This study examines the Gyeongju Seokguram Grotto restoration project (1961-1962) by architect Kim Chung Up (1922-1988) and introduces the documents he wrote at the time of planning. The study highlights Kim’s Plan attempt to adopt Buckminster Fuller’s idea of the Geodesic Dome, while inheriting the architect Pai Ki Hyung’s previous design plan which was nullified. As Seokguram Grotto’s water leak and deterioration issues have been brought up, the four-times survey was carried out by experts team between 1958 and 1960, under Ministry of Education’s direction. Pai designed an initial restoration plan based on the survey’s result, which was a double-dome structure with a concrete film on the outer periphery as a way to protect Seokguram Grotto in January 1961. However, as drawbacks, such as the heavy load of the concrete dome, and non-installation of entrance hall, have been indicated in the review process, the Cultural Properties Committee rejected the plan. Subsequently, Kim was appointed as the supervisor of the second restoration project. Kim drew up a process management schedule to be implemented from August 1961 to December 1963 and designed the conception plans for the second restoration design. This study analyzes Kim’s Plan by examining sketches, site plans, floor plans, and sections. Kim planned to maintain the idea of the double-dome structure proposed by Pai while applying Buckminster Fuller’s idea of the Geodesic Dome. Kim planned to lighten the dome structure by applying a steel-frame Geodesic Dome so that the dome structure could be supported by its own. The study is expected to reclaim the omitted parts from Seokguram Grotto's historical description and Kim's careers.
When domestic sewage and rainwater runoff are discharged into a single sewer pipe, it is called a “combined sewer system.” The sewage design standards in Korea specify the flow velocity based only on the volume of rainfall; therefore, sedimentation occurs on non-rainy days owing to the reduced flow rate and velocity. This sedimentation reduces the discharge capacity, causes unpleasant odors, and exacerbates the problem of combined sewer overflow concentration. To address this problem, the amount of sewage on non-rainy days, not just the volume of rainfall, should also be considered. There are various theories on sedimentation in sewer movement. This study introduces a self-cleansing velocity based on tractive force theory. By applying a self-cleansing velocity equivalent to the critical shear stress of a sand particle, sedimentation can be reduced on non-rainy days. The amount of sewage changes according to the water use pattern of citizens. The design hourly maximum wastewater flow was considered as a representative value, and the velocity of this flow should be more than the self-cleansing velocity. This design method requires a steeper gradient than existing design criteria. Therefore, the existing sewer pipelines need to be improved and repaired accordingly. In this study, five types of improvement and repair methods that can maximize the use of existing pipelines and minimize the depth of excavation are proposed. The key technologies utilized are trenchless sewer rehabilitation and complex cross-section pipes. Trenchless sewer rehabilitation is a popular sewage repair method. However, it is complex because the cross-section pipes do not have a universal design and require continuous research and development. In an old metropolis with a combined sewer system, it is difficult to carry out excavation work; hence, the methods presented in this study may be useful in the future.
This study examines the restoration project of Sokkuram, and introduces its preliminary plans by the architect Pai Ki Hyung. The restoration project started in 1958 with an inquiry committee of the restoration project, and was completed in 1964. Despite having undergone extensive repair work under Japanese supervision from 1913 and 1923, the repair work caused water leakages inside Sokkuram, and regular cleaning work that began in 1933 caused a lot of damage to the sculpture. In result of the surveys, the top priority of this project was to protect the sculptures inside Sokkuram by improving the environment of the cave. At that time, the architect Mr. Pai participated as a head of the fourth field surveyors to plan the restoration project and to design the preliminary plans. He proposed the installation of a double dome structure to prevent further water leakages on the concrete addition that was built up around the grotto by the Japanese. However, in 1961, the Cultural Heritage Committee of Korea examined the plans of Mr. Pai and immediately rejected them. The factors of the rejection were the omitting of entrance design, system of new double dome structure that presses the existing structure, and these changes that had to be made outside of the drainage plans. The repair work of Sokkuram began in 1961, and the main construction was building double dome structure and entrance installation. In this we realize that Mr. Pai’s double dome structure plans were very important key concept of this project. This study attempts to demonstrate the double dome installations that Mr. Pai initially proposed, which ultimately remains as emblematic factors of Sokkuram’s legacy.
PURPOSES : This research describes how to predict the life cycles of fatigue cracking based on NCHRP Report 704 as well as modified harmony search (MHS) algorithm. METHODS : The fatigue cracking regression model of NCHRP Report 704 was used in order to calculate the ESAL (Equivalent Single Axle Load) numbers up to pavement failure, based on using material parameters, composite modulus, and surface pavement thickness. Furthermore, the MHS algorithm was implemented to find appropriate material parameters and other structural conditions given the number of ESALs, which is related to pavement service life. RESULTS: The case studies show that the material and structural parameters can be obtained, resulting in satisfying the failure endurance of asphalt concrete structure, given the number of ESALs. For example, the required ESALs such as one or two millions are targeted to satisfy the service performance of asphalt concrete pavements in this study. CONCLUSIONS : According to the case studies, It can be concluded that the MHS algorithm provides a good tool of optimization problems in terms of minimizing the difference between the required service cycles, which is a given value, and the calculated service cycles, which is obtained from the fatigue cracking regression model.
선박운항 시뮬레이터와 같이 시스템이 복잡하고 사용자의 요구사항이 다양한 시스템에 대한 유지보수는 개발 못지않게 매우 어려운 업무이다. 이에 본 논문에서는 시뮬레이터 유지보수를 어렵게 하는 여러 요인에 대해 분석하고, 효율적인 유지보수를 위해 설계 및 개발 단계에서부터 고려해야 할 대책들로 접근 및 교환 용이성 향상 방안, 복잡한 시스템 유지 방안, 복합 영역 관리 방안, 사용자 요구사항 수렴 방안 등 여러 방안들에 대한 실무적인 연구 결과를 제
This paper reviews the requirements of the sound - absorbing block for the maintenance of the concrete track and suggests ways to solve it. It is applied to the design and production by preparing the shape improvement plan so that the cracks of the road can be observed. In order to secure safety by tunnel lift in the tunnel, the lift generated by computational fluid dynamics analysis is examined to confirm the safety of the sound absorption block.
염해에 따라 발생하는 보수시기와 보수로 유지되는 내구수명은 보수비용 평가에 매우 중요한 요소이다. 일반적으로 사용하는 결정 론적 보수비용 평가는 사용기간의 연장에 따라 계단식으로 증가하게 되며, 보수로 인해 변동되는 내구수명의 변화를 고려하지 못한다. 본 연구 에서는 확률론적인 보수시기 및 비용을 평가하기 위해, 염해에 노출된 콘크리트 교각을 선정하였다. 두 가지 배합과 염화물에 노출된 외부 환 경조건을 고려하여 염화물 거동을 평가하였으며, 도출된 내구수명과 수명에 대한 확률변수를 변화시키면서 보수시기 및 비용 변화를 분석하 였다. 변동계수의 변화에 따른 보수회수는 큰 차이가 발생하지 않았으나, 초기의 내구수명 연장이 구조물의 보수시기 및 비용에 큰 영향을 미 치고 있었다. 또한 확률론적 보수비용 산정 모델은 결정론적 모델과 다르게 연속적인 보수비용이 평가되므로 목표내구수명에 따라 보수회수 를 감소시킬 수 있는 효과적인 기법임을 규명되었다.
This study aims to establish design and construction procedure in the fields of the repair and rehabilitation for existing concrete structures. The codes used in this study are ISO 16311 and ACI 562-16. The ISO 16311 and ACI 562-16 focused on maintenance and repair, respectively. After, we will make to design and construction guidelines to meet the domestic situation through analysis the repair and rehabilitation parts of the codes in detail.