabinet facility does not reflect the real behavior of the system with the uncertainties of material parameters. This paper investigates the effects of uncertain properties in the context of random field theory for the stochastic dynamic response of cabinet. The influences of different decomposition methods (i.e. Cholesky, Eigen, and modified Cholesky) with various correlation lengths of the spatial material distribution are explored. The responses are compared to the case where no variation is applied in the properties of the model.
        33.
        2018.10 서비스 종료(열람 제한)
        In order to analyze the dynamic characteristics and seismic performance of electrical cabinet affected the earthquake, a preliminary study should be carry on to find the natural frequency of that, and it can be known that through shaking table test and finite element analysis. The purpose of this study is to developing regarding the numerical model by using finite element method for the natural frequency of electrical cabinet be influenced by earthquake and to verify its reliability in comparison with experimental data through shaking table test in the future.
        34.
        2018.10 서비스 종료(열람 제한)
        The seismic performance evaluation for the electrical cabinets is conducted by the shaking table test or numerical analysis. When performing the seismic evaluation by the numerical analysis, it usually assumes that the electrical cabinets are rigidly anchored to the floor. This assumption may not be valid depending on how the cabinets are anchored. In particular, if a cabinet is anchored with bolts, a local plastic deformation of the base plate of the cabinet may cause rocking. Therefore, in this study, the shaking table test was performed to analyze the rocking effect of the electrical cabinet in an experimental method.
        35.
        2017.12 KCI 등재 서비스 종료(열람 제한)
        일본 외무성과 시마네현 다케시마 문제연구회는 1905년 각의결정과 이에 따른 후속 하위행정법령으로서 시마네현 고시 제40호 등은 일본이 근대법제의 방식으로 다케시마 영토획득을 표현한 것이라고 주장한다. 하지만 1905년 각의결정 등은 국제법을 위반한 조치였다. 우선 1904년 량코섬 영토편입 및 대하원은 명확하게 독도가 일본보다는 대한제국으로부터 가깝다는 서술을 하고 있고, 1905년 각의결정 또한 독도를 타국이 점령했다고 할 만한 형적이 없다고 하여 일본정부는 타국으로서 대한제국이 이해관계를 가질 수 있음을 인식하고 있었다. 그럼에도 이를 대한제국에 확인하지 않은 것은 일본 정부가 독도를 자의적으로 무주지로 판단한 것이며 국제법을 위반한 것이다. 둘째, 1900년 대한제국 칙령 제41호가 공포되어 관보에 게재된 이후 일본이 1905년 각의결정을 하기까지 기간은 대한제국이 행정편제를 통해 명확화한 영토에 대해 실효적인 지배를 확립하기 위한 ‘합리적으로 충분한 기간’이 경과했다고 볼 수 없다. 결국 대한제국이 칙령 제41호를 통해 타국이 독도를 선점하는 것을 합리적으로 충분한 기간 동안 잠정적으로 금지하는 불완전 권원을 보유하고 있었음에도 일본은 이를 침해한 것이다. 셋째, 1904년 량코 섬 영토편입 및 대하원은 독도가 일본의 영토 오키 열도에서 대한제국의 본토인 강원도와 함경도로 왕복하기 위한 항로에서 대한제국과 긴밀한 관계에 있음을 밝히고 있다. 이는 독도가 일본이 아닌 대한제국의 판도에 속해 있으며 울릉도와 독도가 하나의 영향권 내에 있다는 인식을 표현한 것이다. 넷째, 1905년 각의결정은 1904년 량코섬 영토편입 및 대하원의 독도가 대한제국의 울릉도에서 더 가깝다는 서술을 의도적으로 배제하고 있다. 이는 독도가 일본의 오키 섬으로부터의 거리보다 대한제국의 영토에 더 가깝다는 사실을 은폐한 것이다. 이는 근대 이전 영토획득의 근거로 인정되었던 지리적 근접성의 원칙을 의식하여 이 원칙이 독도에 적용되지 않도록 의도한 것이다. 다섯째, 1905년 각의결정과 1904년 량코 섬 영토편입 및 대하원은 독도를 자국의 영토로 편입하려는 것이 대한제국에 공식적으로 알려지는 경우 대한제국의 이의제기로 인해 실패할 것에 대한 우려가 있음을 명확하게 인식하고 있었다. 이러한 이유로 일본정부는 대한제국에 알려질 가능성이 있는 일본의 근대법제로서 황제의 칙령이 아닌 하위의 각의결정의 형식으로 독도를 편입하여 관보게재 부담을 회피한 것이다. 그리고 시마네 현의 고시를 통해 독도를 대상으로 하는 행정조치를 할 수 있는 국내법적 근거만을 마련한 것이다.
        36.
        2014.12 KCI 등재 서비스 종료(열람 제한)
        이 논문에서는 메이지시기 울릉도·독도에 대한 일본 측의 인식 변화를 고려하면서 1905 년 초에 일본 정부가 시행한 독도 편입 조치의 의미를 검토했다. 각의 결정 당시 일본 중앙정부는 독도를 더 이상 ‘마츠시마’나 ‘다케시마’라고 부르지 않았다. 일본 정부는 나카이 요자부로가 제출한 ‘량코도 영토 편입 및 대하원’에서 사용했던 ‘량코도’나 전통적 명칭인 ‘마츠시마’ 또는 새로 취득한 무주지에 적당한 제3의 명칭이 아니 라, 굳이 역사적으로 많은 혼동을 불러일으켰던 ‘다케시마’라는 명칭을 붙였다. 독도에 대해 ‘다케시마(竹島)’라는 명칭을 붙임으로써 일본 정부는 울릉도와 독도를 연결시켜 인식해온 역사를 근본적으로 부정할 수 없었다는 것을 역설적으로 보여주었다. 일본 정부는 메이지시기에 감행한 도서(島嶼) 편입의 절차를 독도에 그대로 적용했다. 새로 섬을 편입한 후 소관 지방관청이 고시를 하는 것도 그 절차의 일부였다. 지방관청의 고시는 중앙정부(각의결정)→지방관청(고시)→민간(대여)으로 연결되는 일련의 흐름 안에서 파악해야 한다. 즉 고시는 대외적인 조치가 아니라 전적으로 국내용 조치였던 것이며, ‘시마 네 현 고시 제40호’도 예외가 아니었다. 울릉도와 독도를 둘러싸고 2백년 이상 갈등이 있었음에도 불구하고 일본정부는 한국정부에 대해 아무런 통고 조치를 취하지 않음으로써, 편입 조치의 일방성을 웅변하고 있는 셈이다.
        37.
        2011.05 KCI 등재 서비스 종료(열람 제한)
        In the TV manufacturing industry, a demand for chic design of TVs is increasing. As a reult of this trend in TV design, more curved surfaces in a TV cabinet are introduced, which enforces the use of fixers to combine a front cabinet with a TV main body. In this paper, we introduce a robot system for attaching various types of fixers to a TV cabinet. The developed system consists of three main blocks. The first one is the dispensing block, in which transferred cabinet is centered and UV adhesives are dispensed on the cabinet. The second one is the fixer attaching block, in which a cabinet is centered again and fixers are attached to pre-determined places on a cabinet by a robot with several end effectors. The last one is the UV hardening block, in which very strong ultraviolet rays are applied to the cabinet for attaching fixers tightly to the cabinet. The developed system is successfully adopted in a TV manufacturing process.