Occurrence of process environment changes, such as influent load variances and process condition changes, can reduce treatment efficiency, increasing effluent water quality. In order to prevent exceeding effluent standards, it is necessary to manage effluent water quality based on process operation data including influent and process condition before exceeding occur. Accordingly, the development of the effluent water quality prediction system and the application of technology to wastewater treatment processes are getting attention. Therefore, in this study, through the multi-channel measuring instruments in the bio-reactor and smart multi-item water quality sensors (location in bio-reactor influent/effluent) were installed in The Seonam water recycling center #2 treatment plant series 3, it was collected water quality data centering around COD, T-N. Using the collected data, the artificial intelligence-based effluent quality prediction model was developed, and relative errors were compared with effluent TMS measurement data. Through relative error comparison, the applicability of the artificial intelligence-based effluent water quality prediction model in wastewater treatment process was reviewed.
The spectrum of this study was research on the closed hydroponic cultivation of netted melons (Cucumis melo L.) using coir substrate, analyzing the impact of this cultivation method on melon yield, fruit quality, and the efficiency of water and nutrient usage. The experimental results showed that the average fruit weight of the melons grown in a closed system was 71.4 g higher than that of the open system, and the fruit width was on average 0.2 cm larger, showing a statistically significant difference. However, there was no difference in the average sugar content of the fruit flesh and height. Although there is no substantial commercial difference, it is conjectured that the change in the macronutrients ratio in the irrigation has played a role in the statistically significant increase in fruit weight, which is attributed to changes in the crops' nutrient uptake concentrations. This necessitates further research for a more comprehensive understanding. In terms of the productivity of irrigation required to produce the fruit, applying the closed system resulted in an increase of 7.6 kg/ton compared to the open system, saving 31.6% of water resources. Additionally, in terms of nutrients, cultivating in a closed system allowed for savings of approximately 59, 25, 55, 83, 76, and 87% of N, P, K, Ca, Mg, and S, respectively, throughout the entire cultivation period. As the drainage was reused, the ratios of NO3 - and Ca2+ increased up to a maximum of 9.6 and 9.1%, respectively, while the ratios of other ions gradually decreased. In summary, these results suggest that closed hydroponic cultivation can effectively optimize the use of water and fertilizer while maintaining excellent fruit quality in melon cultivation.
새만금호는 우리나라 최대의 인공호수로 호수의 수질은 갈수록 악화되어 가고 있어 호수의 특성에 맞는 새로운 수질관리 대 책이 필요하다. 이에 새만금호의 국가수질측정망 자료를 이용하여 통계분석 기법에 의한 새만금호의 시공간적 수질특성을 분석하였다. 수질항목간의 상관성에서 수온과 TP는 상관성이 있고, 염분과 TN, 그리고 pH와 COD가 상관성이 높았다. 그 외 항목들 간에는 낮은 상관 성을 나타내어 관련성이 낮았다. 주성분 분석을 이용한 새만금호의 공간적 수질특성을 보면, 크게 4개의 그룹으로 구분되었는데, 담수 영 향구역과 해수 영향구역, 해수와 담수가 혼합되는 중간 수역이 2개 그룹으로 구분되어 각각 다른 수질특성을 나타내었다. 주성분분석을 이용한 시간적 수질특성은 계절적으로 4가지 그룹으로 구분되었다. 그룹Ⅰ은 늦봄과 초여름에 해당되는 5, 6월이고, 그룹 Ⅱ는 계절적으 로 초봄(3, 4월)과 늦가을(11, 12월)에 해당되는 시기로 나타났으며, 그룹 Ⅲ은 낮은 수온에 의한 용존산소의 증가가 나타나는 계절인 겨울 철(1, 2월)의 수질 특성을 보였고, 그룹 Ⅳ는 하계(7, 8, 9, 10월) 성층의 발달로 저층 퇴적물의 높은 인농도와 하계 고수온의 상관성을 가지 는 그룹으로 구분되었다. 이는 새만금호가 인위적으로 조성된 호수로써 상류 만경강과 동진강의 유입 영향을 받는 것과 동시에 새만금 방조제에 설치된 가력과 신시갑문을 통한 외해수 유입의 영향을 받음으로써 수질의 변동요소가 달라진 것으로 평가된다. 새만금호의 목 표수질을 달성하기 위해서는 상류 유역의 오염원 관리 대책과 함께 새만금호의 수질관리 대책을 수립할 필요가 있다.
본 연구에서는 하수 재이용을 위한 역삼투막 공정에서 전처리 정밀여과막(MF) 손상에 대한 누출되는 다양한 수 질변화로써 막 손상 검지 방안을 제시하였다. 이를 위하여 역삼투막 유입수질 적합성 평가지표인 SDI (silt density index)를 3에서 5의 범위 내에서 막 손상 시 검지 감도를 정량화하기 위하여 전처리 분리막이 1에서 3가닥 파단에 따라 SDI는 1.92에 서 6.11까지 증가한 결과를 확인할 수 있었다. 일반적으로 3을 기준으로 역삼투막 유입수질로 설정하였을 때 분리막이 3가닥 까지 파단이 되어야만 막 손상 검지가 가능하다는 것을 의미하며 역삼투막의 오염은 잠재적으로 가속화되어 효율을 저하시 킬 수 있다. 또한 이때 누출되는 입자성과 유기물질에 대하여 0.45 μm 이상의 크기만 걸러주는 입자계수는 입도분포별 막 파 단 개수에 따라 일정한 패턴을 확인할 수 없었으며, TOC 농도는 약 2배의 변화패턴으로써 SDI와의 상관관계로써 TOC가 막 손상 수질지표로써 신뢰성이 높은 것으로 확인되었다. 수질분석결과와 더불어 USEPA에서 제시하는 막 손상 검지 방법 중 압력손실시험과 이를 기반으로 LRVDIT 모델의 적합성 평가를 한 결과 막 손상 또는 역삼투막 공정으로 유입되는 막오염물질 을 신속하게 확인할 수 있는 SDI 및 TOC를 포함한 LRVDIT 모니터링과 UCL 설정을 병행해야 한다.
해양심층수는 수심 200 m보다 깊은 심층(深層)에 위치하고 있어 차가운 온도를 유지하고 있으며, 대장균 및 일반세균 등에 의해서도 오염 되지 않은 깨끗한 해수이다. 해양심층수는 산업적 가치가 높은 재생순환형 자원이기 때문에 이를 상업적으로 이용하기 위한 활동이 활발히 전개되고 있다. 해양심층수를 기존 식육가공품의 염지제 대체제로서, 최적인 해양심층수 처리수를 적용한 시제품을 일반 식육가공품 소세지와 비교하여 안전성과 품질특성, 미네랄 함량차이를 알아보았다. 이를 통하여 해양심층수의 염지액 대체제로서의 가능성을 검토하고 이를 이용하여 제작한 식육가공품의 품질을 검토한 결과, 안전성과 품질특성에서는 일반 식육가공품 소세지와 차이가 없었으나, 미네랄 함량은 해양심층수를 적용한 축산가공품이 더 높았다. 이를 통하여 해양심층수는 소금의 대체제와 청정미네랄로 그 활용도가 높아서 해양심층수를 이용한 새로운 식품시장이 크게 활성화될 것으로 예상된다. 따라서 본 연구에서는 식품공전 규격 검사에 의한 안전성 평가 시험방법을 이용하여 품질검사항목 분석에 의한 품질특성 평가 및 유통기한 경과에 의한 안정성을 검토하고, 시험군과 대조군간의 미네랄 함량 시험을 진행하여 그 함량을 비교, 분석한 결과 후속 연구를 통한 식품, 의약품 및 축산업에 다양하고 차별화된 식육가공품을 제조할 수 있는 가능성이 있다고 판단하였다.
This study was conducted to provide basic data for establishing water pollution prevention for effluent water from soil and stone quarries and downstream river water by investigating waste water and sewage water processing, as well as the state of legislation related to grit chamber installation and water quality analysis. The pH and DO, BOD, T-P, Total coilform of effluent water and stream water showed higher than Ⅲ class but COD and SS, T-N showed less than Ⅲ class. In addition, concentration of BOD and COD, Turbidity were increased following deepened rainfall intensity. And therefore we devise systematic reduction facility and remedy for prevention of water pollution.
Recently, advanced metering infrastructure (AMI) has been recognized as a core technology of smart water grid, and the relevant market is growing constantly. In this study, we developed all-in-one smart water meter of the AMI system, which was installed on the test-bed to verify both effectiveness and field applicability in office building water usage. Developed 15 mm-diameter smart water meter is a magneto-resistive digital meter, and measures flow rate and water quality parameters (temperature, conductivity) simultaneously. As a result of the water usage analysis by installing six smart water meters on various purposes in office building water usage, the water usage in shower room showed the highest values as the 1,870 L/day and 26.6 liter per capita day (LPCD). But, the water usage in laboratory was irregular, depending on the many variables. From the analysis of the water usage based on day of the week, the water usage on Monday showed the highest value, and tended to decrease toward the weekend. According to the PCA results and multivariate statistical approaches, the shower room (Group 3) and 2 floor man’s restroom sink (Group 1-3) have been classified as a separate group, and the others did not show a significant difference in both water use and water quality aspects. From the analysis of water usage measured in this study, the leak or water quality accident did not occur. Consequently, all-in-one smart water meter developed in this study can measure flow rate and water quality parameters (temperature, conductivity) simultaneously with effective field applicability in office building water usage.
The study of water environment system using a multivariate analysis in Changnyeong-Haman weir section has been conducted. The purpose of this study is to establish better understanding related water qualities in the Changnyeong-Haman weir section which can provide useful information. The data were consisted of water quality data and algae data including WT(water temperature), pH, DO, EC, COD, SS, T-N, NH3-N, T-P, PO4-P, Chl-a, TOC, d-silica, t-silica, Cyanobacteria, Diatoms, and Green algae. Statistical analyses used in this study were correlation analysis, principal components, and factor analysis. According to correlation analysis on COD and TOC, it revealed that the each value of correlation coefficient was 0.843. On the other result, a negative correlation was observed between diatoms and d-silica. Furthermore, the results of principal component analysis to the overall water quality were classified into four main factors with contribution rate 81.071%.
Pollution in the fresh water system in urban area has the adverse effect on the amphibians population. Restoration activity of amphibian in the urban stream has been growing in Korea as well as western country. For successful restoration water quality of urban stream should be sufficient for survival and normal development of amphibian. To monitor the biological safety of surface water in the Tancheon basin, the capital area of Korea, a 6-day exposure Bombina orientalis embryo developmental toxicity assay was examined. The toxicity of surface water of Tancheon mainstream were lower than those of tributaries of Tancheon. The survival rate of embryos negatively correlated with total dissolved solid, turbidity and electrical conductivity whereas the developmental abnormality and growth retardation of embryos was positively correlated with total dissolved solid, turbidity and electrical conductivity. An amphibian developmental toxicity assay would be helpful for the selection of point for construction of habitat and reintroduction of amphibian in interrupted urban stream.
이 연구는 환경부 지정 생태 경관보전지역인 왕피천 유역의 저서성 대형무척추동물 군집분석 및 생물학적 수질평가를 실시하기 위한 것으로 2012년 6월에서 9월까지 총 2회에 걸쳐 현장조사를 수행하였다. 조사대상 지점은 왕피천 유역의 핵심 및 완충구역을 중심으로 상류에서 하류에 걸친 총 11개 지점(본류 5개 지점, 지류 6개 지점)에 해당된다. 조사결과 총 5문 7강 15목 74과 155종이 확인되었으며, 분류된 종과 개체수에 대한 군집분석 결과 우점도지수(DI)는 평균 0.22로 낮게 나타났으며, 평균 종다양도지수(H')는 4.24로 매우 높게 분석되었다. 그리고 조사된 섭식기능군을 이용하여 생태경관보전지역 지정 전과 후의 서식지 유형별 유사도를 분석한 결과, 생태경관보전지역 지정 이후에 지류 94.51%, 본류 93.19%의 높은 유사도 지수 값을 보였다. 이러한 결과로 왕피천 유역에 다양한 종과 많은 개체수가 서식하고 있으며, 생태경관보전지역 지정 이후에 하천생태계의 기능적인 면 역시 잘 유지되고 있음을 유추할 수 있었다. 또한 청정한 하천에서 높은 값을 보이는 EPT 지수값 역시 62.9%로 높게 분석되었다. 그리고 저서성 대형무척추동물 생태점수(ESB)와 한국오수생물지수(KSI)를 이용한 연구지역의 환경상태 및 생물학적 수질을 평가한 결과, 저서성 대형무척추동물 생태점수는 평균 208.2로 매우 높게 나타나 '최우선보호수역'으로 판정되었으며, 한국오수생물지수는 평균 0.32로 생물학적 수질등급 'I등급'으로 평가되었다.
운문산 상류 수계의 저서성 대형무척추동물상 조사 및 생물학적 수질평가는 2007년 11월에서 2008년 9월까지 시행되었으며 조사결과 4문 5강 13목 61과 106속 140종이 조사되었다. 전 지점을 종합해 볼 때 날도래목의 네모집날도래 KUa가 우점종이며 지점별 우점도지수(DI)를 살펴보면 2지점이 0.553으로 가장 높았으며 7지점이 0.354로 가장 낮게 나타났다. 다양도지수(H')에서는 7지점이 2.18로 가장 높았으며 2지점이 1.75로 가장 낮게 나타났다. 저서성 대형무척추동물 생태점수(ESB)애서는 4지점과 7지점이 85로 가장 높게 나타나 '최우선보호수역'으로 판정되었으며 5 지점이 51 로 가장 낮게 나타나 '보호수역'으로 판정되었으며 전 지점 모두 오수생물계열에서 '변부수성'을 나타냈다.
본 연구는 1999년 9월부터 2000련 8월까지 1년간 강원도 평창군 소재 평창강 일대의 15개 조사지점을 대상으로 계절별로 저서성 대형무척추동물을 채집, 분류, 동정하고 현지 수질을 생태학적으로 평가한 것이다. 총 4문 4강 10목 31과 77속 109종이 채집되었으며, 조사지점 중 진부면 간평리에서 53종(48.0%)이 채집되어 가장 많은 종들이 출현하였고 마하리와 창동리에서도 각각 51종(46.7%), 50종(45.8%)이 채집되었다. 그러나 수
국내 정수장.수도전.간이상수도등 2000여 곳의 수질을 환경부가 검사한 결과, 지역별로 세균.무기 이온등 몇몇 항목에서 환경기준을 초과한 것이 밝혀졌다. 이중에서 문제가 되고 있는 질산성 질소.암모니아성 질소.불소.염소등의 농도를 임의로 조작한 후, 시중에 유통되고 있는 가정용 정수기 모듈로 정수처리시켰을 때의 효과와 지역별로 문제시되는 항목들을 효과적으로 제거하기 위한 적당한 분리막을 선정하고자 측정 검토하였다. 정수처리하여 얻은 투과수를 일정 온도 하에서 보관하고, 일정 시간마다 세균수를 측정하여 세균수와 온도 및 시간과의 관계를 측정 조사함으로써 막 사용을 좀 더 효율적으로 할 수 있게끔 검토하였다.