PURPOSES : To enhance the accuracy of predicting the compressive strength of practical concrete mixtures, this study aimed to develop a machine learning model by utilizing the most commonly employed curing age, specifically, the 28-day curing period. The training dataset consisted of concrete mixture sample data at this curing age, along with samples subjected to a total load not exceeding 2,350 kg. The objective was to train a machine learning model to create a more practical predictive model suitable for real-world applications. METHODS : Three machine learning models—random forest, gradient boosting, and AdaBoost—were selected. Subsequently, the prepared dataset was used to train the selected models. Model 1 was trained using concrete sample data from the 28th curing day, followed by a comprehensive analysis of the results. For Model 2, training was conducted using data from the 28th day of curing, focusing specifically on instances where the total load was 2,350 kg or less. The results were systematically analyzed to determine the most suitable machine learning model for predicting the compressive strength of concrete. RESULTS : The machine learning model trained on concrete sample data from the 28th day of curing with a total weight of 2,350 kg or less exhibited higher accuracy than the model trained on weight-unrestricted data from the 28th day of curing. The models were evaluated in terms of accuracy, with the gradient boosting, AdaBoost, and random forest models demonstrating high accuracy, in that order. CONCLUSIONS : Machine learning models trained using concrete mix data based on practical and real-world scenarios demonstrated a higher accuracy than models trained on impractical concrete mix data. This case illustrates the significance of not only the quantity but also the quality of the data during the machine learning training process. Excluding outliers from the data appears to result in better accuracy for machine learning models. This underscores the importance of using high-quality and practical mixed concrete data for reliable and accurate model training.
PURPOSES: The objective of this study is to evaluate the properties of high-performance concrete and compare them with the properties of ternary blended cement (OPC 60% : BFS 30% : FA 10%) as applied to all-in-one bridge decks. High-performance concrete modified with styrene-butadiene latex (SB latex) was evaluated for strength development and durability through its compressive strength and chloride ion diffusion coefficient.
METHODS: The compressive strength test was conducted according to KS F 2405, and the average value of the three specimens was used as the result at each stage. The chloride ion diffusion test was performed at 28 days, 56 days, and 365 days according to NT BUILLD 492. The chloride ion penetration test was conducted according to ASTM C 1202.
RESULTS: For the compressive strength of the high-performance concrete, the blast furnace slag 40% replacement (BFS40) mixture had the most similar results to those of the ternary blended cement. The BFS40 mixture exhibited a lower compressive strength at 3 days than the latex modified concrete (LMC) mixture used for the bridge deck pavement, whereas it exhibited a 3.7-9.8% higher compressive strength at 7 days. In addition, the BFS40 mixture had the lowest diffusion coefficient, which was 49.1~59.0% lower than that of the LMC mixture. Mixing with latex tended to decrease in charge passed compared to Plain which is only used ternary blended cement, and showed excellent watertighness (rated “very low”), which is lower than 1,000 coulombs in all mixtures with latex.
CONCLUSIONS : The BFS40 mixture exhibited excellent compressive strength, chloride ion permeability resistance, and the lowest chloride ion diffusion coefficient although it included a small amount of latex, which makes it more expensive than the current LMC mixture. It is believed that it is possible to secure excellent economic efficiency and durability by using lesser latex than that in the LMC mixture and using a mixture of the blast furnace slag instead.
콘크리트관은 하수관으로 널리 쓰이지만, 중량이 무거워 취급이 곤란한 단점이 있다. 또한 하수 및 해수 지역에 매설될 경우 황산수소(H2S)와 염화물에 의한 화학적 침식 등으로 인해 균열, 단면 감소 등 각종 열화현상이 발생하게 되어 파형강관을 대신하여 사용하지만 시공특성상 파손이 생기거나 매설지역에 부등침하가 존재하거나 과도한 외부압력이 작용할 경우 누수 또는 파손이 발생하여 관거로서의 기능이 저하될 우려가 있다.
이에 본 논문에서는 3겹으로 코팅된 수지파형강관(CCSP)을 파형강관 대신 하수관에 적용하기 위한 연구를 수행하였으며 우선 CCSP를 화학약품에 침지한 후 마모율 및 중량감소 등을 통해 화학저항성을 알아보았다. 특히 해안가에 시공될 경우 장기재령 내구성능을 확인하기 위해 부산 감만항 인근에 수지파형강관을 매설한 후 재령 10년 및 15년이 경과한 시점에 피복부착력을 확인하기 위해 염수분무, 핀홀, 음극박리시험을 실시하였으며 외압에 대한 저항성을 알아보기 위해 재하시험을 실시하였으며 그 결과 모든 항목에서 KS품질 기준을 만족하고 관거로서의 소요성능을 확보하고 있어 장기재령 내구성을 확보하고 있음을 확인하였다.
The purpose of this study is to analyze the changing process in the Ddeulzip of Jaeryoung Lee's clan family. The subject of this study is clan family of Jaeryoung Lee in Andong Area. The period of Ddeulzip's changing process is divided into largely three parts. The establishment process and changing process for Jaeryoung Lee's family is analyzed during early (15~16C), mid(17∼18C) and late(19∼20C) periods.
The characteristics of early periods is that it made a main ancestral building of Ddeulzip form. Those of mid Chosun period is in their strong will to preserve their ancestral house. During the late period, many of the different styles of Ddeulzip were constructed due to the stable environment of both political and economical status. The residential house of Jaeryoung Lee family that were centered in Youngduk and Youngyang area include diverse forms for both high and middle class social status. Jaeryoung Lee family's Ddeulzip is thus considered to bring about the firm foundation as a clan family representing the Andong cultural area through the development of Ddeulzip.
The Age-adjusted effective Modulus Method(AEMM) is one of the methods adopted for the construction stage analysis of concrete structures. The AEMM uses the aging factor to consider the effects of the varying concrete stress. In the aspects of computation time and the accuracy of the results, the AEMM is considered as one of most appropriate methods for construction stage analysis of tall building structures. Previous researches proposed appropriate values of the aging factor in the forms of graphs or using very simple equations. In this paper, an equation for estimating the aging factor as a function of rebar ratio in the section, compressive strength of concrete, notional member dimension, and age of concrete at the load application. The validity of aging factor proposed in this paper were examined by the comparison with the results of step-by step method.
CSA, a cement mineral compound that is mainly composed of 3CaO·3Al2O3·CaSO4, generates ettringite as a hydration product after a reaction with glass (lime), gypsum and water to speed up the hardening process and enhance the strength and degree of expansion. When used as a cement admixture, there is increased production of ettringite, which can improve the initial strength in the first three days and ameliorate the reduction in the initial strength caused by the use of fly ash in particular. In this study, a hydrate analysis was performed using XRD and SEM after substitution with fly ash (30%) and CSA (8%) with the goal of observing the effect of CSA on the initial strength of a cement mixture containing fly ash. The results of the analysis showed that an addition of CSA promoted the production of ettringite and improved the initial strength, resulting in the generation of hydrates, which can effectively enhance the long-term strength of these materials.
국내 일반국도는 대부분의 포장이 아스팔트 포장으로 이루어져있으며, 2011년 말을 기준으로 총연장 13,739km로 전체 도로연장 중 약 105,931km로 약 13%를 차지하고, 포장구간의 연장은 13,459km로써 약 97.6%의 포장률을 나타내고 있다. 이와 더불어 전 세계적으로 지구온난화로 인한 연평균기온 및 해수면 상승, 기습폭우 및 태풍 등과 같은 환경영향은 도로포장체의 성능을 저하시키는 요인으로 작용함으로써 포장수명을 단축시키는 문제로 이어지고 있다. 본 연구에서는 일반국도 아스팔트 포장 구간의 포장재령별 신설 0년, 재령 6년, 재령 10년에 대한 소음측정구간을 선정 한 후, 길어깨 소음측정법(Pass-By methods)을 사용하여 도로교 통소음에 대한 포장재령별 소음특성을 평가하였다.
본 연구를 통해서 그림 2와 같이, 신설 0년의 경우 평균 75.9dB(A), 재령 6년은 77.8dB(A), 재령 10년은 76.7dB(A) 값을 보였으며, 이 차이가 평균 1.9dB(A)를 나타냈다. 따라서 일반국도 아스팔트 포장의 재령이 6년인 시점에서 가장 높은 소음특성을 보였으며, 일반국도 아스팔트 포장의 공용수명이 8년~9년인 점을 감안할 때, 포 장의 공용수명에 인접할수록 소음이 보다 높게 나타난 것으로 판단된다. 하지만, 포장노면의 파손상태 및 주변 환 경 등이 상이함으로써, 이에 대한 향후 추가적인 연구가 필요할 것으로 사료된다.
Concrete Carbonation is usually measured as discoloration, as it has one of strengths to be economical, and simple and immediately confirm the given results in the spot. And, when Carbonation is measured as Phenolphthalein Solution, it is possible to confirm the scope of alkali through acid and basic reaction. Then, Concrete Basic Reaction is decided according to alkali concentration depending on Potassium Hydroxide Now that Carbonation is gradually produced toward inner side from outer side, with time going by, it doesn’t work, to some adequate depth, in as fast time as compulsory facilitating test. Thus, this research thesis made a comparative analysis on concrete phenomenal discoloration borderline following Phenolphthalein Solution, as part of a bid to measure Carbonation. Also, the thesis measured 'Concrete Alkali Concentration. The result showed that concrete coloring is classified into red and scarlet according to alkali concentration, and into borderline breakpoint of the speckle of scarlet and carbonation reaction. The higher chroma becomes with concrete decolorizing, the higher alkali concentration becomes. Also, it was demonstrated that for long-term concrete discoloration borderline, discoloration degree can be determined by amounts of Potassium Hydroxide. Such result proved that limiting the extent of only red color as alkali, in the process of deciding on the scope of concrete alkali, can be served as an error in measuring service life of Concrete Carbonation.
온도 및 수분 등과 같은 환경적인 요인들은 슬래브의 컬링을 유발하여 줄눈 콘크리트 포장의 장기적인 거동과 공용성에 영향을 미치는 것으로 알려져 있다. 하지만, 콘크리트 슬래브의 컬링에 관한 상세한 조사가 부족한 실정이므로 컬링과 이에 미치는 요인들의 관계는 아직까지도 명확하게 정의되지 못하고 있다. 본 연구에서는 현장에 건설된 줄눈 콘크리트포장의한 슬래브에 각종 계측기를 매설하여 콘크리트 슬래브의 온도, 상대습도, 변형률, 연직변위, 그리고 슬래브 좌우측 줄눈부의 수평방향 움직임을 조사하였다. 콘크리트 타설 직후부터 약 4일간 측정된 현장자료를 분석하여 초기 재령 콘크리트 슬래브의 컬링에 미치는 온도 및 수분의 영향과 줄눈강성의 크기에 따라 컬링이 구속되는 정도를 조사하였다. 콘크리트 슬래브의 컬링은 주로 온도의 영향 때문에 24시간주기의 사이클을 나타내었으며. 장기적인 건조수축의 영향으로 상향의 컬링이 점차 증가하는 경향을 보였다. 또한, 컬링의 크기와 변화량이 골재 맞물림 등에 기인하는 줄눈강성에 영향을 크게 받는 것으로 조사되었다. 향후 온도에 의 한 계절별 줄눈강성의 변화와 장기적인 건조수축이 콘크리트 슬래브의 컬링에 미치는 영향을 추가로 조사할 예정이다.
연속철근콘크리트포장에서 횡방향 균열은 초기의 온도와 습도변화로 인해 발생하며 횡 방향 균열의 폭과 간격은 하중전달효율 및 펀치아웃과 같은 포장공용성에 직접 관련된다. 또한, 연속철근콘크리트포장에서 균열폭은 콘크리트의 건조수축 뿐만아니라 소위 특성 온도변화 시점으로 정의되는 "제로-스트레스 온도"에 의존한다. 연속철근콘크리트포장의 양호한 장기공용성을 위해서 횡방향 균열은 매우 작은 폭으로 유지될 필요가 있으며 초기재령 에서 온도제어는 이를 위한 필수요소라 할 수 있다. 따라서, 본 연구에서는 페이브프로를 사용하여 콘크리트 온도를 예측하였으며 현장실험을 통한 실측온도와 비교하고 균열조사를 수행하였다. 본 연구로부터 도출된 결과는 첫째, 실측온도는 0.2~4.5℃의 범위에서 예측온도보다 큰 것으로 나타났으며 정확한 콘크리트 온도예측을 위해서는 수화특성치로 고려되는 활성화 에너지와 단열온도상수가 입력변수에서 정확히 고려되어야 할 것으로 판단되었다. 둘째. 콘크리트 타설 후 24시간 이내의 온도는 오후에 비하여 오전에 타설된 콘크리트에서 더 크게 나타났으며 최대온도는 정오에 타설된 온도에서 발생되었다. 마지막으로 재령 12일에 조사된 균열발생률은 오전에 타설된 구간에서 25% 증가되고 그 만큼 균열간격은 감소하는 것으로 나타났다. 이 결과로부터 최대 콘크리트 온도는 균열발생에 크게 영향을 미치며 콘크리트 온도제어는 연속철근콘크리트포장의 양호한 공용성을 위해 필요할 것으로 판단되었다.
초기재령 콘크리트 수화과정의 메카니즘과 초기재령 콘크리트 균열 제어기법의 개발은 주로 매시브한 콘크리트를 대상으로 실험적 연구와 수치해석적 연구가 이루어져 왔으나 철근 콘크리트 라멘교의 상부슬래브와 같이 비교적 두께가 적은 부재에 대해서는 연구 내용이 거의 없는 실정이다. 본 연구에서는 4개의 철근 콘크리트 라멘교의 상부 슬래브에 대한 수화열을 현장 실측하여 온도이력과 강도 발현 모텔 및 건조수축 모델에 의한 응력들을 근거로 하여 초기 재령 철근 콘크리트 라멘교의 상부슬래브에 발생할 수 있는 균열을 제어할 수 있는 설계기법을 제시하였다. 본 연구의 해석기법을 이용하여 초기재령 철근 콘크리트 라멘교의 상부슬래브에 발생되는 균열 폭을 계산하여 균열제어를 위한 철근량 산정방법을 제시하였고, 설계하중 재하 시 배력철근으로만 취급되는 헌치부의 철근이 초기재령 철근콘크리트 라멘교의 온도응력 검토 시에는 주철근이 됨을 알 수 있었다. 제안한 해석기법은 초기재령 철근콘크리트 라멘교의 온도균열제어를 위한 설계에 적용될 수 있을 것으로 판단된다.
콘크리트의 수화물 및 이와 관련된 특성치들은 재령에 따라 변화하며 이는 염화물 확산성과 큰 관련이 있다. 본 연구에서는 세 가지 수준의 물-결합재 비와 플라이 애시 및 고로슬래그 미분말을 30% 혼입한 콘크리트 대하여 2년간 장기 양생을 수행하였다. 5번의 측정 시점(28일, 56일, 180일, 365일, 730일)에 대하여 촉진실험을 통하여 촉진 염화물 확산계수를 평가하였으며, DUCOM을 통하여 도출된 공극률, 염화물 구속능, 투수계수의 변화와 비교하였다. 염화물 확산성과 투수성의 변화 패턴이 가장 유사하였는데, 이는 투수성이 공극률의 제곱에 비례하기 때문이다. 또한, 각 재령 기간 동안 변화하는 비율을 분석하였는데, 초기 재령(재령 28일~56일)에서 공극률, 투수성 및 염화물 확산성의 변화가 지배적이었고, 낮은 물-결합재 비를 가진 OPC 콘크리트에서는 180일까지 확산성의 변화가 지속적으로 크게 평가되었다.
이 연구에서는 단일 활성화제로 활성화시킨 슬래그 기반 섬유보강 복합재료의 초기재령에서 인장거동을 조사하였다. 실험 결과, 활성화제 종류에 따라 재령 7일에서 균열강도, 인장강도, 인장변형성능에 차이가 있었으며, 규산나트륨을 활성화제로 사용한 배합이 가장 큰 인장변형성능을 나타내었다.
최근 도심지의 초고층 건물 및 대형 구조물이 늘어나면서 고강도콘크리트 사용이 증가되고 있으며, 이를 적용한 구조물에 화재시 부재 표면이 고온에 노출될 경우 심한 폭음과 함께 콘크리트의 균열을 발생시켜 구조물의 내력이 저하시킬 수 있다. 따라서 내화모르타르를 구조부재에 활용하기 위하여 산업부산물(플라이애시, 고로슬래그 미분말)과 섬유 혼입(PP섬유, PVA 섬유, 강섬유)으로 내화모르타르의 내화특성을 비교분석하여 고강도콘크리트의 폭열방지를 위한 내화소재 개발의 기초적인 자료로 활용하고자 한다.
매립지 감소 및 천연 잔골재의 부족으로 인해 산업부산물을 콘크리트의 골재로 사용하려는 연구가 최근 들어 빠르게 진행되고 있다. 본 연구에서는 EOS 잔골재를 치환하여,OPC 콘크리트 배합과 GGBFS 배합을 대상으로 초기재령에서의 공학적 특성을 평가하였다. 실험은 EOS 잔골재를 0%, 30%, 50%로 치환, GGBFS를 0%, 40% 치환하여 물-결합재비 60% 콘크리트로 실험을 진행하였다. 굳지 않은 콘크리트에서 슬럼프, 공기량, 단위용적질량을 평가하였으며, 경화 콘크리트에서 압축강도와 NT BUILD 492 방법을 이용한 염화물 확산계수를 도출하고 EOS 골재 치환에 따른 내구성능을 평가하였다. 본 연구의 실험결과 EOS 잔골재를 치환함에 따라 재령 3일, 7일까지는 압축강도 발현이 각 기준 배합에 비해 증가함을 확인하였지만, 재령 28일에서는 일부 감소하는 것을 확인하였다. 또한 촉진 염화물 침투 실험결과, GGBFS 콘크리트 배합에서 OPC콘크리트 배합과 비교하여 약 60~67% 감소하였으며, EOS 잔골재 50% 치환 배합에서 가장 낮은 염화물 확산계수가 나타남에 따라 EOS 잔골재가 OPC 및 GGBFS 콘크리트에 사용될 수 있는 공학적 가능성을 제시하였다.
원자력발전소 콘크리트 구조물은 해안가에 접해 있으며, 해수를 취수하여 냉각수로 사용하기 때문에 염해에 의한 내구성은 매우 중요하다. 이를 위해 3년간의 염해 장기침지시험을 실시하여 염화물이온확산계수의 변화 및 재령계수(m)을 평가한 결과 4,000 Class인 구조물 기초의 m은 0.35~0.39로 KCI나 ACI 제안값과 유사한 결과를 나타내었고 5,000 Class인 필수 냉각수 구조물 및 터널은 0.44~0.53, 6,000 Class인 원자로 격납건물은 0.62로 FIB 제안값과 유사하였다. 실측된 재령계수로 내구수명을 예측한 결과 원전의 모든 안전관련 콘크리트 구조물은 설계수명 60년 이상을 만족하는 것으로 나타났다.
This study was conducted to evaluate the effect of self-sensing performance on strain-hardening cement composite containing CNT by curing age. The mixing amount of CNT was set at 1.0%, and SHCC fibers were mixed with PE 1.0% and steel fiber 0.5%. The electrical resistance measurement for the tensile strain sensing performance was based on AC method and 4 probe methods. Test results indicated that electrical sensitivity of SHCC decreased with an increase in curing age.