The PCHE(Printed Circuit Heat Exchanger)-type heat exchanger, which was fabricated by etching and diffusion bonding, was used to hydrogen station, VHTR(Very High Temperature Reactor), SMR and so on. The hydrogen station equipped with PCHE-type heat exchanger is necessary to inject the hydrogen gas into facilities, for instance, such as HFCV(Hydrogen Fuel Cell Vehicle) and power systems. The purpose of this study is to investigate the thermal characteristics of thin plate of PCHE depending on constraint conditions through numerical analysis. As the results, it showed that thermal stress of thin plate, which was not performed diffusion bonding at all, was larger than that, which was performed perfect diffusion bonding, and its maximum difference was about 3 times. Further it was confirmed that the thermal characteristics of thin plate could be obtained by investigating the heat flux.
The research aimed to develop a high-efficiency plate-type heat exchanger for exhaust gas using computational fluid dynamics (CFD) thermal analysis based on the plate shape, and to identify the optimal shape. Following this, a water/air plate heat exchanger was manufactured, and its characteristics were studied experimentally. As the Re number increases on the gas (or air) side, the heat transfer rate increases significantly, whereas an increase in the Re number on the water side leads to a smaller increase in heat transfer. This is attributed to the larger convective heat resistance on the gas side, causing a substantial reduction in gas-side heat resistance as gas velocity increases, resulting in a considerable overall reduction in heat resistance. The fluid flow pressure drop showed similar results between the CFD calculations and experimental outcomes.
The heat transfer characteristics of double-pipe spiral heat exchanger were investigated by various curvature sizes, experimentally. The three different sizes of heat exchanger were made and tested with water as a working fluid to analyze the heat transfer characteristics. The heat transfer rates, overall heat transfer coefficient and pressure drop were analyzed with various heat exchanger sizes (i.e., curvature ratios). As result, the heat transfer rate increased with increasing the size of the heat exchanger as the flow rate increased due to increasing the area size of heat transfer. However, the overall heat transfer coefficient and pressure drop increased with decreasing the heat exchanger size (i.e., increased curvature ratio) due to the enhanced centrifugal force and inertia.
The shell & tube-type heat exchanger has been frequently used because it shows simple structure, easy manufacturing and wide operation conditions among many heat exchangers. This study aims to investigate the characteristics for thermal flow of coolant and the possibility of damage for tube equipped with shell due to thermal stress. For these purposes, The thermal flow of coolant in tube was simulated using ANSYS-CFX program and thus the behaviors of coolant were evaluated with standard k-ε turbulence model. As the results, as the flow rate of coolant in tube was increased, the mean relative pressure was also increased with quadratic curve, however, as the surface temperature of tube was increased, mean temperature difference was linearly increased. Finally it showed that the damage of tube could be predicted, that is, which tube was the most weak due to thermal stress.
Test of the operating characteristics and energy saving performance of a container cooling system that reduces the operating energy of a refrigeration system using a loop thermosyphon heat exchanger that removes heat by temperature difference between outdoor and indoor was performed. As a result of the experiments, when the loop thermosyphon and the refrigeration system were operated simultaneously, the refrigeration system operated intermittently by reducing the heat load. As the temperature difference between indoor and outdoor increased, the operating time of the refrigeration system decreased and the energy efficiency rate increased. Energy efficiency rate showed a tendency to increase with increasing temperature difference, and the predicted correlation of energy efficiency rate using the performance of the loop thermosyphon heat exchanger and the refrigeration system was relatively consistent with the experimental value.
Climatologists have warned rapid climate change of the earth and it will cause a big disaster worldwide. the rapid climate change is mostly due to emission of greenhouse gases. To reduce greenhouse gases, many countries have prepared protocols, agreements, and treaties. IMO(International Maritime Organization) have established the protocol to decrease ship’s greenhouse gases emission and they consider the nuclear power source is an option to replace fossils fuels. Our study focused on elemental technologies related to a nuclear powered ship and, the passive residual heat removal system(PRHRS) is one of topics in our study. As the mandatory of the post Fukushima accident, PRHRS for a nuclear powered ship has been studied. We invented the new concepts of PRHRS which is optimized to a nuclear powered ship. The numerical analysis results indicated that the system is very reasonable. Based on the numerical analysis, an experiential loop was set and we preliminary tested the performance of the system under the reduced scale. The experimental results came with the numerical analysis results well.
In this study, the cooling performance change according to the arrangement of the fin-tube heat exchanger using a single tube and the cooling performance change according to the air flow rate were studied. The arrangement of basic heat exchanger was set to 4 columns and 4 rows, and the performance change was studied while changing the columns and rows. In addition, the performance change was investigated by changing the air flow rate of the basic heat exchanger.
A heat exchanger refers to a pressure vessel that indirectly exchanges heat between low-temperature/ high-temperature fluids with a solid wall interposed therebetween, and a shell-and-tube cylindrical heat exchanger is generally applied. The shell-and-tube cylindrical heat exchanger is widely used in ships and there is a problem in that the welding area is narrow and welding defects occur a lot due to high-level welding. In particular, in the case of a ship heat exchanger, if a problem occurs in the welding part during operation, the possibility of a safety accident is high, and repair is not easy. In this study, to solve this problem, the GTAW(Gas Tungsten Arc Welding) method was applied to secure the optimum conditions for pipe welding of STS304 material with a thickness of 5.5mm and to conduct a test. Afterwards, in accordance with the ASME rules, welding performance was verified through cross-sectional observation of welds, mechanical property tests, (tensile strength, bending strength, cryogenic impact strength) and non-destructive testing(PT, RT).
This study presents a numerical modeling and a transient simulation of a desiccant coated heat exchanger (DCHE) that is employed for dehumidification in buildings. DCHE is fabricated by coating type RD silica gel on the fin surfaces of a fin tube heat exchanger. The latent cooling load, which is 25 to 45% of the total cooling load in most weather conditions is removed by adsorption of vapor using DCHE. The saturated adsorbent is then regenerated by using either low-temperature waste heat from industry and/or renewable energy such as solar energy and geothermal energy. A mathematical model is established and a transient simulation has been carried out so as to analyze its performance in terms of average humidity difference (AHD), moisture removal capacity (MRC), latent cooling capacity(QL), and COP. Comparison between the simulation results and the experimental data was carried out and showed good agreement and a similar trend with a maximum discrepancy of 5%. Key results revealed that MRC, AHD, QL, and COP are largely affected by both air dry-bulb temperate and air wet-bulb temperature while they are less affected by the frontal air velocity. Furthermore AHD, MRC and QL are largely improved by hot-water temperature while COP decreases as hot-water temperature increases due to high regeneration energy consumption.
This paper considers the influence of internal heat exchanger and capillary tube on the efficiency of small refrigeration system using eco-friendly refrigerants such as R290, R600a, R1270, and R717. A refrigeration system using such internal heat exchanger and capillary tube may improve performance, but may degrade performance. Therefore, this paper used a mathematical model in a normal state to understand performance characteristics as to what change occurs when internal heat exchanger and capillary tube are attached to eco-friendly refrigerant based on R134a. In addition, the effects of operating conditions such as refrigerant flow rate, evaporation temperature, condensation temperature, subcooling degree internal heat exchanger length and capillary tube length were analyzed. The result showed that the evaporation temperature, condensation temperature, subcooling degree, internal heat exchanger length and capillary tube length had an effect on the refrigeration capacity and compression power. Therefore, it is necessary to design a refrigeration cycle using an eco-friendly refrigerant by grasping these effects in detail.
본 연구에서는 단면설계 및 열 교환 장치 위치 변경을 통해 온실의 구조 변경을 진행하였으며, 선행연구를 통해 개발된 모델을 근간으로 하여 개선 여부에 따른 온실 내부 환경을 예측하였다. 단면형상과 열 교환 장치의 개선 후 유속 변화에 따른 시뮬레이션 분석을 진행하였으며, 이 때 온도와 균일도는 각각 평균 0.65°C, 0.75%p 상승함을 확인하였다. 해석대상 온실과 같은 소규모 온실의 경우 방열관의 난방성능 개선보다 FCU에 의해 형성되는 공기 유동이 균일한 환경 조성에 더 큰 영향을 미치는 것으로 판단된다. 개선 전 ‧ 후 온실에 환기시스템 적용 시 공기 유동 특성 분석을 위해 시뮬레이션 분석을 진행하였다. 공기 유동과 공기령은 유사한 분포를 보였으며, 개선 후 온실의 공기령이 개선 전 온실 대비 18초 낮게 나타났다. 개선 전 ‧ 후 온실 시뮬레이션 분석 결과 전체적으로 개선된 온실에서의 평균온도 및 온도 균일도 상승, 최대편차 감소 등 내부 환경의 균일성이 향상됨을 확인하였다. 선행연구로 개발 된 모델은 형상 변경, 열 교환 장치 위치 변경 등에 따라 변화하는 온실 내부 환경을 예측할 수 있음을 확인하였으며, 온실 설계, 온실 내 난방시스템 설계 등의 분야에 적용 가능할 것으로 판단된다.
Experiments were conducted to evaluate the performance factors such as type of working fluid, flow direction, arrangement and stage of loop thermosyphon heat exchanger for ESS battery container cooling. Pentane showed slightly better performance of the heat exchanger than R-134a as a working fluid. Driving the fan in the suction direction showed improved performance compared to the blowing direction. The two-stage heat exchanger increased the heat transfer rate by more than 30% at the same temperature difference compared to the single-stage heat exchanger. Also, the counterflow flow showed better performance than the parallel flow in the two-stage heat exchanger.
The purpose of this study is to experimentally figure out thermal performances of a newly developed wavy patterned heat plates(first heat plates) which are known to have better thermal performances than the conventional heat plates. Three types of products were made with high and low chevron angled plates. The test results show that overall heat transfer coefficients and pressure drops increased with flow rates and chevron angles just like other studies. Another purpose of this study is to find a way to reduce pressure drops while maintaining or even improving the heat transfer characteristics of the first heat plates. Research on optimization of the distribution area on the heat plate to achieve the even fluid distribution was conducted, and then the second heat plates were developed to reflect the research results. Another new three types of products with the second heat plates were manufactured and tested, too. The test results of the second heat plates were compared with those of the first heat plates to find out how the distribution area contributed to the thermal performances of the heat plates. The comparison showed that distribution area optimization could affect thermal performances of the high chevron angled plate positively, but the low chevron angled plate had little effect from the optimization. This is considered to be because the low chevron angled plate itself has a characteristic that the pressure drop is small.
Experiments were conducted on the operating characteristics and performance of various types of working fluid, filling amount and heat flow rate of a loop thermosyphon for cooling ESS battery container. As results of performance test on various working fluids, HFE-7100 and R-134a as a working fluids showed unstable operating and low performance due to vapor pressure drop, and performance was improved by increasing the number of vapor lines for reducing a pressure drop. In this study, n-pentane was more stable and showed better thermal performance among various working fluids.
A gasketed plate heat exchanger(GPHE) requires a much smaller installation space than a shell & tube heat exchanger because of its compact and good thermal performances. However, GPHEs have a disadvantage of being relatively vulnerable to high temperature and pressure due to rubber gaskets. To overcome a GPHEs’ disadvantage, Welded Block type Plate Heat Exchangers(WBPHE) have been developed. The flow pattern and heat transfer principle of WBPHE are very similar to GPHEs, so they are very compact and can be applied to high temperature and pressure. In this study, the structure and characteristics of WBPHE are briefly introduced, and its thermal performances were conducted experimentally using hot and cold water in the Reynolds number’s range from 5,500 to 10,000. Test results were compared with the experimental correlations of other researchers, which shows that significant deviations were noticed in the heat transfer coefficient predictions with a deviation range from 31% to 85%. The previous friction factor correlations also predicted the current results with big errors from 25% to 45%. These deviations are expected to be due to different chevron angles between previous studies and the current study, and also the end-plate effect is expected to be one of the potential causes that led to these deviations.
In order to enhance the utilization of underground heat including underground water, the comparison between the existing high density polyethylene underground heat exchanger and the newly developed metal heat exchanger was conducted to suggest the potential use of geothermal energy corresponding to the geological characteristics of Jeju Island. When the acquired heat of the underground loop system test condition of the KS B 8292 water-water geothermal heat pump unit was compared by installing heat exchanger of HDPE material and the heat exchanger of STS material under the same bore hole condition, the total heat area of the heat exchanger of STS material was about 15% less than HDPE, but the acquired heat was estimated to be about 4 times or more.