검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 49

        21.
        2017.02 KCI 등재 서비스 종료(열람 제한)
        The objective of this research was to develop Near-Infrared Reflectance Spectroscopy (NIRS) model for amylose and protein contents analysis of large accessions of rice germplasm. A total of 511 accessions of rice germplasm were obtained from National Agrobiodiversity Center to make calibration equation. The accessions were measured by NIRS for both brown and milled brown rice which was additionally assayed by iodine and Kjeldahl method for amylose and crude protein contents. The range of amylose and protein content in milled brown rice were 6.15-32.25% and 4.72-14.81%, respectively. The correlation coefficient (R 2 ), standard error of calibration (SEC) and slope of brown rice were 0.906, 1.741, 0.995 in amylose and 0.941, 0.276, 1.011 in protein, respectively, whereas R 2 , SEC and slope of milled brown rice values were 0.956, 1.159, 1.001 in amylose and 0.982, 0.164, 1.003 in protein, respectively. Validation results of this NIRS equation showed a high coefficient determination in prediction for amylose (0.962) and protein (0.986), and also low standard error in prediction (SEP) for amylose (2.349) and protein (0.415). These results suggest that NIRS equation model should be practically applied for determination of amylose and crude protein contents in large accessions of rice germplasm.
        22.
        2016.12 KCI 등재 서비스 종료(열람 제한)
        Near infrared reflectance spectroscopy (NIRS) has been used as a rapid analysis tool to many components in cereal grains. This study was to investigate the potential NIRS application for determination of components in Korean wheat. Main components of wheat quality are protein content, moisture content, SDS-sedimentation volume and ash content. Wheat has screened for quality, hardness of seed by NIRS in CIMMYT (International Maize and Wheat Improvement Center). NIRS calibration was used as a rapid and simultaneous analysis method to determine the wheat quality components. A total of 282 wheat samples, collected from a wide range of Korean wheat cultivation region for 2 years, were analyzed by NIRS. NIRS calibration of individual components were developed using first derivation, second derivation and modified partial least-squares regression and internal cross validation method. As a result, calibration formula of protein was y=0.937x+0.786, calibration formula of moisture was y=0.922x+0.911, calibration formula of ash was y=0.933x+0.08, calibration formula of SDS-sedimentation volume was y=0.947x+2.150. NIRS calibration for wheat quality may be useful for determining protein(R2 = 93.6), moisture(R2 = 91.6), SDS-sedimentation volume(R2 = 94.3), and ash(R2 = 93.4). This study shows that 4 calibrations of NIRS is a useful application in the accurate and rapid determination of wheat quality. Therefore, NIRS could be used to rapidly determine the quality contents of wheat for grade evaluation in a purchasing of wheat cultivation region.
        23.
        2016.12 KCI 등재 서비스 종료(열람 제한)
        This study was investigated to develop mass evaluation system for the contents of crude protein, oil and fatty acid in soybean germplasm using NIRS. NIRS equations were created with 345 soybeans, multiple correlation coefficients of crude protein, oil, palmitic, stearic, oleic, linoleic and linolenic acid between data obtained from NIRS and quantitative analysis were 0.983, 0.969, 0.592, 0.514, 0.978, 0.961 and 0.957, respectively. Equation statistics indicated that contents of crude protein, oil and unsaturated fatty acid except palmitic and stearic acid in soybean seed were suitable for determination by NIRS. Those NIRS equations were applied to examine crude protein, oil and unsaturated fatty acid of 854 soybean landraces from Korea. The average contents and ranges of crude protein and oil were 39.2% with a range of 33.7-47.0% and 15.0% with a range of 9.8-20.3%, individually. In addition, those of oleic, linoleic and linolenic acid were 21.4% with a range of 12.1-30.2%, 55.6% with a 47.8-62.3% and 8.1% with a range of 5.9-10.7% respectively. We conducted quantitative analysis to reconfirm with IT154552 (45.1%) and IT023955(46.9%) above 45% of crude protein, the results were similar from NIRS (45.2%, 47.0%). NIRS data for protein from this study made no difference with lab data, which would be useful for mass evaluation. There was negative correlation (-0.203) between crude protein and oil, positive correlation (0.379) between crude oil and oleic acid, and significantly negative correlation (-0.879) between oleic and linoleic acid.
        24.
        2016.03 KCI 등재 서비스 종료(열람 제한)
        This study was conducted to develop a fast and efficient screening method to determine the quantity of fatty acid in peanut oil for high oleate breeding program. A total of 329 peanut samples were used in this study, 227 of which were considered in the calibration equation development and 102 were utilized for validation, using near infrared reflectance spectroscopy (NIRS). The NIRS equations for all the seven fatty acids had low standard error of calibration (SEC) values, while high R2 values of 0.983 and 0.991 were obtained for oleic and linoleic acids, respectively in the calibration equation. Furthermore, the predicted means of the two main fatty acids in the calibration equation were very similar to the means based on gas chromatography (GC) analysis, ranging from 36.7 to 77.1% for oleic acid and 7.1 to 42.7% for linoleic acid. Based on the standard error of prediction (SEP), bias values, and R 2 statistics, the NIRS fatty acid equations were accurately predicted the concentrations of oleic and linoleic acids of the validation sample set. These results suggest that NIRS equations of oleic and linoleic acid can be used as a rapid mass screening method for fatty acid content analysis in peanut breeding program.
        25.
        2014.07 서비스 종료(열람 제한)
        Soybeans have been the favored livestock forage for centuries. However, little studies have been succeed in estimating forage quality of soybean by near-infrared reflectance spectroscopy (NIRS). To establish NIR equations for soybean forage quality, 353 forage soybean samples, including an 181 recombinant inbred line population derived from PI 483463 (G. soja) ´ Hutcheson (G. max), 104 cultivated soybeans (G. max) and 68 wild soybeans (G. soja) were used to develop NIR for four quality parameters: crude protein (CP), crude fat (CF), neutral detergent fiber (NDF), and acid detergent fiber (ADF). Two NIR spectroscopy equations developed for CP and CF (2,5,5,1; multiple scatter correction [MSC]) and for NDF and ADF (1,4,4,1; MSC) were the best prediction equations for estimating these parameters. The coefficients of determination in external validation set (r2) were 0.934 for CF, 0.909 for CP, 0.767 for NDF, and 0.748 for ADF. The relative predictive determinant (RPD) ratios for MSC (2,5,5,1) calibration indicate that the CP (3.34) and CF (3.45) equations were acceptable for quantitative prediction of soybean forage quality, whereas the NDF (2.34) and ADF (1.97) equations were useful for screening purposes. The NIR calibration equations developed in this study will be useful in predicting the contents of forage qualities and in breeding soybean for forage
        26.
        2012.12 KCI 등재 서비스 종료(열람 제한)
        Brown rice grain pigments of black rice have a higher content of bioactive substances such as anti-mutagenic substance than the non-pigmented rice grain. The major anthocyanin pigment contained in black rice was cyanidin-3-glucoside. This study was conducted to establish a rapid analysis method for determining cyanidin-3-glucoside contents in flour and whole rice seeds of black rice using VIS/NIRS technique. A total of 60 black rice samples were used for VIS/NIRS equation model development and validation. The value of coefficient of determination of external validation (r 2 ) and standard error of performance (SEP) in whole rice seed sample were 0.653 and 97.2, respectively. Therefore, the value of it seemed to be difficult to analyze cyanidin-3-glucoside content in whole rice seed samples using VIS/NIRS. However, in rice flour sample, the best accurate equation model was obtained from the partial least square regression (PLS) method. The value of r 2 , SEP and bias were 22.5, 0.922 and -1.45 in the calibration transformed to the N-point smooth of log 1/R signal, 5 factors, respectively. Therefore, the results of our study clearly demonstrate that the VIS/NIRS method would be applicable only for rapid determination of cyanidin-3-glucose content in black rice flour samples.
        27.
        2012.09 KCI 등재 서비스 종료(열람 제한)
        국내산 콩과 수입콩의 판별에 NIRS를 도입함으로써 보다 빠르고 정확한 식별분석을 하고자 실험을 수행하였다. NIRS를 사용하여 400~2,500 nm 범위에서 콩 분말의 파장을 측정하였으며, 측정된 spectrum은 WINISI II program 을 이용하여 수처리와 회귀분석을 하였다. 검량식 작성을 위한 수처리는 spectrum을 1차미분 및 4 nm gap으로 조정한 것이 가장 적합하였으며, 회귀식은 변형부분최소자승회귀법(Modified partial least squares regression)이 우수하였다. MPLS 회귀분석시 원산지 판별을 위해 loading value를 국내산 콩은 '100', 수입콩은 '1'로 처리하여 검량식을 작성하고 그 적합성을 검증한 결과 factor가 10일 때 도출된 calibration equation의 상관값이 0.98, 교차검증의 상관값이 0.94를 나타내어 상관도가 높음을 알 수 있었다. 따라서 NIRS를 이용한 국내산 콩과 수입콩의 판별분석이 가능할 것으로 판단되었다.
        28.
        2012.03 KCI 등재 서비스 종료(열람 제한)
        The objective of this study was to rapidly evaluate fatty acids in a collection of millet (Panicum miliaceum subsp. miliaceum) of different origins so that this information could be disseminated to breeders to advance germplasm use and breeding. To develop the calibration equations for rapid and nondestructive evaluation of fatty acid content, near-infrared reflectance spectroscopy (NIRs) spectra (1104-2494 nm) of samples ground into flour (n =100) were obtained using a dispersive spectrometer. A modified partial least-squares model was developed to predict each component. For foxtail millet germplasm, our models returned coefficients of determination (R2 ) of 0.89, 0.89, 0.89, and 0.92 for palmitic acid, oleic acid, linoleic acid, and total fatty acids, respectively. The prediction of the external validation set (n=10) showed significant correlation between references values and NIRs values (r2 =0.64, 0.90, 0.79, and 0.89 for palmitic acid, oleic acid, linoleic acid, and total fatty acids, respectively). Standard deviation/standard errors of cross-validation (SD/SECV) values were close to 3 (2.62, 2.40, 1.85, and 2.23 for palmitic acid, oleic acid, linoleic acid, and total fatty acids, respectively). These results indicate that these NIRs equations are functional for the mass screening and rapid quantification of the oleic and total fatty acids characterizing millet germplasm. Among the samples, IT153514 showed an especially high content of fatty acids (48.14mg~;g-1 ), whereas IT123909 had a very low content (34.44mg~;g-1 ).
        29.
        2011.03 KCI 등재 서비스 종료(열람 제한)
        This experiment was carried out to find suitable sample type for the more accurate prediction and non-destructive way in the application of near infrared reflectance spectroscopy (NIRS) technique for estimation the protein, total amino acids, and total isoflavone of soybean by comparing three different sample types, single seed, whole seeds, and milled seeds powder. The coefficient of determination in calibration (R2 ) and coefficient of determination in cross-validation (1-VR) for three components analyzed using NIRS revealed that milled powder sample type yielded the highest, followed by single seed, and the whole seeds as the lowest. The coefficient of determination in calibration for single seed was moderately low(R2 0.70-0.84), while the calibration equation developed with NIRS data scanned with whole seeds showed the lowest accuracy and reliability compared with other sample groups. The scatter plot for NIRS data versus the reference data of whole seeds showed the widest data cloud, in contrary with the milled powder type which showed flatter data cloud. By comparison of NIRS results for total isoflavone, total amino acids, and protein of soybean seeds with three sample types, the powder sample could be estimated for the most accurate prediction. However, based from the results, the use of single bean samples, without grinding the seeds and in consideration with NIRS application for more nondestructive and faster prediction, is proven to be a promising strategy for soybean component estimation using NIRS.
        30.
        2010.12 KCI 등재 서비스 종료(열람 제한)
        Kjeldahl method used in many materials from various plant parts to determine protein contents, is laborious and time-consuming and utilizes hazardous chemicals. Near-infrared (NIR) reflectance spectroscopy, a rapid and environmentally benign technique, was investigated as a potential method for the prediction of protein content. Near-infrared reflectance spectra(1100-2400 nm) of coarse cereal grains(n=100 for each germplasm) were obtained using a dispersive spectrometer as both of grain itself and flour ground, and total protein contents determined according to Kjeldahl method. Using multivariate analysis, a modified partial least-squares model was developed for prediction of protein contents. The model had a multiple coefficient of determination of 0.99, 0.99, 0.99, 0.96 and 0.99 for foxtail millet, sorghum, millet, adzuki bean and mung bean germplasm, respectively. The model was tested with independent validation samples (n=10 for each germplasm). All samples were predicted with the coefficient of determination of 0.99, 0.99, 0.99, 0.91 and 0.99 for foxtail millet, sorghum, millet, adzuki bean and mung bean germplasm, respectively. The results indicate that NIR reflectance spectroscopy is an accurate and efficient tool for determining protein content of diverse coarse cereal germplasm for nutrition labeling of nutritional value. On the other hands appropriate condition of cereal material to predict protein using NIR was flour condition of grains.
        31.
        2010.10 KCI 등재 서비스 종료(열람 제한)
        The objective of this study was to rapidly evaluate fatty acids in a collection of foxtail millet (Setaria italica (L.) P. Beauv) of different origins so that this information could be disseminated to breeders to advance germplasm use and breeding. To develop the calibration equations for rapid and nondestructive evaluation of fatty acid content, near-infrared reflectance spectroscopy (NIRs) spectra (1104-2494 nm) of samples ground into flour (n=100) were obtained using a dispersive spectrometer. A modified partial least-squares model was developed to predict each component. For foxtail millet germplasm, our models returned coefficients of determination (R2) of 0.91, 0.89, 0.98 and 0.98 for strearic acid, oleic acid, linoleic acid, and total fatty acids, respectively. The prediction of the external validation set (n=10) showed significant correlation between references values and NIRs values (r2=0.97, 0.91, 0.99 for oleic, linoleic, and total fatty acids, respectively). Standard deviation/standard error of cross-validation (SD/SECV) values were greater than 3 (3.11, 5.45, and 7.50 for oleic, linoleic, and total fatty acids, respectively). These results indicate that these NIRs equations are functional for the mass screening and rapid quantification of the oleic, linolenic, and total fatty acids characterizing foxtail millet germplasm. Among the samples, IT153491 showed an especially high content of fatty acids (84.06 mg g-1), whereas IT188096 had a very low content (29.92 mg g-1).
        32.
        2008.12 KCI 등재 서비스 종료(열람 제한)
        녹차 품질평가의 한 요인이 되는 색도 평가 시 기존 평가 방법인 육안평가 혹은 색차 분석에 의존하고 있는 현행 분석방법을 신속, 간편하며 재현성이 높고, 녹차 품질관련 기타 성분과 동시분석이 가능한 녹차 색차 분석용 NIRS 검량식을 작성한 결과를 요약하면 다음과 같다. 1. 공시된 녹차 시료를 대상으로 색차계를 이용하여 색도 값(L, a, b)을 조사한 결과 검량식 작성용 시료는 L값이 평균 53.37(48.52~57.72 ), a값이 평균 -7.55(-10.02~-4.63 ), b 값이 평균 18.07(14.00~22.02 )을 나타내었고, 작성 검량식의 평가용으로 이용된 예견치 분석용 시료와 거의 동일한 범위를 나타내었다. 2. 녹차의 색차 분석용 NIRS 검량식을 검토한 결과 색차 중 명도에 해당하는 L 값은 원시 스펙트럼에 2차 미분(2nd derivative, 8 nm gap, 6 points smoothing, 1 point second smoothing)을 수행한 조건에서 R2 = 0.936으로 가장 우수한 양상을 나타내었고, 적색에 해당되는 색차 a값과 황색에 해당하는 b값은 1차 미분(1st derivative, 4 nm gap, 4 points smoothing, 1 point second smoothing)조건에서 R2 가 각각 0.991 및 0.958로 가장 우수한 결과를 나타내었다. 3. 최적의 녹차 색차 분석용으로 작성된 각각의 NIRS 검량식을 미지시료에 적용하여 정확성을 평가한 결과 색도값 L, a 및 b의 결정계수는 각각 0.905, 0.986 및 0.931로 매우 높은 상관을 보였으며, 이들 검량식은 향후 NIRS를 이용한 녹차 관련 연구 및 녹차 산업현장에서 품질관리를 위한 효율적 분석방법으로 활용이 가능할 것으로 판단된다.
        33.
        2008.06 KCI 등재 서비스 종료(열람 제한)
        본 시험은 종자은행이 보유하고 있는 다양한 벼 유전자원의 활용을 촉진하기 위하여 비파괴적인 분석방법의 하나인 근적외선 분광분석법을 이용한 유용유전자원의 대량 선발체계 구축을 위해 실시하였다. 1. NIR스펙트럼은 700 nm 이하의 가시광선 범위에서 다양한 범위의 spectrum을 보였으며, 700 nm에서 2500 nm의 근적외선 파장에서도 spectrum의 차이가 크게 나타났고, 1400 nm에서 전체 spectrum의 정점을 나타냈으며 그 이상의 spectrum에서는 포화현상을 나타내었다. 2. NIR 검량식 작성에 이용된 144점의 선발자원이 가지는 단백질함량의 범위는 6.5~9.5% 였으며, 134점의 선발자원이 가지는 아밀로스함량의 범위는 18.1~21.7% 이었다. 3. 단백질함량과 아밀로스함량의 실험치(Lab data)와 NIR 데이터의 모집단 분포의 해석과 상관관계에 관한 통계분석 결과, 단백질함량과 아밀로스함량의 R2 (RSQ) 값은 각각 0.786과 0.865로 높게 보였으며, 검량식 표준오차(SEC)는 각각 0.442와 2.078로 유의한 값을 보였고, 또한 검량식 검정 표준오차(SECV)도 각각 0.541과 3.106으로 유의한 값을 보였지만 검증시 상관정도(1-VR)는 0.68과 0.70로 검량식 작성시보다 낮은 유의성을 보였다.
        37.
        2006.12 KCI 등재 서비스 종료(열람 제한)
        To investigate seed non destructive and fast determination technique utilizing near infrared reflectance spectroscopy (NIRs) for screening ultra high oleic (C18:1) and linoleic (C18:2) fatty acid content sesame varieties among genetic resources and lines of pedigree generations of cross and mutation breeding were carried out in National Institute of Crop Science (NICS). 150 among 378 landraces and introduced cultivars were released to analyse fatty acids by NIRs and gas chromatography (GC). Average content of each fatty acid was 9.64% in palmitic acid (C16:0), 4.73% in stearic acid (C18:0), 42.26% in oleic acid and 43.38% in linoleic acid by GC. The content range of each fatty acid was from 7.29 to 12.27% in palmitic, 6.49% from 2.39 to 8.88% in stearic, 12.59% of wider range compared to that of stearic and palmitic from 37.36 to 49.95% in oleic and of the widest from 30.60 to 47.40% in linoleic acid. Spectrums analyzed by NIRs were distributed from 400 to 2,500 nm wavelengths and varietal distribution of fatty acids were appeared as regular distribution. Varietal differences of oleic acid content good for food processing and human health by NIRs was 14.08% of which 1.49% wider range than that of GC from 38.31 to 52.39%. Varietal differences of linoleic acid content by NIRs was 16.41% of which 0.39% narrower range than that of GC from 30.60 to 47.01%. Varietal differences of oleic and linoleic acid content in NIRs analysis were appeared relatively similar inclination compared with those of GC. Partial least square regression (PLSR) among multiple variant regression (MVR) in NIRs calibration statistics was carried out in spectrum characteristics on the wavelength from 700 to 2,500 nm with oleic and linoleic acids. Correlation coefficient of root square (RSQ) in oleic acid content was 0.724 of which 72.4 percent of sample varieties among all distributed in the range of 0.570 percent of standard error when calibrated (SEC) which were considerably acceptable in statistic confidence significantly for analysis between NIRs and GC. Standard error of cross validation (SECV) of oleic acid was 0.725 of which distributed in the range of 0.725 percent standard error among the samples of mother population between analyzed value by NIRs analysis and analyzed value by GC. RSQ of linoleic acid content was 0.735 of which 73.5 percent of sample varieties among all distributed in the range of 0.643 percent of SEC. SECV of linoleic acid was 0.711 of which distributed in the range of 0.711 percent standard error among the samples of mother population between NIRs analysis and GC analysis. Consequently, adoption NIR analysis for fatty acids of oleic and linoleic instead that of GC was recognized statistically significant between NIRs and GC analysis through not only majority of samples distributed in the range of negligible SEC but also SECV. For enlarging and increasing statistic significance of NIRs analysis, wider range of fatty acids contented sesame germplasm should be kept on releasing additionally for increasing correlation coefficient of RSQ and reducing SEC and SECV in the future.
        38.
        2005.09 KCI 등재 서비스 종료(열람 제한)
        In order to find out an alternative way of analysis of food waste compost, the Near Infrared Reflectance Spectroscopy(NIRS) was used for the compost assessment because the technics has been known as non-detructive, cost-effective and rapid method. One hundred thirty six compost samples were collected from Incheon food waste compost factory at Namdong Indurial Complex. The samples were analyzed for nitrogen, organic matter (OM), ash, P, and K using Kjedahl, ignition method, and acid extraction with spectrophotometer, respectively. The samples were scanned using FOSS NIRSystem of Model 6500 scanning monochromator with wavelength from 400~2,400㎚ at 2nm interval. Modified partial Least Squares(MPLS) was applied to develop the most reliable calibration model between NIR spectra and sample components such as nitrogen, ash, OM, P, and K. The regression was validated using validation set(n=30). Multiple correlation coefficient(R²) and standard error of prediction(SEP) for nitrogen, ash, organic matter, OM/N ratio, P and K were 0.87, 0.06, 0.72, 1.07, 0.68, 1.05, 0.89, 0.31, 0.77, 0.06, and 0.64, 0.07, respectively. The results of this experiment indicates that NIRS is reliable analytical method to assess some components of feed waste compost, also suggests that feasibility of NIRS can be justified in case of various sample collection around the year.
        40.
        2002.12 KCI 등재 서비스 종료(열람 제한)
        삼지구엽초에 함유되어 있는 icariin 함량을 신속하게 추정하기 위하여 NIRS(근적외선 분광분석기)를 이용한 분석 방법을 검토하였다. HPLC를 이용하여 분석된 삼지구엽초 유전자원 150계통에 대한 이카린 함량치를 NIRS 스펙트럼에 적용시켜 42개의 calibration set 와 26개의 valilion set를 구분하였다. NIRS의 검량식을 몇가지 방법에 의하여 비교분석한 결과 2차미분된 스텍트럼을 MPLS(Modified Partial Least Squares)를 이용한 회귀식에 이용하는 것이 가장 적합하였다. HPLC를 이용한 유전자원들의 이카린 함량은 평균 0.424%(0.12~0.67%)이었으며, NIRS에서 도출된 검량식과의 상관계수는 0.951을 나타내었다. 따라서 삼지구엽초의 이카린 함량은 NIRS를 이용하여 신속 편리하게 분석할 수 있음이 인정되었다.
        1 2 3