검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 6,698

        4901.
        2018.04 서비스 종료(열람 제한)
        In many climatic conditions, there is UV ray, which is called ultraviolet rays, which has the greatest effect on sealing materials. Because UV has high energy, it changes the internal structure of polymer and causes quality deterioration. In addition, temperature, humidity, and rainfall, snowfall, and atmospheric pollutants are also factors to be avoided in maintaining the integrity of the sealant. In this study, we tried to obtain reproducibility by using a composite deterioration test device which can describe the environment of the outside air as a part of the research project to investigate the weather change in the prototype of the structural sealant. The outdoor exposure test result and the composite deterioration test device Correlation analysis. In the future, it will be possible to predict the changes in the physical properties of the structural sealant by applying the composite deterioration test equipment and outdoor exposure test data.
        4902.
        2018.04 서비스 종료(열람 제한)
        The old electric transmission tunnel over thirty years old in northern Seoul is operated with Ttukdo substation as its starting point and 41km-length since March, 1980, and the trend is an icrease in embedded electric power structures over thirty years old beyond sixty kilometers. If the corrosion occur in reinforced concrete structures, it is considered as the important factor among deterioration factors .By examing the seventy-two cases of concrete carbonation and covering depth in order to analyze the concrete carbonation of electric power structures over thirth years old in Gangbuk-gu, this paper atempts to analyze carbonation coefficient, remaning service life, and concrete carbonation of old embedded electric power structures for reference to predict the concrete carbonation progress.
        4903.
        2018.04 서비스 종료(열람 제한)
        Recently, accidents caused by the aging of structures are occurring frequently in the world. As a result, maintenance and accident prevention of structures are required. In this study, for the purpose of addressing these issues to solve these problems, we developed a non - destructive inspection technique using thermal imaging and planned damage detection process. we set up a scenario to detect the invisible excursions, cracks, and internal damage by sensing and analyzing the thermal energy radiated by the stainless steel test piece (STS304) with infrared thermal imaging equipment.
        4904.
        2018.04 서비스 종료(열람 제한)
        The target in the design of base isolated structures is the selection of isolation system properties so that optimal performance is achieved among seismic levels and performance metrics. To withstand very rare ground motions, isolation system are frequently designed with significant strength or damping, and as a result such devices provide reduced isolation effect for more frequent seismic events. To investigate improvements to the design of isolated structures, a lot of research program is performed. Experimental investigations are presented to characterize smart base isolation capable of progressively exhibiting different hysteretic properties at different stages of response. Shear tests are conducted along the ISO standard, including harmonic characterizations tests. These tests included various input intensities, multi-component excitation. Behavior of the new smart base isolation system is compared with that of linear isolation systems with both nonlinear viscous and bilinear hysteretic energy dissipation mechanisms.
        4905.
        2018.04 서비스 종료(열람 제한)
        In this study, we propose a structural modeling method to analyze the seismic behavior characteristics of arched stone bridge. For this purpose, we select the representative model of arched stone bridge, and various arch types are set in consideration of the width and height. Accordingly, this study applies the discrete element method for the modelling of discontinuum structure to analyze the seismic behavior characteristics according to the various arched types.
        4906.
        2018.04 서비스 종료(열람 제한)
        This paper presents the seismic performance of the steel damper under reversed cyclic loading. The U-shaped steel damper used in this study was designed to have energy dissipation zone with an external diameter of 120 mm, a width of 15 mm, and a thickness of 15 mm. The cyclic loading test was carried out using an uniaxial universal testing machine with a capacity of 2,000 kN. The test results indicated that no strength deterioration of the specimen was found as well as the equivalent damping ratio of the specimen was excellent.
        4907.
        2018.04 서비스 종료(열람 제한)
        In this paper, structural behavior of internal and external connection of modular system was evaluated by finite element analysis(FEA). As a result of FEA, results of experiment and analysis were nearly similar to validate analysis model. Parametric analysis will be necessary using this valid analysis model
        4908.
        2018.04 서비스 종료(열람 제한)
        The purpose of this study was to experimentally evaluate seismic performance of connection of modular system. As a result of experiment study, two specimens did not show the strength reduction and brittle fracture at connection until 2% story drift. Thus, requirements for intermediate moment frame(IMF) was satisfied in two specimens.
        4909.
        2018.04 서비스 종료(열람 제한)
        In this study, the explosion resistance on the normal strength concrete and HPFRCC structure members were evaluated. As a result of TNT ignition test, blow out occurred in normal strength concrete structure member, but HPFRCC structure member only cracked slightly. The structure member with 180 MPa HPFRCC has excellent resistance against explosive load. Therefore, HPFRCC is considered to be applicable to national main facilities and major military facilities.
        4910.
        2018.04 서비스 종료(열람 제한)
        Frequent unstable natural disasters worldwide in recent year caused damage to large power plants, high-rise buildings, dams and public facilities, resulting in a growing sense of anxiety among people. This is result in the increase of concern for the safety of residential as well as public infrastructure. Considering this growing concern for the public infrastructure a systematic safety evaluation is require. Thus, in this paper, the fragility of weir structure by considering the scour effect of flood was the focused of study. The weir structure in this study was located in Daegu city; it served as the power and water supply and flood prevention. The study was performed by conducting penetration analysis on the variables of the adjacent ground.
        4911.
        2018.04 서비스 종료(열람 제한)
        Blast-resistant doors are installed to protect human life, precious equipments and materials in the plant and other similar industrial facilities, national important SOC, evacuation facilities and military shelter. In this study structural behavior according to the boundary condition is analyzed. For the simulation the FE program LS-DYNA is used. Anaylsis results will be used to design blast-resistant door in detail.
        4912.
        2018.04 서비스 종료(열람 제한)
        Blast-resistant doors are installed to protect human life, precious equipments and materials in the plant and other similar industrial facilities, national important SOC, evacuation facilities and military shelter. In this study structural type and design consideration for blast-resistant doors are reviewed to design a bullet- and blastproof structures including doors.
        4913.
        2018.04 서비스 종료(열람 제한)
        In this research, new structural design and manufacturing method of atypical irregular UHPC structural members were newly introduced. The atypical irregular UHPC member was optimized to design from the conventional rectangular section and a method of nonuniform formwork system was newly created to manufacture the irregular member. The specimens were evaluated by analysis and the newly designed member was improved in bending performance by 2.6 times compared to conventional rectangular concrete beams.
        4914.
        2018.04 서비스 종료(열람 제한)
        The transition piece of the offshore wind power support structure transmits the load of the tower stably to the support structure on the lower side. The transition piece of the offshore wind power support structure should solve the stress concentration problem in design. In this paper, in order to solve the stress concentration problem occurring at the transition piece of the offshore wind power support structure, the location and the mitigation of the stress concentration have been studied.
        4915.
        2018.04 서비스 종료(열람 제한)
        In the KEPIC-SNG, the domestic technical standard of the SC structure, the condition that the baseplate supporting the reinforcing bars is not bonded to the surface plate is suggested. However, if the baseplate is bonded only to the wingplate, all of the rebar loads generated on the baseplate will be transferred to the wingplate. The wingplate is expected to be conservatively designed in spacing and thickness to support the rebar load. In this study, the finite element analysis was carried out according to bonding conditions between surface plate and baseplate. As a result, it was confirmed that the overall structural strength was increased when the baseplate and the surface plate were bonded. Based on this result, it is possible to propose an economical design for the RC-SC connection such as increasing the wingplate spacing.
        4916.
        2018.04 서비스 종료(열람 제한)
        Recently, the frequency of natural disasters in Korea is increasing due to the influence of global climate change, and the importance of quick and accurate monitoring and corresponding response is frequently and strongly stressed in terms of disaster management. In this regard, this study describes a development of realtime safety evaluation system (RSEE) which enables to carryout real-time measurement and safety evaluation of some important SOC water infrastructures (dams, weirs, cut slopes, retaining walls, levees and bridges) installed along the nation registered large scale rivers.
        4917.
        2018.04 서비스 종료(열람 제한)
        The Integrated Water Infrastructures Safety Management Platform(WINS+) provides safety information of water infrastructures such as dams, weirs, bridges, cut slopes, retaining walls and levees designated as the first class infrastructures to be maintained according to the nations’s safety law. The WINS+ is incorporated with a computerized Standard Operating Procedure (SOP) system that provides crisis warning level (green/blue/yellow/orange/red) to central and individual disaster response managers of waterside structures. Thus it is expected that by using the WINS+ we may strengthen disaster responsiveness and reduce the time for recovery and response at emergency.
        4918.
        2018.04 서비스 종료(열람 제한)
        In the case of the port mooring facility, jetties with piles are mainly applied in soft ground conditions. In the three-dimensional modeling for the structural analysis of jetties with piles, the boundary conditions between the pile and the ground are universally applied to the Approximate depth of pile supported method and Elastic subgrade reaction spring method. In this study, p-y curve data for the pile ground condition was generated using the LPILE program, and then the nonlinear spring considering the p-y curve as the pile and ground boundary condition was input and analyzed in the 3D modeling of jetties with piles using the MIDAS civil And the necessity of applying the Nonlinear subgrade reaction spring method by comparison with the result and the analysis result according to the existing analysis method is suggested.
        4919.
        2018.04 서비스 종료(열람 제한)
        The extent damages of concrete structures due to fire occurrence are evaluated. The evaluation of fire safety is evaluated by using the inspection, non-destruction test, fracture test(concrete SEM analysis, concrete heat analysis, rebar fracture test. The criteria for determining the safety of concrete structures are presented using evaluation results.
        4920.
        2018.04 서비스 종료(열람 제한)
        In this study, an experimental study of Impulse Thermography was carried out on a concrete specimen with in-placed artificial defects at different depths and dimensions. Then, all the data were processed by Pulse Phase Thermography technique by performing Fast Fourier Transformation. The results were compared with the absolute contrast method.