검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 367

        61.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study has implemented an experiment in which hydrogen sulfide was removed by establishing a two-stage packed tower effector filled with nutritious medium and also filling a tower that was immobilized in ceramic media after isolating and identifying the sulfur oxidizing bacteria from a sewage treatment plant. As a result, strains isolated from the sewage treatment plant were found to be similar, including Bacillus fusiformis, Bacillus anthracis sp., Paenibacillus sp., Serratia marcescens sp., Bacillus thuringiensis. The effector that immobilized isolated strains in the ceramic media achieved an approximately 90% removal rate of hydrogen sulfide, while the sterilized ceramic media not immobilized with isolated strains showed a removal rate of about 65%. In addition, the removal rate of hydrogen sulfide in the primary media packing effector immobilized with sulfur oxidizing bacteria was about 92%, while the secondary effector filled with medium had a hydrogen sulfide removal rate near 100%. In addition, 90% efficiency of removal was shown in conditions of EBCT 60s in the experiment that investigated removal rate of hydrogen sulfide according to residence-time, while the efficiency was rapidly reduced up to 45% in conditions of EBCT 30s. On the other hand, when operating for an extended period time while increasing the concentration of injected hydrogen sulfide, the amount of sulfate was increased from 2 mg/L to 12.7 mg/L, and pH was rapidly reduced to 2.7.
        4,000원
        62.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study has implemented an experiment in which hydrogen sulfide was removed by establishing a two-stage packed tower effector filled with nutritious medium and also filling a tower that was immobilized in ceramic media after isolating and identifying the sulfur oxidizing bacteria from a sewage treatment plant. As a result, strains isolated from the sewage treatment plant were found to be similar, including Bacillus fusiformis, Bacillus anthracis sp., Paenibacillus sp., Serratia marcescens sp., Bacillus thuringiensis. The effector that immobilized isolated strains in the ceramic media achieved an approximately 90% removal rate of hydrogen sulfide, while the sterilized ceramic media not immobilized with isolated strains showed a removal rate of about 65%. In addition, the removal rate of hydrogen sulfide in the primary media packing effector immobilized with sulfur oxidizing bacteria was about 92%, while the secondary effector filled with medium had a hydrogen sulfide removal rate near 100%. In addition, 90% efficiency of removal was shown in conditions of EBCT 60s in the experiment that investigated removal rate of hydrogen sulfide according to residence-time, while the efficiency was rapidly reduced up to 45% in conditions of EBCT 30s. On the other hand, when operating for an extended period time while increasing the concentration of injected hydrogen sulfide, the amount of sulfate was increased from 2 mg/L to 12.7 mg/L, and pH was rapidly reduced to 2.7.
        4,000원
        63.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구는 남성중심의 교정조직에서 남녀교정직원들의 여성 교정직원에 대한 일반적 태도와 인식을 연구분석하였다. 특히, 남성교정직원들의 여성교정직원들에 대한 인식과 태도에 관해서 여성에 대한 성 고정관념적인 역할태도가 어떠한 영향을 미쳤는지를 이해하고자 하였고, 이러한 성고정관념이 여성교정직원들 자신들에 대한 인식과 태도에 어떠한 영향을 미치는지 여부를 분석하고자 하였다. 더 나아가, 대한민국 미래교정에서 여성교도관의 역할영역의 확대가 어디까지 이루어질 수 있는지에 대한 전망과 분석을 위해서 남녀 교도관들의 여성교도관의 남성수용자 사동관리에 대한 태도와 의견에 대한 일반적 인식을 분석하고, 남녀교정직원들의 남성수용자 사동관리에 대한 태도에 영향을 미치는 요인들을 분석하였다. 이를 위해서 전국의 12개의 교도소에서 총 448명의 남녀교정직원들에게 설문조사를 실시하여 다양한 경험적 분석을 수행하였다. 분석결과, 남성교정직원들에게서 여성교정직원들에 대한 부분적 성고정관념적 인식이 존재하였다는 것을 발견하였다. 그리고 이러한 성고정관념적 인식은 여성교정공무원들에게서도 발견이 되었다. 그리고 남녀교도관 모두는 여성교정직원의 남성수용자 사동관리에 일반적으로 부정적인 의견을 가지고 있다는 것을 발견하였는데, 여기서 남녀교정직원의 차이가 발견되지 않았다. 이 연구의 결과에 대한 논의, 공헌점, 그리고 제한점 등이 결과와 논의 부분에서 논의되었다.
        8,000원
        64.
        2015.11 구독 인증기관 무료, 개인회원 유료
        The private fixed device is needed for a radiation therapy about breast cancer. But this option is wrong applies to every hospital. Thereupon, we will establish standard of option for body-specific. 42 patients on 4 months were enrolled. The option of fixed device applied to divide into 6 kinds. The images were analyzed by OBI. In result, It is excellent reproducibility of position by all body-specific that It is applied head holder, shoulder holder, cotton, kneefix.
        4,000원
        65.
        2015.11 구독 인증기관·개인회원 무료
        Atmospheric concentrations of CO2, a major cause of global warming, have been rising due to industrial development. Carbon capture and utilization, which has been introduced to cover such disadvantages, makes it possible to capture CO2, recycling byproducts as resources. However, CCU also requires large amounts of energy in order to induce reactions. Among existing CCU technologies, the process for converting CO2 into CaCO3 requires high temperature and high pressure as reaction conditions. This study proposes a method to fixate CaCO3 stably by using relatively less energy than existing methods. Following the experiment, the resulting product CaCO3 was analyzed with FT-IR; FE-SEM image and XRD patterns were also analyzed. The results showed that the CaCO3 crystal product was high-purity calcite.
        68.
        2015.10 구독 인증기관·개인회원 무료
        최근 Google-X프로젝트, 유럽의 프로메테우스 프로젝트, 일본의 eITS프로젝트, 국내 자율주행 프로젝 트 등 무인자동차 개발이 진행되고 있다. 본 논문은 통신체계(V2X) 및 무인자동차 기술 고도화 변화에 맞 추어 기반기술로서 갖추어진 WAVE(Wireless Accessible in Vehicular Environment)통신을 활용한 기 술의 고정식 검지장치의 대체 가능성에 관한 연구를 진행하였다. 고정식 검지장치는 교통정보를 통합운영센터 및 본선교통관리운영시설로 제공하는 차량 감지시스템으 로 각 차로에 대한 교통량, 속도, 점유율 및 차량길이 등을 전송하는 기능을 수행한다. 고정식 검지장치 특성상 실시간으로 개별차량의 속도정보 송수신이 불가하며, 경제성에서 비효율적이다. 즉, 기존의 시스 템 체계에서는 정보정확성을 높이고 운전자들의 요구를 충족시키기 위해서는 검지기 및 시설의 추가설치 가 필수불가결한 요소이며, 그로 인해 km당 설치대수 및 비용이 증가하고 있는 추세이다. 본 논문에서 제안하는 차량과 인프라간 WAVE통신을 활용한 기술은 차량에서 0.01초 단위로 업데이트 되는 차량 운행정보를 WAVE통신을 이용하여 인프라 장비로 전송하고, 이 데이터를 기존의 센터에서 전송 받아 정보를 처리하는 기술이다. 실험은 2차 실험으로 진행되며, 1차 실험에서는 속도별(80kph, 100kph, 110kph) 수신거리, 수신 패킷수를 측정하였으며, 실험결과 80kph에서 RSU기준 3.4km, 100kph에 RSU 기준 3.3km, 110kph에 RSU기준 3.4km까지 송수신율 97%이상인 것으로 분석되었다. 2차 실험에서는 연 속류 개활지, 터널 내부, 단속류 세 구간에서 실험을 진행하였으며, 실제 도로를 운행하며 속도 데이터를 검지하였다. 실험결과 연속류 개활지, 연속류 터널내부, 단속류에서 속도 데이터는 0.01초 단위로 송수신 이 성공적으로 이루어졌으며, 기존 고정식 검지장치 대비하여 검지 구간 사이의 차량 속도 데이터를 실시 간으로 취득할 수 있었다. 실험결과 개활지에서 구간 평균속도로 고정식 검지장치의 속도와 WAVE통신 이 용 검지속도는 10~20kph로 차이가 났으며, 터널 내에서는 30~40kph까지 차이가 발생하였다. 본 실험은 고정식 검지장치의 주요 기능 중 속도 데이터 검지 기능을 WAVE통신 기술을 활용하여 대체 가능성을 진단해보았다. WAVE통신을 이용한 속도데이터 검지는 RSU 기준 3km 이내 구간 데이터를 97%이상 수신율로 수집 가능하고, 0.01초 단위의 모든 개별차량의 속도데이터 수신이 가능한 것으로 실 험을 완료하였다.(단, RSU 송수신가능 구간(3km)내 차량이 차량단말기를 장착한 경우) 1차 2차 실험을 통하여 고정식 검지장치의 속도 검지기능은 WAVE통신 기술을 활용하여 대체 가능한 것으로 판단되었으 며, 실시간으로 데이터를 송수신할 수 있다는 점과 개별 차량의 속도를 검지하는 점에서 기존 고정식 검 지장치보다 장점을 지닌 것으로 판단된다. 또한, 경제성 측면에서 기존 고정식 검지장치는 고기능 정보제 공을 위하여 설치 대수를 비례적으로 증가해야 하는 반면, WAVE 통신기술을 활용한다면 추가 비용이 소 요되지 않아 보다 경제성 측면에서 효율화를 이룰 수 있다고 판단하였다. 고정식 검지장치에서 수집되는 자료는 속도 데이터 외에 교통량 정보, 점유율, 점유시간, 대기행렬길이 데이터가 있다. 1차, 2차 실험을 통해 속도 정보에 대한 대체 가능성을 판단하였으며 향후 그 외의 정보에 대한 가능성 판단이 필요할 것으로 생각된다.
        69.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As film products are increasingly used in a wide range of areas, from producing traditional flexible packaging to high-tech electronic products, a higher level of quality is demanded. Most film products are made in the form of rolled finished goods, therefore, various quality issues related to their shape characteristics must be addressed. The thickness of the film products is one of the most common and important critical-to-quality attributes (CTQs). Particularly, the degree of thickness uniformity is more important than other thickness parameters, because it will be potential causes of many secondary thickness-related quality problems, such as wrinkles or faulty windings. To control the degree of thickness uniformity, the fixed bending region is oneof the most important CTQs to manage. Fixed bending regions are special points in the transverse direction of a rolled product with consistent minute variations of the thickness gap. This paper describes the measurement and analysis of thickness uniformity data, which were performed in a real manufacturing field of biaxial oriented polypropylene (BOPP) film. In previous researches, quality function deployment (QFD) or fault tree analysis were used to find the most critical process attributes out to controlthe CTQ of thickness uniformity. Whereas, this paper uses traditional control charts to find the most critical process attributes out in this problem. In addition, the selection of one of the major critical process attributes (CTPs) that is expected to affect the CTQ of thickness uniformity is also described. The selected critical-to-process attributes are the controlled temperatures along the transverse direction. A dramatic improvement in thickness uniformity was observed when the selected CTPs were controlled.
        4,000원
        70.
        2015.09 구독 인증기관 무료, 개인회원 유료
        C, M, Y, K 색상의 출력물에 대하여 20°, 60°, 85°의 고정된 각도를 사용하는 상용 광택계를 이용하 여 광택값을 측정하고 이 결과를 전각 측각 광택계를 이용하여 측정한 BDRF와 비교하였다. 동일한 시료에 대하여도 상용광택계로 측정한 광택값은 사용한 각도에 따라 차이를 나타내며 BDRF 곡선의 전체 면적과 최 대높이와 비교하였을 때 입사각이 큰 85°에서의 측정값이 가장 유사한 값의 변화를 보였다. 다리미를 사용하 여 표면을 매끄럽게 하는 퓨징작업을 한 후 광택을 측정하니 BDRF의 최대값은 입사각이 작은 20°에서의 측 정값과 가장 비슷한 경향을 나타내었으며 BDRF의 면적은 85°에서의 측정값과 가장 일치하는 결과를 나타냈 다.
        4,000원
        71.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        천해역에서의 해상풍력터빈의 기초 형식으로 모노파일, 트라이포드, 재킷 등의 고정식 기초 사이의 최적의 지지구조물 선별에 대한 논의가 세계적으로 활발하게 되어왔다. 다양한 기초 형식 가운데 어떤 기초를 최종 선택하기 위해서는 경제성과 함께 동적설계 측면에서의 검토도 필요하다. 이 연구에서는 고정식 기초를 해상풍력터빈의 기초로 적용하는 경우 전체 구조물의 고유주파수에 미치는 하중 및 지반 물성치의 불확실성의 영향을 정량적으로 검토하였다. 연구결과, 모노파일의 고유주파수의 변동이 가장 심한 것을 알 수 있었고, 따라서 모노파일 기초를 설계에 반영하는 경우에는 지반 물성치의 불확실성을 최소화시키는 것이 중요하다는 것을 알 수 있었다.
        4,000원
        74.
        2015.03 구독 인증기관 무료, 개인회원 유료
        In this study, center marking process is numerically analyzed to investigate the characteristics of deformation of aluminium alloy bracket by the pin load. The proper size of groove which are required for marking system and the pressure of cylinder are predicted through the analyse of stress and strain fields of the plate. The results of this study show that von Mises stress is a maximum when the maximum of reaction force.
        3,000원
        75.
        2015.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, flat-type photocatalytic reaction system is applied to reduce toxic hexavalent chromium (Cr(VI)) to trivalent chromium (Cr(III)) in aqueous solution under UV irradiation. To overcome the limitation of conventional photocatalysis, a novel approach toward photocatalytic system for reduction of hexavalent chromium including nanotubular TiO2 (NTT) on two kinds of titanium substrates (foil and mesh) were established. In addition, modified Ti substrates were prepared by bending treatment to increase reaction efficiency of Cr(VI) in the flat-type photocatalytic reactor. For the fabrication of NTT on Ti substrates, Ti foil and mesh was anodized with mixed electrolytes (NH4F-H2O-C2H6O2) and then annealed in ambient oxygen. The prepared NTT arrays were uniformly grown on two Ti substrates and surface property measurements were performed through SEM and XRD. Hydraulic retention time(HRT) and substrate type were significantly affected the Cr(VI) reduction. Hence, the photocatalytic Cr(VI) reduction was observed to be highest up to 95% at bended(modified) Ti mesh and lowest HRT. Especially, Ti mesh was more effective as NTT substrate in this research.
        4,000원
        76.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적 : 본 논문은 임상적으로 정형화된 경추부 MR 검사에서 틀니 제거와 침 삼킴 등의 불수의적 구강 운동에 의한 움직임 인공물을 개선하기 위하여 구강 삽입 유도기구를 이용한 추가적인 검사 방법을 제안하고자 하였다. 대상 및 방법 : 2013년 12월 01일부터 2014년 1월 31일까지 경추부 질환으로 내원한 환자 중 틀니를 착용한 13명(남자: 7명, 여자: 6명, 평균 연령: 59±7.23세)을 대상으로 C-Spine 검사를 시행하였다. 대상 선정 시 폐쇄 공포증 환자, 진정제 사용 환자는 검사에서 제외하였다. 본 연구에 사용된 자기공명기기는 경추부 MR 검사에 최적화된 1.5T(Magnetom Avanto, Siemens, Germany)를 사용하였으며 고 신호 강도를 획득하기 위한 경추 전용 위상배열코일(Neck matrix coil)을 사용하였다. 실험 도구는 구강 삽입 유도 기구(Endo-piece, Vision, Korea)를 사용하였다. 실험 방법으로 대상에게 고정도구의 안정성과 검사에 관한 사항을 먼저 설명을 한 후 정상 체위앙와위(supine position)로 T₁-TSE-Sagittal, T₂-TSE-Sagittal, T₁-TSE-Axial, T₂-TSE-Axial을 획득하고 환자의 입에 구강 삽입 유도 기구를 삽입한 후 다시 T₁-TSE-Axial과 T₂-TSE-Axial을 검사하였다. 영상의 평가와 분석은 환자의 임상 소견과 판독 결과를 바탕으로 한 정성적 분석(qualitative analysis)과 SNR(signal to noise ratio)과 CNR(contrast to noise ratio)을 바탕으로 한 정량적 분석(quantitative analysis)을 사용하였다. 결 과 : SNR은 고정도구 삽입 전 T₁-TSE-Axial이 22.33±8.59, 고정도구 삽입 후 T₁-TSE-Axial이 25.21±7.93, 고정도구 삽입 전 T₂-TSE-Axial이 14.49±5.74, 고정도구 삽입 후 T₂-TSE-Axial이 16.61±6.72이었다. CNR은 T₁-TSE-Axial이 0.236±0.21이고 T₂-TSE-Axial이 0.219±0.22로 측정되었다. 정성적 분석 결과 고정도구 사용 전 T₂-TSE-Axial 에서 3.25±0.18점, 고정도구 사용 후 T₁-TSEAxial 영상이 3.95±0.14점을 나타내었다. 결 론 : 고정도구를 사용한 추가적인 검사기법의 적용으로 환자들의 불수의적 인공물이 저감화됨에 따라 영상의 대조도와 분해능이 향상되었고, 영상 판독과 질환의식별에도 기존 검사 기법에 비해 향상됨을 알 수 있었다. 특히 움직임 인공물로 인해 질환의 경계가 불분명했던 부분이 명확해 졌으며 업무의 질이 향상됨을 알 수 있었다.
        4,000원
        80.
        2014.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Immobilization of anaerobic ammonium oxidizing bacteria has been studied to enhance the biomass retention of the slowly growing bacteria and the process stability. The purpose of this study was to compare the nitrogen removal efficiency of granular and immobilized anammox bacteria with poly vinyl alcohol and alginate. The specific anammox activity of the granular, homoginized and immobilized anammox bacteria were 0.016±0.0002 gN/gVSS/d, 0.011±0.001 gN/gVSS/d and 0.007±0.0005 gN/gVSS/d, respectively. Although the activity decreased to 43.7 % of the original one due to low pH and O2 exposure during the homogination and the immobilization, it was rapidly recovered within 7 days in the following continuous culture. When synthetic T-N concentrations of 100, 200, 400, 800 mg/L were fed, the immobilized anammox bacteria showed higher nitrogen removal efficiencies at all operational conditions than those of granular anammox bacteria. When the sludge retention time was shorten below 30.7 days and the reject water was fed, the nitrite removal efficiency of the granular anammox bacteria dropped to 8 % of the initial value, while that of the immobilized anammox bacteria was maintained over 95 % of the initial one. The immobilization with poly vinyl alcohol and alginate would be a feasible method to improve the performance and stability of the anammox process.
        4,300원
        1 2 3 4 5