검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 34

        3.
        2022.10 구독 인증기관·개인회원 무료
        Dose-rate monitoring instruments are indispensable to protect workers from the potential risk of radiation exposure, and are commonly calibrated in terms of the ambient dose equivalent (H*(10)), an operational quantity that is widely used for area monitoring. Plastic scintillation detectors are ideal equipment for dosimetry because of their advantages of low cost and tissue equivalence. However, these detectors are rarely used owing to the characteristics caused by low-atomic-number elements, such as low interaction coefficients and poor gamma-ray spectroscopy. In this study, we calculated the G(E) function to utilize a plastic scintillation detector in spectroscopic dosimetry applications. Numerous spectra with arbitrary energies of gamma rays and their H*(10) were calculated using Monte Carlo simulations and were used to obtain the G(E) function. We acquired three different types of G(E) functions using the least-square and first-order methods. The performances of the G(E) functions were compared with one another, including the conventional total counting method. The performance was evaluated using 133Ba, 137Cs, 152Eu, and 60Co radioisotopes in terms of the mean absolute percentage error between the predicted and true H*(10) values. In addition, we confirmed that the dose-rate prediction errors were within acceptable uncertainty ranges and that the energy responses to 137Cs of the G(E) function satisfied the criteria recommended by the International Commission.
        12.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In actual seawater desalination plant, the pressure loss due to frictional force of pipe is about 3~5 bar. Also, the pressure loss at pipe connection about 1~3 bar. Therefore, the total pressure loss in the pipe is expected to be about 4~8 bar, which translates into 0.111 to 0.222 kWh/m3 of energy when converted into the Specific Energy Consumption(SEC). Reducing energy consumption is the most important factor in ensuring the economics of seawater desalination processes, but pressure loss in piping is often not considered in plant design. It is difficult to prevent pressure loss due to friction inside the pipe, but pressure loss at the pipe connection can be reduced by proper pipe design. In this study, seawater desalination plant piping analysis was performed using a commercial network program. The pressure loss and SEC for each case were calculated and compared by seawater desalination plant size.
        4,000원
        14.
        2018.11 구독 인증기관·개인회원 무료
        막증발 기술은 최근 해수담수화 분야에서 많은 주목을 받고 있으며, 기존 증발법과 역삼투를 대체하는 대안기술로서 개발이 활발하게 추진되고 있다. 그러나 막증발 기술의 실용화를 위해서는 극복하여야 할 몇 가지 문제점이 있다. 본 연구에서는 막증발 기술을 효율적으로 적용하기 위하여 해결해야 하는 1) 스케일업 2) 막오염 억제 3) 막젖음 예측 및 방지기술 개발하고자 하였으며, 이를 통하여 저탄소 담수화를 실현시키기 위한 방안을 제시하고자 하였다.
        15.
        2018.05 구독 인증기관·개인회원 무료
        기후변화에 따른 영향으로 전 세계적으로 물부족 문제는 지속적으로 증가할 것으로 예상된다. 이러한 물부족 문제를 해결하기 위하여 다양한 대체수자원 확보기술이 개발되고 있으며, 그 중에 해수담수화 기술이 가장 활발하게 도입되고 있다. 최근 새로운 개념의 해수담수화 기술이 검토되고 있으며, 그 중 막증발법(Membrane distillation, MD) 기술이 활발하게 연구되고 있다. 국토교통부 국가연구개발사업으로 진행 중인 “Global MVP 연구단”에서는 세계 최대 규모인 400 m³/일 규모의 복합탈염 플랜트를 구축하고 있으며, 국산 중공사 막증발 모듈을 이용하여 새로운 개념의 복합탈염 설계기술과 구축기술을 확보하고자 현재 다양한 연구를 진행 중에 있다.
        16.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Pulp and paper industry produces large volumes of wastewater and residual sludge waste, resulting in many issues in relation to wastewater treatment and sludge disposal. Contaminants in pulp and paper wastewater include effluent solids, sediments, chemical oxygen demand (COD), and biological oxygen demand (BOD), which should be treated by wastewater treatment processes such as coagulation and biological treatment. However, few works have been attempted to predict the treatment efficiency of pulp and paper wastewater. Accordingly, this study presented empirical models based on experimental data in laboratory-scale coagulation tests and compared them with statistical models such as artificial neural network (ANN). Results showed that the water quality parameters such as turbidity, suspended solids, COD, and UVA can be predicted using either linear or expoential regression models. Nevertheless, the accuracies for turbidity and UVA predictions were relatively lower than those for SS and COD. On the other hand, ANN showed higher accuracies than the emprical models for all water parameters. However, it seems that two kinds of models should be used together to provide more accurate information on the treatment efficiency of pulp and paper wastewater.
        4,000원
        17.
        2017.05 구독 인증기관·개인회원 무료
        본 연구는 해수담수화 플랜트의 에너지 사용량을 이론적으로 분석하고 최적화하기 위한 기법을 개발하기 위하여 수행되었다. 먼저 해수담수화 공정모사 모델을 개발하였으며 이를 이용하여 에너지 흐름을 분석하고 각 단계별 유효에너지와 에너지 손실을 계산하였다.
        18.
        2016.11 구독 인증기관·개인회원 무료
        최근 막여과 정수처리에 대한 관심이 높아지고 있으나, 공정설계를 위한 소프트웨어가 널리 보급되어 있지 않아서 현장적용의 어려움이 발생하고 있다. 본 연구에서는 막여과 정수처리 공정설계를 지원할 수 있는 프로그램과 설계기법을 개발하고자 하였다.
        19.
        2016.11 구독 인증기관·개인회원 무료
        선박에 주로 사용되는 기존 해수담수화 공정의 경우 많은 에너지가 소모 된다는 단점이 있다. 막증발법(MD)은 유입수의 삼투압으로 인한 구동력의 저하가 역삼투공정에 비해서 낮은 장점을 가지며, 비교적 낮은 온도(60 ∼ 80℃)에서 운전 가능하기 때문에 선박의 엔진 폐열, 해수열원 등을 활용하여 운전 비용을 절감할 수 있다. 본 연구에서는 실험실 규모의 진공식 막증발 장치에서 도출된 조건을 바탕으로 3 m3/일 규모의 실제 VMD 파일럿플랜트를 설계 및 제작하여 성능을 평가하였다. 운전결과, 3~5 L/㎡-hr의 플럭스와 99.99%의 염제거율을 나타냈다.
        20.
        2016.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Shale gas has become increasingly important as a viable alternative to conventional gas resources. However, one of the critical issues in the development of shale gas is the generation of produced water, which contains high concentration of ionic compounds (> TDS of 100,000 mg/L). Accordingly, membrane distillation (MD) was considered to treat such produced water. Experiments were carried out using a laboratory-scale direct contact MD (DCMD). Synthetic produced water was prepared to examine its fouling propensity in MD process. Antiscalants and in-line filtration were applied to control fouling by scale formation. Fouling rates (-dJ/dt) were calculated for in-depth analysis of fouling behaviors. Results showed that severe fouling occurred during the treatment of high range produced water (TDS of 308 g/L). Application of antiscalant was not effective to retard scale formation. On the other hand, in-line filtration increased the induction time and reduced fouling.
        4,000원
        1 2