        661.
        2017.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Experimental evaluation of torsional behavior, which is possible behavior of seismic beams of RC structures, was carried out. Concrete strength and stirrup spacing were set as experimental variables to investigate the torsional strength of RC beams. Based on the experimental results, the torsional strength of RC beams was compared and analyzed. From the experimental results, the concrete strength was caused a difference of about 30% in the torsional strength of the maximum torque of the RC beam specimen, and the stirrup spacing was found to be about 2.8 times and 5 times that of the peak torque. Therefore, this study will be an important study to understand the effect of both concrete strength and stirrup spacing for the torsional strength or torsional behavior of RC beams.
        4,000원
        662.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 콘크리트 석션식 지지구조물을 사용한 해상풍력발전시스템의 지진응답 해석을 수행하여 그 거동 특성을 파악한다. 전체 시스템을 RNA, 타워, 지지구조물로 구성된 구조계와 이에 접하고 있는 유체 및 지반의 부분구조로 분리하여 운동방정식을 유도한다. 구조계에 작용하는 유체의 동수압과 지반의 상호작용력을 산정하고, 이를 구조계의 운동방정식과 결합하여 전체 시스템의 지배방정식을 도출한 후, 이 방정식의 해를 구하여 해상풍력발전시스템의 지진응답을 계산한다. 해 석 결과로부터 지반-구조물 상호작용은 콘크리트 석션식 지지구조물에 의해 지지된 해상풍력발전시스템의 지진응답을 크게 증가시킬 수 있음을 확인할 수 있다. 특히, 지반의 유연성으로 인해 시스템의 고차 고유모드 응답이 증가할 수 있으므로, 해 상풍력발전시스템의 동적거동 산정 시에는 반드시 지반-구조물 상호작용의 효과를 고려하여야 할 것이다.
        4,000원
        663.
        2017.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the seismic design of building structural members, due to the complexity of the placement of PC steels in prestressed concrete members, it is necessary to review and define the definition of member damage in comparison with reinforced concrete members.In this study, the results of past experiments compared with the calculation results by ‘section Analysis Method’, with the aim of reviewing the precision of calculation results when member damage evaluation is performed using the section analysis method. Furthermore, it is also compared with the calculation results by the ‘split Element Method’.In addition, parametric studies were carried out, and the influence of the difference between the amount of PC steels and reinforced bar on the residual strain was examined.
        4,000원
        664.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study presents a sustainable design method to optimize the embodied energy and CO2 emission complying with the design code for reinforced concrete column. The sustainable design method effectively achieves the minimization of the environmental load and energy consumption whereas the conventional design method has been mostly focused on the cost saving. Failure of reinforced concrete column exhibits compressive or tensile failure mode against an external force such as flexure and compression; thus, optimization analyses are conducted for both failure modes. For the given sections and reinforcement ratios, the optimized sections are determined by optimizing cost, embodied energy, and CO2 emission and various aspects of the sections are thoroughly investigated. The optimization analysis results show that 25% embodied energy and 55% CO2 emission can be approximately reduced by 10% increase in cost. In particular, the embodied energy and CO2 emission were more effectively reduced in the tensile failure mode rather than in the compressive failure mode. Consequently, it was proved that the sustainable design method effectively implements the concept of sustainable development in the design of reinforced concrete structure by optimizing embodied energy consumption and CO2 emission.
        4,000원
        665.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to evaluate a stress state of concrete according to the change of tensile force of prestressed beam, improved nonlinear resonant ultrasonic spectroscopy(NRUS) method is proposed. This technique is advantageous to evaluate the stress state in initial state because the method shows much higher sensitivity than existing linear ultrasonic methods. The NRUS technique measure a nonlinearity parameter, which is calculated from the resonant frequency shift of ultrasonic wave related to the medium state, and the result is also closely related to the stress state of concrete. In this study, the nonlinearity parameter was measured with the change of tensile force to verify the close relationship between the two factors, and the effect of repetitive load cycle on the change of nonlinearity parameter was analyzed. In addition, sensitivity comparison with the linear ultrasonic pulse velocity method was performed. Through the experimental results, the possibility of NRUS technique for the evaluation of stress state in prestressed beam was confirmed.
        4,000원
        668.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to make a generalized analytical based on the proposed experiments on reinforced concrete(RC) partially infilled frames by U-type precast concrete(PC) wall panels with openings. RC frame and PC wall panels were connected with different strengths. Therefore, we developed modified strut-tie model(STM) with two seismic retrofitting specimens and conducted a nonlinear analysis by using a computer analysis program. Based on the test results, truss member of modified STM was designed, applying the strut-tie model theory of ACI 318M-11 Appendix- A. As a result, the modified STM analysis results were very similar to the experimental results. As a result of the load-displacement curve comparison, the failure load were similar within 5∼17% of error range. In particular, the experimental results and the results of modified STM analysis show that the failure behavior almost matched.
        4,200원
        669.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Cyclic loading test was performed on the partially infilled reinforced concrete(RC) frames by L-type precast concrete(PC) wall panels with the connections of two different strength. Based on the results of experimental test, the nonlinear analysis was practiced with modified strut-tie model(STM) method by using a computer program. Truss member of modified STM was designed, applying the strut-tie model theory of ACI 318M-11 Appendix-A. Modified STM was designed with two ways according to the test result. PC wall panel and RC frame were assumed to composite when push loading applied. The PC and RC structures were also assumed to behave non-composite and those two structures connected with link(top connector) when pull loading applied. The connection was designed by using elastic link of program. The results of analytical modified STM process generally conform to the experimental results. The failure load and the failure mode of the specimens could be predicted using modified STM. The ratio of failure load measured in specimens to analytical values were between 0.83∼1.16. The member or connection which was failed in experiment yield in the results of modified STM. The failure mode perfectly matched.
        4,500원
        670.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : The pole electrode method damaged the concrete pavement on inserting the electrode into the pavement surface. This study examined the feasibility of the flat electrode method to observe the concrete pavement instead of the pole electrode method and analyzed the resistivity characteristics of the concrete by performing laboratory tests. METHODS : The resistivity of the concrete specimens manufactured with three different mixing ratios (38.50%, 39.50%, and 40.50%) were measured using the pole and flat electrode methods according to the concrete age (7 and 28 days) and electrode spacing (20 mm, 30 mm, and 40 mm). RESULTS : In both pole and flat electrode methods, the resistivity increased with increasing fine aggregate proportion regardless of the concrete age. The resistivity measured at a concrete age of 28 days was slightly larger than that measured at 7 days. In the case of a concrete age of 7 days, the resistivity measured by the flat electrode method was larger than that measured by the pole electrode method. The difference disappeared at 28 days. CONCLUSIONS: The results suggest that the flat electrode method can replace the pole electrode method because the resistivity measured by both methods was similar. Hence, the development of a technology to apply the flat electrode method to actual concrete pavement is necessary.
        4,000원
        671.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to establish a seismic resistance performance evaluation method that makes sure to secure the seismic resistance performance of the existing mid-low story reinforced concrete structures. This study focuses on the development of the seismic resistance performance evaluation method for the overall seismic resistance performance evaluation on the buildings by applying fuzzy theory. This seismic resistance performance evaluation method considers the mutual relations among the type of force, the type of member, the type of story, and the states of deterioration of the buildings. The total seismic resistance performance index from this method was calculated by the intensity weight of each evaluation item, fuzzy measure, fuzzy integration. Moreover, the evaluation methodology was established in this study to identify the performance level of the Immediate Occupancy, Life Safe, Collapse Prevention by applying the fuzzy theory.
        4,000원
        672.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: The objective of this study is to verify the effect of fiber grid reinforcement on the long-term performance of asphalt pavement overlaid on old concrete pavement by performing field investigation, laboratory test, and finite element analysis. METHODS : The reflection cracking, roughness, and rutting of fiber grid reinforced overlay sections and ordinary overlay sections were compared. Cores were obtained from both the fiber grid reinforced and ordinary sections to measure bonding shear strength between the asphalt intermediate and asphalt overlay layers. Fracture energy, displacement after yield, shear stiffnesses of the cores were also obtained by analyzing the test results. Finite element analysis was performed using the test results to validate the effect of the fiber grid reinforcement on long-term performance of asphalt pavement overlaid on the old concrete pavement. The fatigue cracking and reflection-cracking were predicted for three cases: 1) fiber grid was not used; 2) glass fiber grid was used; 3) carbon fiber grid was used. RESULTS : The reflection-cracking ratio of fiber grid reinforced sections was much smaller than that of ordinary sections. The fiber grid reinforcement also showed reduction effect on rutting while that on roughness was not clear. The reflection-cracking was not affected by traffic volume but by slab deformation and joint movement caused by temperature variation. The bonding shear strength of the fiber grid reinforced sections was larger than that of the ordinary sections. The fracture energy, displacement after yield, and shear stiffnesses of the cores of the fiber grid reinforced sections were also larger than those of the ordinary sections. Finite element analysis results showed that fatigue cracking of glass or carbon fiber grid reinforced pavement was much smaller than that of ordinary pavement. Carbon fiber grid reinforcement showed larger effect in elongating the fatigue life of the ordinary overlay pavement compared to glass fiber grid reinforcement. The binder type of the overlay layer also affected the fatigue life. The fiber grid reinforcement resisted reflection-cracking and the carbon fiber grid showed the greater effect. CONCLUSIONS: The results of field investigation, laboratory test, and finite element analysis showed that the fiber grid reinforcement had a better effect on improving long-term performance of asphalt pavement overlaid on the old concrete pavement.
        4,500원
        673.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: This study investigates the effect on concrete pavement accordance with the curing methods in cool weather and supports the best method in the field. METHODS: Two field tests evaluated the curing methods of concrete pavement in cool weather. Firstly, five curing methods were tested, including normal curing compound, black curing compound, bubble sheet, curing mat, and curing mat covered with vinyl. Concrete maturity was compared from temperature data. Secondly, normal curing compound and curing mat with vinyl, which showed the best performance, were compared in terms of maturity and join condition index. RESULTS: From the field tests, it is an evident that curing mat with vinyl accelerated the concrete strength. Therefore, it is possible to conduct saw-cut works in cool weather, which minimizes damage on concrete at joint. CONCLUSIONS: For concrete pavement in cool weather, using curing mat with vinyl as the curing method could overcome the strength delay. Therefore, strength and durability problems on concrete at joint due to cool weather would be fewer in the future.
        4,000원
        674.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : This paper focuses on strength development according to the mix design with cement type and mineral admixture from laboratory and field tests in cool weather. METHODS : Two methods evaluated the mix design of concrete pavement in cool weather. Firstly, laboratory tests including slump, air contents, setting time, strength, maturity, and freezing-thawing test were conducted. Three alternatives were selected based on the tests. Secondly, a field test was conducted and the optimum mix design in cool weather was suggested . RESULTS : It is an evident from the laboratory test that a mix with type Ⅲ cement showed better performance than the one with type Ⅰ cement. There was a delay in strength development of a mix with mineral admixture compared to mix design without any mineral admixture. In the field test, type Ⅲ cement+flyash 20% mix design proved the best performance. CONCLUSIONS : For concrete pavement in cool weather, mix design using type Ⅲ cement could overcome the strength delay due to mineral admixture. Moreover, it is possible to make sure of durability of pavement. Therefore, strength and durability problems due to cool weather would decrease.
        4,000원
        675.
        2017.05 구독 인증기관·개인회원 무료
        3D프린팅 공법은 설계 데이터 및 제품의 특성에 따라 액체 또는 분말가루 형태의 폴리머, 금속 등의 재료를 사용한다. 3D프린팅 공법의 제조방식은 적층방식으로 입체구조물을 층층이 쌓아올려 3차원형상을 제조하는 방식을 말한다. 3D프린팅 기술은 30년(1980년대) 전에 개발된 기술이지만 최근 몇 년 사이에 업계의 관심이 집중되고 있다. 3D프린팅 기술의 적용범위는 기계 산업분야에서 의료분야, 항공 분야, 건설 및 토목분야 등으로 그 범위가 점점 확대되어가 고 있다 컨투어크래프팅(Contour Crafting)은 미국 남가주대학에서 15년(2000) 전에 세라믹재료를 이용하여 개발된 3D프린팅 공법이다. Trowel 구조를 도입하여 3D프린팅 공법의 핵심적 단점인 외부표면을 매끄럽게 하면서 3D자유형상을 제작하는 것이다. 현재의 이 공법은 시멘트를 이용 하여 구조물의 부가구성물뿐만이 아니라 전체구조물을 자동으로 만드는 것을 목적으로 한다. 또한 각층의 두께 및 폭이 일반 3D프린팅 공법과 비교할 수 없이 크고 넓게 함으로 건설 및 토목분야의 적용이 가능하다. 특히, 콘크리트재료를 이용하여 토목용 2차구조물 제작에 대한 기초적인 조사 및 개념을 상세히 설명된다
        677.
        2017.04 구독 인증기관 무료, 개인회원 유료
        To overcome shortcomings of fiber reinforced polymer (FRP), a hybridized FRP rebar was developed by the authors. This hybrid bar herein called “FRP Hybrid Bar” was fabricated by adopting advantages from two different materials, including glass fiber reinforced polymer (GFRP). Corrosion resistant characteristics of FRP Hybrid Bar were evaluated and the test results were explained in this paper. The use of the alternative reinforcement could allow concrete structures to extend life-span, to save maintenance and repair costs, etc. if the FRP Hybrid Bar was applied to RC structures located in a very corrosive environment, such as marina or harbor areas.
        3,000원
        678.
        2017.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As an alternative to conventional explosive methods for demolition of concrete structures and rocks, the use of non-explosive demolition agents can be considered to reduce noise, vibration, and dust emissions during the demolition process. In this study, we conduct finite element analysis for crack initiation and propagation caused by the expansion of non-explosive demolition agents in square concrete structures. The predicted crack patterns are compared with the experimental results in the literature. The minimum values of the required expansion pressure of non-explosive demolition agents are also estimated, which depend upon the arrangement of non-explosive demolition agents and empty holes. Furthermore, we investigate the effect of empty holes on the fragmentation of concrete structures, and discuss the effective arrangement of non-explosive demolition agents and empty holes for fragmentation improvement.
        4,000원
        679.
        2017.04 구독 인증기관 무료, 개인회원 유료
        The durability degradation of concrete pavement by winter deicer is brought up as a significant risk, and its maintenance brings a high expense. Therefore, a proper repair materials for such concrete pavement are required. In this study, the properties of compressive strength, ability to resist chloride ion penetration, and dry shrinkage of Chemically bonded ceramics(CBC) and Calcium Sulfo Aluminate based ultra rapid harding cement(CSA) were assessed to evaluate its applicability as a repair material of concrete pavement road. As a result, the CBC mortar flow showed a 220㎜, and the initial setting time of CBC was 18 minutes. The compressive strength of CBC mortar was 31.3㎫ in 2 hours, 56.6㎫ in 24 hours, and 79.1㎫ in 28 days, showing a significant level. And the ability to resist chloride ion penetrations of CBC showed 433 Coulombs, which fell under very low level. The drying shrinkage of CBC mortar until 56 days was between 150 × 10-6 with -100 × 10-6, showing a significant very low level. As above, CBC has excellent compressive strength, chloride ion penetration resistance, and volume stability, and showed better performance than CSA. Therefore, CBC in the future could be used in repair of concrete pavement.
        3,000원
        680.
        2017.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A tensile failure criterion that can minimize the mesh-dependency of simulation results on the basis of the fracture energy concept is introduced, and conventional plasticity based damage models for concrete such as CSC model and HJC model, which are generally used for the blast analyses of concrete structures, are compared with orthotropic model in blast test to verify the proposed criterion. The numerical prediction of the time-displacement relations in mid span of the beam during blast loading are compared with experimental results. Analytical results show that the numerical error is substantially reduced and the accuracy of numerical results is improved by applying a unique failure strain value determined according to the proposed criterion.
        4,000원