Compared to steel of the same weight in steel concrete structures, fiber reinforced polymer (FRP) is known to have greater strength and better resistance to corrosion. As such, it is being proposed as an effective structural material. Despite its many advantages, FRP has not been rapidly adopted in civil structures. This is because it is more expensive, prone to brittle fracture, and has weak fire resistance. To examine changes in the mechanical properties of FRP and the effectiveness of fire resistant coating, this study conducted tensile tests on coated and uncoated specimens over varying temperature. Glass fiber has excellent fire resistance since it does not melt or burn at high temperatures. However, epoxy is unable to withstand exposure to temperatures exceeding the transition temperature, thus leading to unsatisfactory structural performance and fire resistance. This study investigated the behavioral changes in FRP by exposing the specimens to temperatures ranging from room temperature (approx. 25℃) to 300℃, so as to improve the fire resistance of epoxy.
The corrosion resistance of submerged entry nozzle (SEN) materials were investigated for high-class steel manufacturing. Composite samples were fabricated by mixing ZrO2, Al2O3, MgO, mullite, spinel, and carbon. The raw materials were mixed with attrition milling, compacted in a uniaxial pressure of 200MPa and calcined at 1000˚C for 3 h in N2 atmosphere. The bulk density and apparent porosity of the calcined samples were measured by the liquid displacement method in water using Archimedes's principle. The corrosion resistance of the samples were measured by cup test with mold powder at 1550˚C for 2 h. The microstructure and elemental analysis of samples were observed by scanning electron microscopy (SEM), energy dispersive spectrum (EDS), and X-ray diffraction pattern (XRD). The XRD result shows that the starting raw materials were crystalline phase. The microstructure of fabricated specimen was investigated before and after corrosion tests at 1000˚C and 1550˚C for 2h. ZrO2-C composite showed good resistance in the slag corrosion test. Among the composite oxide materials, ZrO2-Al2O3-C and ZrO2-MgO-C showed better resistance than ZrO2-C in the slag corrosion test. The diameter variation index of ZrO2-C refractory was 16.1 at 1000˚C for 2 h. The diameter variation index of the ZrO2-Al2O3-C refractory was larger than that of the ZrO2-C refractory at 1550˚C for 2 h.
This study is to find out if it can be recycled for making better concrete. Therefore, waste paper as of newspaper and newspaper are added into concrete to see if waste paper-mixing concrete can have any particular characteristic. The test result of paper concrete was compared and analyzed through four kinds of tests such as compressive strength as of a fundamental one of concrete resistant capacity against heat. 200℃, 400℃ and 600℃ heated concrete were compressively tested in order to find out concrete strength resistant to high temperature. heat capacity was also tested, based on the expectancy of its low conductivity. finally flexural strength test using four reinforced concrete beams with size of 20cm×30cm×160cm was made. And concrete property exposed to the temperature showed that there are almost not effect for the strength up to 400℃, but it was decreased down to 50% of the original condition. volume of paper mixed with concrete without relation to paper kinds of new and waste one.
In this study, to evaluate the performance of fire resistance of the mortar with magnesium hydroxide(MH) and aluminium hydroxide(AH) which has a RCC (Radiant Control Capability) as repair material to the steel structure, temperature evaluation of mortar was conducted by increasing 500°C in the furnace. The performance of RCC can decrease a temperature to external and internal mortar. As a result, it is confirmed that temperatures of mortar with magnesium hydroxide(MH) and aluminium hydroxide(AH) were more decreased than general mortar due to the RCC effect of MH and AH. Therefore, it can be possible to apply to a repair material at the steel structure.
본 연구에서는 우선 화재에 노출된 고강도 콘크리트의 내화특성과 폭렬 메커니즘을 규명한 기존 국내외 연구자들의 연구문헌들을 심도 깊게 고찰하였다. 그 후 고온을 받은 고강도 콘크리트에 대한 국내외 연구자들의 주요 실험 변수를 분석하여 가장 최적의 변수를 설정하였으며 이를 토대로 하여 100MPa급 고강도 콘크리트의 내화 특성을 규명하기 위한 내화실험을 계획하였다. 또한 기존 연구의 실험결과를분석한 결과 폭렬방지에 효과가 있는 것으로 알려져 있는 PP섬유와 친수성 재료로서 시멘트 입자와 부착성능이 우수하고 워커빌리티를 개선할 수 있는 NY섬유를 혼합한 신재료 HB섬유를 섬유혼입률 0.05%로 정해 배합설계에 반영하였다. 이러한 배합설계로 타설한 총 48개의 공시체를 28일 양생기간 후 온도변화 (100℃~700℃)에 따른 고강도 콘크리트의 역학적 특성을 분석하기 위해 화재를 받은 후 냉간상태에서의 내화실험을 수행하였으며 이를 통해 고강도 콘크리트의 내화 특성을 분석하였다.
In this study, the silicone-based flame retardant compound is combined in case of fire, the fire-resistance board structure stability and durability, performance, such as the possibility of secure confirmation. For this purpose, a silicon compound ATH, MDH, MC, a flame retardant of ocher made by the weight ratio, the thermal properties of the specimen analysis tests were carried out.
화재발생시 콘크리트충전 강관(CFT)기둥은 강재의 표면이 고열에 직접 노출되기 때문에 강관의 내화피복에 따라 내화성능에서 많은 차이가 예상된다. 본 연구에서는 내화피복 CFT기둥의 온도분포특성을 파악하기 위하여 내화피복의 종류와 두께 및 내화시간을 변수로 하여 실험을 실시하였다. 실험결과 가열온도를 기준으로 내화성능은 내화뿜칠, 내화페인트, 무내화의 순으로 나타났다. 가열시간-위치별 온도분포는 콘크리트부분은 완만한 증가를 보이고 있으나, 강관외부표면에 도달하면 급격한 온도의 증가를 보이는 것으로 나타났다.
본 연구에서는 RC 기둥의 폭렬방지를 위하여 유기섬유의 혼입방식, 내화보드 부착방식, 스프레이 방식의 폭렬방지공법에 따른 내화특성을 검토하였는데, 그 결과를 요약하면 다음과 같다. 굳지않은 콘크리트의 특성으로, 유기섬유의 혼입율이 증가에 따른 유동성은 저하하는 것으로 나타났고, 섬유의 종류에 따라서는 NY섬유를 혼합한 경우 가장 양호하였다. 공기량은 NY섬유가 가장 적게 저하하였고, 그 다음으로 PVA, PP순이었다. 경화 콘크리트의 특성으로, 압축강도는 28일 재령에서 50MPa이상으로 섬유의 혼입율이 증가할 수록 약간 크게 나타났다. 내화시험후 폭렬특성으로, 유기섬유 혼입방식의 경우 PVA섬유를 제외한 PP섬유, NY섬유는 혼입율 0.05%이상에서 폭렬이 발생하지 않는 것으로 나타났다. 스프레이 방식의 경우는 모든 마감재 부분에서 부분적인 폭렬이 발생하였을 뿐, 모재 콘크리트는 폭렬이 발생하지 않고 본래의 형상을 그대로 유지하는 것으로 나타났다. 또한, 보드방식의 경우는 보편적인 일반 건식공법인 경우를 제외한 건식공법 시공 후 내화페인트로 연결철물을 도포한 경우, 내화모르터로 차폐한 경우, 경량기포 콘크리트로 그라우트 한 경우는 모두 폭렬이 발생하지 않고 본래의 형상을 그대로 유지하고 있었다. 질량감소율은 플레인 콘크리트를 제외한 내화시공공법변화에 따라서 공히 8%미만으로 비교적 양호하게 나타났다.
건축물의 초고층화에 따라 최근 고성능 콘크리트의 사용이 증가하고 있다. 이러한 고성능 콘크리트는 고강도, 고유동, 고내구성 등 다양한 성능을 발휘하지만, 화재시 폭열에는 약한 것으로 알려져 있다. 본 연구는 PP섬유 혼입 및 마감재 변화에 따른 고성능 RC 기둥의 폭열방지 성능을 검토한 것이다. 실험결과 내화시험 후 폭열특성으로, 먼저 플레인의 경우 심한 파괴 폭열과 함께 철근이 노출됐고 내화뿜칠로 마감한 고성능 콘크리트는 내부 수분의 영향으로 플레인보다 더욱 심한 폭열을 나타냈다. 또한, 마감재 변화에 따른 시험체의 폭열특성으로는 내화도료로 마감한 경우가 가장 우수한 폭열방지 효과를 나타냈으며 폴리프로필렌 섬유를 0.1%혼입한 콘크리트는 3시간 가력 내화시험 후 가장 안전한 폭열방지 성능을 입증하였다.