        검색결과 117

        101.
        2008.07 KCI 등재 서비스 종료(열람 제한)
        Using high voltage electric fields induced by high voltage AC (10-12 kV/cm, 20 kHz) and pulsed (20-30 kV/cm, 40 Hz) electric field generator as a semipermanent and environment-friendly disinfecting apparatus, the disinfection effect of coliform group in the effluent of sewage plant was investigated. The effects of electric field strength, treatment time, discharge area of a discharge tube, water quality factors (electric conductivity, pH and SS) on its death rate were examined. The death rate of coliform group was increased with increasing electric field strength and treatment time. For AC and pulsed electric field generator, the critical electric field strength was 6 kV/cm and 2 kV/cm, respectively, and the critical treatment time was 5 min and 2 min, respectively, regardless of electric field strength. Comparing the death rate of coliform group by AC and pulsed electric fields used in this study, its death rate was higher for the latter than the former, but did not increase linearly with increasing electric field strength. The results obtained for the effects of discharge area, electric conductivity, pH and SS on the death rate of coliform group using AC electric field (12 kV/cm, 20 kHz) were as follows: its death rate showed the trend to increase linearly with increasing discharge area; for the effect of electric conductivity, its death rate was increased with increasing electric conductivity, regardless of ionic species, increased with increasing cationic valency, but was similar between the same cationic valency; the pH 5~9 used in this study did not affect its death rate; its death rate was decreased with increasing SS concentration.
        102.
        2008.05 KCI 등재 서비스 종료(열람 제한)
        The bacterial community structure in biological activated carbon (BAC) process in drinking water treatment plant was investigated by Fluorescent in situ Hybridization (FISH) with rRNA-targeted oligonucleotide probe. Samples were collected at different three points in BAC process every month for one year. They were hybridized with a probe specific for the alpha, beta, gamma subclass of the class Proteobacteria, Cytophaga- Flavobacteria group and Gram-positive high G+C content (HGC) group. Total numbers of bacteria in BAC process counted by 4',6-diamidino-2-phenylindole (DAPI) staining were 5.4×1010 (top), 4.0×1010 (middle) and 2.8×1010 cells/ml (bottom). The number of the culturable bacteria was from 1.0×107 to 3.6×107 cells/ml and the culturability was about 0.05%. The faction of bacteria detectable by FISH with the probe EUB338 was about 83% of DAPI counts. Gamma and alpha subclass of the class Proteobacteria were predominant in BAC process and their ratios were over 20% respectively. In top and middle, alpha, beta and gamma subclass of the class Proteobacteria competed with each other and their percentages was changed according to the season. In bottom, gamma subclass of the class Proteobacteria was predominant all through the year. It could be successfully observed the seasonal distribution of bacterial community in biological activated carbon process using FISH.
        103.
        2007.11 KCI 등재 서비스 종료(열람 제한)
        The removal of nitrogen compounds from a wastewater is essential and it is often accomplished by biological process. An aerobic nitrate-removing bacterium was isolated from a municipal sewage treatment plant and soil. On the basis of its morphological, cultural and physiological characteristics and 16S rRNA sequencing data, this strain was identified as Pseudomonas fluorescens, and named as P. fluorescens K4. The optimal conditions of the initial pH and temperature of media for its growth were 7.0~8.0 and 30℃, respectively. P. fluorescens K4 was able to remove 99.9% of nitrate after 24 h in a culture. The strain could grow with a nitrate concentration up to 800 mg/l and was able to remove 99.9% of nitrate after 104 h of incubation. The optimal electron donor was sodium citrate for a nitrate removal. The strain K4 showed a capability of a complete nitrate removal when the initial C/N ratio was 1.0. An effect of the initial seed concentration was observed for a cell of 10% (v/v) for a nitrate removal. Especially P. fluorescens K4 could completely remove 200 mg/l ammonium for 3 days.
        105.
        2007.01 KCI 등재 서비스 종료(열람 제한)
        The purpose of this work is to investigate the water quality change characteristics of treated water in water distribution systems of Water Treatment Plants (WTPs) of Jeju City. For this, the raw water, treated water and tap water that did not pass (named as not pass-tap water) and passed through the water storage tank (named as pass-tap water) were sampled and analyzed monthly from September 2001 to August 2002, for four (W, S, B and O) WTPs except for D WTP (where treated water is not supplied continuously) among WTPs of Jeju City. The concentrations of NO3- and Cl- of treated water in distribution systems changed little, but changed seasonally, which is considered to be based on the seasonal variation of the quality of raw water. The pH of treated water changed little in distribution systems for S WTP, but for the other WTPs, the pH of not pass-tap water was similar to that of treated water and the pH of pass-tap water was higher than that of treated water. The turbidity of treated water in distribution systems changed little except for W2 of W WTP and S4 and S5 of S WTP, where it was higher than that of each treated water. The residual chlorine concentrations between treated water and not pass-tap water changed little, but those between treated water and pass-tap water changed greatly, based on the its long residence time in water storage tank and so its reaction with organic matter, etc or its evaporation. The concentrations of TTHMs (total trihalomethanes) and CHCl3 that induce cancers in water distribution systems of these WTPs, were much lower than their water quality criteria and those in other cities. The concentrations of TTHMs of treated water and not pass-tap water were similar, but concentrations of pass-tap water were 1.5 to 2.0 times higher than those of treated water and not pass-tap water, due to the reaction of residual chlorine and organic matter, etc, with the result of long residence time in water storage tank.
        106.
        2005.08 KCI 등재 서비스 종료(열람 제한)
        For the sustainable management of marine ecosystem in Masan Bay, we have to assess the carrying capacity and standard of target water quality. In this research, we assume that all pollutants loads are treated in Dukdong sewage treatment plant, then we simulate the physical-biological model for prediction water quality for the achievement of standard water quality. In 2001 year, for the achievement of COD 2.5 mg/L, we need to reduce COD 90 %, nitrogen 30 %, phosphate 90% than that of the present value. According to these results, the water quality of sewage treatment plant is required to treat COD 13.5 mg/L, nitrogen 33.3 mg/L, phosphate 6.0 mg/L. If the sewage treatment plant will be expanded much larger in 2011, it will need to be treated in COD 6.6 mg/L, nitrogen 2.5 mg/L, phosphate 5 mg/L for the achievement of water quality standard in COD 2.5 mg/L.
        107.
        2005.02 KCI 등재 서비스 종료(열람 제한)
        Statistical analysis between operating parameters and effluent quality on advanced wastewater treatment plant was performed. Through factor analysis four factors derived varimax rotation were selected each plant. Four components explained 80%, 82% of the total variance of the process, respectively. The components on MLE plant were identified in the following order:1) HRT increase and BOD load decrease by influent decrease, 2) Biomass, 3) SVI increase by internal return increase, 4) Microbial diversity by SRT increase. On A2O plant, we defined them as follows: factor 1, high MLSS by return rate increase, HRT increase by influent decrease; factor 2, biomass; factor 3, BOD of influent; factor 4 was relate to DO.
        109.
        2002.06 KCI 등재 서비스 종료(열람 제한)
        This study aimed to obtain the relative formula with the unit treatment cost according to the treatment of a sewage plant in the service area under highway. The following results were obtained. The correlative formula connected to amount of sewage(Q)generation was as follows ; between an annual amount of sale(C) showed Q=19.113·C0.9294, and between the number of users(P) showed Q=2×10-8·P2 - 0.0298·P + 75,666. The correlative formula connected to the treatment cost was as follows ; according to the amount of sewage generation showed S= 3×10-6·Q - 0.2266·Q + 29,895, according to the elimination of BOD(E) showed S= 6×10-5·E2 - 0.6717·E + 27,744, accoding to the annual amount of sale showed S=0.0005·C2 - 4.8013·C + 35,118, with the number of persons(P) using the service area showed S= 2×10-8·P2 - 0.046·P + 48,803.
        111.
        1999.10 KCI 등재 서비스 종료(열람 제한)
        The diagnostic software for the wastewater treatment plant using activated-sluge process is developed in order to increase the efficiency of management of the wastewater treatment plant. This software is based on the expert system and the visualized user interface including the diagnosis of quantitative and qualitative data. For the generalization of this software, the initialization of each unit process and updating the files can be possible.
        112.
        1999.02 KCI 등재 서비스 종료(열람 제한)
        수영하수처리장 방류수의 해중방류법과 3차 처리 시설 설치의 비용분석을 한 결과는 다음과 같다. 1) 해안에서 4km 거리와 관경을 2m의 해중방류법을 이용한 수용만의 수질을 개선시키는데 소요되는 해중방류관 건설비용은 383억 원이 소요되는 것으로 산출되었다. 2) 수영하수처리장의 유출수를 해중방류관을 통해서 방류할 경우 방류수심을 32m, Diffuser의 길이를 200m로 할 경우의 초기희석배율은 유속에 따라서 56.4∼399.2으로 계산되었다. 3) 질소를 제거하기 위한 순환법의 경우의 20년 동안의 총 비용은 1,364억 원, 인을 제거하기 위한 응집제 첨가 활성슬러지법은 1,010억 원, 해중방류법은 383억 원으로 해중방류법이 3차 처리시설을 설치하는 비용보다 약 2.6∼3.5배 비용을 적게 소요하는 것으로 산출되었다. 4) 해중방류법을 이용할 경우의 수영만의 수질영향을 예측하기 위해서 물질순환모델을 이용하여 예측한 결과 수영만의 수질이 COD, 용존무기질소(DIN)와 용존무기인(DIP)의 전 항목에서 해역환경 II등급을 만족하는 것으로 예측되었다.
        113.
        1997.06 KCI 등재 서비스 종료(열람 제한)
        This study was conducted to investigate the treatment of wastewater from acetaldehyde manufacturing plant by activated sludge process with Micrococcus roseus AW-6, Micrococcus luteus AW-22, Microbacterium lacticum AW-38 and Microbacterium laevaniformans AW-41. The COD_Mn and BOD_5 of the wastewater were 5,260㎎/L and 6,452㎎/L, respectively. pH was 1.85. The main organic component in the wastewater was acetic acid which was contained 67,600㎎/L. Optimum dilution time for activated sludge process was shown 10 times. The specific substrate removal rate(K_e) was 1.95day^-1 and the nonbiodegradable matters(S_n) were 23.2㎎/L. Saturation constant (K_e) and maximum specific growth rate(q_max) were 1,640㎎/L and 2.33day^-1, respectively. Sludge yield coefficient(Y) and endogenous respiration coefficient(K_d) were 0.28㎎ MLVSS/㎎COD and 0.02day^-1, respectively. COD_cr removal efficiency was 91% for 1.95day of hydraulic retention time.
        114.
        1995.12 KCI 등재 서비스 종료(열람 제한)
        Reuse of industrial effluents through the cooling systems in a petrochemical complex was described. The partial oxidation of the effluents from the biological treatment plant was examined, using Fenton`s reagent as a pretreatment step prior to a next treatment of the effluents. Next tertiary treatment using fixed-film reactor resulted in marked reductions in COD and suspended solids. The continuous fixed-film process with Fenton oxidation pretreatment showed a 23% increase in the COD removal efficiency when compared to that without pretreatment of Fenton oxidation under the volumetric organic loading rate of 0.1 ㎏ COD/㎥/day. The Fenton oxidation treatment seemed to be a possible method for tertiary biological treatment to reduce the residual toxicity with the enhanced biodegradation of the effluents.
        115.
        1994.12 KCI 등재 서비스 종료(열람 제한)
        본실험은 대맥의 미숙배 배양을 통한 육종기간을 단축하기 위하여 미숙배 배양시 식물체 유도, 생육 및 출수에 영향을 미치는 생장조절물질, 배의 성숙정도 및 저온처리효과를 구명하고자 실시하였으며 그 결과는 다음과 같다. 1. 미숙배 배양으로부터 줄기의 유도에는 생장조절물질이 첨가된 기본배지도 효과적이었으며, Kinetin 0.5mg/1와 GA3 5mg/l를 처리한 것 이 좋았으나 Kinetin농도가 높을 때에는 shoot 유도가 감소되었다. 2. 지베렐린을 1mg/l와 5mg/l 처리한 배지에서 초장, root길이, root수 등이 좋았으나 Kinetin이 처리된배지에서는 생육이 억제되었으며, 특히 뿌리의 생육을 억제하였다. 3. 유도된 식물체의 토양생존율은 Kinetin 5mg/l 처리시에 생존율이 가장 낮았고 무처리에서 가장 높았다. 4. 파성정도가 IV인 올보리의 20일배를 4주저온처리 하였을 때에 출수율이 높았고 출수하는데 소요되는 기간도 짧았다. 5. 저온처리후 Kinetin 5mg/l 처리한 것은 초장, root수, shoot수가 적은 반면 GA3 5mg/l 처리한 것은 생육이 좋았다. 6. 올보리는 생장조절물질과 저온처리에 따라 출수율에 차이를 보였으며 GA3 를 1mg/l처리하고 28일 저온처리하였을때 출수율이 좋았으며, 출수에 소요되는 기간이 짧았다.
        116.
        1992.12 KCI 등재 서비스 종료(열람 제한)
        The present study was performed to develop the removal system of the offensive gases, including hydrogen sulfide of acid gas, ammonia or amine of base gas, from the nightsoil treatment plant. In order to remove the offensive gases, the Fe-EDTA system liquid phase catalytic oxidation method with the bubble lift column reactor was employed. From the results obtained it was confirmed that the offensive gases can be deodorized simultaneously and also hydrogen sulfide of acid gas, ammonia of base gas completely removed at pH 6.45. In addition, as input gases feed rate the efficiency of acid gas did not change but the efficiency of base gases decreased to approximately 90% at pH 6.0. From the result of particle size analyzer, it was found that the particle sizes including sulfur and other impurites grew up to 21μm over 72hour reaction time.
        117.
        1989.12 KCI 등재 서비스 종료(열람 제한)
        전보 10)의 경과 품종, 종자숙도의 차이에 따라 중배축 신장성 정도가 다르게 나타난 것이 유전 또는 생리적 특성의 차에 기인한 것인지를 구명하기 위해 수행하였던 바 실험결과를 요약하면 다음과 같다. 1. 습윤.고온처리에 의한 중배축 신장 효과는 처리구가 무처리구보다도 7배 이상 크게 신장하여 그 효과가 현저하였다. 2. 토양수분 함량에 따른 중배신장은 수분함량 8%구에서 최고치를, 16%구에서 최저치를 나타내 토양수분함량이 높을수록 작아지는 경향이었다. 3. 식물 Hormone중 중배축신장 효과는 cis-ABA 처리구가 GA3 , IAA 및 Kinetin 처리구보다도 그 효과가 현저하게 컸다. 4. 중배신장과 분리근장과는 어떠 뚜렷한 경향을 찾을 수 없었으나 중배축장과 분리근의 건물중간에는 중배축장이 클수록 건근중이 크게 나타났다.